At least 523 records · Page 29

Ice nucleating particle concentrations measured by the PNNL-CFDC during the AGINSGP field experiment

Real-time, immersion mode ambient ice nucleating particle (INP) concentrations were measured at ARM’s Southern Great Plains (SGP) site during the AGINSGP field experiment using a continuous flow diffusion chamber (CFDC) from Pacific Northwest National Laboratory (PNNL). The PNNL-CFDC is an ice-thermal gradient diffusion chamber that optically detects the freezing of single aerosol particles (Kulkarni et al. 2020). The instrument was located in the guest instrument facility (GIF) and measured INP concentrations from April 8th to April 29th. Air was drawn into the GIF through custom aluminum stack inlets (6” inner diameter) attached vertically to the outer GIF wall and the GIF outside platform. A blower pulled air through the stacks at a velocity of 1 m/s. Aerosol instruments subsampled via wall ports, through either 3/8” or 1/4" copper lines, depending on sample flow of the instrument. Kulkarni, G., Hiranuma, N., Möhler, O., Höhler, K., China, S., Cziczo, D. J., & DeMott, P. J. (2020). A new method for operating a continuous-flow diffusion chamber to investigate immersion freezing: Assessment and performance study. Atmospheric Measurement Techniques, 13(12), 6631–6643. https://doi.org/10.5194/amt-13-6631-2020.

54 ENVIRONMENTAL SCIENCES↗

Ice nucleating particle concentrations measured by the CSU-CFDC during the AGINSGP field experiment

Real-time, immersion mode ambient ice nucleating particle (INP) concentrations were measured at ARM&rsquo;s Southern Great Plains (SGP) site during the AGINSGP field experiment using a continuous flow diffusion chamber (CFDC) from Colorado State University (CSU). The CSU-CFDC is an ice-thermal gradient diffusion chamber that optically detects the freezing of single aerosol particles (Rogers 1988; Rogers et al. 2001; and Eidhammer et al. 2010). The instrument was located in the guest instrument facility (GIF) and measured INP concentrations from April 8th to April 29th. Air was drawn into the GIF through custom aluminum stack inlets (6&rdquo; inner diameter) attached vertically to the outer GIF wall and the GIF outside platform. A blower pulled air through the stacks at a velocity of 1 m/s. Aerosol instruments subsampled via wall ports, through either 3/8&rdquo; or 1/4" copper lines, depending on sample flow of the instrument. Rogers, D. C., Development of a continuous flow thermal gradient diffusion chamber for ice nucleation studies, Atmospheric Research, 22(2), 149-181, doi:10.1016/0169-8095(88)90005-1, 1988. Rogers, D. C., P. J. DeMott, S. M. Kreidenweis and Y. Chen, A continuous flow diffusion chamber for airborne measurements of ice nuclei, J. Atmos. Oceanic Technol., 18, 725-741, doi:10.1175/1520-0426(2001)018<0725:ACFDCF>2.0.CO;2, 2001. Eidhammer, T., DeMott, P. J., Prenni, A. J., Petters, M. D., Twohy, C. H., Rogers, D. C., Stith, J., Heymsfield, A., Wang, Z., Haimov, S., French, J., Pratt, K., Prather, K., Murphy, S., Seinfeld, J., Subramanian, R., and Kreidenweis, S. M., Ice initiation by aerosol particles: Measured and predicted ice nuclei concentrations versus measured ice crystal concentrations in an orographic wave cloud, J. Atmos. Sci., 67, 2417-2436, doi:10.1175/2010JAS3266.1, 2010

54 ENVIRONMENTAL SCIENCES↗

Fluorescent bioaerosol particle concentrations measured by the DU WIBS during the AGINSGP field experiment

Real-time, immersion mode ambient fluorescent bioaerosol concentrations were measured at ARM’s Southern Great Plains (SGP) site during the AGINSGP field experiment using a Wideband Integrated Bioaerosol Sensor (DMT Inc.; WIBS-4A). The WIBS-4A is an optical particle counter that also measures single particle fluorescence in three channels, along with particle asymmetry. Particles are grouped into different types depending on which channels they fluoresce in. The instrument was located in the guest instrument facility (GIF) and measured fluorescent particle concentrations from April 7th to April 29th. Data presented here are the concentrations for each particle type, binned in 5 minute increments. Air was drawn into the GIF through custom aluminum stack inlets (6” inner diameter) attached vertically to the outer GIF wall and the GIF outside platform. A blower pulled air through the stacks at a velocity of 1 m/s. Aerosol instruments subsampled via wall ports, through either 3/8” or 1/4" copper lines, depending on sample flow of the instrument. Particles were dried using a silica diffusion dryer prior to analysis.

54 ENVIRONMENTAL SCIENCES↗

Site Environmental Report for 2009, Volume 2

Volume II of the Site Environmental Report for 2009 is provided by Ernest Orlando Lawrence Berkeley National Laboratory as a supplemental appendix to Volume I, which contains the body of the report. Volume II contains the environmental monitoring and sampling data used to generate summary results of routine and nonroutine sampling at the Laboratory, except for groundwater sampling data, which may be found in the reports referred to in Chapter 4 of Volume I. The results from sample collections are more comprehensive in Volume II than in Volume I: for completeness, all results from sample collections that began or ended in calendar year (CY) 2009 are included in this volume. However, the samples representing CY 2008 data have not been used in the summary results that are reported in Volume I. (For example, although ambient air samples collected on January 6, 2009, are presented in Volume II, they represent December 2008 data and are not included in Table 4-2 in Volume I.) When appropriate, sampling results are reported in both conventional and International System (SI) units. For some results, the rounding procedure used in data reporting may result in apparent differences between the numbers reported in SI and conventional units. (For example, stack air tritium results reported as < 1.5 Bq/m3 are shown variously as < 39 and < 41 pCi/m3. Both of these results are rounded correctly to two significant digits.)

57↗

GaAs structures with InAs and As quantum dots produced in a single molecular beam epitaxy process

Epitaxial GaAs layers containing InAs semiconductor quantum dots and As metal quantum dots are grown by molecular beam epitaxy. The InAs quantum dots are formed by the Stranskii-Krastanow mechanism, whereas the As quantum dots are self-assembled in the GaAs layer grown at low temperature with a large As excess. The microstructure of the samples is studied by transmission electron microscopy. It is established that the As metal quantum dots formed in the immediate vicinity of the InAs semiconductor quantum dots are larger in size than the As quantum dots formed far from the InAs quantum dots. This is apparently due to the effect of strain fields of the InAs quantum dots upon the self-assembling of As quantum dots. Another phenomenon apparently associated with local strains around the InAs quantum dots is the formation of V-like defects (stacking faults) during the overgrowth of the InAs quantum dots with the GaAs layer by low-temperature molecular beam epitaxy. Such defects have a profound effect on the self-assembling of As quantum dots. Specifically, on high-temperature annealing needed for the formation of large-sized As quantum dots by Ostwald ripening, the V-like defects bring about the dissolution of the As quantum dots in the vicinity of the defects. In this case, excess arsenic most probably diffuses towards the open surface of the sample via the channels of accelerated diffusion in the planes of stacking faults.

36 MATERIALS SCIENCE↗

Preparation and characterization of microwave absorbing composite materials with GSs or FeCo/GS composites

Highlights: • It is found that adding GSs or FeCo/GSs composite into the sample SiC/NR can greatly increase RL and the absorbing peak shifts to low-frequency with increasing the adding amount. • The optimum adding amount of GSs is 2%. The sample GS-200-2% possesses the lowest RL value of −31.27 dB at 7.6 GHz. • The optimum adding amount of FeCo/GSs composite is 3%. The sample AGS-450-3% possesses the lowest RL value of −20.67 dB at 7.8 GHz. - Abstract: This study mainly explored the synthesis method of graphene sheets (GSs) and FeCo/graphene sheet (FeCo/GS) composites and evaluated the microwave absorbing characteristics of composite materials containing GSs or FeCo/GS composites. First, graphite oxide (GO) was synthesized by the modified Hummers method. The synthesized GO was further used to synthesize GSs and FeCo/GS composites. Afterward, GSs or FeCo/GS composites were mixed with silicon carbide (SiC) and natural rubber (NR) to prepare microwave absorbing materials with thicknesses of 2 mm. Finally, identification and characterization of these samples were performed by XRD, FE-SEM, TEM, TGA, ESCA, RS, AFM and VNA. GSs were synthesized successfully at a low annealing temperature of 200 °C, and their thicknesses were between 0.848 nm and 2.115 nm, which corresponds to 2–6 stacked layers of graphene. FeCo/GS composites were also synthesized successfully at three different annealing temperatures. The nanoparticles of metals and metal oxides were well-dispersed on the surfaces of and the spaces between GSs. It was found that adding GSs or FeCo/GS composites into the SiC/NR sample can greatly increase reflection loss (RL) and that the absorbing peak shifts to lower frequencies as the concentration of added particles increases. The optimum concentration of added GSs was 2 wt.%. The GS-200-2% sample possessed the lowest RL value of −31.27 dB at 7.6 GHz. The optimum concentration of added FeCo/GS composites was 3 wt.%. The AGS-450-3% sample possessed the lowest RL value of −20.67 dB at 7.8 GHz.

36 MATERIALS SCIENCE↗

Direct observations of crystal defects in polycrystalline diamond

Highlights: • Electron channeling contrast imaging of crystal defects in polycrystalline diamond • Introducing acid etching as a novel protocol for diamond surface preparation • Characterization of {111} twins, {111} stacking faults and {111} helical dislocations in diamond using ECCI and EBSD - Abstract: Crystal defects are abundant in synthetic diamond produced by chemical vapor deposition (CVD). We present the first images of crystal defects in a bulk polycrystalline CVD diamond sample using general electron channeling contrast imaging (ECCI) in a field emission scanning electron microscope (FE-SEM). For enhancement of channeling contrast of this material, we introduce a novel protocol for diamond surface preparation that involves acid etching. Using this protocol, we imaged three types of crystal defects including twins, stacking faults and dislocations. Each defect was identified based on its appearance in electron channeling contrast (ECC) micrographs. We analyzed grains containing twins and dislocations using electron backscatter diffraction (EBSD) crystal orientation mapping. We found a large population of grains that contained Σ3 type twins on {111} planes with a 60°<111> angle–axis pair of misorientation for twin boundaries. In addition, we identified {111} stacking faults and {111} helical dislocations. These observations are in agreement with reports of crystal defects in CVD diamond thin foils studied by a transmission electron microscope (TEM).

36 MATERIALS SCIENCE↗

DHS Research Experience Summary

I learned a great deal during my summer internship at Lawrence Livermore National Laboratory (LLNL). I plan to continue a career in research, and I feel that my experience at LLNL has been formative. I was exposed to a new area of research, as part of the Single Particle Aerosol Mass Spectrometry (SPAMS) group, and I had the opportunity to work on projects that I would not have been able to work on anywhere else. The projects both involved the use of a novel mass spectrometer that was developed at LLNL, so I would not have been able to do this research at any other facility. The first project that Zachary and I worked on involved using SPAMS to detect pesticides. The ability to rapidly detect pesticides in a variety of matrices is applicable to many fields including public health, homeland security, and environmental protection. Real-time, or near real-time, detection of potentially harmful or toxic chemical agents can offer significant advantages in the protection of public health from accidental or intentional releases of harmful pesticides, and can help to monitor the environmental effects of controlled releases of pesticides for pest control purposes. The use of organophosphate neurotoxins by terrorists is a possibility that has been described; this is a legitimate threat, considering the ease of access, toxicity, and relatively low cost of these substances. Single Particle Aerosol Mass Spectrometry (SPAMS) has successfully been used to identify a wide array of chemical compounds, including drugs, high explosives, biological materials, and chemical warfare agent simulants. Much of this groundbreaking work was carried out by our group at LLNL. In our work, we had the chance to show that SPAMS fulfills a demonstrated need for a method of carrying out real-time pesticide detection with minimal sample preparation. We did this by using a single particle aerosol mass spectrometer to obtain spectra of five different pesticides. Pesticide samples were chosen to represent four common classes of pesticides that are currently used in the US. Permethrin (a pyrethrin insecticide), dichlorvos and malathion (organophosphates), imidacloprid (a chloronicotinyl pesticide), and carbaryl (a carbamate) were selected for analysis. Samples were aerosolized either in water (using a plastic nebulizer) or in ethanol (using a glass nebulizer), and the particles entered the SPAMS instrument through a focusing lens stack. The particles then passed through a stage with three tracking lasers that were used to determine each particle's velocity. This velocity was used to calculate when to fire a desorption/ionization (D/I) laser in order to fragment the particle for analysis in a dual polarity time of flight mass spectrometer. Signals were digitized, and then analyzed using LLNL-developed software. We obtained chemical mass spectral signatures for each pesticide, and assigned peaks to the mass spectra based on our knowledge of the pesticides chemical structures. We then proved the robustness of our detection method by identifying the presence of pesticides in two real-world matrices: Raid{trademark} Ant Spray and a flea collar. To sample these, we simply needed to direct aerosolized particles into the SPAMS instrument. The minimal sample preparation required makes SPAMS very attractive as a detector. Essentially, we were able to show that SPAMS is a reliable and effective method for detecting pesticides at extremely low concentrations in a variety of matrices and physical states. The other project that I had the opportunity to be a part of did not involve data collection in the lab; it consisted of analyzing a large amount of data that had already been collected. We got to look at data collected over the course of about two months, when the SPAMS instrument was deployed to a public place. The machine sampled the air and collected spectra for over two months, storing all the spectra and associated data; we then looked at an approximately two-month subset of this data to search for patterns in the types of particles being detected. Essentially, we were able to identify particle types among all the spectra collected by clustering the spectra into groups of similar spectra. This was done using software that had been previously developed by our group (Dr. Paul Steele, a former group member, was instrumental in helping us learn how to use the software). Once we had found particles that seemed to recur, we faced the task of trying to figure out what these particles were. To do this, we compared the average spectra for each major cluster to those of several common compounds. We were able to tentatively identify at least one compound this way. We also looked at patterns in the appearance of different compounds. For instance, there were some compounds that only appeared at certain times of the day.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RAPID SEPARATION METHOD FOR ACTINIDES IN EMERGENCY SOIL SAMPLES

A new rapid method for the determination of actinides in soil and sediment samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used for samples up to 2 grams in emergency response situations. The actinides in soil method utilizes a rapid sodium hydroxide fusion method, a lanthanum fluoride soil matrix removal step, and a streamlined column separation process with stacked TEVA, TRU and DGA Resin cartridges. Lanthanum was separated rapidly and effectively from Am and Cm on DGA Resin. Vacuum box technology and rapid flow rates are used to reduce analytical time. Alpha sources are prepared using cerium fluoride microprecipitation for counting by alpha spectrometry. The method showed high chemical recoveries and effective removal of interferences. This new procedure was applied to emergency soil samples received in the NRIP Emergency Response exercise administered by the National Institute for Standards and Technology (NIST) in April, 2009. The actinides in soil results were reported within 4-5 hours with excellent quality.

54 ENVIRONMENTAL SCIENCES↗

Physicochemical properties of digital light processing 3D-Printed alumina and mullite ceramics

Alumina ceramics fabricated using conventional techniques such as uniaxial pressing or injection molding are popular due to their low density, excellent insulation, and mechanical properties. However, these methods often limit the fabrication of complex geometries with high dimensional accuracy due to tooling constraints and limited design freedom. To overcome these limitations, this study employed Digital Light Processing (DLP) additive manufacturing (AM), which enables the production of precise structures. In addition, the optimization of sintering parameters to enhance the densification and performance of alumina and mullite ceramics was investigated, with a specific focus on how varying sintering temperatures and hold times affect part shrinkage, geometric accuracy, and material integrity. Flexural strength of both alumina and mullite specimens was clearly influenced by the way the layers was stacked. When layers were arranged across the direction of the applied load (Z = 4; XZ), the strength was higher than when they were stacked along the same direction as the load (Z = 3; XY). Weibull analysis based on these results showed high modulus values across all samples, indicating good reliability in the flexural strength measurements. This reliability, combined with the clear influence of sintering parameters, highlights how processing conditions effect the material properties and mechanical performance of parts produced through DLP additive manufacturing. In conclusion, these findings open new avenues for ceramic AM across various applications, enhancing the potential for innovation in fields such as aerospace, biomedical engineering, and energy.

36 MATERIALS SCIENCE↗

10 Be at iThemba LABS using a silicon nitride membrane stack as absorber for isobar suppression

10 Be is an important isotope for accelerator mass spectrometry (AMS) because of the demand for cosmogenic radionuclide dating methods in the earth science and paleo-sciences community. At the iThemba Laboratory for Accelerator Based Science (iThemba LABS) we implemented full suppression of the interfering isobar 10 B using a silicon nitride foil-stack, utilizing the 2+ charge state for high efficiency. We demonstrate the performance of this newly established AMS system using standards and test samples. Here we further present the results of an inter-comparison between iThemba LABS and the Center for Accelerator Mass Spectrometry/Lawrence Livermore National Laboratory, on AMS samples prepared from purified quartz at the University of Vermont. The results for 10 Be from the laboratories are in close agreement, fully consistent with cross-calibration between them. AMS results for 26 Al are in similarly good agreement, demonstrating the performance and accuracy of iThemba LABS for the most commonly measured in situ produced cosmogenic nuclides.

10-Be↗

Application of IDT sensors for structural health monitoring of windmill turbine blades made of composite material

Interdigital transducers (IDT) generate and receive ultrasonic surface waves without the complexity involved with secondary devices such as angled wedges or combs. The IDT sensors have been successfully applied for the NDE of homogeneous materials like metals in order to detect cracks and de-bond. However, these transducers have not been yet adapted for complex and anisotropic materials like fiber-reinforced composites. This work presents the possibility of using IDT sensors for monitoring structural damages in wind turbine blades, typically made of fiberglass composites. IDT sensors with a range of operating frequency between 250 kHz and 1 MHz are initially tested on representative composite test panels for ultrasonic surface wave properties including beam spread, propagation distance and effect of material's anisotropy. Based on these results, an optimum frequency range for the IDT sensor is found to be 250-500 kHz. Subsequently, IDT sensors with operating frequency 500 kHz are used to detect and quantify artificial defects created in the composite test samples. Discussions are made on the interaction of ultrasonic fields with these defects along with the effects of fiber directionality and composite layer stacking.

42 ENGINEERING↗

High strain in polycrystalline Ni{sub 48.8}Mn{sub 31.4}Ga{sub 19.8} Heusler alloys under overlapped static and oscillating magnetic fields

Martensitic polycrystalline Ni{sub 48.8}Mn{sub 31.4}Ga{sub 19.8} Heusler alloys, with a stacking period of 14 atomic planes at room temperature, were innovatively processed by combining high-energy ball milling and powder metallurgy. Bulk samples were mechanically coupled to a piezoelectric material in a parallel configuration, and the mechanical deformation of the studied system due to the twin's variant motion was investigated under overlapped static and oscillating magnetic fields. A reversible and high mechanical deformation is observed when the frequency of the oscillating magnetic field is tuned with the natural vibration frequency of this system. In this condition, a linear deformation as a function of the static magnetic field amplitude occurs in the ±4 kOe range, and a mechanical deformation of 2% at 10 kOe is observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SOUTHERN COSMOLOGY SURVEY. II. MASSIVE OPTICALLY SELECTED CLUSTERS FROM 70 SQUARE DEGREES OF THE SUNYAEV-ZEL'DOVICH EFFECT COMMON SURVEY AREA

We present a catalog of 105 rich and massive (M>3 x 10{sup 14} M {sub sun}) optically selected clusters of galaxies extracted from 70 deg{sup 2} of public archival griz imaging from the Blanco 4 m telescope acquired over 45 nights between 2005 and 2007. We use the clusters' optically derived properties to estimate photometric redshifts, optical luminosities, richness, and masses. We complement the optical measurements with archival XMM-Newton and ROSAT X-ray data which provide additional luminosity and mass constraints on a modest fraction of the cluster sample. Two of our clusters show clear evidence for central lensing arcs; one of these has a spectacular large diameter, nearly complete Einstein Ring surrounding the brightest cluster galaxy. A strong motivation for this study is to identify the massive clusters that are expected to display prominent signals from the Sunyaev-Zel'dovich effect (SZE) and therefore be detected in the wide-area millimeter-band surveys being conducted by both the Atacama Cosmology Telescope and the South Pole Telescope. The optical sample presented here will be useful for verifying new SZE cluster candidates from these surveys, for testing the cluster selection function, and for stacking analyses of the SZE data.

79 ASTRONOMY AND ASTROPHYSICS↗

Effective pair potential for random fcc CoCrFeMnNi alloys

The single-phase equiatomic CoCrFeMnNi alloy is a random solid solution of five elements on the face-centered cubic lattice, whose pure constituents crystallize in very different structures and exhibit diverse magnetic properties. Due to the randomness of the alloy, 80% of nearest neighbor bonds are between unlike elements and thus the details of bonding in pure structures are less important. The elastic moduli of this alloy give rise to small Cauchy pressure C 12 - C 44 , which suggests that the dominant part of bonding may be described by a simple pair potential. We test this hypothesis by developing a long-range Lennard-Jones potential in which the equilibrium crystal structures of pure constituents are taken as reference. The standard mixing rules for regular solutions are then adopted to obtain parameters for bonds between unlike elements in the quinary system. The transferability of this potential to quaternary CoCrFeNi, ternary CoCrNi, and binary FeNi alloys is investigated and the predictions compared with experiments and density functional theory calculations. By sampling over a large number of random configurations, we investigate the effect of compositional randomness on misfit volumes, energies of point defects and stacking faults, and the dislocation friction stresses experienced by moving edge and screw dislocations.

Materials Science↗

EXTREME STAR FORMATION IN THE HOST GALAXIES OF THE FASTEST GROWING SUPERMASSIVE BLACK HOLES AT z = 4.8

We report new Herschel observations of 25 z {approx_equal} 4.8 extremely luminous optically selected active galactic nuclei (AGNs). Five of the sources have extremely large star-forming (SF) luminosities, L{sub SF}, corresponding to SF rates (SFRs) of 2800-5600 M{sub Sun} yr{sup -1} assuming a Salpeter initial mass function. The remaining sources have only upper limits on their SFRs, but stacking their Herschel images results in a mean SFR of 700 {+-} 150 M{sub Sun} yr{sup -1}. The higher SFRs in our sample are comparable to the highest observed values so far at any redshift. Our sample does not contain obscured AGNs, which enables us to investigate several evolutionary scenarios connecting supermassive black holes and SF activity in the early universe. The most probable scenario is that we are witnessing the peak of SF activity in some sources and the beginning of the post-starburst decline in others. We suggest that all 25 sources, which are at their peak AGN activity, are in large mergers. AGN feedback may be responsible for diminishing the SF activity in 20 of them, but is not operating efficiently in 5 others.

79 ASTRONOMY AND ASTROPHYSICS↗

Concentration, temperature, and pH dependence of sunset-yellow aggregates in aqueous solutions: An x-ray investigation

The dye sunset yellow (SY) forms columnar aggregates via {pi}-{pi} stacking in aqueous solutions. These aggregates develop orientational and translational order at elevated concentrations to exhibit the nematic (N) and columnar (C) mesophases. Positional-order correlation lengths of the aggregates in the directions parallel and perpendicular to the stacking direction were measured as functions of temperature, concentration, and ionic content of solutions with synchrotron x-ray scattering in magnetically aligned samples. Average length of aggregates (i.e., the number of SY molecules in an aggregate) grows monotonically with concentration while their effective transverse separation decreases. The scission energy, E, determined from the Arrhenius thermal evolution of the longitudinal correlation length, is found to be 4.3 {+-} 0.3 k{sub B}T and 3.5 {+-} 0.2 k{sub B}T, in the N and C phases, respectively. Temperature and concentration dependence of E suggests that chromonic aggregation is not an isodesmic process. The aggregate length decreases with decreasing pH when HCl is added to the solution.

43 PARTICLE ACCELERATORS↗

Comparison of NMC estimates with trans-stilbene, EJ-309, and He-3 detection systems

Neutron multiplicity counting (NMC) is a technique for the assay of fissile material. In this work, three detection systems are utilized for active interrogation assay of shells of the Rocky Flats shells (highly enriched uranium, 93% 235U) stacked from 13.25-54.92 kg assemblies. The singles ($R_1$) and doubles ($R_2$) rates are calculated with each system to estimate two sample parameters: $M_L$- the leakage multiplication and F - the sample fission rate. The estimated mass, m, is found by dividing F by a constant activity per unit mass. Since we are interrogating HEU, the α ratio of (α; n) to fission neutrons is taken to be zero. The system of equations to calculate these quantities was originally derived. The Neutron Multiplicity 3 He Array Detector (NOMAD) consists of 15 3 He tubes inside polyethylene and is the traditional, capture-based detection system for NMC. The polyethylene moderates incoming neutrons for thermal capture in individual tubes. The low gamma background, discrete capture signals, and high efficiency of the NOMAD are beneficial for NMC. However, the time to slow down neutrons to thermal energies leads to a system die away time on the scale of microseconds. Comparatively, the Rossi-alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAMRODD) and the Organic Scintillator Array (OSCAR) are scatter-based detection systems. RAMRODD consists of 8, 5.08 by 5.08 cm EJ-309 liquid scintillators in 4 pairs, evenly-spaced with 90 degrees separation about the center of each assembly. OSCAR consists of a single array of 12, 5.08 by 5.08 cm trans-stilbene crystals aligned with the center of the assembly. Scatter-based systems detect fast neutrons without any moderation, leading to system die away times on the scale of tens of nanoseconds. This allows much shorter timing gate widths compared to thermal systems, thus increasing counting statistics of true correlated fission events. However, scatter-based systems are susceptible to neutron cross-talk when an incident neutron scatters off one detector and interacts in an adjacent detector, causing two seemingly correlated detection signals. The equations developed adjust for cross-talk to conduct NMC with scatter-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗