Search NASA⌕ Search

SEARCH · Search NASA

Results for “squids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Design and characterization of the SPT-3G receiver (Conference Presentation)

(On behalf of the SPT-3G collaboration)The SPT-3G receiver was commissioned in early 2017 on the 10-meter South Pole Telescope (SPT) to map the Cosmic Microwave Background (CMB) with arcminute resolution. The new instrument significantly improves on previous SPT camera designs, offering unprecedented sensitivity to the CMB’s temperature and polarization anisotropies while maintaining a tight control on systematic effects.A restructured optics chain features new secondary and tertiary mirrors to increase the receiver’s field of view by a factor of four in area, coupling light through a set of four cryogenic 720 mm alumina elements, which re-image the Gregorian focus inside the receiver. The broad-band (70-270 GHz) anti-reflective coated lenses are paired with a Lyot stop and cooled to 4 K using a dedicated two-stage pulse-tube cooler (PTC) to minimize in-band attenuation, internal radiative loading, and stray light on the considerably larger focal plane, which is populated with ~2,700 diffraction-limited pixels.Each independent pixel incorporates a lenslet-coupled broadband sinuous antenna, which routes signals through superconducting transmission lines and in-line band-defining filters to six transition-edge sensors, each measuring one of three bands (90, 150, and 220 GHz) and two polarizations, yielding a total of ~16,000 bolometers distributed across ten 150 mm monolithic wafers on a 430 mm image plane. A robust mechanical and thermal architecture supports and cools all detectors across this sizable focal plane to ~250 mK using a closed-cycle Helium adsorption refrigerator backed by a PTC, allowing a duty cycle greater than 90%.This order of magnitude increase in detector count relies on an improved digital frequency-domain SQUID readout system which integrates superconducting inductor-capacitor resonators wired in series with each bolometer to achieve a 68x multiplexing factor while mitigating noise and crosstalk effects.Cumulatively, SPT-3G’s new optics, detector, and readout strategies boast a potential factor of ~20 improvement in mapping speed over its predecessor, SPT-Pol, offering the potential to improve our understanding of inflationary physics, astroparticle physics, and growth of structure. We summarize the new receiver’s core design principles, outline technology characterization results, and report on plans for future upgrades.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data for Magnetic Anisotropy due to Localized Structural Defects in Strained Yttrium Iron Garnet Thin Films

This dataset contains electron microscopy, magnetic, and X-ray diffraction characterization data for YIG/YSGG thin films associated with the manuscript "Magnetic anisotropy due to localized structural defects in strained yttrium iron garnet thin films". Characterizations include: scanning electron nano diffraction (SEND, or 4D-STEM), dark field transmission electron microscopy (DF-TEM), energy dispersive X-ray spectroscopy (EDS), ferrimagnetic resonance (FMR), superconducting quantum interference device (SQUID), scanning transmission electron microscopy (STEM), X-ray diffraction (XRD).

Electron microscopy↗

Synthesis and behavior of bulk iron nitride soft magnets via high-pressure spark plasma sintering

Abstract In this study, dense bulk iron nitrides (Fe x N) were synthesized for the first time ever using spark plasma sintering (SPS) of Fe x N powders. The Fe 4 N phase of iron nitride in particular has significant potential to serve as a new soft magnetic material in both transformer and inductor cores and electrical machines. The density of SPSed Fe x N increased with SPS temperature and pressure. The microstructure of the consolidated bulk Fe x N was characterized with X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and superconducting quantum interference device (SQUID) magnetometry. XRD revealed a primary phase of Fe 4 N with secondary phases of Fe 3 N and metallic iron. Finite element analysis (FEA) was also applied to investigate and explain localized heating and temperature distribution during SPS. The effects of processing on interface bonding formation and phase evolution were investigated and discussed in detail to provide insight into fundamental phenomena and microstructural evolution in SPSed Fe x N. Graphic abstract

36 MATERIALS SCIENCE↗

Tuned cavity magnetometer sensitivity.

We have developed a high sensitivity (<pico Tesla/{radical}Hz), non-cryogenic magnetometer that utilizes a novel optical (interferometric) detection technique. Further miniaturization and low-power operation are key advantages of this magnetometer, when compared to systems using SQUIDs which require liquid Helium temperatures and associated overhead to achieve similar sensitivity levels.

47 OTHER INSTRUMENTATION↗

Atom chip microscopy: A novel probe for strongly correlated materials

Improved measurements of strongly correlated systems will enable the predicative design of the next generation of supermaterials. In this program, we are harnessing recent advances in the quantum manipulation of ultracold atomic gases to expand our ability to probe these technologically important materials in heretofore unexplored regions of temperature, resolution, and sensitivity parameter space. We are working to demonstrate the use of atom chips to enable single-shot, large area detection of magnetic flux at the 10 -7 flux quantum (Φ 0 ) level and below. By harnessing the extreme sensitivity of atomic clocks and Bose-Einstein condensates (BECs) to external perturbations, the cryogenic atom chip technology developed here will provide a magnetic flux detection capability that surpasses other techniques---such as scanning SQUIDs---by a factor of 10 1 --10 3 . We are testing the utility of this technique by using rubidium BECs to image the magnetic fields emanating from charge transport and magnetic domain percolation in strongly correlated materials as they undergo temperature-tuned metal--to--insulator phase transitions. Cryogenic atom chip microscopy introduces three very important features to the toolbox of high-resolution, strongly correlated material microscopy: simultaneous detection of magnetic and electric fields (down to the sub-single electron charge level); no invasive large magnetic fields or gradients; simultaneous micro- and macroscopic spatial resolution; freedom from 1/f flicker noise at low frequencies; and, perhaps most importantly, the complete decoupling of probe and sample temperatures. The first of these features will play an important role in studying the interplay between magnetic and electric domain structure. The last two are crucial for low frequency magnetic noise detection in, e.g., the cuprate pseudogap region and for precision measurements of transport in the high temperature, technologically relevant regime inaccessible to other techniques based on superconducting scanning probes. In periods 1--3 of this grant, which we now close at the University of Illinois at Urbana-Champaign and restart at Stanford University where our new lab is being built, we have demonstrated the ability to rapidly create Rb BECs and trap them within microns of a surface in a cryostat. Period 4 of this grant, to be performed at Stanford, will demonstrate the feasibility of using atom chips with a BEC to image transport features on a cryogenically cooled surface. Successful demonstration, in future funding cycles, will lead directly to the use of system for studies of transport in exotic and technologically relevant materials such as cuprate superconductors and topological insulators.

74 ATOMIC AND MOLECULAR PHYSICS↗

Magnetic Microcalorimeter Gamma Detectors for High-Precision Non-Destructive Analysis

Cryogenic gamma (γ) detectors with operating temperatures of ~0.1 K offer 10× better energy resolution than conventional high-purity germanium detectors that are currently used for non-destructive analysis (NDA) of nuclear materials. This can greatly increase the accuracy of NDA, especially at low-energies where gamma rays often have similar energies and cannot be resolved by Ge detectors. Among the different cryogenic detector types, Magnetic Micro-Calorimeters (MMCs) have the potential of faster count rates and better linearity. High linearity is essential to add spectra from different pixels in detector arrays that are needed for high sensitivity. MMC gamma detectors measure the energy of absorbed gamma rays form the resulting change in magnetization of an erbium-doped gold (Au:Er) sensor. The signal is read out with a SQUID preamplifier and processed digitally with room temperature electronics (see inset figure 2). The objective of this project is to develop ultra-high energy resolution γ-detectors based on magnetic micro-calorimeters (MMCs) for accurate non-destructive isotope analysis (NDA). Since MMCs, like other cryogenic γ-detector technologies with operating temperatures <0.1 K, are intrinsically slow and have to be small for high resolution, special emphasis will be placed on questions that determine sensitivity and the potential for scaling to arrays. Objectives for FY14 were therefore to fabricate an improved version of MMC γ-detectors and test their energy resolution, maximum count rate, readout noise, crosstalk between pixels and linearity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exchange interactions of paramagnetic spins on α-Al 2 O 3

Superconducting qubits (SQs) represent a promising route to achieving a scalable quantum computer. However, the coupling between SQs and (as yet largely unidentified) parasitic noise sources has so far limited the functionality of current SQs by reducing the coherence time of the quantum states below a practical threshold for measurement and manipulation. These noise sources also more generally limit the performance of a variety of devices based on superconducting circuits, including high energy-resolution cryogenic radiation detectors, sensitive magnetic detectors (superconducting quantum interference devices, or SQUIDs), nanomechanical motion sensors and quantum-limited parametric amplifiers. In this paper, we study the origins of spin interactions on a substrate using OH on sapphire as a model system. We show how the substrate can mediate spin-spin interactions generally favoring FM interactions, but that strain can modify the interaction. Surface and sub-surface defects between the spin defects may also enhance the exchange interactions.

36 MATERIALS SCIENCE↗

Low-T magnetometry study of S = 1 Q2D [Ni(pyz) 2 (H 2 O) 2 ](BF 4 ) 2 (pyz = pyrazine)

[Ni(pyz) 2 (H 2 O) 2 ](BF 4 ) 2 (pyz = N 2 C 4 H 4 ) was synthesized by a solvent-free technique and its structure solved by synchrotron X-ray powder diffraction.1 The compound contains S = 1 Ni(II) ions and has tetragonal symmetry. Two-D [Ni(pyz) 2 (H 2 O) 2 ] 2+ square lattices propagate in the ab-plane and stack along the c-axis (Fig. 1). Water ligands occupy axial sites and form H-bonds with interlayer BF 4 - ions. SQUID magnetometry shows a possible transition to long-range magnetic order near 3 K. We measured the magnetization of [Ni(pyz) 2 (H 2 O) 2 ](BF 4 ) 2 as a function of temperature to search for field-induced phase transitions and briefly report those findings here.

36 MATERIALS SCIENCE↗

P13631-E002PF: Pulsed field magnetostriction of Ba 2 CoTeO 6

Ba 2 CoTeO 6 is an insulating material consisting of two magnetic subsystems referred as A and B build of S=1/2 spins. Subsystem A is considered to be a Heisenberg-like antiferromagnet (AFM) on a triangular lattice and subsystem B is a J 1 -J 2 Ising-like AFM on a honey-comb lattice. The magnetic phase transitions are observed at T N1 = 12 K and T N2 =3K for A and B respectively. The application of magnetic fields unveils a rich phase diagram that varies depending on the direction of the applied field for either H ll c or H perp c. To date the phase diagram has been investigated by means of specific heat measurement up to 9T and susceptibility measurements with a SQUID magnetometer up to 7T. Magnetization measured in pulsed magnetic fields up to 60T at 1.3K and 4.2K reveal several steps and plateaux occurring at varying critical fields depending on the crystallographic direction. Common to the magnetization parallel c and perpendicular c is the saturation above 40T.

36 MATERIALS SCIENCE↗

Design of a Dry Dilution Refrigerator for MMC Gamma Detector Arrays

The goal of this LCP is to develop an ultra-high resolution gamma detector based on magnetic microcalorimeters (MMCs) for accurate non-destructive analysis (NDA) of nuclear materials. For highest energy resolution, we will introduce erbium-doped silver (Ag:Er) as a novel sensor material to replace current Au:Er sensors. The detector sensitivity will be increased by developing arrays of 32 Ag:Er pixels read out by 16 SQUID preamplifiers. MMC detectors require operating temperatures of ~15 mK and thus the use of a dilution refrigerator, and the desire for user-friendly operation without cryogenic liquids requires that this refrigerator use pulse-tube pre-cooling to ~4 K. For long-term reliability, we intend to re-design the heat switch that is needed to apply the magnetizing current to the Ag:Er sensor and that used to fail in earlier designs after months of operation. A cryogenic Compton veto will be installed to reduce the spectral background of the MMC, especially at low energies where ultra-high energy resolution is most important. The goals for FY16 were 1) to purchase a liquid-cryogen-free dilution refrigerator and adapt it for MMC operation, and 2) to fabricate Ag:Er-based MMC γ-detectors with improved performance and optimize their response. This report discusses the design of the instruments, and progress in MMC detector fabrication. Details of the MMC fabrication have been discussed in an April 2016 report to DOE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing Quantum Levitation of ICF Capsules Coated with MgB 2 Thin Films

Current inertial confinement fusion (ICF) capsule support technologies create implosion perturbations which reduce fusion yield, driving the search for new support paradigms. Quantum levitation of the capsule will eliminate the requirement of a physical support structure, increasing fusion yield. The application of an external magnetic field to a capsule coated with a superconducting film can provide the necessary conditions for levitation. Magnesium diboride (MgB 2 ) is an attractive option for ICF applications as it has a high reported superconducting transition temperature of 39 K and is a low Z compound. This project is part of an ongoing effort which seeks to coat ICF capsules with a thin layer of superconducting MgB 2 . This project studied the synthesis of MgB 2 and diffusion/reaction kinetics of B/Mg/B m ultilayer thin films. These films were sputter deposited on flat glassy carbon substrates. Films were annealed in a tube furnace at temperatures between 400 °C and 650 °C for a total of 29 hours with film characterization done at predetermined intervals. At each interval, superconducting properties of the samples were evaluated with superconducting quantum interference device (SQUID) magnetometry, while Rutherford backscattering (RBS) with 2 MeV 4 He + ions was done to determine the composition and depth profile of the films. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) were used to characterize surface morphology. Superconducting behavior was observed in thin films annealed at and above 450 °C. Formation of superconducting MgB 2 at 450 °C h as not been previously reported below 500 °C. The surface of the samples annealed at 500 °C and below was smooth with a measured roughness of ~3 nm. After 29 hours of annealing time, the 450 °C sample had a transition temperature of 27.3 K. The highest transition temperature measured was 30.9 K and was associated with a sample annealed for 29 hours at 650 °C. Transition temperatures were weakly positively correlated with annealing temperature and showed dependence on initial structural quality and oxygen contamination. Current research is attempting to synthesize superconducting MgB 2 coatings on spherical Si beads with the findings of this study. Future efforts are focused on the construction and testing of a levitation apparatus.

36 MATERIALS SCIENCE↗

Quantum Sensing and its Potential for Nuclear Safeguards

Quantum sensing has the potential to provide ultrasensitive measurements of physical phenomenon. Unlike quantum computing, quantum sensing is available now, though in general at research laboratories. A notable commercially-available quantum sensing device is the ubiquitous Superconducting Quantum Interference Device (SQUID), which can measure faint magnetic fields such as found in the human brain. Quantum sensing is used for direct measurement of environmental phenomenon, such as electromagnetic fields and accelerations, which then are used for certain applications. For example, quantum sensing of accelerations is useful for Position, Navigation, and Timing (PNT) applications. It is not clear, however, how quantum sensing can be useful for nuclear safeguards. This report provides first a background in quantum sensing, followed by a survey of potential safeguards utilizations of quantum sensing. Several potential safeguards applications are identified and explored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bio-Based Phase Change Materials (PCMs) for Thermal Energy Storage (Final Scientific/Technical Report)

The goal of this project is to develop a novel bio-based phase change material (PCM) derived from squid ring teeth (SRT) proteins, and design a prototype heat exchanger based on these bio-based PCMs for energy storage and dynamic heat exchange for building thermal energy storage systems. The PCMs, derived from SRT proteins, will demonstrate room temperature energy storage capacities and switchable thermal conductivities that redefine the current state-of-the-art (SOA) for building thermal energy storage. Further, in a single material and with a single manufacturing processes, our proposed thermal battery will be developed with “on demand” thermal conductivity for rapid charging/discharging but superior insulation during energy storage periods. More specifically, our bio-based PCMs have demonstrated: 1) the potential for increased energy storage capacity (i.e., greater than paraffines at room temperature); 2) tunability in thermal conductivity with the largest thermal conductivity switching ratios for an intrinsic material reported to date, and 3) a 100% recyclable and biodegradable PCM with low volatility and toxicity and scalability in its manufacture for both residential and commercial applications. The already established ability for roll-to-roll processing of these non-toxic, non-flammable SRT composites along with their carbon-neutral manufacturing processes that has been pioneered by our team make this solution a disruptive and impactful technology to redefine the current SOA of energy storage technologies. The outcomes of this effort have been: 1) the identification of new bio-based PCM that establishes a new SOA for thermal conductivity and energy storage density at room temperature and 2) the development of a new experimental technique to measure the energy storage density via latent heat measurements during melting of thin films. This new technique can be applied to thin films (as thin as < 1 micrometer), and represents a novel approach for thin film energy storage density measurements. Dynamic thermal energy storage is the missing technology that will enable a grid- interactive efficient building (GEB). For a “smart” building capable of connecting with the power grid, the media must be inexpensive and possess thermal switching capabilities to control the time-dependent heat flow into (and out of) the PCM on demand. Unique to the material system in this program, programmable SRT-based PCM show improvements as compared to traditionally used PCMs, and thus its technical performance will represent a leap forward for the future GEB concept.

25 ENERGY STORAGE↗

Surface Characterization of NbTiN multilayer films for accelerator applications

Further enhancement of superconducting accelerating cavity performance calls upon the development of materials beyond bulk niobium (Nb). Superconducting RF (SRF) is a surface phenomenon; for most superconducting materials the RF penetration depth is in the range of hundreds of nanometers. Due to the field penetration enhancement occurring in films with a thickness smaller than their nominal penetration depth, multilayer superconductor/insulator/superconductor (SIS) structures are theorized to have potential to support surface magnetic fields beyond the reach of the current SRF cavities. A candidate superconductor for SIS structures is the ternary compound NbTiN. SIS structures based on NbTiN and AlN are currently under development at JLab. NbTiN can be deposited with nominal superconducting parameters using DC reactive magnetron sputtering. This contribution presents the characterization of surface, material and superconducting properties of NbTiN films and SIS structures. Notably, the first flux penetration (Hfp) measured by SQUID magnetometry of 200 to 5 nm thick films and Hfp enhancement by multilayer structures is evaluated.

Beringer, Douglas↗

Nanofabrication techniques of Josephson junction for transmon qubit

This report deals with the theory of transmon qubits in general, also focusing on the SQUID and the functioning of a Josephson junction. The interaction of the qubit in a cavity with the quantized electro-magnetic field is then treated. After this introduction whose goal is to contextualize the work that I actually did, I will talk about the 2D and 3D qubits that we have built. The problem of etching and "patching" will be dealt with in detail, reporting the results obtained in the laboratory. Finally, I wanted to conclude by addressing the concept of measurement of a qubit in a cavity only at a theoretical level. I conclude everything with a "Feynman treatment" of the cavities which in my opinion is really very interesting.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Observation of critical scaling in spin glasses below T c using thermoremanent magnetization

Time-dependent thermoremanent magnetization (TRM) studies have been instrumental in probing energy dynamics within the spin glass phase. In this paper, we review the evolution of the TRM experiment over the last half century and discuss some aspects related to how it has been used in the understanding of spin glasses. We also report on recent experiments using high-resolution DC SQUID magnetometry to probe the TRM at temperatures less than but near to the transition temperature T c . These experiments have been performed as a function of waiting time, temperature, and five different magnetic fields. We find that as the transition temperature is approached from below, the characteristic time scale of TRM is suppressed up to several orders of magnitude in time. In the highest-temperature region, we find that the waiting time effect subsides, and a waiting time-independent crossover line is reached. We also find that increasing the magnetic field further suppresses the crossover line. Using a first-principles energy argument across the crossover line, we derive an equation that is an excellent fit to the crossover lines for all magnetic fields probed. The data show strong evidence for critical slowing down and an H = 0 Oe phase transition.

36 MATERIALS SCIENCE↗

Peripheral Nerve Magnetoneurography With Optically Pumped Magnetometers

Electrodiagnosis is routinely integrated into clinical neurophysiology practice for peripheral nerve disease diagnoses, such as neuropathy, demyelinating disorders, nerve entrapment/impingement, plexopathy, or radiculopathy. Measured with conventional surface electrodes, the propagation of peripheral nerve action potentials along a nerve is the result of ionic current flow which, according to Ampere’s Law, generates a small magnetic field that is also detected as an “action current” by magnetometers, such as superconducting quantum interference device (SQUID) Magnetoencephalography (MEG) systems. Optically pumped magnetometers (OPMs) are an emerging class of quantum magnetic sensors with a demonstrated sensitivity at the 1 fT/√Hz level, capable of cortical action current detection. But OPMs were ostensibly constrained to low bandwidth therefore precluding their use in peripheral nerve electrodiagnosis. With careful OPM bandwidth characterization, we hypothesized OPMs may also detect compound action current signatures consistent with both Sensory Nerve Action Potential (SNAP) and the Hoffmann Reflex (H-Reflex). In as much, our work confirms OPMs enabled with expanded bandwidth can detect the magnetic signature of both the SNAP and H-Reflex. Taken together, OPMs now show potential as an emerging electrodiagnostic tool.

60 APPLIED LIFE SCIENCES↗

Relevance of the Preparation of the Target for PLD on the Magnetic Properties of Films of Iron-Doped Indium Oxide

This paper concerns the importance of the preparation of the targets that may be used for pulsed laser deposition of iron-doped indium oxide films. Targets with a fixed concentration of iron are fabricated from indium oxide and iron metal or one of the oxides of iron, FeO, Fe3O4 and Fe2O3. Films from each target were ablated onto sapphire substrates at the same temperature under different oxygen pressures such that the thickness of the films was kept approximately constant. The films were studied using X-ray diffraction, X-ray absorption (both XANES and EXAFS), optical absorption and magnetic circular dichroism. The magnetic properties were measured with a SQUID magnetometer. At the lowest oxygen pressure, there was evidence that some of the iron ions in the films were in the state Fe2+, rather than Fe3+, and there was also a little metallic iron; these properties were accompanied by a substantial magnetisation. As the amount of the oxygen was increased, the number of defect phases and the saturation magnetisation was reduced and the band gap increased. In each case, we found that the amount of the oxygen that had been included in the target from the precursor added to the effect of adding oxygen in the deposition chamber. It was concluded that the amount of oxygen in the target due to the precursor was an important consideration but not a defining factor in the quality of the films.

(InFe)2O3↗