Search NASA⌕ Search

SEARCH · Search NASA

Results for “prototype specifications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Bamboo Bio-composite Truck/Trailer Decking

Bamboo is one of the fastest growing plants in the world. Massively productive, bamboo will maintain that productivity with limited inputs and minimal management resulting in predictable volume and operating margins and with low overhead. The goal of this project was to develop a bamboo bio-composite trailer decking product that replaces apitong, is lighter weight, stronger and luminescent. The collaboration partners, Fontaine, Resource Fiber and IACMI, worked closely to develop the bamboo bio-composite decking to Fontaine Trailer’s (end-user) specifications. The various technological objectives were (a) To conduct a comprehensive Design of Experiments study for bamboo composites to understand the structure-property relationships for different resin composites and bamboo forms (strips, woven, bulk etc); (b) To establish the nail pull out characteristics of trailer deck geometry bamboo composite form. The nail pull out is a critical test in trailer decks; (c) To design, process and prototype select number of trailer decking planks for Fontaine evaluation; and (d) To conduct life cycle analysis to conduct energy calculations from the various conversion steps of the bamboo from crop to product. The project meets DOE/IACMI metrics of reduced embodied energy, lightweighting and lowering the cost of the end product. It also offers a green solution to a value-added application, i.e. trailer decking. The development goals and benefits of bamboo composite decking included: A. Decreased weight when compared to Apitong and Gen 1, thereby reducing operating costs and petroleum usage due to increased miles per gallon. B. Flexibility to allow camber design into trailers. C. Luminescence to increase safety during low light and dark conditions. D. Composite material to maximize use of bamboo bio-composites as substitute for petroleum-based composites. E. Embedded layer(s) of conditioned bamboo for added strength and stability. F. Improved safety over Apitong by temporary cargo indentation in planks for better stability. G. Cradle-to-cradle design so end-of-life becomes beginning-of-life for other products. Resource Fiber’s bamboo biocomposite trailer decking passed nail pullout tests as compared to apitong (incumbent), was lighter weight than apitong, and used less embodied energy particularly when bamboo is sourced domestically. The planks were optimized in the lab setting to the extent possible and successfully installed on the trailer at Fontaine for field testing. Despite the process not being fully optimized due to through-heat and tooling limitations within the budget constraints, the prototype decking withstood 400 cycles of reverse fatigue loading of a 107,000 lb Caterpillar 349F which was extreme conditions of field testing by Fontaine Trailer. Resource Fiber plans to outsource production of a next round of planks with a commercial pultrusion processor, then to do a re-test with Fontaine Trailers. Tooling specific to the part is required. Long-term commercial plans are to continue outsourcing production while supplying bamboo fiber and mats. Commercial markets include heavy haul trailers, military trailers, and decking for marine, industrial and residential use.

36 MATERIALS SCIENCE↗

Defect-mediated, thermally-activated encapsulation of metals at the surface of graphite

Here, we show that 3 metals – Dy, Ru, and Cu – can form multilayer intercalated (encapsulated) islands at the graphite (0001) surface if 2 specific conditions are met: Defects are introduced on the graphite terraces to act as entry portals, and the metal deposition temperature is well above ambient. Focusing on Dy as a prototype, we show that surface encapsulation is much different than bulk intercalation, because the encapsulated metal takes the form of bulk-like rafts of multilayer Dy, rather than the dilute, single-layer structure known for the bulk compound. Carbon-covered metallic rafts even form for relatively unreactive metals (Ru and Cu) which have no known bulk intercalation compound.

36 MATERIALS SCIENCE↗

Multidisciplinary Design, Analysis, and Optimization (MDO) for Co-Designed Transmission & Distribution Electric Grid Planning

This paper describes early experiences and example use cases applying multi-disciplinary design analysis and optimization (MDO) to the integrated design of power grids. Adapted from aerospace, MDO enables combining multiple existing tools into a coordinated optimization. Here we use MDO to simultaneously capture integrated transmission-distribution and investment-engineering trade-offs in an automated framework. Example use cases showcase prototype interactions among existing grid models using MDO and hint at the types of integrated analyses enabled by this approach. In addition, we share experiences and thoughts on grid-specific challenges and opportunities to help advance further work in this area.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low Background Counting at LBNL

The Low Background Facility (LBF) at Lawrence Berkeley National Laboratory in Berkeley, California provides low background gamma spectroscopy services to a wide array of experiments and projects. The analysis of samples takes place within two unique facilities; locally within a carefully-constructed, low background cave and remotely at an underground location that historically has operated underground in Oroville, CA, but has recently been relocated to the Sanford Underground Research Facility (SURF) in Lead, SD. These facilities provide a variety of gamma spectroscopy services to low background experiments primarily in the form of passive material screening for primordial radioisotopes (U, Th, K) or common cosmogenic/anthropogenic products, as well as active screening via Neutron Activation Analysis for specific applications. The LBF also provides hosting services for general R&D testing in low background environments on the surface or underground for background testing of detector systems or similar prototyping. A general overview of the facilities, services, and sensitivities is presented. Recent activities and upgrades will also be presented, such as the completion of a 3π anticoincidence shield at the surface station and environmental monitoring of Fukushima fallout. The LBF is open to any users for counting services or collaboration on a wide variety of experiments and projects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First plasma of the A-PHOENIX electron cyclotron resonance ion source

A-PHOENIX is a new compact hybrid electron cyclotron resonance ion source using a large permanent magnet hexapole (1.92 T at the magnet surface) and high temperature superconducting Solenoids (3 T) to make min-vertical bar B vertical bar structure suitable for 28 GHz cw operation. The final assembly of the source was achieved at the end of June 2007. The first plasma of A-PHOENIX at 18 GHz was done on the 16th of August, 2007. The technological specificities of A-PHOENIX are presented. The large hexapole built is presented and experimental magnetic measurements show that it is nominal with respect to simulation. A fake plasma chamber prototype including thin iron inserts showed that the predicted radial magnetic confinement can be fulfilled up to 2.15 T at the plasma chamber wall. Scheduled planning of experiments until the end of 2008 is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sealed operation of a rf driven ion source for a compact neutron generator to be used for associated particle imaging

We present the recent development of a prototype compact neutron generator to be used in conjunction with the method of associated particle imaging for the purpose of active neutron interrogation. In this paper, the performance and device specifications of these compact generators that employ rf driven ion sources will be discussed. Initial measurements of the generator performance include a beam spot size of 1 mm in diameter and a neutron yield of 2x10{sup 5} n/s with air cooling.

43 PARTICLE ACCELERATORS↗

Linear variable differential transformer (LVDT)-based elongation measurements in Advanced Test Reactor high temperature irradiation testing

New materials are being considered for fuel, cladding and structures in next generation and existing nuclear reactors. These materials can undergo significant dimensional and physical changes during high temperature irradiations. Currently, such changes are determined by repeatedly irradiating a specimen for a specified period of time in the Advanced Test Reactor (ATR) and then removing it from the reactor for evaluation. The labor and time to remove, examine and return irradiated samples for each measurement make this approach very expensive. In addition, such techniques provide limited data and may disturb the phenomena of interest. To resolve these issues, an instrumented creep testing capability is being developed for specimens irradiated under pressurized water reactor coolant conditions in the ATR at the Idaho National Laboratory (INL). This paper reports the status of INL efforts to develop this testing capability. In addition to providing an overview of in-pile creep test capabilities available at other test reactors, this paper focuses on efforts to design and evaluate a prototype test rig in an autoclave at INL’s High Temperature Test Laboratory.

99 GENERAL AND MISCELLANEOUS↗

A System Level Comparative Study of SecondarySide Rectifiers for UAV Wireless Power Transfer in High-Altitude Airborne Energy Platforms

Wireless power transfer (WPT) systems for unmanned aerial vehicles (UAVs) must satisfy stringent design requirements to ensure reliable operation under constraints related to efficiency, thermal performance, altitude, weight, and reliability, particularly in airborne and high-altitude environments. Thermal management becomes increasingly challenging at higher altitudes due to reduced air density, while reliability is strongly affected by the number and complexity of active components. The weight and compactness of secondary-side rectifiers directly impact UAV flight endurance and system integration, influencing energy consumption and payload allocation. These factors collectively define the practical feasibility of UAV WPT systems and guide rectifier topology selection. This paper presents a comparative and experimentally validated evaluation framework for secondary-side rectifiers under UAV-specific constraints. Three representative rectifier architectures are analyzed using component-based assessment of weight, thermal behavior, and reliability, together with experimental efficiency measurements obtained from a 1 kW WPT prototype. The results show that the single-switch active rectifier achieves the highest peak efficiency of approximately 93.2% and an overall efficiency of 91%, while also offering advantages in weight and reliability. The findings demonstrate how constraint-oriented analysis, combined with experimental validation, enables informed selection of secondary-side rectifiers for UAV wireless power transfer applications, including emerging airborne and high-altitude platforms.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

VCTR: A Versatile Coupled Test Reactor Concept

The United States has currently no domestic fast neutron test and irradiation capabilities necessary to pursue a strong research and development program related to fast neutron reactors. This lack prevents the testing of fast reactor fuels in a prototypic environment, the testing of new safety features and of new coolants. A new irradiation test reactor is a costly investment that will operate for several decades and the initial specifications are crucial to ensure the relevance of such a facility in the long run. This new test reactor should be highly reconfigurable and allow operation as a fast test reactor or a thermal test reactor or a cou-pled fast-thermal test reactor. This report presents the on-going effort at Idaho National Laboratory (INL) to design a versatile coupled test reactor (VCTR—pronounced Victor) that could fulfill the R&D needs requiring high fast neutron fluxes but also high thermal neutron fluxes in configurations that could not be met in current thermal neutron test reactors such as ATR. The objective of this report is to summarize the efforts undertaken at INL from May 2015 to March 2016 aimed at understanding the main options for designing and building a versatile test reactor, with a primary mission to provide thermal and fast neutrons for irradiation of fuels and materials in a manner complementary to the ATR and HFIR reactors. Other missions can also be considered, including the validation of computer codes and the development of specific reactor technologies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Blunt Impact Brain Injury using Cellular Injury Criterion

The Advanced Combat Helmet (\ACH") military specification (\mil-spec") requires a helmeted magnesium (\Mg") Department of Transportation (\DOT") headform be dropped vertically, with an impact speed of 3.1 m/s (10 ft/s), onto a steel hemispherical target. The pass/fail criteria are based on translational acceleration (150 G) alone, absent of any rotational component. Without a rotational component, the specification's injury risk application is limited to skull fracture and peripheral hematomas (subdural, subarachnoid), since this translational acceleration injury risk assessment is based on the Wayne State Tolerance Curve (\WSTC"). To provide a more comprehensive view of injury for the entire brain, an alternative approach is needed. To meet this need, we worked with a larger group called PANTHER, a collaboration between national laboratories, industry, and academia. Collaborations specific to research and results presented here come from efforts led by Mr. Ron Szalkowski and Mr. Sushant Malave, Ms. Alice Fawzi, and Dr. Christian Franck. We have developed a prototypical injury risk criterion based on the neuronal response to abrupt changes in general motion (translation, rotation, or both). The cellular-based mild traumatic brain injury (\cbmTBI") criterion utilizes both the strain and strain rate of brain tissue to account for the stretch and rate of stretch that occurs throughout the brain as a result of blunt impact to the head. We conducted physical experiments of an ACH-fitted magnesium headform, which produced repeatable headform peak accelerations. Then, we developed a simulation of the experiment, and validated the simulation output with the experimental data. We then substituted the magnesium headform with a human headform, consisting of skin, muscle, bone, gray matter, white matter, cerebral-spinal fluid, membranes, vasculature, intravertebral discs, airway and sinus. We quantified brain injury risk using the cbmTBI criterion, using the current mil-spec test and a modified test. The modified mil-spec test used an inclined anvil target that was located posterior to the crown of the helmet in the axial plane. While the current mil-spec test produced brain deformation from head translation alone, the modified test produced brain deformation from head translation and rotation, which is closer to most real world and combat theater impacts (e.g., such as occur in tertiary blast exposure). Compared to the current mil-spec test, the modified test produced elevated strains in the human digital twin. These data, mapped to the cbmTBI criterion, suggest increased injury risk for blunt impacts that cause rotation and translation, rather than just translation alone. Moreover, these data may lead to a rotational performance metric, which is rooted in the biology and pathology of the brain's response to impact and blast, and which should be used to improve next-generation helmet designs.

42 ENGINEERING↗

CO 2 Mineralization Using Porous Carbon and Industrial Wastes to Make Multifunctional Concrete

Along with substantial benefits and promises of carbon capture and storage (CCS) technologies, significant challenges exist in developing scalable materials and methods for capture and of CO 2 . The overarching objective of this project is to provide a system approach for developing a new CO 2 capture and utilization technology using porous carbon and industrial wastes to make a low-cost, scalable and multifunctional concrete product. The objective of Phase I of this project is to develop and fine-tune activated carbons from different wastes such as plastic wastes to offer a cheap, abundant and scalable feedstock for CO 2 uptake. The objective of Phase 2 is creating a facile protocol to develop a concrete prototype comprising CO 2 adsorbed activated carbon (e.g. from plastic wastes), followed by product validation, life-cycle analysis, and bench-scale testing. The project objectives are designed to specifically obtain a final product and technology that directly addresses the main goals of the DOE’s CCS programs.

01 COAL, LIGNITE, AND PEAT↗

Impact Report: Quantum Systems Accelerator

The Quantum Systems Accelerator (QSA) is a U.S. National Quantum Information Science Research Center established in August 2020 and funded by the Department of Energy (DOE) Office of Science. QSA is composed of 15 partner institutions— universities and national laboratories—bringing together pioneers of many of today’s unique quantum information science (QIS) and engineering capabilities. Led by Lawrence Berkeley National Laboratory (Berkeley Lab), with Sandia National Laboratories (Sandia Labs) as the lead partner, 250+ QSA researchers are catalyzing U.S. leadership in a fast-growing field that seeks solutions to the Nation’s and the world’s most pressing problems by harnessing the laws of quantum mechanics.

97 MATHEMATICS AND COMPUTING↗

HIGHLY-EFFICIENT 20-MW L-BAND MULTI-BEAM KLYSTRON

The overall goal of this project was to develop and demonstrate a novel two-stage multi-beam klystron (TS-MBK) for use in accelerator, medical, national security, medical, and environmental cleanup applications. The novelties embodied in the TS-MBK design include use of hollow beams to obtain strong coupling to cavities, and post acceleration after bunching to reduce the beam’s energy spread to allow an exceptional electronic efficiency that we predict can reach 90%. During Phase I of this project, Omega-P R&D refined its conceptual design of the 1.0 GHz TS-MBK, and collector design and cooling requirements for several levels of average power output. If, as was the case, it turned out that estimated costs for fabrication and testing of a full 12-beam TS-MBK prototype would exceed available Phase II funding, our Plan-B would have be adopted. In it, a single-beam version would have been designed and built, with all specifications identical to the 12-beam version, except that the average power level would be reduced by a factor of about 12. This one-beam version would still allow evaluation of the efficacy of our design concept for implementing two stages, including prevention of radiation loss at the HV gap, and for demonstrating the predicted 90% electronic efficiency and the absence of reflected electrons from the collector reaching the cathodes. But the absence of the expected industrial partner in further development of this novel RF source made it impractical for advancing the project into Phase II.

43 PARTICLE ACCELERATORS↗

Communication: Dominance of extreme statistics in a prototype many-body Brownian ratchet

Many forms of cell motility rely on Brownian ratchet mechanisms that involve multiple stochastic processes. We present a computational and theoretical study of the nonequilibrium statistical dynamics of such a many-body ratchet, in the specific form of a growing polymer gel that pushes a diffusing obstacle. We find that oft-neglected correlations among constituent filaments impact steady-state kinetics and significantly deplete the gel's density within molecular distances of its leading edge. These behaviors are captured quantitatively by a self-consistent theory for extreme fluctuations in filaments' spatial distribution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An experimental study on dehumidification and regeneration performance of a new nonporous membrane-based heat and mass exchanger using an ionic liquid desiccant

As a promising alternative to inefficient vapor-compression-based air conditioning, liquid desiccant dehumidification uses a liquid desiccant in contact with the humid air absorbing the moisture. However, it has not gained much market share due to the issues related to the carryover, corrosion, fouling, and crystallization of liquid desiccant. The research has developed a new membrane-based exchanger, which uses a non-corrosive ionic liquid desiccant and nonporous tubular membranes to address these issues. As the second generation of the prototype, the new exchanger was tested at various operating conditions. According to the experimental data, when it is used in the dehumidification loop, the new membrane-based exchanger achieves a specific vapor transportation rate of 778.6 g/(h–m 2 ) and an average water vapor flux of 0.316 g/(h-m 2 -Pa), which is a significant improvement compared with the previous designs using nonporous membranes. It also achieved a comparable or even better dehumidification performance compared with the dehumidifiers that use porous membrane and conventional liquid desiccants. However, the regeneration performance is not as good as its dehumidification. It is mainly caused by the high operating temperature required in the regeneration loop. The experimental data and findings provide first-hand experimental data and enhance the understanding of advanced membrane-based ionic liquid desiccant systems.

42 ENGINEERING↗

Information barrier experimental: Toward a trusted and open-source computing platform for nuclear warhead verification

Trusted measurement systems are critical for the verification of future arms-control treaties that involve confirming the authenticity of nuclear warheads on the basis of their radiation signatures. Several research efforts have produced prototype systems, but their designs are typically not published in detail, making it difficult to enable trust in these devices. The Information Barrier Experimental (IBX) is a new prototype built around the Red Pitaya computing platform using passive gamma spectroscopy. It is the first such platform designed to help a broad research community study vulnerabilities and define the required specifications for a common, trusted inspection system. It is low-cost, simple to assemble, and enables comprehensive hardware and software authentication studies. The device follows a digital data acquisition approach, which significantly reduces the number of components between scintillator and spectrum output. Finally, measurements demonstrate that this approach is technically feasible and produces excellent measurement results.

97 MATHEMATICS AND COMPUTING↗

Oxygen-Based Anion Redox for Lithium Batteries

The importance of current Li-ion batteries (LIBs) in modern society cannot be overstated. While the energy demands of devices increase, the corresponding enhancements in energy density of battery technologies are highly sought after. Currently, many different battery concepts, such as Li-S and metal-air among many others, have been investigated. However, their practical implementation has mostly been restricted to the prototyping stage. In fact, most of these technologies require rework of existing Li-ion battery manufacturing facilities and will naturally incur resistance to change from industry. For this reason, one specifically attractive technology, anionic redox in transition metal oxides, has gained much attention in the recent years. Its ability to be directly used in already established processes and higher energy density with similar electrolyte formulation make it a key materials research direction for next generation Li-ion batteries. In regular LIBs, the redox active centers are the transition metal cation. In anion redox, both the anion (typically O) and the transition metal cation are utilized as redox centers with enormous implications for increasing energy density. This new material can be highly competitive for replacing the current LIB technologies. However, much is still unknown about its cyding mechanism. Upon activating the O redox couples, most cationic and anionic redox active materials will either evolve O 2 or undergo irreversible structural degradation with associated severe decreases in electrochemical performance. By understanding the transition from full anion redox to partial cationic and anionic redo; we hope readers can gain a deeper understanding of the topic. This Account will focus mainly on the work that was conducted by our group at Argonne National Laboratory. Herein, the phenomenon of cationic and anionic redox in a lithium-ion battery cathode will first be discussed. Our work in resonant inelastic X-ray scattering to investigate the spectroscopic features of O after delithiation has found potential "fingerprint" signals that could likely be used to identify and confirm reversible O redox if corroborated with other techniques. To follow, we will examine our work on Li-O 2 batteries. While our group and the research community have had many significant contributions and improvements to the field of Li-O 2 (such as decreasing overpotential and achieving cyclability in air environment), its practical application is still far from realization. Perhaps our most important contribution to this area is the discovery that Ir deposited on reduced graphene oxide can be used to halt the reduction of O 2 at the LiO 2 oxidation state. This not only significantly decreases the charge overpotential but also presents the important concept of oxidation-state controlled discharge. Subsequently, we will focus on our oxidation state-controlled redox-based charging of oxygen in a pure oxygen redox Li-ion battery. Future implications of this technology will be emphasized.

25 ENERGY STORAGE↗

SU-E-T-571: Newly Emerging Integrated Transmission Detector Systems Provide Online Quality Assurance of External Beam Radiation Therapy

Purpose: Two newly emerging transmission detectors positioned upstream from the patient have been evaluated for online quality assurance of external beam radiotherapy. The prototype for the Integral Quality Monitor (IQM), developed by iRT Systems GmbH (Koblenz, Germany) is a large-area ion chamber mounted on the linac accessory tray to monitor photon fluence, energy, beam shape, and gantry position during treatment. The ion chamber utilizes a thickness gradient which records variable response dependent on beam position. The prototype of Delta4 Discover™, developed by ScandiDos (Uppsala, Sweden) is a linac accessory tray mounted 4040 diode array that measures photon fluence during patient treatment. Both systems are employable for patient specific QA prior to treatment delivery. Methods: Our institution evaluated the reproducibility of measurements using various beam types, including VMAT treatment plans with both the IQM ion chamber and the Delta4 Discover diode array. Additionally, the IQM’s effect on photon fluence, dose response, simulated beam error detection, and the accuracy of the integrated barometer, thermometer, and inclinometer were characterized. The evaluated photon beam errors are based on the annual tolerances specified in AAPM TG-142. Results: Repeated VMAT treatments were measured with 0.16% reproducibility by the IQM and 0.55% reproducibility by the Delta4 Discover. The IQM attenuated 6, 10, and 15 MV photon beams by 5.43±0.02%, 4.60±0.02%, and 4.21±0.03% respectively. Photon beam profiles were affected <1.5% in the non-penumbra regions. The IQM’s ion chamber’s dose response was linear and the thermometer, barometer, and inclinometer agreed with other calibrated devices. The device detected variations in monitor units delivered (1%), field position (3mm), single MLC leaf positions (13mm), and photon energy. Conclusion: We have characterized two new transmissions detector systems designed to provide in-vivo like measurements upstream from the patient. Both systems demonstrate substantial utility for online treatment verification and QA of photon external beam radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗