Search NASA⌕ Search

SEARCH · Search NASA

Results for “plane of array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Superresolution with Seismic Arrays using Empirical Matched Field Processing

Scattering and refraction of seismic waves can be exploited with empirical matched field processing of array observations to distinguish sources separated by much less than the classical resolution limit. To describe this effect, we use the term 'superresolution', a term widely used in the optics and signal processing literature to denote systems that break the diffraction limit. We illustrate superresolution with Pn signals recorded by the ARCES array in northern Norway, using them to identify the origins with 98.2% accuracy of 549 explosions conducted by closely-spaced mines in northwest Russia. The mines are observed at 340-410 kilometers range and are separated by as little as 3 kilometers. When viewed from ARCES many are separated by just tenths of a degree in azimuth. This classification performance results from an adaptation to transient seismic signals of techniques developed in underwater acoustics for localization of continuous sound sources. Matched field processing is a potential competitor to frequency-wavenumber and waveform correlation methods currently used for event detection, classification and location. It operates by capturing the spatial structure of wavefields incident from a particular source in a series of narrow frequency bands. In the rich seismic scattering environment, closely-spaced sources far from the observing array nonetheless produce distinct wavefield amplitude and phase patterns across the small array aperture. With observations of repeating events, these patterns can be calibrated over a wide band of frequencies (e.g. 2.5-12.5 Hertz) for use in a power estimation technique similar to frequency-wavenumber analysis. The calibrations enable coherent processing at high frequencies at which wavefields normally are considered incoherent under a plane wave model.

58 GEOSCIENCES↗

Emission color-tuned light-emitting diode microarrays of nonpolar In x Ga 1–x N/GaN multishell nanotube heterostructures

Integration of nanostructure lighting source arrays with well-defined emission wavelengths is of great importance for optoelectronic integrated monolithic circuitry. We report on the fabrication and optical properties of GaN-based p–n junction multishell nanotube microarrays with composition-modulated nonpolar m-plane In x Ga 1–x N/GaN multiple quantum wells (MQWs) integrated on c-sapphire or Si substrates. The emission wavelengths were controlled in the visible spectral range of green to violet by varying the indium mole fraction of the In x Ga 1–x N MQWs in the range 0.13 ≤ x ≤ 0.36. Homogeneous emission from the entire area of the nanotube LED arrays was achieved via the formation of MQWs with uniform QW widths and composition by heteroepitaxy on the well-ordered nanotube arrays. Importantly, the wavelength-invariant electroluminescence emission was observed above a turn-on of 3.0 V because both the quantum-confinement Stark effect and band filling were suppressed due to the lack of spontaneous inherent electric field in the m-plane nanotube nonpolar MQWs. Lastly, the method of fabricating the multishell nanotube LED microarrays with controlled emission colors has potential applications in monolithic nonpolar photonic and optoelectronic devices on commonly used c-sapphire and Si substrates.

36 MATERIALS SCIENCE↗

Fabrication of Detector Arrays for the SPT-3G Receiver

The South Pole Telescope third-generation (SPT-3G) receiver was installed during the austral summer of 2016–2017. It is designed to measure the cosmic microwave background across three frequency bands centered at 95, 150, and 220 GHz. The SPT-3G receiver has ten focal plane modules, each with 269 pixels. Each pixel features a broadband sinuous antenna coupled to a niobium microstrip transmission line. In-line filters define the desired band-passes before the signal is coupled to six bolometers with Ti/Au/Ti/Au transition edge sensors (three bands × two polarizations). In total, the SPT-3G receiver is composed of 16,000 detectors, which are read out using a 68 × frequency-domain multiplexing scheme. In this paper, we present the process employed in fabricating the detector arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Focal-plane detector system for the KATRIN experiment

Here, the local plane detector system for the KArlsiuhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high vacuum system, a high vacuum system, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system, It is designed to detect the low-energy electrons selected by the KATRIN main spectrometer. We describe the system and summarize its performance after its final installation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Grating-coupled mid-infrared light emission from tensilely strained germanium nanomembranes

Mechanically stressed nanomembranes are used to demonstrate mid-infrared interband light emission from Ge within the 2.1–2.5 μm atmospheric transmission window. Large biaxial tensile strain is introduced in these samples to convert Ge into a (near-) direct-bandgap semiconductor and to red-shift its luminescence. A diffractive array of Ge pillars is used to outcouple the long-wavelength interband radiation, which is otherwise primarily emitted in the sample plane. An order-of-magnitude strain-induced enhancement in radiative efficiency is also reported, together with the observation of luminescence signatures associated with photonic-crystal cavity modes. These results are promising for the development of silicon-compatible lasers for mid-infrared optoelectronics applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Tuning the inductance of Josephson junction arrays without SQUIDs

It is customary to use arrays of superconducting quantum interference devices (SQUIDs) for implementing magnetic field-tunable inductors. Here, we demonstrate an equivalent tunability in a (SQUID-free) array of single Al/AlOx/Al Josephson tunnel junctions. With the proper choice of junction geometry, a perpendicularly applied magnetic field bends along the plane of the superconductor and focuses into the tunnel barrier region due to a demagnetization effect. Consequently, the Josephson inductance can be efficiently modulated by the Fraunhofer-type supercurrent interference. The elimination of SQUIDs not only simplifies the device design and fabrication but also facilitates a denser packing of junctions, and, hence, a higher inductance per unit length. As an example, we demonstrate a transmission line, the characteristic impedance of which is field-tuned in the range of 4–8 kΩ, centered around the important value of the resistance quantum h/(2e)2≈6.5 kΩ.

Physics↗

FAR-INFRARED PROPERTIES OF LYMAN BREAK GALAXIES FROM COSMOLOGICAL SIMULATIONS

Utilizing state-of-the-art adaptive mesh refinement cosmological hydrodynamic simulations with ultra-high resolution (114 h{sup -1} pc) and a large sample size ({>=}3300 galaxies of stellar mass {>=}10{sup 9} M{sub Sun }), we show how the stellar light of Lyman break galaxies at z = 2 is distributed between optical/ultraviolet (UV) and far-infrared (FIR) bands. With a single scalar parameter for dust obscuration we can simultaneously reproduce the observed UV luminosity function for the entire range (3-100 M{sub Sun} yr{sup -1}) and extant FIR luminosity function at the bright end ({>=}20 M{sub Sun} yr{sup -1}). We quantify that galaxies more massive or having higher star formation rate (SFR) tend to have larger amounts of dust obscuration mostly due to a trend in column density and in a minor part due to a mass (or SFR)-metallicity relation. It is predicted that the FIR luminosity function in the range SFR = 1-100 M{sub Sun} yr{sup -1} is a power law with a slope of about -1.7. We further predict that there is a 'galaxy desert' at SFR{sub FIR} < 0.02(SFR{sub UV}/10 M{sub Sun} yr{sup -1}){sup 2.1} M{sub Sun} yr{sup -1} in the SFR{sub UV} - SFR{sub FIR} plane. Detailed distributions of SFR{sub FIR} at a fixed SFR{sub UV} are presented. Upcoming observations by the Atacama Large Millimeter Array should test this model. If confirmed, it validates the predictions of the standard cold dark matter model and has important implications on the intrinsic SFR function of galaxies at high redshift.

79 ASTRONOMY AND ASTROPHYSICS↗

Gap solitons in rocking optical lattices and waveguides with undulating gratings

We report results of a systematic analysis of the stability of one-dimensional solitons in a model including the self-repulsive or attractive cubic nonlinearity and a linear potential represented by a periodically shaking lattice, which was recently implemented in experiments with Bose-Einstein condensates. In optics, the same model applies to undulated waveguiding arrays, which are also available to the experiment. In the case of the repulsive nonlinearity, stability regions are presented, in relevant parameter planes, for fundamental gap solitons and their two-peak and three-peak bound complexes, in the first and second finite band gaps. In the model with the attractive nonlinearity, stability regions are produced for fundamental solitons and their bound states populating the semi-infinite gap. In the first finite and semi-infinite gaps, unstable solitons gradually decay into radiation, while, in the second finite band gap, they are transformed into more complex states, which may represent new species of solitons. For a large amplitude of the rocking-lattice drive, the model is tantamount to that with a 'flashing' lattice potential, which is controlled by periodic sequences of instantaneous kicks. Using this correspondence, we explain generic features of the stability diagrams for the solitons. We also derive a limit case of the latter system, in the form of coupled-mode equations with a 'flashing' linear coupling.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In-beam $$\gamma $$-ray spectroscopy of $$^{94}$$Ag

Abstract A recoil-beta-tagging experiment has been performed to study the excited $$T=0$$ T = 0 and $$T=1$$ T = 1 states in the odd–odd $$N=Z$$ N = Z nucleus $$^{94}$$ 94 Ag, populated via the $$^{40}$$ 40 Ca( $$^{58}$$ 58 Ni,1p3n) $$^{94}$$ 94 Ag reaction. The experiment was conducted using the MARA recoil separator and JUROGAM3 array at the Accelerator Laboratory of the University of Jyväskylä. Through correlating fast, high-energy beta decays at the MARA focal plane with prompt $$\gamma $$ γ rays emitted at the reaction target, a number of transitions between excited states in $$^{94}$$ 94 Ag have been identified. The timing characteristics of these transitions confirm that they fall within decay sequences that feed the short-lived $$T=1$$ T = 1 ground state of $$^{94}$$ 94 Ag. The transitions are proposed to proceed within and between the sets of states with $$T=0$$ T = 0 and $$T=1$$ T = 1 . Possible correspondence between some of these transitions from analog states in $$^{94}$$ 94 Pd has been discussed, and shell-model calculations including multipole and monopole electromagnetic effects have been presented, in order to enable predictions of the decay patterns between the $$T=0$$ T = 0 and $$T=1$$ T = 1 states and to allow a theoretical set of Coulomb energy differences to be calculated for the $$A = 94$$ A = 94 $$T=1$$ T = 1 analog states.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Holographic optical assembly and photopolymerized joining of planar microspheres

The aim of this research is to demonstrate a holographically driven photopolymerization process for joining colloidal particles to create planar microstructures fixed to a substrate, which can be monitored with real-time measurement. Holographic optical tweezers (HOT) have been used to arrange arrays of microparticles prior to this work; here we introduce a new photopolymerization process for rapidly joining simultaneously handled microspheres in a plane. Additionally, we demonstrate a new process control technique for efficiently identifying when particles have been successfully joined by measuring a sufficient reduction in the particles’ Brownian motion. Furthermore, this technique and our demonstrated joining approach enable HOT technology to take critical steps toward automated additive fabrication of microstructures.

36 MATERIALS SCIENCE↗

Relativistic Stern-Gerlach Interaction in an RF Cavity

The general expression of the Stern-Gerlach (SG) force is deduced for a relativistic charged spin-1/2 particle which travels inside a time varying magnetic field. This result was obtained either by means of two Lorentz boosts or starting from Dirac's equation. Then, the utilization of this interaction for attaining the spin states separation is reconsidered in a new example using a new radio-frequency arrangement. On the basis of the previous estimates, we feel ready to propose the time varying SG interaction as a method for attaining a spin state separation of an unpolarized beam of, say (anti)protons, since the energy of particles with opposite spin orientations will differ and beams in the two states can be separated. In a first stage of the study of a sensible practical design, we intend to proceed with numerical simulations. As a first step, we intend to verify the correctness of Eqs.(42) and (43) setting once {beta}{sub ph} = 2 and then {beta}{sub ph} = 3, in a cavity where the field line pattern can be realistically controlled. Beyond the verification of the present theory, there is also the aim of studying the effects generated by the spin precession inside the cavity, that we did not yet address in this note. Next, we shall consider a spin splitter scheme based on the lattice of an existing or planned (anti)proton ring endowed with an array of splitting cavities. The principal aim of the latter implementations is to check the mixing effect of the longitudinal phase-plane filamentation, i.e. the actual foe which could frustrate the entire spin splitting process.

43 PARTICLE ACCELERATORS↗

Estimation of position resolution for DOI-PET detector using diameter 0.2 mm WLS fibers

We have been developing sub mm resolution and $ 1 million DOI-PET detector using wavelength shifting fibers (WLSF), scintillation crystals of plate shape and SiPM (MPPC: HAMAMATSU K. K.). Conventional design of DOI-PET detector is obtained about mm{sup 3} of resolution by using some blocks detecting gamma-ray in mm 3 voxel. It requires the production cost of $ a few ten million or more for high technique of processing crystal and a lot of number of photo-devices, and this technology is reaching the limit of the resolution. Both higher resolution and lower cost of DOI-PET detector production is challenging for PET diagnosis population. We propose two type of detector. One is a whole body PET system, and the other for brain or small animal. Both PET system consist 6 blocks. the former consist of 6 layers 300 mm x 300 mm x 4 mm crystal plate. The latter consist 16 crystal layers, 4 x 4 crystal array. The size of crystal plate is 40 mm x 40 mm x 1 mm.The WLSF sheets connect to upper and lower plane. The whole PET systems connect 8 SiPMs are bonded on each side. For the brain PET, 9 WLSF fibers are bond on the each side. The expected position resolution maybe less than 1 mm at the former. We have estimation experimental performance the system using {sup 22}Na radioactive source. The collection efficiency of WLSF (R-3) sheet was achieved 10% with GAGG at 511 keV. The relation between reconstruction position and incident position is obtained linearity and achieved the resolution of 0.7 mm FWHM for x-axis of DOI by readout WLSF. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial modulation of in-plane magnetic anisotropy in epitaxial Co(111) films grown on macrostep-bunched Si(111)

We compared magnetic properties of epitaxial Co(111) films grown on microstep- and macrostep-bunched vicinal Si(111) substrates. A surface of the microstep-bunched Si(111) substrate represents regular array of step-bunches with height of 1.7 nm divided from each other by flat microterraces with a width of 34 nm. A surface of the macrostep-bunched Si(111) substrate is constituted by macrostep bunches with a height of 75–85 nm divided by atomically flat macroterraces. The average sum width of a macrostep bunch and a macroterrace is 2.3 μm. While in-plane magnetic anisotropy was spatially uniform in Co(111) films grown on the microstep-bunched Si(111), periodic macromodulation of the topography of the Si(111) substrate induced spatial modulation of in-plane magnetic anisotropy in Co(111) film grown on the macrostep-bunched Si(111) surface. The energy of uniaxial magnetic anisotropy in the areas of the Co(111) film deposited on the Si(111) macrosteps was higher more than by the order of magnitude than the energy of the magnetic anisotropy in the areas grown on macroterraces. Magnetization reversal in the areas with different energy of the magnetic anisotropy occurred in different magnetic fields. We showed the possibility of obtaining high density of domain walls in Co(111) film grown on the macrostep-bunched Si(111) by tuning the spatial step density of the Si(111) substrate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantitative insights into the dislocation source behavior of twin boundaries suggest a new dislocation source mechanism

Pop-in statistics from nanoindentation with spherical indenters are used to determine the stress required to activate dislocation sources in twin boundaries (TBs) in copper and its alloys. The TB source activation stress is smaller than that needed for bulk single crystals, irrespective of the indenter size, dislocation density and stacking fault energy. Because an array of pre-existing Frank partial dislocations is present at a TB, we propose that dislocation emission from the TB occurs by the Frank partials splitting into Shockley partials moving along the TB plane and perfect lattice dislocations, both of which are mobile. The proposed mechanism is supported by recent high resolution transmission electron microscopy images in deformed nanotwinned (NT) metals and may help to explain some of the superior properties of nanotwinned metals (e.g. high strength and good ductility), as well as the process of detwinning by the collective formation and motion of Shockley partial dislocations along TBs.

36 MATERIALS SCIENCE↗

SU-E-T-80: Comparison of Fluence-Based RapidArc QAs Using EPID and MapCHECK 2

Purpose: To compare the Varian aS-1000 EPID imager to the isocentrically mounted MapCHECK 2 diode array for RapidArc QAs as a function of photon beam energy. Methods: A Varian TrueBeam STx with an aS-1000 digital imaging panel was used to acquire RapidArc QA images for 13 patient plans; each plan QA was performed at 6, 8, 10 and 15MV energies. The Portal Dose Image Prediction algorithm in the Varian Eclipse treatment planning system (TPS) was used to create the comparison image for the EPID acquisition. A Sun Nuclear MapCHECK 2 diode array on an isocentric mounting fixture with 5 cm water-equivalent buildup was also used for the RapidArc QAs. A composite dose plane was taken from the Eclipse TPS for comparison to the MapCHECK 2 measurements. A gamma test was implemented in the Sun Nuclear Patient software with 10% threshold and absolute comparison for both QA methods. The two-tailed paired t-test was employed to analyze the statistical significance between two methods at the 95% confidence level. Results: The average gamma passing rates were greater than 95% at 3%/3mm using both methods for all four energies. The average passing rates were within 2.5% and 1.1% of each other when analyzed at 2%/2mm and 3%/3mm conditions, respectively. The EPID passing rates were somewhat better than the MapCHECK 2 when analyzed at 1%/1mm condition; this difference decreased with increasing energy (9.1% at 6MV to 2.7% at 15MV). The differences were not statistically significant for all criteria and energies (p-value ã 0.05). Conclusion: EPID-based RapidArc QA results are comparable to MapCHECK 2 when using 3%/3mm criteria at all four energies. EPID-based QA shows potential for being the superior device under strict gamma criteria.

60 APPLIED LIFE SCIENCES↗

SU-E-T-05: A 2D EPID Transit Dosimetry Model Based On An Empirical Quadratic Formalism

Purpose: To describe a 2D electronic portal imaging device (EPID) transit dosimetry model, based on an empirical quadratic formalism, that can predict either EPID or in-phantom dose distribution for comparisons with EPID captured image or treatment planning system (TPS) dose respectively. Methods: A quadratic equation can be used to relate the reduction in intensity of an exit beam to the equivalent path length of the attenuator. The calibration involved deriving coefficients from a set of dose planes measured for homogeneous phantoms with known thicknesses under reference conditions. In this study, calibration dose planes were measured with EPID and ionisation chamber (IC) in water for the same reference beam (6MV, 100mu, 20×20cm{sup 2}) and set of thicknesses (0–30cm). Since the same calibration conditions were used, the EPID and IC measurements can be related through the quadratic equation. Consequently, EPID transit dose can be predicted from TPS exported dose planes and in-phantom dose can be predicted using EPID distribution captured during treatment as an input. The model was tested with 4 open fields, 6 wedge fields, and 7 IMRT fields on homogeneous and heterogeneous phantoms. Comparisons were done using 2D absolute gamma (3%/3mm) and results were validated against measurements with a commercial 2D array device. Results: The gamma pass rates for comparisons between EPID measured and predicted ranged from 93.6% to 100.0% for all fields and phantoms tested. Results from this study agreed with 2D array measurements to within 3.1%. Meanwhile, comparisons in-phantom between TPS computed and predicted ranged from 91.6% to 100.0%. Validation with 2D array device was not possible for inphantom comparisons. Conclusion: A 2D EPID transit dosimetry model for treatment verification was described and proven to be accurate. The model has the advantage of being generic and allows comparisons at the EPID plane as well as multiple planes in-phantom.

60 APPLIED LIFE SCIENCES↗

Development of an Integrated Multidiagnostic to Assess the High-Z Impurity Fluxes in the Metallic Environment of WEST Using IMAS

WEST is an actively cooled, long-pulse tokamak with nearly all plasma-facing components (PFC) made of tungsten. One of the aims of WEST is to study plasma operations with tungsten PFCs in preparation for long-pulse operations on high-Z divertor devices, such as ITER. For long-pulse operation, the high-Z impurity content and transport to the core plasma are critical concerns that require further measurement and interpretation to improve plasma performance and PFC durability. This work details the impurity influxes in WEST during a series of discharges in which the lower hybrid (LH) injected power was incrementally increased. An analysis has been performed of measurements collected from an array of edge diagnostics. Visible spectroscopy was utilized to measure the spectral radiances generated by fuel particles (D) and impurities (W, O, and C) at the divertor and at the antennas with a newly developed spectral peak-fitting tool used to analyze the data in WEST. The scrape-off layer (SOL) plasma conditions (n e and T e ) measured at the divertor target with flush Langmuir probes and near the outer mid-plane (OMP) using reciprocating Langmuir probes (RCPs) are used to evaluate the number of ionizations per photons (S/XB) coefficients required to estimate the impurity fluxes obtained with the collisional-radiative model ColRadPy. Here, the array of edge diagnostics discussed in this work, coupled with SOL plasma modeling tools, represents a multidiagnostic interpretative modeling workflow that will continue to be applied to upcoming experimental campaigns on the WEST experiment to assess high-Z impurity transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Innovations in optical coupling of the KSTAR electron cyclotron emission imaging diagnostic

The installation of a new electron cyclotron emission imaging diagnostic for the Korea Superconducting Tokamak Advanced Research (KSTAR) is underway, making use of a unique optical port cassette design, which allows placement of refractive elements inside the cryostat region without adverse effects. The result is unprecedented window access for the implementation of a state of the art imaging diagnostic. A dual-array optical design has been developed, capable of simultaneously imaging the high and low field sides of the plasma with independent features of focal plane translation, vertical zoom, and radial channel spacing. The number of translating optics has been minimized by making use of a zoom lens triplet and parabolic plasma facing lens for maximum channel uniformity over a continuous vertical zoom range of 3:1. The simulated performance of this design is presented along with preliminary laboratory characterization data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗