Search NASA⌕ Search

SEARCH · Search NASA

Results for “samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Agricultural Ice Nuclei at Southern Great Plains Supplemental Sampling (AGINSGP-SUPP) Field Campaign Report

The Agricultural Ice Nuclei at Southern Great Plains Supplemental Sampling (AGINSGP-SUPP) field campaign took place from April 8 to April 28, 2022. It included sample collection and analysis of filter samples for ice-nucleating particle (INP) concentrations. By enabling quantification of INPs at warmer temperatures (i.e., T > 258 K), these samples complemented the real-time observations of INPs that were performed as part of the AGINSGP campaign during the same period. In addition to collecting ground-based samples, the campaign collected vertical samples of INPs aboard the Atmospheric Radiation Measurement (ARM) tethered balloon system (TBS) as shown in Figure 1. These vertical samples complemented the vertical profiling of aerosol properties that was supported under a related Facilities Integrating Collaborations for User Science (FICUS) proposal. The overall aim of these three campaigns was to improve understanding of the sources and variability in observed INP concentrations at ARM’s SGP observatory. For example, warm-temperature INPs in this agricultural region are thought to originate in part from regional emissions of fertile, agricultural soils containing high organic content. Laboratory experiments have shown that soil particles with high organic content are more efficient INPs than inorganic soils (e.g., Tobo et al. 2014). Quantification of warm-temperature INPs under ambient conditions currently can only be achieved via offline methods such as the ARM ice-nucleation spectrometer (INS). Therefore, offline sampling for the INS was required to complement the real-time INP measurements conducted during the AGINSGP campaign.

, tethered balloon system↗

Improvements in the Sample Space for the Backscattering Silicon Spectrometer (BASIS)

The increase in neutron flux at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS), currently operating at 2.0 MW proton beam power, has created new opportunities for higher-throughput neutron scattering experiments while also increasing the importance of minimizing background scattering and optimizing sample-environment operations. To address these challenges on the Backscattering Silicon Spectrometer (BA-SIS), several upgrades were developed and evaluated, including boron carbide (B₄C) masking for flat-plate sample containers, multi-cell sample holders used with a vertically translating sample stick, and an automated helium pump and purge (HPP) system for closed-cycle refrigerators. Neutron diffraction measurements demonstrate that B₄C masks reduce background scattering by 49–67%, outperforming both borated aluminum and boron nitride masks while introducing no additional Bragg reflections within the instrument’s accessible Q-range. Commissioning tests of a double-cell flat-plate sample contain-er showed no measurable crosstalk between adjacent sample compartments and con-firmed stable thermal performance, enabling multiple samples to be measured without re-peated temperature cycling. In addition, the automated HPP system provided reproducible sample-space gas handling with approximately ±1 mbar precision while reducing the need for operator intervention and supporting remote operation. Together, these developments improve signal-to-noise performance, increase experimental throughput, and enhance operational efficiency at BASIS, supporting the instrument’s continued operation under higher neutron flux conditions.

Jalarvo, Niina [ORNL] (ORCID:0000000306446866)↗

Computational Fluid Dynamics Modeling to Facilitate Qualification of Stack Sampling Probe Location

Computational fluid dynamics (CFD) modeling was used to help evaluate modifications to a radiological effluent stack and assist with establishing a stack sampling location that met the mixing criteria for qualification. Requirements for stack sampling location are listed in the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-2021 standard. Modeling was performed to help develop a suitable design for increasing building ventilation for the radiological effluent stack. The ANSI/HPS N13.1-2021 criteria for the air monitoring probe location are that the coefficient of variation of velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20 degrees. The ANSI/HPS N13.1-2021 standard allows for models (physical or computational) to be employed to perform the full suite of qualification tests, followed by a more limited set of verification tests on the actual stack to qualify the stack sampling location. Here, a series of computational model simulations were employed to evaluate the stack qualification criteria. Significant time and re-source savings are achieved using CFD modeling. CFD modeling demonstrated that the stack meets the criteria at the sample probe location. Verification tests were performed on the modified stack to measure the velocity uniformity and flow angle at the stack sampling location, and results demonstrated that the CFD model results may be used to support the qualification of the stack sampling location.

Air Monitoring↗

Preliminary examination of lunar samples

The morphology, mineralogy, petrology, and chemistry of the samples returned from the Apollo 15 landing site are discussed. A selenological description of the area from which the samples were taken is given. The diversity of the samples and the variety of sample environments found at the Apollo 15 site have resulted in several hypotheses that relate individual samples to local situations after even a preliminary examination of the samples. Several somewhat speculative hypotheses that relate individual samples to a geological framework are discussed in the hope that the hypotheses will provide guidelines for more detailed studies of the samples to arrive at an integrated understanding of the selenology of the Apollo 15 site.

Source record↗

Test evaluation of potential heat shield contamination of an Outer Planet Probe's atmospheric sampling system

An Outer Planets Probe which retains the charred heatshield during atmospheric descent must deploy a sampling tube through the heatshield to extract atmospheric samples for analysis. Once the sampling tube is deployed, the atmospheric samples ingested must be free of contaminant gases generated by the heatshield. Outgassing products such as methane and water vapor are present in planetary atmospheres and hence, ingestion of such species would result in gas analyzer measurement uncertainties. This paper evaluates the potential for, and design impact of, the extracted atmospheric samples being contaminated by heatshield outgassing products. Flight trajectory data for Jupiter, Saturn and Uranus entries are analyzed to define the conditions resulting in the greatest potential for outgassing products being ingested into the probe's sampling system. An experimental program is defined and described which simulates the key flow field features for a planetary flight in a ground-based test facility. The primary parameters varied in the test include: sampling tube length, injectant mass flow rate and angle of attack. Measured contaminant levels predict the critical sampling tube length for contamination avoidance. Thus, the study demonstrates the compatibility of a retained heatshield concept and high quality atmospheric trace species measurements.

Kessler, W. C.↗

Fluid sample collection and distribution system

A multipoint fluid sample collection and distribution system is provided wherein the sample inputs are made through one or more of a number of sampling valves to a progressive cavity pump which is not susceptible to damage by large unfiltered particles. The pump output is through a filter unit that can provide a filtered multipoint sample. An unfiltered multipoint sample is also provided. An effluent sample can be taken and applied to a second progressive cavity pump for pumping to a filter unit that can provide one or more filtered effluent samples. The second pump can also provide an unfiltered effluent sample. Means are provided to periodically back flush each filter unit without shutting off the whole system.

Brooks, R. L.↗

Sampling Landsat classifications for crop area estimation

An investigation was conducted to evaluate the effect of several sampling alternatives on the accuracy of crop area estimates made from classification of Landsat Multispectral Scanner (MSS) data. The specific objective was to assess the precision and the bias associated with alternative sampling schemes involving different numbers of several sampling unit sizes. The estimates achieved using the 5 by 6 nm segments were found to have the least precision of any sampling scheme tested. The estimates become more precise as the segment size decreases and more segments are taken. The precision of the 5 by 6 nm segments was significantly less than that of the pixel samples. None of the sampling schemes was significantly biased on the average, and none of the average estimates differed significantly from the population parameter. The maximum absolute deviation, however, was directly related to sampling unit size and should be considered in selection of a sampling unit.

Hixson, M. M.↗

Comet coma sample return via Giotto II

A comet coma sample return is possible with a low-cost flyby mission. Collecting coma materials and returning them to earth can be accomplished in a free-return trajectory. Intact capture of coma dust, preserving the cometary dust mineralogy, is possible at low encounter speeds. Samples from a known cometary source can then be compared with the wealth of information on meteorites and interplanetary dust. Sample return via Giotto II is a unique, low-cost NASA/ESA cooperative opportunity. With ESA providing the Giotto spacecraft and payload and NASA the sample return capability, first-class science can be accomplished at a very low cost for both NASA and ESA. This paper focuses on the sample return aspects, including sample return objectives, sample collection techniques, experimental work to verify collection concepts, and some of the characteristics of the cometary targets for sample return.

Tsou, P.↗

Scientific objectives for a 1996 Mars Sample Return Mission

The Mars Sample Return Mission, designed to return a variety of surface and subsurface samples as well as atmospheric samples, is described. Primary information about the planet is essential to understanding its place in the evolution of the solar system. The most accurate landing techniques will be used to place the lander near geologically interesting features. A capable rover will be an essential element of the sample collection strategy to maximize the diversity of the samples. The sample collection and return systems will keep the samples at Mars ambient conditions or colder to preserve the abundances and distribution of volatile components. Planetary quarantine is an important consideration for both the Mars lander and the earth return vehicle. Quarantine procedures must be consistent with the primary objectives of the mission and must not compromise the investigations of the returned samples.

Blanchard, D. P.↗

Design of a sample acquistion system for the Mars exobiological penetrator

The Mars Exobiological Penetrator will be imbedded into several locations on the Martian surface. It contains various scientific instruments, such as an Alpha-Particle Instrument (API), Differential Scanning Calorimeter (DSC), Evolved Gas Analyzer (EGA) and accelerometers. A sample is required for analysis in the API and DSC. To avoid impact contaminated material, this sample must be taken from soil greater than 2 cm away from the penetrator shell. This study examines the design of a dedicated sampling system including deployment, suspension, fore/after body coupling, sample gathering and placement. To prevent subsurface material from entering the penetrator sampling compartment during impact, a plug is placed in the exit hole of the wall. A U-lever device is used to hold this plug in the penetrator wall. The U-lever rotates upon initial motion of the core-grinder mechanism (CGM), releasing the plug. Research points to a combination of coring and grinding as a plausible solution to the problem of dry drilling. The CGM, driven by two compressed springs, will be deployed along a tracking system. A slowly varying load i.e., springs, is favored over a fixed displacement motion because of its adaptability to different material hardness. However, to accommodate sampling in a low density soil, two dash pots set a maximum transverse velocity. In addition, minimal power use is achieved by unidirectional motion of the CGM. The sample will be transported to the scientific instruments by means of a sample placement tray that is driven by a compressed spring to avoid unnecessary power usage. This paper also explores possible modifications for size, weight, and time as well as possible future studies.

Thomson, Ron↗

Measurements of induced radioactivity in some LDEF samples

Twenty-six stainless steel trunnion samples, five aluminum end support retainer plate samples, two aluminum keel plate samples, and two titanium clips were analyzed. The shielded high purity germanium detectors used had efficiencies of 33, 54, and 80 pcts. at 1332 keV. Detector efficiencies as a function of energy and corrections for self absorption in the samples were determined with calibrated sources, unactivated control samples, and calculations. Several measurements were made on most samples. In the trunnion samples, Mn-54 and Co-57 were seen and limits were obtained for other isotopes. The results agree well with 1-D activation calculations for an anisotropic trapped proton model. In the aluminum samples, Na-22 and Be-7 were seen. Other results are presented.

Moss, C. E.↗

Measurements of induced radioactivity in some LDEF samples

Twenty-six stainless steel trunnion samples, five aluminum end support retainer plate samples, two aluminum keel plate samples, and two titanium clips were analyzed. The shielded high purity germanium detectors used had efficiencies of 33, 54, and 80 percent at 1332 keV. Detector efficiencies as a function of energy and corrections for self-absorption in the samples were determined with calibrated sources and unactivated control samples. Several measurements were made on most samples. In the trunnion samples, Mn-54 and Co-57 were seen and limits were obtained for other isotopes. The results agree well with 1-D activation calculations for an anisotropic trapped proton model. In the aluminum and titanium samples, Na-22 was detected. Other results are presented.

Moss, C. E.↗

A study of the influence of the data acquisition system sampling rate on the accuracy of measured acceleration loads for transport aircraft

A research effort was initiated at National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC), to describe the relationship between the sampling rate and the accuracy of acceleration loads obtained from the data acquisition system of a transport aircraft. An accelerometer was sampled and digitized at a rate of 100 samples per second onboard a NASA Boeing 737 (B-737) flight research aircraft. Numerical techniques were used to reconstruct 2.5 hours of flight data into its original input waveform and then re-sample the waveform into rates of 4, 8, 16, and 32 samples per second. Peak-between-means counting technique and power spectral analysis were used to evaluate each sampling rate using the 32 samples per second data as the comparison. This paper presents the results from these methods and includes in appendix A, the peak-between-means counting results used in a general fatigue analysis for each of the sampling rates.

Whitehead, Julia H.↗

Advancement of Solidification Processing Technology Through Real Time X-Ray Transmission Microscopy: Sample Preparation

Two types of samples were prepared for the real time X-ray transmission microscopy (XTM) characterization. In the first series directional solidification experiments were carried out to evaluate the critical velocity of engulfment of zirconia particles in the Al and Al-Ni eutectic matrix under ground (l-g) conditions. The particle distribution in the samples was recorded on video before and after the samples were directionally solidified. In the second series samples of the above two type of composites were prepared for directional solidification runs to be carried out on the Advanced Gradient Heating Facility (AGHF) aboard the space shuttle during the LMS mission in June 1996. X-ray microscopy proved to be an invaluable tool for characterizing the particle distribution in the metal matrix samples. This kind of analysis helped in determining accurately the critical velocity of engulfment of ceramic particles by the melt interface in the opaque metal matrix composites. The quality of the cast samples with respect to porosity and instrumented thermocouple sheath breakage or shift could be easily viewed and thus helped in selecting samples for the space shuttle experiments. Summarizing the merits of this technique it can be stated that this technique enabled the use of cast metal matrix composite samples since the particle location was known prior to the experiment.

Stefanescu, D. M.↗

Mars Sample Handling and Requirements Panel (MSHARP)

In anticipation of the return of samples from Mars toward the end of the first decade of the next century, NASA's Office of Space Sciences chartered a panel to examine how Mars samples should be handled. The panel was to make recommendations in three areas: (1) sample collection and transport back to Earth; (2) certification of the samples as nonhazardous; and (3) sample receiving, curation, and distribution. This report summarizes the findings of that panel. The samples should be treated as hazardous until proven otherwise. They are to be sealed within a canister on Mars, and the canister is not to be opened until within a Biosafety Hazard Level 4 (BSL-4) containment facility here on Earth. This facility must also meet or exceed the cleanliness requirements of the Johnson Space Center (JSC) facility for curation of extraterrestrial materials. A containment facility meeting both these requirements does not yet exist. Hazard assessment and life detection experiments are to be done at the containment facility, while geochemical characterization is being performed on a sterilized subset of the samples released to the science community. When and if the samples are proven harmless, they are to be transferred to a curation facility, such as that at JSC.

Carr, Michael H.↗

Proposed Science Requirements and Acquisition Priorities for the First Mars Sample Return

A sample return mission is an important next step in the exploration of Mars. The first sample return should come early in the program time-line because the science derived from earth-based analyses of samples provides crucial "ground truth" needed for further exploration planning, enhancement of remote measurements, and achieving science goals and objectives that include: (1) the search for environments that may support life and any indicators of the past or present existence of life, (2) understanding the history of water and climate on Mars, (3) understanding the evolution of Mars as a planet. Returned samples from Mars will have unique value because they can be studied by scientists worldwide using the most powerful analytical instruments available. Furthermore, returned Mars samples can be preserved for studies by future generations of scientists using new techniques and addressing new issues in Mars science. To ensure a high likelihood of success, the first sample return strategy should be simple and focused. We outline a fundamental set of sample requirements and acquisition priorities for Mars sample return.

Agee, C. B.↗

Performance Evaluation of Particle Sampling Probes for Emission Measurements of Aircraft Jet Engines

Considerable attention has been recently received on the impact of aircraft-produced aerosols upon the global climate. Sampling particles directly from jet engines has been performed by different research groups in the U.S. and Europe. However, a large variation has been observed among published data on the conversion efficiency and emission indexes of jet engines. The variation results surely from the differences in test engine types, engine operation conditions, and environmental conditions. The other factor that could result in the observed variation is the performance of sampling probes used. Unfortunately, it is often neglected in the jet engine community. Particle losses during the sampling, transport, and dilution processes are often not discussed/considered in literatures. To address this issue, we evaluated the performance of one sampling probe by challenging it with monodisperse particles. A significant performance difference was observed on the sampling probe evaluated under different temperature conditions. Thermophoretic effect, nonisokinetic sampling and turbulence loss contribute to the loss of particles in sampling probes. The results of this study show that particle loss can be dramatic if the sampling probe is not well designed. Further, the result allows ones to recover the actual size distributions emitted from jet engines.

Lee, Poshin↗

Laboratory Simulation of Space Weathering: ESR Measurements of Nanophase Metallic Iron in Laser-irradiated Olivine and Pyroxene Samples

S-type asteroids are believed to be parent bodies of ordinary chondrites. Although both S-type asteroids and ordinary chondrites contain the same mineral assemblage, mainly olivine and pyroxene, the reflectance spectra of the asteroids exhibit more overall depletion (darkening) and reddening, and more weakening of absorption bands relative to the meteorites. This spectral mismatch is explained by space weathering process, where high-velocity dust particle impacts should change the optical properties of the uppermost regolith surface of asteroids. In order to simulate the space weathering, we irradiated nanosecond pulse laser beam onto pellet samples of olivine (8.97wt% FeO) and pyroxene (enstatite: 9.88wt% FeO, hypersthene: 16.70wt%). We got spectral changes in our samples similar to that by space weathering on asteroids and confirmed nanophase alpha-metallic iron particles, which were theoretically predicted, not only on olivine but also on pyroxene samples by Transmission Electron Microscopy (TEM). Nanophase metallic iron particles were widely scattered throughout the amorphous rims developed along the olivine grains, whereas they were embedded in aggregates of amorphous in enstatite samples. Recently, we also measured laser-irradiated samples by ESR (Electron Spin Resonance). Strong ESR signals, characteristic to nanophase iron particles, are observed on irradiated olivine samples. In this paper, we report the quantities of nanophase metallic iron particles in pyroxene samples by ESR observations in addition to olivine samples.

Kurahashi, E.↗