Search NASA⌕ Search

SEARCH · Search NASA

Results for “statistical segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Backbone Stitching in Bottlebrush Copolymer Mesodomains and the Impact of Side Chain Crystallization

We synthesized bottlebrush statistical copolymers (BSCPs) having poly­(ethylene oxide) (PEO) and poly­(dimethylsiloxane) (PDMS) side chains attached to a polynorbornene backbone. Small-angle X-ray scattering analysis showed that for densely grafted BSCPs, the scattering length density gradually transitions between the PEO and PDMS domains. For loosely grafted BSCPs, the polymer backbone formed a distinct mesodomain, with a lower electron and mass density than both the PEO and PDMS domains. The bottlebrush backbone essentially “stitches” the PEO and PDMS side chains, looping back and forth from the PEO to PDMS domains with the backbone segments oriented normal to the domain interfaces. Self-consistent field theory (SCFT) calculations validated the stitching of the backbone driven by the microphase separation of PEO and PDMS, along with a strong segmental order of the side chains in the melt. The reduced birefringence upon PEO crystallization suggests the disruption of the strong segmental order by the crystallization. Both the static intrinsic and the form birefringences of the BSCPs decreased upon PEO crystallization. Solid-state NMR confirmed the rigidity of PEO crystallites and the bottlebrush backbone. Self-assembly of BSCPs containing polyhedral oligomeric silsesquioxane (POSS) pendent groups was also evaluated by X-ray scattering, showing the formation of lamellar microdomains that inhibited POSS crystallization.

Hu, Mingqiu↗

Analysis of multispectral data using an unsupervised classification technique: Application to VAS

A statistical classification method based on clustering of multidimensional histograms was applied to several channels of the VAS multispectral imagery. The method automatically discriminates and classifies atmospheric ground features such as cloud types, atmospheric moisture patterns, ocean, or ground. Such a clustering method has the advantage of forming natural data groupings, without a priori classification. Clusters are not limited by straight lines or plane surfaces as is the case in threshold methods. The method was applied to simultaneous full resolution images from channels 8 (11.2 micron), 10 (6.7 micron), and 12 (3.9 micron). Twenty image segments of 64 by 64, 12 image segments of 128 by 128, and 4 image segments of 254 by 254 picture elements were analyzed. In addition, normal VISSR mode images at 1800, 1830, and 2000 GMT were used to identify the classes. The gray levels measured along a scan line and the result of the classification scheme (dashed curves) for the three channels investigated are shown. Each point of the image is affected to a class. Each class is identified by a center of gravity that is represented by a vector in the three dimensional space of gray levels.

Szejwach, G.↗

Review and evaluation of recent developments in melic inlet dynamic flow distortion prediction and computer program documentation and user's manual estimating maximum instantaneous inlet flow distortion from steady-state total pressure measurements with full, limited, or no dynamic data

A review of the Melick method of inlet flow dynamic distortion prediction by statistical means is provided. These developments include the general Melick approach with full dynamic measurements, a limited dynamic measurement approach, and a turbulence modelling approach which requires no dynamic rms pressure fluctuation measurements. These modifications are evaluated by comparing predicted and measured peak instantaneous distortion levels from provisional inlet data sets. A nonlinear mean-line following vortex model is proposed and evaluated as a potential criterion for improving the peak instantaneous distortion map generated from the conventional linear vortex of the Melick method. The model is simplified to a series of linear vortex segments which lay along the mean line. Maps generated with this new approach are compared with conventionally generated maps, as well as measured peak instantaneous maps. Inlet data sets include subsonic, transonic, and supersonic inlets under various flight conditions.

Schweikhard, W. G.↗

Persistence Mapping Using EUV Solar Imager Data

We describe a simple image processing technique that is useful for the visualization and depiction of gradually evolving or intermittent structures in solar physics extreme-ultraviolet imagery. The technique is an application of image segmentation, which we call "Persistence Mapping," to isolate extreme values in a data set, and is particularly useful for the problem of capturing phenomena that are evolving in both space and time. While integration or "time-lapse" imaging uses the full sample (of size N ), Persistence Mapping rejects (N - 1)/N of the data set and identifies the most relevant 1/N values using the following rule: if a pixel reaches an extreme value, it retains that value until that value is exceeded. The simplest examples isolate minima and maxima, but any quantile or statistic can be used. This paper demonstrates how the technique has been used to extract the dynamics in long-term evolution of comet tails, erupting material, and EUV dimming regions.

Thompson, B. J.↗

Study of the Photon Strength Functions for Gadolinium Isotopes with the DANCE Array

The gadolinium isotopes are interesting for reactor applications as well as for medicine and astrophysics. The gadolinium isotopes have some of the largest neutron capture cross sections. As a consequence they are used in the control rod in reactor fuel assembly. From the basic science point of view, there are seven stable isotopes of gadolinium with varying degrees of deformation. Therefore they provide a good testing ground for the study of deformation dependent structure such as the scissors mode. Decay gamma rays following neutron capture on Gd isotopes are detected by the DANCE array, which is located at flight path 14 at the Lujan Neutron Scattering Center at Los Alamos National Laboratory. The high segmentation and close packing of the detector array enable gamma-ray multiplicity measurements. The calorimetric properties of the DANCE array coupled with the neutron time-of-flight technique enables one to gate on a specific resonance of a specific isotope in the time-of-flight spectrum and obtain the summed energy spectrum for that isotope. The singles gamma-ray spectrum for each multiplicity can be separated by their DANCE cluster multiplicity. Various photon strength function models are used for comparison with experimentally measured DANCE data and provide insight for understanding the statistical decay properties of deformed nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PERSISTENCE MAPPING USING EUV SOLAR IMAGER DATA

We describe a simple image processing technique that is useful for the visualization and depiction of gradually evolving or intermittent structures in solar physics extreme-ultraviolet imagery. The technique is an application of image segmentation, which we call “Persistence Mapping,” to isolate extreme values in a data set, and is particularly useful for the problem of capturing phenomena that are evolving in both space and time. While integration or “time-lapse” imaging uses the full sample (of size N ), Persistence Mapping rejects ( N − 1)/ N of the data set and identifies the most relevant 1/ N values using the following rule: if a pixel reaches an extreme value, it retains that value until that value is exceeded. The simplest examples isolate minima and maxima, but any quantile or statistic can be used. This paper demonstrates how the technique has been used to extract the dynamics in long-term evolution of comet tails, erupting material, and EUV dimming regions.

79 ASTRONOMY AND ASTROPHYSICS↗

A COMPREHENSIVE ANALYSIS OF SWIFT/X-RAY TELESCOPE DATA. IV. SINGLE POWER-LAW DECAYING LIGHT CURVES VERSUS CANONICAL LIGHT CURVES AND IMPLICATIONS FOR A UNIFIED ORIGIN OF X-RAYS

By systematically analyzing the Swift/XRT light curves detected before 2009 July, we find 19 light curves that monotonously decay as a single power law (SPL) with an index of 1 approx 1.7 from tens (or hundreds) of seconds to approx10{sup 5} s post the gamma-ray burst (GRB) trigger. They are apparently different from the canonical light curves characterized by a shallow-to-normal decay transition. We compare the observations of the prompt gamma rays and the X-rays for these two samples of GRBs (SPL vs. canonical). No statistical difference is found in the prompt gamma-ray properties for the two samples. The X-ray properties of the two samples are also similar, although the SPL sample tends to have a slightly lower neutral hydrogen absorption column for the host galaxies and a slightly larger energy release compared with the canonical sample. The SPL X-ray Telescope (XRT) light curves in the burst frame gradually merge into a conflux, and their luminosities at 10{sup 5} s are normally distributed at log L/ergs s{sup -1} = 45.6 +- 0.5. The normal decay segment of the canonical XRT light curves has the same feature. Similar to the normal decay segment, the SPL light curves satisfy the closure relations and therefore can be roughly explained with external shock models. In the scenario that the X-rays are the afterglows of the GRB fireball, our results indicate that the shallow decay would be due to energy injection into the fireball and the total energy budget after injection for both samples of GRBs is comparable. More intriguing, we find that a prior X-ray emission model proposed by Yamazaki is more straightforward to interpret the observed XRT data. We show that the zero times (T {sub 0}) of the X-rays are 10{sup 2}-10{sup 5} s prior to the GRB trigger for the canonical sample, and satisfy a log-normal distribution. The negligible T {sub 0}'s of the SPL sample are consistent with being the tail of T {sub 0} distributions at low end, suggesting that the SPL sample and the canonical sample may be from a same parent sample. Referenced to T {sub 0}, the canonical XRT light curves well trace the SPL light curves. The T {sub 0}'s of the canonical light curves in our analysis are usually much larger than the offsets of the known precursors from the main GRBs. If the prior emission hypothesis is real, the X-ray emission is better interpreted within the external shock models based on the spectral and temporal indices of the X-rays. The lack of detection of a jet-like break in most XRT light curves implies that the opening angle of the prior emission jet would be usually large.

79 ASTRONOMY AND ASTROPHYSICS↗

Automated segmentation of soft X-ray tomography: Native cellular structure with submicron resolution at high-throughput for whole-cell quantitative imaging in yeast

Soft X-ray tomography (SXT) is an invaluable tool for quantitatively analyzing cellular structures at suboptical isotropic resolution. However, it has traditionally depended on manual segmentation, limiting its scalability for large datasets. Here, we leverage a deep learning-based autosegmentation pipeline to segment and label cellular structures in hundreds of cells across three Saccharomyces cerevisiae strains. This task-based pipeline uses manual iterative refinement to improve segmentation accuracy for key structures, including the cell body, nucleus, vacuole, and lipid droplets, enabling high-throughput and precise phenotypic analysis. Using this approach, we quantitatively compared the three-dimensional (3D) whole-cell morphometric characteristics of wild-type, VPH1-GFP, and vac14 strains, uncovering detailed strain-specific cell and organelle size and shape variations. We show the utility of SXT data for precise 3D curvature analysis of entire organelles and cells and detection of fine morphological features using surface meshes. Our approach facilitates comparative analyses with high spatial precision and statistical throughput, uncovering subtle morphological features at the single-cell and population level. This workflow significantly enhances our ability to characterize cell anatomy and supports scalable studies on the mesoscale, with applications in investigating cellular architecture, organelle biology, and genetic research across diverse biological contexts.

Chen, Jianhua [Lawrence Berkeley National Laborato↗

A statistical mechanics framework for polymer chain scission, based on the concepts of distorted bond potential and asymptotic matching

To design increasingly tough, resilient, and fatigue-resistant elastomers and hydrogels, the relationship between controllable network parameters at the molecular level (bond type, non-uniform chain length, entanglement density, etc.) to macroscopic quantities that govern damage and failure must be established. Many of the most successful constitutive models for elastomers have been rooted in statistical mechanical treatments of polymer chains. Typically, such constitutive models have used variants of the freely jointed chain model with rigid links. However, since the free energy state of a polymer chain is dominated by enthalpic bond distortion effects as the chain approaches its rupture point, bond extensibility ought to be accounted for if the model is intended to capture chain rupture. To that end, a new bond potential is supplemented to the freely jointed chain model (as derived in the u FJC framework of Buche and Silberstein (2021) and Buche et al. (2022)), which we have extended to yield a tractable, closed-form model of single chain behavior that should be amenable to continuum-level constitutive model development. Inspired by the asymptotically matched u FJC model response in both the low/intermediate chain force and high chain force regimes, a simple, quasi-polynomial bond potential energy function is derived. This bond potential exhibits harmonic behavior near the equilibrium state and anharmonic behavior for large bond stretches tending to a characteristic energy plateau (akin to the Lennard-Jones and Morse bond potentials). Using this bond potential, approximate yet highly-accurate analytical functions for bond stretch and chain force dependent upon chain stretch are established. Then, using this polymer chain model, a stochastic thermal fluctuation-driven chain rupture framework is developed. This framework is based upon a force-modified tilted bond potential that accounts for distortional bond potential energy, allowing for the derivation and subsequent calculation of the dissipated chain scission energy. Here, the cases of rate-dependent and rate-independent scission are accounted for throughout the rupture framework. The impact of Kuhn segment number on chain rupture behavior is also investigated. The model is fit to single chain mechanical response data collected from atomic force microscopy tensile tests for validation and to glean deeper insight into the molecular physics taking place. Due to their analytical nature, this polymer chain model and the associated rupture framework can in the future be implemented in finite element models accounting for fracture and fatigue in polydisperse elastomer networks.

36 MATERIALS SCIENCE↗

TU-A-12A-07: CT-Based Biomarkers to Characterize Lung Lesion: Effects of CT Dose, Slice Thickness and Reconstruction Algorithm Based Upon a Phantom Study

Purpose: Radiogenomics promises the ability to study cancer tumor genotype from the phenotype obtained through radiographic imaging. However, little attention has been paid to the sensitivity of image features, the image-based biomarkers, to imaging acquisition techniques. This study explores the impact of CT dose, slice thickness and reconstruction algorithm on measuring image features using a thorax phantom. Methods: Twentyfour phantom lesions of known volume (1 and 2mm), shape (spherical, elliptical, lobular and spicular) and density (-630, -10 and +100 HU) were scanned on a GE VCT at four doses (25, 50, 100, and 200 mAs). For each scan, six image series were reconstructed at three slice thicknesses of 5, 2.5 and 1.25mm with continuous intervals, using the lung and standard reconstruction algorithms. The lesions were segmented with an in-house 3D algorithm. Fifty (50) image features representing lesion size, shape, edge, and density distribution/texture were computed. Regression method was employed to analyze the effect of CT dose, slice of thickness and reconstruction algorithm on these features adjusting 3 confounding factors (size, density and shape of phantom lesions). Results: The coefficients of CT dose, slice thickness and reconstruction algorithm are presented in Table 1 in the supplementary material. No significant difference was found between the image features calculated on low dose CT scans (25mAs and 50mAs). About 50% texture features were found statistically different between low doses and high doses (100 and 200mAs). Significant differences were found for almost all features when calculated on 1.25mm, 2.5mm, and 5mm slice thickness images. Reconstruction algorithms significantly affected all density-based image features, but not morphological features. Conclusions: There is a great need to standardize the CT imaging protocols for radiogenomics study because CT dose, slice thickness and reconstruction algorithm impact quantitative image features to various degrees as our study has shown.

60 APPLIED LIFE SCIENCES↗

Statistical Performance of Forced Oscillation Detectors in the Presence of Missing Measurements

In bulk power systems, measurement-based monitoring for large oscillations can help maintain system reliability. One of the challenges encountered in a recent field demonstration was the unavailability of measurements due to underlying measurement quality or communication problems. During the demonstration, the oscillation detector ignored a measurement location if even 10 seconds of data was missing. To extend the detector's ability to operate in these conditions, this paper evaluates the impact of three methods for addressing missing data. The strengths and weaknesses of each approach are evaluated using theoretical expressions for the probability of detection along with results from simulated data and publicly available field measurements. Based on these results, a suitable approach is identified that can extend the oscillation detector's performance when large segments of data are missing.

Follum, James D.↗

Exploring the Nature of Neutrinos with the Deep Underground Neutrino Experiment (DUNE)

The Deep Underground Neutrino Experiment (DUNE) is a next-generation experimental program designed to study the behaviour of neutrino oscillation. DUNE will utilize a neutrino beam originating at Fermilab, near Chicago, and will leverage a detector at Fermilab (Near Detector) and a detector 1300 km away in South Dakota (Far Detector), south of Saskatchewan. In the first phase of DUNE, its Far Detector will comprise of two 10,000 ton (fiducial) liquid argon (LAr) time-projection chamber (TPC) modules – powerful tracking calorimeter detectors – placed nearly a mile underground. With this large, sensitive, underground detector, DUNE aims to collect a high statistics and pure sample of neutrinos at the Far Detector. This setup also offers the potential to study non-beam physical processes via e.g. neutrinos produced in the atmosphere, supernova neutrino bursts, and/or solar neutrinos, etc. A second phase will aim to add more detector mass and expand the program. The Near Detector will consist of a LAr TPC module as well: critical to constraining systematic uncertainties in the oscillation analysis. However, this LAr TPC will have a novel design using a pixel-based readout instead of the traditional wire-based readout. This and the segmentation of the LAr TPC into multiple units are crucial in mitigating the high multiplicity of neutrino interactions expected in any readout window given its proximity to the beam. The Near Detector will feature additional components and capability beyond the LAr TPC, allowing one to deeply characterize the neutrino flux. Due to the complexity of this experimental program, several smaller-scale prototype detectors have been operating to test, validate, and improve both the technical designs and software for processing and analyzing events. By operating in charged particle test beams or neutrino beams, several of the prototypes are also capable of producing valuable results. Canadian institutions are involved in the realization of the DUNE through efforts with both the Near and Far Detectors and prototypes. DUNE is anticipated to begin operating near the end of this decade/the beginning of the next. This talk will focus on the overall DUNE program, for example its ultimate plans, status, and the efforts with prototypes.

Howard, Bruce [York U., Canada; Fermilab]↗

Measuring the Muon Neutrino Magnetic Moment in the NOvA Near Detector

Measuring an enhanced neutrino magnetic moment would be a clear indication of physics beyond the Standard Model, shedding light on the correct beyond Standard Model theory or the potential Majorana nature of neutrinos. It would manifest in the NOvA near detector as an excess of neutrino-on-electron elastic scattering interactions at low electron recoil energies. Leveraging an intense and highly pure muon neutrino beam, along with a finely segmented liquid scintillator detector technology specifically designed for electromagnetic shower separation, enables NOvA to achieve a potentially world-leading sensitivity in probing the effective muon neutrino magnetic moment. This analysis, based on neutrino data collected between 2014 and 2021, corresponding to an exposure of $13.8\times10^{20}$ protons-on-target, yields a result consistent with the Standard Model-only hypothesis with a p-value of 0.31. An upper limit on the effective muon neutrino magnetic moment is set at $\mu_{\nu_\mu}<19.1\times 10^{-10}\mu_B$ at $90\%$ confidence level. Despite facing statistical limitations stemming from low cross section of the signal process, systematic uncertainties have a significant impact on this result. To address these challenges, the NOvA Test Beam experiment focuses on mitigating some of the largest systematic uncertainties within NOvA by investigating particle interactions and energy deposition in a small-scale replica NOvA detector. This thesis describes the calibration of the NOvA Test Beam detector, which is a crucial step in analysing the Test Beam data before they can be utilised to reduce NOvA systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A dual model HU conversion from MRI intensity values within and outside of bone segment for MRI-based radiotherapy treatment planning of prostate cancer

Purpose: The lack of electron density information in magnetic resonance images (MRI) poses a major challenge for MRI-based radiotherapy treatment planning (RTP). In this study the authors convert MRI intensity values into Hounsfield units (HUs) in the male pelvis and thus enable accurate MRI-based RTP for prostate cancer patients with varying tissue anatomy and body fat contents. Methods: T{sub 1}/T{sub 2}*-weighted MRI intensity values and standard computed tomography (CT) image HUs in the male pelvis were analyzed using image data of 10 prostate cancer patients. The collected data were utilized to generate a dual model HU conversion technique from MRI intensity values of the single image set separately within and outside of contoured pelvic bones. Within the bone segment local MRI intensity values were converted to HUs by applying a second-order polynomial model. This model was tuned for each patient by two patient-specific adjustments: MR signal normalization to correct shifts in absolute intensity level and application of a cutoff value to accurately represent low density bony tissue HUs. For soft tissues, such as fat and muscle, located outside of the bone contours, a threshold-based segmentation method without requirements for any patient-specific adjustments was introduced to convert MRI intensity values into HUs. The dual model HU conversion technique was implemented by constructing pseudo-CT images for 10 other prostate cancer patients. The feasibility of these images for RTP was evaluated by comparing HUs in the generated pseudo-CT images with those in standard CT images, and by determining deviations in MRI-based dose distributions compared to those in CT images with 7-field intensity modulated radiation therapy (IMRT) with the anisotropic analytical algorithm and 360° volumetric-modulated arc therapy (VMAT) with the Voxel Monte Carlo algorithm. Results: The average HU differences between the constructed pseudo-CT images and standard CT images of each test patient ranged from −2 to 5 HUs and from 22 to 78 HUs in soft and bony tissues, respectively. The average local absolute value differences were 11 HUs in soft tissues and 99 HUs in bones. The planning target volume doses (volumes 95%, 50%, 5%) in the pseudo-CT images were within 0.8% compared to those in CT images in all of the 20 treatment plans. The average deviation was 0.3%. With all the test patients over 94% (IMRT) and 92% (VMAT) of dose points within body (lower than 10% of maximum dose suppressed) passed the 1 mm and 1% 2D gamma index criterion. The statistical tests (t- and F-tests) showed significantly improved (p ≤ 0.05) HU and dose calculation accuracies with the soft tissue conversion method instead of homogeneous representation of these tissues in MRI-based RTP images. Conclusions: This study indicates that it is possible to construct high quality pseudo-CT images by converting the intensity values of a single MRI series into HUs in the male pelvis, and to use these images for accurate MRI-based prostate RTP dose calculations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling the target dose fall-off in IMRT and VMAT planning techniques for cervical SBRT

There has been growing interest in the use of stereotactic body radiotherapy (SBRT) technique for the treatment of cervical cancer. The purpose of this study was to characterize dose distributions as well as model the target dose fall-off for intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) delivery techniques using 6 and 10 MV photon beam energies. Fifteen (n = 15) patients with non-bulky cervical tumors were planned in Pinnacle{sup 3} with a Varian Novalis Tx (HD120 MLC) using 6 and 10 MV photons with the following techniques: (1) IMRT with 10 non-coplanar beams (2) dual, coplanar 358° VMAT arcs (4° spacing), and (3) triple, non-coplanar VMAT arcs. Treatment volumes and dose prescriptions were segmented according to University of Texas Southwestern (UTSW) Phase II study. All plans were normalized such that 98% of the planning target volume (PTV) received 28 Gy (4 fractions). For the PTV, the following metrics were evaluated: homogeneity index, conformity index, D{sub 2cc}, D{sub mean}, D{sub max}, and dose fall-off parameters. For the organs at risk (OARs), D{sub 2cc}, D{sub 15cc}, D{sub 0.01cc}, V{sub 20}, V{sub 40}, V{sub 50}, V{sub 60}, and V{sub 80} were evaluated for the bladder, bowel, femoral heads, rectum, and sigmoid. Statistical differences were evaluated using a Friedman test with a significance level of 0.05. To model dose fall-off, expanding 2-mm-thick concentric rings were created around the PTV, and doses were recorded. Statistically significant differences (p 3-arc , as compared with IMRT. VMAT{sub 3-arc} improved the bladder V{sub 40}, V{sub 50}, and V{sub 60}, and the bowel V{sub 20} and V{sub 50}. All fitted regressions had an R{sup 2} ≥ 0.98. For cervical SBRT plans, a VMAT{sub 3-arc} approach offers a steeper dose fall-off outside of the target volume. Faster dose fall-off was observed in smaller targets as opposed to medium and large targets, denoting that OAR sparing is dependent on target size. These improvements are further pronounced with the use of 10-MV photons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PHYSICAL PROPERTIES OF LARGE AND SMALL GRANULES IN SOLAR QUIET REGIONS

The normal mode observations of seven quiet regions obtained by the Hinode spacecraft are analyzed to study the physical properties of granules. An artificial intelligence technique is introduced to automatically find the spatial distribution of granules in feature spaces. In this work, we investigate the dependence of granular continuum intensity, mean Doppler velocity, and magnetic fields on granular diameter. We recognized 71,538 granules by an automatic segmentation technique and then extracted five properties: diameter, continuum intensity, Doppler velocity, and longitudinal and transverse magnetic flux density to describe the granules. To automatically explore the intrinsic structures of the granules in the five-dimensional parameter space, the X-means clustering algorithm and one-rule classifier are introduced to define the rules for classifying the granules. It is found that diameter is a dominating parameter in classifying the granules and two families of granules are derived: small granules with diameters smaller than 1.''44, and large granules with diameters larger than 1.''44. Based on statistical analysis of the detected granules, the following results are derived: (1) the averages of diameter, continuum intensity, and Doppler velocity in the upward direction of large granules are larger than those of small granules; (2) the averages of absolute longitudinal, transverse, and unsigned flux density of large granules are smaller than those of small granules; (3) for small granules, the average of continuum intensity increases with their diameters, while the averages of Doppler velocity, transverse, absolute longitudinal, and unsigned magnetic flux density decrease with their diameters. However, the mean properties of large granules are stable; (4) the intensity distributions of all granules and small granules do not satisfy Gaussian distribution, while that of large granules almost agrees with normal distribution with a peak at 1.04 I{sub 0}.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-263: Repeatability of SUV and Texture Parameters in Serial PET Studies

Purpose: Standardized uptake values (SUV) are standard quantitative PET measures of FDG tumor uptake used,and are used as a tool to monitor response to therapy. Textural analysis is emerging as a new tool for assessing intratumoral heterogeneity which may allow better tissue characterization and improved prediction of response and survival rate.Understanding what variations may be expected in these parameters is key in order to make decisions based on how the change throughout the course of treatment. The aim of this study was to assess repeatability in SUV measures and texture parameters,and establish criteria that differentiate changes associated with treatment rather than statistical variability. Methods: Eighty patients,167 random lesions total,were scanned in a GE Discovery STE PET/CT Scanner. One field-of-view was chosen centered on the largest lesion observed in a clinical whole-body FDG PET.Immediately following,a gated 9 min scan was acquired in list mode,without changing the patient’s position between any scans. Data was replayed into 3 time bins,3 min each,in order to insure equivalent noise characteristics in each replicate.Data was reconstructed into 128×128×47 square matrices.One VOI was drawn over each lesion for each patient and used to segment all 3 replicates. The mean.max and peak SUV were calculated for each VOI and replicate. First-order textural features were also calculated (skewness and kurtosis). Repeatability was calculated as the average standard deviation over the mean for the 3 repeated measurements for each lesion. Results: The average percent error in the SUV max,peak and mean were 3.4%(0– 12.9%),1.9% (0–7.5%),2.8% (0–12.2%),respectively.For skewness and kurtosis they were 10.9% and 17.8%. Conclusion: We have shown that there is a large variation in %error in SUV measures across patients. SUVpeak is the least variable and kurtosis and skewness parameters are less reliable thatn SUVs.Higher order textures are be.

60 APPLIED LIFE SCIENCES↗

A full-spectral Bayesian reconstruction approach based on the material decomposition model applied in dual-energy computed tomography

Purpose: Dual-energy computed tomography (DECT) makes it possible to get two fractions of basis materials without segmentation. One is the soft-tissue equivalent water fraction and the other is the hard-matter equivalent bone fraction. Practical DECT measurements are usually obtained with polychromatic x-ray beams. Existing reconstruction approaches based on linear forward models without counting the beam polychromaticity fail to estimate the correct decomposition fractions and result in beam-hardening artifacts (BHA). The existing BHA correction approaches either need to refer to calibration measurements or suffer from the noise amplification caused by the negative-log preprocessing and the ill-conditioned water and bone separation problem. To overcome these problems, statistical DECT reconstruction approaches based on nonlinear forward models counting the beam polychromaticity show great potential for giving accurate fraction images.Methods: This work proposes a full-spectral Bayesian reconstruction approach which allows the reconstruction of high quality fraction images from ordinary polychromatic measurements. This approach is based on a Gaussian noise model with unknown variance assigned directly to the projections without taking negative-log. Referring to Bayesian inferences, the decomposition fractions and observation variance are estimated by using the joint maximum a posteriori (MAP) estimation method. Subject to an adaptive prior model assigned to the variance, the joint estimation problem is then simplified into a single estimation problem. It transforms the joint MAP estimation problem into a minimization problem with a nonquadratic cost function. To solve it, the use of a monotone conjugate gradient algorithm with suboptimal descent steps is proposed.Results: The performance of the proposed approach is analyzed with both simulated and experimental data. The results show that the proposed Bayesian approach is robust to noise and materials. It is also necessary to have the accurate spectrum information about the source-detector system. When dealing with experimental data, the spectrum can be predicted by a Monte Carlo simulator. For the materials between water and bone, less than 5% separation errors are observed on the estimated decomposition fractions.Conclusions: The proposed approach is a statistical reconstruction approach based on a nonlinear forward model counting the full beam polychromaticity and applied directly to the projections without taking negative-log. Compared to the approaches based on linear forward models and the BHA correction approaches, it has advantages in noise robustness and reconstruction accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗