Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Fabrication and Study of a Concave Crystal Mirror for the KORTES Project

A method for fabrication of a concave spherical mirror made of crystalline quartz is proposed and X-ray optical properties of the mirror are studied. The radius of curvature is 1630 mm. The shape of the mirror surface is studied using an interferometer with a diffraction reference wave. In the entire processing region, the maximum deviation from the nearest sphere is about 0.2 μm and the rms is 34 nm, so that high quality of imaging is provided with an angular error of about 2″ (angular seconds). Reflection coefficient (about 7%) and lower bound limit of spectral selectivity (λ/δλ ≈ 1775) are determined in the vicinity of a wavelength of λ = 0.834 nm, which is close to the working wavelengths of the MgXII doublet (λ = 0.8418 and 0.8423 nm). Position of the Bragg peak and spectral selectivity remain unchanged upon bending of the crystal mirror within measurement accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Large aperture interferometer with phase-conjugate self-reference beam

A large aperture self-referencing interferometer consisting of a Twyman-Green interferometer using a self-pumped phase conjugator in series with test section optics is described and experimentally demonstrated. This interferometer provides twice the fringe shift of a Mach-Zehnder (M-Z) interferometer for a given optical phase change induced within the test section. It also provides greater irradiance in the reference beam than does a similar series setup utilizing a M-Z interferometer incorporating a local reference beam. Whereas the ordinary interferometer records instantaneous conditions, the new one records overage conditions if a BaTiO3 crystal is used as the phase conjugator.

Howes, W. L.↗

Performance of a MEMS-base Adaptive Optics Optical Coherency Tomography System

We have demonstrated that a microelectrical mechanical systems (MEMS) deformable mirror can be flattened to < 1 nm RMS within controllable spatial frequencies over a 9.2-mm aperture making it a viable option for high-contrast adaptive optics systems (also known as Extreme Adaptive Optics). The Extreme Adaptive Optics Testbed at UC Santa Cruz is being used to investigate and develop technologies for high-contrast imaging, especially wavefront control. A phase shifting diffraction interferometer (PSDI) measures wavefront errors with sub-nm precision and accuracy for metrology and wavefront control. Consistent flattening, required testing and characterization of the individual actuator response, including the effects of dead and low-response actuators. Stability and repeatability of the MEMS devices was also tested. An error budget for MEMS closed loop performance will summarize MEMS characterization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implementation of Nonlinear Control Laws for an Optical Delay Line

This paper discusses the implementation of a globally stable nonlinear controller algorithm for the Realtime Interferometer Control System Testbed (RICST) brassboard optical delay line (ODL) developed for the Interferometry Technology Program at the Jet Propulsion Laboratory.

nonlinear↗

Process for rapid detection of fratricidal defects on optics using Linescan Phase Differential Imaging

Phase-defects on optics used in high-power lasers can cause light intensification leading to laser-induced damage of downstream optics. We introduce Linescan Phase Differential Imaging (LPDI), a large-area dark-field imaging technique able to identify phase-defects in the bulk or surface of large-aperture optics with a 67 second scan-time. Potential phase-defects in the LPDI images are indentified by an image analysis code and measured with a Phase Shifting Diffraction Interferometer (PSDI). The PSDI data is used to calculate the defects potential for downstream damage using an empirical laser-damage model that incorporates a laser propagation code. A ray tracing model of LPDI was developed to enhance our understanding of its phase-defect detection mechanism and reveal limitations.

42 ENGINEERING↗

Parallel Wavefront Analysis for a 4D Interferometer

This software provides a programming interface for automating data collection with a PhaseCam interferometer from 4D Technology, and distributing the image-processing algorithm across a cluster of general-purpose computers. Multiple instances of 4Sight (4D Technology s proprietary software) run on a networked cluster of computers. Each connects to a single server (the controller) and waits for instructions. The controller directs the interferometer to several images, then assigns each image to a different computer for processing. When the image processing is finished, the server directs one of the computers to collate and combine the processed images, saving the resulting measurement in a file on a disk. The available software captures approximately 100 images and analyzes them immediately. This software separates the capture and analysis processes, so that analysis can be done at a different time and faster by running the algorithm in parallel across several processors. The PhaseCam family of interferometers can measure an optical system in milliseconds, but it takes many seconds to process the data so that it is usable. In characterizing an adaptive optics system, like the next generation of astronomical observatories, thousands of measurements are required, and the processing time quickly becomes excessive. A programming interface distributes data processing for a PhaseCam interferometer across a Windows computing cluster. A scriptable controller program coordinates data acquisition from the interferometer, storage on networked hard disks, and parallel processing. Idle time of the interferometer is minimized. This architecture is implemented in Python and JavaScript, and may be altered to fit a customer s needs.

Rao, Shanti R.↗

An Overview of Broadband Laser Ranging (BLR) Architecture and Measurement Considerations

Broadband Laser Ranging (BLR) is a developmental diagnostic intended to measure the position of rapidly moving surfaces in combination with optical velocimetry. Design and employment of a BLR diagnostic on dynamic experiments requires consideration for both the inherent measurement system tradeoffs as well as architectural choices appropriate to the nature of investigation. The diagnostic uses spectral interferometry to measure distance by mapping femtosecond laser pulses to the time domain via chromatic dispersion within the fiber-optic architecture. The system parameters and governing equations that describe measurement range, resolution, and Doppler sensitivity will be discussed. We will also briefly review the impact of diagnostic architectural choices including: nature of interferometer, Interferometric dispersion matching, optical amplification, integration of optical velocimetry, BLR calibration, and field operability. To summarize we will present the architectural and operational approach currently being pursued by NSTec within an on-going collaboration between NSTec, Lawrence Livermore and Los Alamos National Labs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface characterization and testing II; Proceedings of the Meeting, San Diego, CA, Aug. 10, 11, 1989

Various papers on surface characterization and testing are presented. Individual topics addressed include: simple Hartmann test data interpretation, optimum configuration of the Offner null corrector, system for phase-shifting interferometry in the presence of vibration, fringe variation and visibility in speckle-shearing interferometry, functional integral representation of rough surfaces, calibration of surface heights in an interferometric optical profiler, image formation in common path differential profilometers, SEM of optical surfaces, measuring surface profiles with scanning tunneling microscopes, surface profile measurements of curved parts, high-resolution optical profiler, scanning heterodyne interferometer with immunity from microphonics, real-time crystal axis measurements of semiconductor materials, radial metrology with a panoramic annular lens, surface analysis for the characterization of defects in thin-film processes, Spacelab Optical Viewport glass assembly optical test program for the Starlab mission, scanning differential intensity and phase system for optical metrology.

Greivenkamp, John E.↗

A dual purpose optical truss laser metrology system for a space-based far-IR segmented telescope: Figure maintenance and pointing control

To obtain imaging performance as for monolithic mirrors, large segmented reflectors used for astronomy must be actively aligned and pointed to extreme levels of precision. A system concept for a dual purpose optical truss laser metrology system is described which is used for both figure and alignment maintenance and telescope pointing. A two-stage figure active control approach was developed for several proposed spaceborne far infrared segmented telescopes, one of which is the 10-20 meters Large Deployable Reflector (LDR). The first active control stage, the figure initialization control system, aligns the optical elements (i.e., the primary segments, secondary and focal plane assembly) based on images obtained. The second stage, the figure maintenance control system, maintains the alignment between re-initializations using measurements provided by laser interferometers arranged in an optical truss configuration. It measures the relative positions and alignments of the telescope segments so that a controller can reposition them appropriately. The application of this optical truss for figure maintenance control is the subject of the first part of this paper. The second portion of this paper discusses the application of the optical truss to telescope pointing. Here, the laser metrology system is used to transfer pointing information from an external fine guidance sensor (FGS) to the telescope optical boresight as defined by the primary mirror, secondary mirror, and focal plane assembly. Thus, any alignment variations between the two boresights can be observed and accounted for.

Lau, Kenneth↗

Two-dimensional second harmonic dispersion interferometer

An interferometer having a fundamental beam generator, a first second harmonic generator, a waveplate, a second second harmonic generator, a harmonic separator, and a polarizing beam splitter, mounted uniaxially, (i.e., the components are aligned along one optical axis), wherein the interferometer is adapted to change a diameter of a beam to match a diameter of a sample, and to change the diameter of the beam back to its original diameter.

Wessel, Frank Joseph↗

Thoughts on the Kibble–Robinson theory

We revisit the Kibble–Robinson theory, first proposed in 2014 by Kibble and Robinson. This theory significantly simplifies the construction and operation of Kibble balances. We conducted a theoretical investigation of the theory’s assumptions, using a corner cube as the optical target in the interferometer for velocity measurement. We find that it is advantageous to build a mechanism whose output has minimal rotation and horizontal motion. For balances with relative uncertainty targets below $1\times10^{-6}$, the mass pan and the optical target should be suspended from a common gimbal so they have the same vertical velocity and no rotation. In this case, the measurement bias due to Abbe offset is minimized, and the bias due to corner loading is repeatable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adjustable Focus Optical Correction Lens (AFOCL)

This report describes a metrology plan that was developed for the characterization of PLZT-based devices, such as the Adjustable Focus Optical Correction Lens (AFOCL) in support of and as part of the deliverables for NASA contract NAS8-00118. The areas to be investigated include intensiometric effects (those that limit or alter the intensity of the light transmitted through the optic); interferometric effects (the phase change induced through the optic); and polarimetric effects (evaluating the differential lag between two polarization states propagating through the optic). These distinct phenomena are often coupled together in real applications consequently, there is a need to develop different standardized testing apparatus to: (1) isolate one effect from another; (2) gather information for understanding the physical effects; (3) anchor wavefront corrector modeling efforts; (4) develop the ability to decouple different effects; (5) demonstrate the suitability of PLZT technology to perform wavefront correction. The Center for Applied Optics (CAO) at the University of Alabama in Huntsville (UAH) is skilled in the characterization of transmission wavefront shaping devices using traditional interferometers available within the CAO Optical Metrology Laboratory and their Advanced Polarization Test Facility. Besides the imaging and interferometers available, the polarimetry facility has at its disposal, a Mueller Matrix Imaging Polarimeter (MMIP) which is well suited to the characterization of SLMs, polarizers, and thin film coatings within the visible and near-IR spectrums. In addition, the phase-shifting interferometry facilities at NASA-MSFC and the unique interferometers they processes are some of the most advanced available and may be of value especially for performing real-time optical performance evaluation of AFOCL test components.

Peters, Bruce R.↗

High-accuracy interferometer with a prism pair for measurement of the absolute refractive index of glass

We propose a variable-path interferometric technique for the measurement of the absolute refractive index of optical glasses. We use two interferometers to decide the ratio between changes in the optical path in a prism-shaped sample glass and in air resulting from displacement of the sample. The method allows precise measurements to be made without prior knowledge of the properties of the sample. The combined standard uncertainty of the proposed method is 1.6x10{sup -6}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical Fiber Sensor Instrumentation for Slagging Coal Gasifiers

Coal gasifier is one of the most promising solutions for clean fossil energy. Refractory thickness monitoring and online real-time temperature measurement is needed for improved reliability and advanced process control for current and future generation power plants. The objective of this program is to design and implement an optical fiber based sensing system that could potentially be used to monitor refractory wall thickness and temperature inside a coal gasifier. For the thickness monitoring, the system should be able to operate at temperatures up to 1000 C. For this temperature range, silica fiber can still work so it is chosen for the sensor design. The measurement is based on a photon counting optical time domain reflectometer. A narrow light pulse is launched into a silica fiber which could be embedded into the gasifier refractory wall, and is partially reflected by the far end of the fiber. The time of flight of the light pulse in the fiber then gives an indication of the position of the fiber end, which is a function of the wall thickness when the fiber is embedded. Results obtained show a measurement accuracy of {+-}2cm in environment of 1000 C with a saw cut fiber end. When the fiber end is corroded by sodium carbide at 900 C, the accuracy is {+-}3cm. For the temperature measurement, a single crystal sapphire fiber sensor is designed. The sapphire fiber guides the broadband light from a light emitting diode to a sapphire wafer functioning as a Fabry-Perot interferometer and the wafer optical thickness is a function of temperature. The returned optical signal is then demodulated by multimode fiber based whitelight interferometry. The system was tested up to 1500 C with a measurement accuracy of {+-}10 C for the entire measurement range.

01 COAL, LIGNITE, AND PEAT↗

Interferometer

A high resolution interferometer is described. The interferometer is insensitive to slight misalignment of its elements, avoids channeling in the spectrum, generates a maximum equal path fringe contrast, produces an even two sided interferogram without critical matching of the wedge angles of the beamsplitter and compensator wedges, and is optically phase tunable. The interferometer includes a mirror along the path of each beam component produced by the beamsplitter, for reflecting the beam component from the beamsplitter, for reflecting the beam component from the beamsplitter to a corresponding retroreflector and for reflecting the beam returned by the retroreflector back to the beamsplitter. A wedge located along each beam component path, is large enough to cover the retroreflector, so that each beam component passes through the wedge during movement towards the retroreflector and away therefrom.

Breckinridge, J. B.↗

Simultaneous measurement of temperature and strain by cascaded fiber Bragg grating-silicon Fabry-Perot interferometer sensor

We report a fiber-optic sensor configuration with a cascaded fiber Bragg grating (FBG) and a silicon Fabry-Perot interferometer (FPI) for simultaneous measurement of temperature and strain. The sensor is composed of a 5 mm FBG on a single mode fiber and a 100μm thick silicon FPI attached to the tip of the optical fiber. The FBG is surface mounted on the host structure, and the FPI tip is suspended. Due to the stress-free, cantilever configuration, the silicon FPI is insensitive to strain, but sensitive to temperature with a sensitivity much higher than the FBG due to the large thermo-optic coefficient of silicon. The sensor is tested from room temperature to 100°C with varying strain up to ∼150με. The silicon FPI provides high temperature sensitivity of 89 pm/°C unaffected by strain. Since the FBG is attached to the host structure, it is affected by both thermal and mechanical strain; the sensitivity of these was experimentally obtained 32 pm/°C and 1.09 pm / με, respectively. Interrogated with a broadband light source and a high-speed spectrometer, the sensor shows temperature and strain resolutions of 1.9 × 10 −3 °C and 0.042 με, respectively. Here, due to the small size, enhanced sensitivity, and high resolution, this cascaded FBG-FPI sensor can be used in applications where accurate measurement of temperature and strain is required.

42 ENGINEERING↗