Search NASA⌕ Search

SEARCH · Search NASA

Results for “probing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Exploring the Atmosphere of Uranus with Small Next-generation Atmospheric Probe (SNAP)

In-situ atmospheric exploration of giant planets is a top priority of the planetary science community and NASA. The Galileo Probe a Jupiter made the first and only in-situ composition measurements of the atmosphere. Most importantly, the noble gas and isotopic ratio can be made only through in-situ measurements, and the Galileo Probe measurements must be followed up by similar measurements at Saturn, Uranus, and Neptune. In addition, abundances of condensable cloud-forming species are also needed to measure the vertical distribution of those molecules to provide ground-truths measurements for remote-sensing measurements. My talk will focus on the Small Next-generation Atmospheric Probe (SNAP) design developed in partnership by Hampton University and NASA Langley Research Center to enable delivery of multiple probes. Using SNAP as a reference design, I will also discuss key instrument trades and the state of the art in the atmospheric composition instruments.

Kunio Sayanagi↗

Analysis of Probe Surveys Conducted in the 10-MW TP3 Arc-Jet Facility 15-Inch Nozzle Flow

Computational simulations and analysis of flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center are reported. These tests were conducted in the 10-MW TP3 facility 15-inch conical nozzle, and pitot pressure and heat flux probes are used to survey test flow downstream of the nozzle exit. Two 1.59-cm (0.625 in) diameter hemisphere probes were used: one with a stagnation-point pressure port, the other with a Gardon heat flux gage. Calibration data were also obtained using 20.32-cm flat-faced slug calorimeters. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were obtained at eight arc-heater conditions, covering wide ranges in arc current (316–1756 A) and mass flow rate (32–500 g/s, without any cold-gas injection at the arc-heater plenum) and providing assessment of the flow uniformity in the facility. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. These simulations take into account non-uniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields. Comparisons of computations with the experimental measurements are presented, showing reasonably good agreement. The probe survey data and accompanying analysis show that the test flow in the TP3 15-inch nozzle is highly non-uniform at most conditions, and the extent of flow non-uniformity depends on arc current and mass flow rate.

Arc-jets↗

Gravity Poppers: Hopping Probes for the Internal Mapping of Small Solar System Bodies

This paper presents the results of NIAC Phase I study into the feasibility of a novel mission architecture for highresolution gravity science on small Solar System bodies. The “Gravity Poppers” mission concept (see Fig. 1) consists of a swarm of small, minimalistic probes that are deployed from a mother spacecraft to the surface of a small body and which periodically and randomly hop around the surface. By tracking the ballistic sub-orbital trajectories of this hopping swarm, a very high resolution gravity field can be measured, which can then be used to answer a number of scientific questions of interest regarding the interior mass distribution of the body. This paper describes the three core focus areas of our study to demonstrate concept feasibility: (1) the design of hopping probes to be small, simple, robust, and “visible” to a distant spacecraft, (2) the tracking strategy for detecting and estimating the trajectories of a large number of ballistic probes, and (3) the algorithmic framework by which such measurements can be used to estimate the body’s gravity field. Our results suggest the ability to estimate the gravity field of a 500m asteroid beyond degree-and-order 40 through days to weeks of optical tracking of several LED-strobing probes, with a mass of only 200 g each. Collectively, this study demonstrates that the high-resolution gravity mapping of small body interiors is technically possible, economically feasible, and would enable a compelling set of science objectives aligned with NASA’s goals in planetary science, planetary defense, and future interests in resource prospecting.

McMahon, Jay↗

Micrometer to Atomic Scale Characterisation of Primitive Astromaterials Using A Novel Method, Metis-Fa: A Coordinated Atom Probe Tomography, Transmission Electron Microscopy and NanoSIMS Approach

Introduction: Presolar grains preserve isotopic, chemical and microstructural records of physical and chemical processing, and formation mechanisms within a vast range of evolved stellar systems, the interstellar medium, solar nebula and their parent bodies. These evolutionary records are preserved at the micrometric to atomic scale, requiring coordinated studies to expand our understanding of evolutionary processes occurringthroughout ours and external stellar systems [1]. NanoSIMS enabled rapid in situ identification and isotopic characterisation of presolar grains and their stellar origins using 17O/16O and 18O/16O, and 13C/12C isotopic ratios [1]. Coordination with transmission electron microscopy (TEM) revealed crystallographic and localised contextual relationships and quantitively constrained their major and minor compositions [1]. However, trace elements cannot be quantified, the most sensitive geochemical tracers of environmental conditions, essential to unravelling the chemical record of their evolutionary pathway and parent stellar systems [2-3] . Furthermore, owing to the combination of technical limitations (only 5 – 7 isotopes can be measured per NanoSIMS run) and their small grain sizes of 100 nm < 3 μm (with rare exceptions in nanodiamonds (2 nm ≤) and SiC (< 40 μm)), the number of measurable isotopes per grain volume is limited [1,3] . Through more comprehensive isotopic studies of presolar grains, NanoSIMS studies have shown the importance of the latter, identifying Fe and Mg as important indicators of nuclear synthetic processing and their stellar origins, respectively [4- 5]. Coordination of NanoSIMS and Atom Probe Tomography (APT) revealed morphological signatures, and isotopic and chemical signatures at major to trace levels without requirements for preselection of elements [6]. However, crystallographic signatures in localized contextual relationships cannot be measured. Consequently, coordination of NanoSIMS, TEM and APT is essential to gain access to almost all contextual, structural and geochemical signatures within each presolar grain.Transmission electron microscopy requires a 100 nm thin lamella which is unstable in APT and would not produce any viable data. Atom probe tomography requires a needle-shaped specimen which when measured in TEM removes the local context, impacts the quality of the TEM diffraction images due to the shank angle of the needle, and can alter the chemistry of beam sensitive materials from the higher degree of surface exposure at the tip. To address these issues, we developed METIS-Fa (Multi-technical measurements of Electron Transparent materials using an Indium Sandwich - a FIB approach). A novel method which enables coordination of NanoSIMS, TEM and APT for generalized and targeted studies of individual grains, including beam sensitive materials, without compromising sample preparation requirements for TEM and APT. This method requires only indium and a Focus Ion Beam (FIB), minimizing the movement of fragile materials while still enabling preparation of TEM lamella into APT needles. Samples: Initial experimental development and testing of the method occurred at Astromaterials Research and Exploration Science (ARES), Johnson Space Centre (JSC), NASA and APT measurements and needle preparation occurred at JdLC, Curtin University. Synthetic silicate samples were used as analogs for presolar silicates when performing a trial run of the method. Samples were extracted from a polished thin section created at JSC, NASA, comprised of 38 wt.% Si, 17 wt.% FeO, 13 wt.% MgO, 12 wt.% Al, 11 wt.% Ca based on electron microprobe analysis (EMPA) [8] . Experimental details, pressure and temperature conditions were presented in [8] and references therein. Testing of the capability to target individual grains in mineral matrices using this method for acquisition in APT, measured matrix regions in meteoritic thin sections of primitive meteorites. These meteorites and their identified presolar grains for future targeted studies are detailed in [9]. Techniques: The TEM-FIB lamella were prepared using a FIB. An e-beam assisted pt deposition was used as a protective coating for the synthetic and meteoritic samples. When targeting individual grains, a secondary e-beam assisted pt deposition button is placed over the desired grain before the protective coating to denote its location. A JEOL 2500SE field-emission TEM was used for high-resolution imaging, energy-dispersive X-ray (EDX) and electron diffraction data.TheMETIS-Fa method was experimentally designed, tested and executed using a FIB at ARES, JSCNASA. Needles for APT were prepared using the Tescan Lyra3 GM Dual Beam Focus Ion Beam (FIB) Field Emission SEM (FE-SEM) at the JdLC, Curtin University. Atom probe tomography measurements were conducted using a CAMECA Local Electrode Atom Probe, LEAP 4000X HR. Two pure indium needles were analyzed initially to constraining acquisition parameters and stability under the beam. Manual acquisition was required to maintain evaporation of specimen’s at the apex and monitor interactions with measurement parameters. Experimental Design: Indium foil is pressed onto an Al stub with a pneumatic press and mounted into the FIB adjacent to the TEM-FIB lamella of interest. Using a FIB, two indium slices (5 μm x ~300 nm x 3 μm) are extracted from indium foil and aligned with the TEM-FIB lamella before touching the TEM-FIB lamella. Each slice is then attached through cold welding to the FIB-TEM lamella. This approach eliminates the need for chemical treatments and proved effective for aligning the Indium within the region of interest for APT, holding it in place for up to 4 days during testing.Once both indium slices are attached within their pre-determined region per grain targeting requirements, they are gradually melted onto the FIB-TEM lamella.When targeting a specific grain, measurements should be taken of the pt button and its distance from edge to edge of the lamella before and after sandwiching. A secondary button should be placed over the same region after the Indium slices have been attached to improve precision when preparing APT needles. Results: Figure 1 shows two indium slices melted onto a FIB-TEM lamella, adding additional bulk for preparation into APT needles as shown in Figure 2 [7] . The latter was essential so samples could be measured in TEM and APT without compromising sample preparation requirements and consequently data quality and acquisition stability. METIS-Fa proved effective forimproving geometry. Figure 3 shows a successful APTrun of the synthetic silicate. EMPA, TEM and APTshowed no chemical alterations. During targetingtesting, a solar silicate grain was successfully identifiedand measured in TEM, and prepared into an APTneedle. However, the indium was melted too long during sample preparation, causing expansion andformation of internal porosity leading to sample loss.Conclusion: METIS-Fa greatly expands the number of isotopic and chemical signatures measured per grain volume, and enables measurements of contextual, structural, crystallographic, isotopic and geochemical signatures within individual grains. Gaining access to such a vast range of evolutionary signatures required for expanding our understanding of external stellar and planetary systems and the evolution of our solar system. This method was designed for application to a vast range of phases including being sensitive materials and thus provides a way for coordination of NanoSIMS, TEM and APT not just for the study of presolar grains and by extension primitive astromaterials, but studies in a vast range of other fields including the geosciences and material sciences.Acknowledgments: Thankyou to ARES, JSC, NASA; JdLC Curtin University and Space Science Technology Centre for the use of laboratory facilities and funding [confirm].

Nicole D Nevill↗

Analysis of Hot-Wire Probe Ice Water Content Measurements in High Ice Water Content Conditions

During the 2022 High Ice Water Content (HIWC) Flight Campaign, ice water content (IWC) measurements were made at various locations on the NASA DC-8 Airborne Science Laboratory using the Isokinetic Probe Version 2 (IKP2), Ice Crystal Detectors (ICD), and Robust Probe. Correlations of a wing mounted ICD to IKP2 were made to determine the collision/retention efficiency of the ICD total water content (TWC) element in glaciated conditions. Similarly, correlations of a nose mounted ICD near the pitot probes were made to the IKP2 and to the wing-mounted ICD to estimate the ice concentration factor near the DC-8 pitot probes. Results from the 2022 flight campaign were compared to results from the HIWC RADAR II flight campaign in 2018. There was an apparent reduction in the ICD TWC collision/retention efficiency during the 2022 flight campaign. Although reasons for this discrepancy were explored, more analyses are needed to fully understand the causes. However, it was concluded that an estimated ice concentration factor at the nose of 2.5 was consistent between the two flight campaigns. Additionally, a correlation model was developed to relate measurements from a Nose ICD to freestream IWC as measured by the IKP2 to support IWC measurements from the 2022 Convective Processes Experiment - Cabo Verde (CPEX-CV) flight campaign.

Icing↗

Analysis of Hot-Wire Probe Ice Water Content Measurements in High Ice Water Content Conditions

During the 2022 High Ice Water Content (HIWC) Flight Campaign, ice water content (IWC) measurements were made at various locations on the NASA DC-8 Airborne Science Laboratory using the Isokinetic Probe Version 2 (IKP2), Ice Crystal Detectors (ICD), and Robust Probe. Correlations of a wing mounted ICD to IKP2 were made to determine the collision/retention efficiency of the ICD total water content (TWC) element in glaciated conditions. Similarly, correlations of a nose mounted ICD near the pitot probes were made to the IKP2 and to the wing-mounted ICD to estimate the ice concentration factor near the DC-8 pitot probes. Results from the 2022 flight campaign were compared to results from the HIWC RADAR II flight campaign in 2018. There was an apparent reduction in the ICD TWC collision/retention efficiency during the 2022 flight campaign. Although reasons for this discrepancy were explored, more analyses are needed to fully understand the causes. However, it was concluded that an estimated ice concentration factor at the nose of 2.5 was consistent between the two flight campaigns. Additionally, a correlation model was developed to relate measurements from a Nose ICD to freestream IWC as measured by the IKP2 to support IWC measurements from the 2022 Convective Processes Experiment - Cabo Verde (CPEX-CV) flight campaign.

Icing↗

Probing and manipulating magnetic and 2D quantum materials using ultrafast laser and high harmonic sources

The ability to probe the full dynamic response of quantum materials on the length- and time-scales (Å to attoseconds on up) fundamental to charge, spin and phonon interactions is leading to a host of new discoveries. The coupled interactions between charges, spins, orbital and lattice degrees of freedom are key to determining the state of a material, whether metallic, insulating, superconducting or magnetic. Under thermal equilibrium conditions these states can be tuned by varying the temperature, pressure, chemical doping or dimensionality. However, their inherent complexity and rich phase landscape make them challenging to understand or manipulate deterministically. Fortunately, ultrafast light sources have undergone remarkable advances in recent years, achieving what was merely a dream three decades ago, i.e., full coherent control of light fields spanning the THz to the X-ray regions. Here, these new capabilities are providing powerful new tools for coherently manipulating and probing quantum materials using light. Recent advances in high harmonic generation (HHG) have provided new techniques for uncovering new phases and couplings in 2D and magnetic materials, using femtosecond lasers to coherently manipulate and tune the properties and interactions in the material, and HHG as a probe to map out these new phases and couplings. There are several beautiful recent observations of exciting new states in materials using light, but in some cases, the limited experimental data points made it challenging to validate an interpretation. The new ability of ultrafast HHG-based photoemission and magneto-optic spectroscopies to precisely probe multiple phases, electronic and magnetic order parameters, when combined with scanning the laser excitation fluence, is allowing us to map how material phases, magnetic states, and electron-phonon-spin couplings in these delicate materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultrafast, multiphoton-pump, multiphoton-probe spectroscopy

Methods for pump-probe spectroscopy are provided. In an embodiment, such a method comprises directing pump light having a frequency ωpump at a location in a sample to excite a transition between two quantum states of a target entity in the sample, directing probe light at the location to generate a coherent output signal having a frequency ωoutput and a wavevector koutput, and detecting the output signal as the probe light is scanned over a range of frequencies. In the method, either the transition excited by the pump light is a multiphoton transition corresponding to a frequency difference of n*ωpump, wherein n≥2; or the probe light is a set of m coherent light pulses, each coherent light pulse having a frequency ωm and a wavevector km, wherein m≥2; or both. Systems for carrying out the methods are also provided.

Morrow, Darien James↗

Cryo nanomanipulator probe with integrated gas injection

A probe assembly for use with a charged particle instrument includes an elongate body having a proximal end for positioning outside of a charged particle instrument enclosed environment, a distal end for positioning within the enclosed environment and a longitudinal axis. A port interface is located on the body between the proximal and distal ends, and is coupleable to a nanomanipulator system of the charged particle instrument. A probe needle is positioned at a distal end of the body and is selectively positionable from outside the enclosed environment to contact a specimen within the enclosed environment. At least one gas injection needle is adjustably positioned near the probe needle. The gas injection needle is connectable to a source of pressurized gas to selectively inject gas in the area of the probe needle within the enclosed environment.

Perea, Daniel E.↗

Probe for selectively characterizing enzymes involved in xenobiotic metabolism and method of making and using the same

Activity-based probes that can be used to selectively identify and characterize enzymes that are involved in different phases of xenobiotic metabolism in a host and its microbiota population(s) are described. The activity-based probes described specifically label only their target active enzymes involved in xenobiotic metabolism and therefore provide a measurement of true protein functional activity rather than transcript or protein abundance. The activity-based probes also provide multimodal profiling of these active enzymes. Methods for preparing the activity based probes and exemplary methods for their use also are disclosed.

Wright, Aaron T.↗

Capture probe

A system and method for sampling a sample material includes a device for directing sample into a capture probe. The device for supplying sample material to the probe can be a device for radiating energy to the surface to eject sample from the sample material. A probe includes an outer probe housing having an open end. A liquid supply conduit has an outlet positioned to deliver liquid to the open end. An exhaust conduit removes liquid from the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust system can be in fluid connection with the liquid exhaust conduit for removing liquid from the liquid exhaust conduit at a second volumetric flow rate such that gas with sample is withdrawn with the liquid.

Kertesz, Vilmos↗

System and method for sub-wavelength detection for jetting-based additive manufacturing using a split ring resonator probe

The present disclosure relates to a system for detecting and analyzing droplets of feedstock material being ejected from an additive manufacturing device. The system makes use of a split ring resonator (SRR) probe including a ring element having a gap, with the gap being positioned adjacent a path of travel of the droplets of feedstock material. An excitation signal source is used for supplying an excitation signal to the SRR probe. An analyzer analyzes signals generated by the SRR probe in response to perturbations in an electric field generated by the SRR probe as the droplets of feedstock material pass the ring element. The signals are indicative of dimensions of the droplets of feedstock material.

Mukherjee, Saptarshi↗

Probe for selectively characterizing enzymes involved in xenobiotic metabolism and method of making and using the same

Activity-based probes that can be used to selectively identify and characterize enzymes that are involved in different phases of xenobiotic metabolism in a host and its microbiota population(s) are described. The activity-based probes described specifically label only their target active enzymes involved in xenobiotic metabolism and therefore provide a measurement of true protein functional activity rather than transcript or protein abundance. The activity-based probes also provide multimodal profiling of these active enzymes. Methods for preparing the activity based probes and exemplary methods for their use also are disclosed.

Wright, Aaron T.↗

Capture probe

A system and method for sampling a sample material includes a device for directing sample into a capture probe. The device for supplying sample material to the probe can be a device for radiating energy to the sample material to eject sample from the sample material. A probe includes an outer probe housing having an open end. A liquid supply conduit has an outlet positioned to deliver liquid to the open end. An exhaust conduit removes liquid from the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust system can be in fluid connection with the liquid exhaust conduit for removing liquid from the liquid exhaust conduit at a second volumetric flow rate such that gas with sample is withdrawn with the liquid.

Kertesz, Vilmos↗

Constraints on Dynamical Dark Energy from Multiple Probes in the Full Dark Energy Survey

We present results on dark energy evolution, assuming a time-dependent equation of state $w(a)=w_0+w_a(1-a)$, from growth and geometric probes using the full six-year Dark Energy Survey dataset: type Ia supernovae, baryon acoustic oscillations, and weak gravitational lensing and galaxy clustering (3$\times$2pt). The combination yields $w_0=-0.84^{+0.10}_{-0.10}$ and $w_a=-0.44^{+0.60}_{-0.55}$, the tightest constraints ever obtained from a single survey, with $2.2σ$ deviation from a cosmological constant. Adding the DESI DR2 BAO data yields $w_0=-0.84^{+0.06}_{-0.07}$ and $w_a=-0.53^{+0.33}_{-0.28}$, representing the most stringent low-redshift-only test of dynamical dark energy to date, with a $2.3σ$ deviation. In this combination, adding 3$\times$2pt doubles the constraining power. Finally, when combined with primary CMB information, we obtain $w_0=-0.82^{+0.05}_{-0.05}$, $w_a=-0.63^{+0.21}_{-0.18}$, with a $3.0σ$ deviation. We find that including 3$\times$2pt in the previously studied SN + DESI BAO + CMB combination leaves the significance essentially unchanged ($3.2 σ$ to $3.0σ$) while improving the figure of merit by $\sim$10%. We systematically investigate the impact of leaving out each one of the probes and find that the significance of the deviation from a cosmological constant ranges from 2.3 to 3.2$σ$, with best-fit parameters consistently in the region $w_0 >-1$ and $w_a <0$. Excluding SN from the all data combination yields a $2.6σ$ departure from $Λ$CDM, providing a cross-check independent of supernova photometric calibration. These results support the weak preference for evolving dark energy reported by several recent cosmological analyses. By combining growth and geometric probes from a single survey, this work realizes the multi-probe dark energy program envisioned at the inception of DES.

Abbott, T. M.C. [Cerro-Tololo InterAmerican Obs.] ↗

New frontiers in atom probe tomography: a review of research enabled by cryo and/or vacuum transfer systems

There has been a recent surge in the use of cryo and/or vacuum specimen preparation and transfer systems that are broadening the scope of research enabled by the microscopy technique of atom probe tomography. This is driven by the fact that, like for many microscopes, the application of atom probe to air and temperature sensitive materials or wet biological specimens has previously been limited by through-air-transfer and through-vacuum-transfer at room temperature. Here we provide an overview of the critical areas of research that require these new transfer and analysis protocols, as well as a review of current advances in transfer devices, environmental cells and glove boxes for controlled sample manipulation. This includes the study of catalysis and corrosion, the application of atom probe to biological samples, the study of liquid-solid interfaces, natural ageing investigations and the analysis of hydrogen in metals.

36 MATERIALS SCIENCE↗

Time-resolved probing of laser-induced nanostructuring processes in liquids

Laser synthesis and processing of colloids (LSPC) in liquids has gained widespread applications in producing nanomaterials of different classes of solids. While the technical processes in different cases of ablation, fragmentation or colloidal fusion may look macroscopically different in each application, the underlying fundamental mechanisms are always the same cascade of laser interaction with matter, non-thermal or thermal energy deposition, phase transitions, and the subsequent structure formation processes. Disentangling these mechanisms represents a veritable challenge, as ultrafast and structurally sensitive experimental methods are required. This review presents a discussion of how state-of-the-art experimental protocols using ultrafast lasers and sensitive structural probes, such as electrons or X-rays are able to address this challenge. In particular, it is possible to investigate LSPC on single objects using single probe pulses and avoid accumulation effects in a heterogeneous sample. The presented results capture structure formation with femtosecond and atomic scale resolution. Ultrafast time-resolved probing approaches are key to revealing the transient states and pathways that govern material transformation in LSPC.

X-ray scattering↗

Community-Driven Methods for Open and Reproducible Software Tools for Analyzing Datasets from Atom Probe Microscopy

Atom probe tomography, and related methods, probe the three-dimensional architecture of a material. The software tools that microscopists use, and how these tools are connected into workflows, makes a substantial contribution to the accuracy and precision of such a material characterization experiment. Typically, we adapt methods from other communities like mathematics, data science, computational geometry, artificial intelligence, or scientific computing. We also realize that improving on research data management is a challenge when it comes to align with the FAIR data stewardship principles. Faced with this global challenge, we are convinced that collaborating is useful. Here, we report the results and challenges with an inter-laboratory call for developing test cases for several types of atom probe software tools. The results support why defining detailed recipes of software workflows and sharing these recipes is necessary and rewarding: Open source tools and (meta)data exchange can help to make our day-to-day data processing tasks become more efficient, the training of new users and knowledge transfer become easier, and assist us with automated quantification of uncertainties to gain access to substantiated results.

36 MATERIALS SCIENCE↗