Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Low temperature magnetic structure of CeRhIn 5 by neutron diffraction on absorption-optimized samples

Here, two aspects of the ambient pressure magnetic structure of heavy fermion material CeRhIn 5 have remained under some debate since its discovery: whether the structure is indeed an incommensurate helix or a spin density wave, and what is the precise magnitude of the ordered magnetic moment. By using a single crystal sample optimized for hot neutrons to minimize neutron absorption by Rh and In, here we report an ordered moment of $m=0.54(2)\,{{\mu}_{\text{B}}}$. In addition, by using spherical neutron polarimetry measurements on a similar single crystal sample, we have confirmed the helical nature of the magnetic structure, and identified a single chiral domain.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improvements in the Sample Space for the Backscattering Silicon Spectrometer (BASIS)

The increase in neutron flux at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS), currently operating at 2.0 MW proton beam power, has created new opportunities for higher-throughput neutron scattering experiments while also increasing the importance of minimizing background scattering and optimizing sample-environment operations. To address these challenges on the Backscattering Silicon Spectrometer (BA-SIS), several upgrades were developed and evaluated, including boron carbide (B₄C) masking for flat-plate sample containers, multi-cell sample holders used with a vertically translating sample stick, and an automated helium pump and purge (HPP) system for closed-cycle refrigerators. Neutron diffraction measurements demonstrate that B₄C masks reduce background scattering by 49–67%, outperforming both borated aluminum and boron nitride masks while introducing no additional Bragg reflections within the instrument’s accessible Q-range. Commissioning tests of a double-cell flat-plate sample contain-er showed no measurable crosstalk between adjacent sample compartments and con-firmed stable thermal performance, enabling multiple samples to be measured without re-peated temperature cycling. In addition, the automated HPP system provided reproducible sample-space gas handling with approximately ±1 mbar precision while reducing the need for operator intervention and supporting remote operation. Together, these developments improve signal-to-noise performance, increase experimental throughput, and enhance operational efficiency at BASIS, supporting the instrument’s continued operation under higher neutron flux conditions.

Jalarvo, Niina [ORNL] (ORCID:0000000306446866)↗

Simulation Study of High-Precision Characterization of MeV Electron Interactions for Advanced Nano-Imaging of Thick Biological Samples and Microchips

The resolution of a mega-electron-volt scanning transmission electron microscope (MeV-STEM) is primarily governed by the properties of the incident electron beam and angular broadening effects that occur within thick biological samples and microchips. A precise understanding and mitigation of these constraints require detailed knowledge of beam emittance, aberrations in the STEM column optics, and energy-dependent elastic and inelastic critical angles of the materials being examined. This simulation study proposes a standardized experimental framework for comprehensively assessing beam intensity, divergence, and size at the sample exit. This framework aims to characterize electron-sample interactions, reconcile discrepancies among analytical models, and validate Monte Carlo (MC) simulations for enhanced predictive accuracy. Our numerical findings demonstrate that precise measurements of these parameters, especially angular broadening, are not only feasible but also essential for optimizing imaging resolution in thick biological samples and microchips. By utilizing an electron source with minimal emittance and tailored beam characteristics, along with amorphous ice and silicon samples as biological proxies and microchip materials, this research seeks to optimize electron beam energy by focusing on parameters to improve the resolution in MeV-STEM/TEM. This optimization is particularly crucial for in situ imaging of thick biological samples and for examining microchip defects with nanometer resolutions. Our ultimate goal is to develop a comprehensive mapping of the minimum electron energy required to achieve a nanoscale resolution, taking into account variations in sample thickness, composition, and imaging mode.

36 MATERIALS SCIENCE↗

Analysis of lunar samples for carbon compounds.

Description of one approach to the analysis for carbon compounds in lunar materials from the Apollo 11 mission. The sequential scheme followed generally accepted organic geochemical practices, but was unusual in its application to a single sample. The procedures of the scheme were designed to minimize handling of the solids and extracts or hydrolysates. The solid lunar sample was retained in all steps of the sequential analysis in the vessel in which it was originally placed. Centrifugation was used to separate solid and liquid phases after extraction or refluxing. Liquids were recovered from solids by decantation.

Kvenvolden, K. A.↗

SU-F-T-550: Radiochromic Plastic Thin Sheet Dosimeter: Initial Performance

Purpose: Thin sheets, of a high sensitivity formulation of radiochromic dosimeter, Presage were prepared and evaluated for optical readout. Methods: Sheets of radiochromic polyurethane, 12 cm long, 10 cm wide and 0.2 cm thick were prepared with leuco crystal violet as the reporter molecule. Sample transmission was evaluated at a wavelength of 590 nm with in-house constructed instruments: optical cone beam laser CT scanner, fixed and scanning spot densitometers. Sample sequential irradiations to a total dose of 40 Gy were conducted with a modified, Theratron 60, cobalt radiotherapy machine at dose rates of 1 or 0.25 Gy per minute. Exposure to ambient and readout light was minimized to limit background photochromic signals. Samples were stored at 4°C. Optical activity was assessed from linearly polarized transmission images. Comparison sensitivity measurements with EBT3 film were conducted. Results: Samples were transparent, smooth and pale purple before irradiation. Radiochromic reaction was completed in less than 5 minutes. A linear dose response with a sensitivity of 0.5 cm-1Gy-1 was observed. Micrometer measurements found sheet thickness variations up to 20%. Uniform dose, 2 Gy attenuation images, correlated with local sheet thicknesses. Comparable measurements with EBT3 film were 3 times more sensitive at 1 Gy but above 15 Gy, EBT3 film had lower sensitivity than 0.2 cm thick Presage sheet dosimeter due to its non-linear response. Conclusion: Dose sensitivity provided a 10% decrease in transmission for a 1 Gy dose. Improvements in mold design are expected to allow production of sheets with less than 5% variation in thickness. Above, 10 Gy, Presage sheet dosimeter performance expected to exceed EBT3 film based on linearity, sensitivity, transparency and smoothness of samples. J Adamovics is owner of Heuris Inc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mining the human urine proteome for monitoring renal transplant injury

The human urinary proteome reflects systemic and inherent renal injury perturbations and can be analyzed to harness specific biomarkers for different kidney transplant injury states. 396 unique urine samples were collected contemporaneously with an allograft biopsy from 396 unique kidney transplant recipients. Centralized, blinded histology on the graft was used to classify matched urine samples into categories of acute rejection (AR), chronic allograft nephropathy (CAN), BK virus nephritis (BKVN), and stable graft (STA). Liquid chromatography–mass spectrometry (LC-MS) based proteomics using iTRAQ based discovery (n=108) and global label-free LC-MS analyses of individual samples (n=137) for quantitative proteome assessment were used in the discovery step. Selected reaction monitoring (SRM) was applied to identify and validate minimal urine protein/peptide biomarkers to accurately segregate organ injury causation and pathology on unique urine samples (n=151). A total of 958 proteins were initially quantified by iTRAQ, 87% of which were also identified among 1574 urine proteins detected in LC-MS validation. 103 urine proteins were significantly (p<0.05) perturbed in injury and enriched for humoral immunity, complement activation, and lymphocyte trafficking. A set of 131 peptides corresponding to 78 proteins were assessed by SRM for their significance in an independent sample cohort. A minimal set of 35 peptides mapping to 33 proteins, were modeled to segregate different injury groups (AUC =93% for AR, 99% for CAN, 83% for BKVN). Urinary proteome discovery and targeted validation identified urine protein fingerprints for non-invasive differentiation of kidney transplant injuries, thus opening the door for personalized immune risk assessment and therapy.

Environmental Molecular Sciences Laboratory↗

Determining pseudoscalar meson photoproduction amplitudes from complete experiments

In preparation for a new generation of complete experiments with the goal of performing a high precision extraction of pseudoscalar meson photo-production amplitudes, we present expressions that allow the direct numerical calculation of matrix elements with arbitrary spin projections from Chew-Goldberger-Low-Nambu (CGLN) amplitudes. We use this numerical tool to verify the most general analytic form of the cross section, dependent upon the three polarization vectors of the beam, target and recoil baryon, including all single, double and triple-polarization terms involving 16 spin-dependent observables. Analytic expressions that determine the recoil baryon polarization are presented, together with examples of their potential use with quasi-4? detectors to deduce observables. We assemble the analytic equations relating the 16 experimental observables and the CGLN amplitudes and use our independent method of numerical evaluation to resolve sign differences that exist in the literature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Changing the Rules of the Game: Used Fuel Studies Outside of a Remote Handling Facility

Recent advances in micro-fabrication tools like the FEI Helios NanoLab 660 dual Focused Ion Beam (FIB) and Scanning Electron Microscope (SEM) now make it possible to easily and reliably prepare micron (or smaller) specimens for analyses or further experimentation. Pacific Northwest National Laboratory (PNNL) has leveraged this capability at the Category II Nuclear Facility, the Radiochemical Processing Laboratory, to facilitate nuclear materials analysis and experimentation of used nuclear fuel. Micron-scale specimens of un-irradiated UO2 fuel pellets of various enrichments from depleted to 4.95% enriched, relative to 235U, were prepared at PNNL and shipped to the University of Missouri’s Research Reactor (MURR) for irradiation. Prior to shipping, samples were attached to commercially available Transmission Electron Microscopy half-grids via ion deposition, which were then housed in specially designed aluminum sample holders approved for use at the reactor facility. This minimized handling and preparation requirements prior to materials analysis after irradiation. Samples were irradiated to a burnup equivalent of 8 – 3,700 MWd/MTU. Additionally, by reducing the size of the specimens, and therefore their emitted radiation dose, the required cooling time after irradiation and prior to analysis was greatly diminished, and handling of these samples could proceed outside of a hot cell facility. Results from these experiments provided insight into the initial production of noble metal phase particles in used nuclear fuel at extremely low burnup levels. Some incompatibility with the container was observed at higher burnup. Micro-scale irradiation experiments were performed at roughly 1/7th of the time, effort and expense a similar bulk-scale study requiring a shielded hot cell facility would require. Conducting nuclear materials analysis at the micron-scale holds the promise of enhancing collaboration and material accessibility to the broader research community, improving accessibility to cutting edge research tools by the nuclear materials science community, lowering the risk to the scientist by reducing radiation dose and exposure, reducing facility and research costs associated with the requirement to conduct nuclear materials science within glovebox or remote handling facilities, and minimizing waste.

Schwantes, Jon M.↗

Nanoscale biochemical sample preparation and analysis

Provided herein are methods and systems for biochemical analysis, including compositions and methods for processing and analysis of small cell populations and biological samples (e.g., a robotically controlled chip-based nanodroplet platform). In particular aspects, the methods described herein can reduce total processing volumes from conventional volumes to nanoliter volumes within a single reactor vessel (e.g., within a single droplet reactor) while minimizing losses, such as due to sample evaporation.

Kelly, Ryan T.↗

Environmental associations of Ophidiomyces ophidiicola , the causative agent of ophidiomycosis in snakes

Emerging pathogenic fungi have become a topic of conservation concern due to declines observed in several host taxa. One emerging fungal pathogen, Ophidiomyces ophidiicola, is well documented as the causative agent of ophidiomycosis, otherwise known as snake fungal disease (SFD). O. ophidiicola has been found to cause disease in a variety of snake species across the United States, including the eastern massasauga (Sistrurus catenatus), a federally threatened rattlesnake species. Most work to date has involved detecting O. ophidiicola for diagnosis of infection through direct sampling of snakes, and attempts to detect O. ophidiicola in the abiotic environment to better understand its distribution, seasonality, and habitat associations are lacking. We collected topsoil and groundwater samples from four macrohabitat types across multiple seasons in northern Michigan at a site where Ophidiomyces infection has been confirmed in eastern massasauga. Using a quantitative PCR (qPCR) assay developed for O. ophidiicola, we detected Ophidiomyces DNA in topsoil but observed minimal to no detection in groundwater samples. Detection frequency did not differ between habitats, but samples grouped seasonally showed higher detection during mid-summer. We found no relationships of detection with hypothesized environmental correlates such as soil pH, temperature, or moisture content. Furthermore, the distribution of Ophidiomyces positive samples across the site was not linked to estimated space use of massasaugas. Our data suggests that season has some effect on the presence of Ophidiomyces. Differences in presence between habitats may exist but are likely more dependent on the time of sampling and currently uninvestigated soil or biotic parameters. These findings build on our understanding of Ophidiomyces ecology and epidemiology to help inform where and when snakes may be exposed to the fungus in the environment.

59 BASIC BIOLOGICAL SCIENCES↗

The Role of Water in the Storage of Hydrogen in Metals

One major problem with the use of hydrogen is safe and efficient storage. In the pure form, bulky and heavy containers are required greatly reducing the efficiency of its use. Safety is also a great concern. Storage of hydrogen in the form of a metal hydride offers distinct advantages both in terms of volumetric efficiency and in terms of safety. As a result, an enormous amount of research is currently being done on metal-hydrogen systems. Practical application of these systems to storage of hydrogen can only occur when they are very well understood. In this paper, the preliminary results of a study of the surfaces of magnesium nickel alloys will be presented. Alloys that have been rendered totally unreactive with hydrogen as well as those that have been activated with liquid water and with water vapor were studied. Data obtained from XPS (X-ray Photoelectron Spectrometer) analysis, with samples held in vacuum for the shortest possible time to minimize the hydroxide degradation will be presented. Furthermore, TEM data on samples prepared in a new way that largely protects the surface from the high vacuum will be discussed.

Hampton, Michael D.↗

Passive Thermal Coating Observatory Operating in Low-Earth Orbit (PATCOOL) – Cubesat Design to Test Passive Thermal Coatings in Space

The PATCOOL is a NASA sponsored, University of Florida developed 3U Cu-beSat meant to investigate the feasibility of using a cryogenic selective surface coating as a new, more efficient way of passively cooling components in space. Initial tests on the ground demonstrate that this coating should provide a much higher reflectance of the Sun’s irradiant power than any existing coating, while still providing far-infrared power emission. The ultimate validation of this tech-nology requires on-orbit testing. PATCOOL hosts a 4-sample housing, with the samples shaped as thin cylinders (coin-like). Two samples are coated with state-of-the-art material, while the other pair uses the new coating to be evaluated. The temperatures of all samples during the mission (minimum 72 hours of data col-lection) are measured via thermistors. The samples are connected via thin Kevlar strings to the housing, to minimize heat transfer. The housing is designed to shield the samples from Earth’s thermal radiation, and the CubeSat is attitude stabilized and controlled via a gravity gradient boom, magnetorquers and a reaction wheel set. Thermal Desktop simulations show PATCOOL’s ability to thermally isolate the samples from heat exchanges other than with Sun and deep space, thanks to its thermal design and the chosen attitude profile.

Ojeda, Carlos↗

PAssive Thermal Coating Observatory Operating in Low Earth Orbit (PATCOOL)

The PATCOOL is a NASA sponsored, University of Florida developed 3U CubeSat meant to investigate the feasibility of using a cryogenic selective surface coating as a new, more efficient way of passively cooling components in space. Initial tests on the ground demonstrate that this coating should provide a much higher reflectance of the Sun's irradiant power than any existing coating, while still providing far-infrared power emission. The ultimate validation of this technology requires on-orbit testing. PATCOOL hosts a 4-sample housing, with the samples shaped as thin cylinders (coin-like). Two samples are coated with state-of-the-art material, while the other pair uses the new coating to be evaluated. The temperatures of all samples during the mission (minimum 72 hours of data collection) are measured via thermistors. The samples are connected via thin Kevlar strings to the housing, to minimize heat transfer. The housing is designed to shield the samples from Earth's thermal radiation, and the CubeSat is attitude stabilized and controlled via a gravity gradient boom, magnetorquers and a reaction wheel set. Thermal Desktop simulations show PATCOOL's ability to thermally isolate the samples from heat exchanges other than with Sun and deep space, thanks to its thermal design and the chosen attitude profile

Ojeda, Carlos↗

Atacama Rover Astrobiology Drilling Studies Project: Final Year

The Atacama Rover Astrobiology Drilling Studies (ARADS) project, a simulated Mars rover biomarker detection mission, was iteratively developed over four years from 2015 -2019, including three NASA centers, the Centro de Astrobiologia, Johns Hopkins University, Honeybee Robotics, Maxar and the University of Antofagasta. The final (4th) ARADS field season, in 2019, tested an integrated mobile life-prospecting platform loosely inspired by the 2000’s Astrobiology Field Laboratory concept, with a 1m rotary-percussive drill and sample transfer robot arm that fed three astrobiology instruments operating in-situ on the KREX2 medium rover prototype. A fourth instrument was field tested earlier in 2019 due to flight mission requirements. In the final ARADS field deployment in September 2019, the project conducted a remote mission operation simulation (Stoker 2022)demonstrating sample drilling, acquisition and transfer into the rover instruments (while minimizing cross-contamination), performing in-situ analysis of the samples, and returning the results to a remote science operations team(which commanded the daily science goals and uploaded operations sequences).

astrobiology↗

Carbon XANES Data from Six Aerogel Picokeystones Cut from the Top and Bottom Sides of the Stardust Comet Sample Tray

Great care and a large effort was made to minimize the amount of organic matter contained within the flight aerogel used to collect Comet 81P/Wild 2 samples. Even so, by the very nature of the production process and silica aerogel s affinity for volatile organics keeping silica aerogel free from organics is a monumental task. Silica aerogel from three production batches was flown on the Stardust sample return mission. All 3 types had layered densities varying from 5mg/ml to 50 mg/ml where the densest aerogel was farthest away from the collection area. A 2 step gelation process was used to make the flight aerogel and organics used in this process were tetraethylorthosilicate, ethanol and acetonitrile. Both ammonium hydroxide and nitric acid were also used in the aerogel production process. The flight aerogel was baked at JPL at 300 C for 72 hours, most of the baking was done at atmosphere but twice a day the oven was pumped to 10 torr for hour [1]. After the aerogel was baked it was stored in a nitrogen purged cabinet until flight time. One aerogel cell was located in the SRC away from any sample collection area as a witness to possible contamination from out gassing of the space craft, re-entry gases and any other organic encounter. This aerogel was aerogel used in the interstellar collection sample tray and is the least dense of the 3 batches of aerogel flown. Organics found in the witness tile include organics containing Si-CH3 bonds, amines and PAHS. Besides organic contamination, hot spots of calcium were reported in the flight aerogel. Carbonates have been detected in comet 81P/Wild2 samples . During preflight analyses, no technique was used to analyze for carbonates in aerogel. To determine if the carbonates found in 81P/Wild2 samples were from the comet, it is necessary to analyze the flight aerogel for carbonate as well as for organics.

Wirick, S.↗

Plug-and-play polymer microfluidic chips for hydrated, room temperature, fixed-target serial crystallography

The practice of serial X-ray crystallography (SX) depends on efficient, continuous delivery of hydrated protein crystals while minimizing background scattering. Of the two major types of sample delivery devices, fixed-target devices offer several advantages over widely adopted jet injectors, including: lower sample consumption, clog-free delivery, and the ability to control on-chip crystal density to improve hit rates. In this study we present our development of versatile, inexpensive, and robust polymer microfluidic chips for routine and reliable room temperature serial measurements at both synchrotrons and X-ray free electron lasers (XFELs). Our design includes highly X-ray-transparent enclosing thin film layers tuned to minimize scatter background, adaptable sample flow layers tuned to match crystal size, and a large sample area compatible with both raster scanning and rotation based serial data collection. The optically transparent chips can be used both for in situ protein crystallization (to eliminate crystal handling) or crystal slurry loading, with prepared samples stable for weeks in a humidified environment and for several hours in ambient conditions. Serial oscillation crystallography, using a multi-crystal rotational data collection approach, at a microfocus synchrotron beamline (SSRL, beamline 12-1) was used to benchmark the performance of the chips. Furthermore, high-resolution structures (1.3–2.7 Å) were collected from five different proteins – hen egg white lysozyme, thaumatin, bovine liver catalase, concanavalin-A (type VI), and SARS-CoV-2 nonstructural protein NSP5. Overall, our modular fabrication approach enables precise control over the cross-section of materials in the X-ray beam path and facilitates chip adaption to different sample and beamline requirements for user-friendly, straightforward diffraction measurements at room temperature.

59 BASIC BIOLOGICAL SCIENCES↗

Digital Filter Separates Signal From Noise

Variance of signal-estimation error minimized. Mathematical technique extracts best estimates of signal component from periodic digital samples of signal plus noise. Technique combines Kalman- and smoothingfilter algorithms to minimize mean-square estimation error based on past, present, and predicted samples of signal plus noise. Technique useful in image analysis and other applications involving processing of noisy signals.

Lear, W. M.↗

Design and operation of the wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source

The wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source (SNS) is optimized to provide a high neutron flux at the sample position with a large solid angle of detector coverage. The instrument incorporates modern neutron instrumentation, such as an elliptically focused neutron guide, high speed magnetic bearing choppers, and a massive array of {sup 3}He linear position sensitive detectors. Novel features of the spectrometer include the use of a large gate valve between the sample and detector vacuum chambers and the placement of the detectors within the vacuum, both of which provide a window-free final flight path to minimize background scattering while allowing rapid changing of the sample and sample environment equipment. ARCS views the SNS decoupled ambient temperature water moderator, using neutrons with incident energy typically in the range from 15 to 1500 meV. This range, coupled with the large detector coverage, allows a wide variety of studies of excitations in condensed matter, such as lattice dynamics and magnetism, in both powder and single-crystal samples. Comparisons of early results to both analytical and Monte Carlo simulation of the instrument performance demonstrate that the instrument is operating as expected and its neutronic performance is understood. ARCS is currently in the SNS user program and continues to improve its scientific productivity by incorporating new instrumentation to increase the range of science covered and improve its effectiveness in data collection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗