Physically-based strength model of tantalum incorporating effects of temperature, strain rate and pressure

In this work, we develop a tantalum strength model that incorporates e ects of temperature, strain rate and pressure. Dislocation kink-pair theory is used to incorporate temperature and strain rate e ects while the pressure dependent yield is obtained through the pressure dependent shear modulus. Material constants used in the model are parameterized from tantalum single crystal tests and polycrystalline ramp compression experiments. It is shown that the proposed strength model agrees well with the temperature and strain rate dependent yield obtained from polycrystalline tantalum experiments. Furthermore, the model accurately reproduces the pressure dependent yield stresses up to 250 GPa. The proposed strength model is then used to conduct simulations of a Taylor cylinder impact test and validated with experiments. This approach provides a physically-based multi-scale strength model that is able to predict the plastic deformation of polycrystalline tantalum through a wide range of temperature, strain and pressure regimes.

36 MATERIALS SCIENCE↗

The effect of shear strain and shear localization on fault healing

The seismic cycle of repeated earthquake failure requires that faults regain frictional strength during the interseismic phase, when the fault is locked or undergoing quasi-static creep. Fault healing plays a central role in determining earthquake stress drop, recurrence interval, elastic radiation frequency and other source parameters. In particular, the longer a fault remains quasi-stationary, the stronger it becomes and the larger the potential stress drop can be for the next event. Here, we address the role of shear strain and strain localization on fault healing and healing rate. We performed slide-hold-slide friction experiments on quartz gouge in the double-direct shear configuration for shear strain up to 25 and hold times from 10 to 1000 s. The results show that both healing and healing rate increase nonlinearly with increasing shear strain. Frictional healing scales with volumetric strain within the laboratory fault zone. Using the volumetric strain upon reshear as a proxy for strain localization, we demonstrate that the capacity of a fault to heal is directly proportional to shear bandwidth and degree of strain localization. The more the deformation is localized, the higher are the healing and healing rate, and thus, the fault strength. Our data provide a framework for understanding variations in fault strength over the seismic cycle and the role of brecciation and strain localization on spatiotemporal variations in fault strength.

58 GEOSCIENCES↗

The effect of elastic strain on the dispersion characteristics of a polariton 2D structure

The dispersion characteristics of a two-dimensional lattice of tunnel-coupled micropores containing single-level quantum dots are numerically simulated. It is shown that, as a result of elastic strain of the system under study, it is possible to achieve necessary changes in its energy structure and optical properties determined by the rearrangement of the polariton spectrum.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Genome sequence of Ensifer medicae strain WSM1369; an effective microsymbiont of the annual legume Medicago sphaerocarpos

Ensifer medicae WSM1369 is an aerobic, motile, Gram-negative, non-spore-forming rod that can exist as a soil saprophyte or as a legume microsymbiont of Medicago. WSM1369 was isolated in 1993 from a nodule recovered from the roots of Medicago sphaerocarpos growing at San Pietro di Rudas, near Aggius in Sardinia (Italy). WSM1369 is an effective microsymbiont of the annual forage legumes M. polymorpha and M. sphaerocarpos. Here we describe the features of E. medicae WSM1369, together with genome sequence information and its annotation. The 6,402,557 bp standard draft genome is arranged into 307 scaffolds of 307 contigs containing 6,656 protein-coding genes and 79 RNA-only encoding genes. This rhizobial genome is one of 100 sequenced as part of the DOE Joint Genome Institute 2010 Genomic Encyclopedia for Bacteria and Archaea-Root Nodule Bacteria (GEBARNB) project.

59 BASIC BIOLOGICAL SCIENCES↗

Fractographic evaluation of creep effects on strain-controlled fatigue-cracking of AISI 304LC and 316 stainless steel

Analysis of high temperature low cycle fatigue of AISI 304LC and 316 stainless steels by the method of strainrange partitioning results in four separate strainrange versus life relationships, depending upon the way in which creep-strain and plastic strain are combined within a cycle. Fractography is used in this investigation of the creep-fatigue interaction associated with these cycles. The PP and PC-cycle fractures were transgranular. The PC-cycle resulted in fewer cycles of initiation and shorter total cyclic life for the same applied inelastic strainrange. The CC-cycle had mixed transgranular and intergranular fracture, fewer cycles of initiation and shorter cycle life than PP or PC. The CP-cycle had fully integranular cracking, and failed in fewer cycles than were required for cracks to initate for PP,PC, and CC.

Oldrieve, R. E.↗

A study of the effect of apparent strain on thermal stress measurement for two types of elevated temperature strain gages

A weldable type strain gage was used to measure low level thermal stress in an elevated temperature environment. Foil strain gages used in a comparative manner reveal that the apparent strain of weldable strain gages is not sufficiently known to acquire accurate low level thermal stress data. Apparent strain data acquired from coupon tests reveals a large scatter in apparent strain characteristics among the weldable strain gages. It is concluded that apparent strain data for individual weldable strain gages must be required prior to installation if valid thermal stress data is to be obtained through the temperature range of room temperature to 755 K (900 F).

Jenkins, J. M.↗

High strain rate properties of angle-ply composite laminates, part 3

Angle-ply graphite/epoxy and graphite/S-glass/epoxy laminates were characterized in uniaxial tension at strain rates ranging from quasi-static to over 500 s(sup -1). Laminate ring specimens of +/-15(sub 2s), +/-22.5(sub 2s), +/-30(sub 2s), +/-45(sub 2s), +/-60(sub 2s), +/-67.5(sub 2s), and +/-75(sub 2s) degree layups were loaded under internal pressure. Results were presented in the form of stress-strain curves to failure. Properties determined included moduli, Poisson's ratios, strength, and ultimate strain. In all seven laminates for the two materials tested the modulus and strength increase with strain rate. The effect of strain rate varies with layup, being lowest for the fiber dominated +/-15(sub 2s) degree laminates and highest for the matrix dominated +/-75(sub 2s) degree laminates. The highest increments over the static values are 10 to 25 percent for the +/-15(sub 2s) degree layup and 200 to 275 percent for the +/-75(sub 2s) degree layup. Ultimate strains do not show any significant trends with strain rate. In almost all cases the ultimate strain values are within +/-20 percent of the mean value and in half of the cases the deviation from the mean are less than 10 percent.

Daniel, I. M.↗

Temperature effects on high strain rate properties of graphite/epoxy composites

A unidirectional graphite epoxy material (AS4/3501-6) was characterized at strain rates ranging from 5 x 10(exp 6) s(exp -1) to 5(exp -1), at room temperature and at 128 C. Results are presented in the form of stress-strain curves to failure. The longitudinal properties remain nearly unchanged with strain rate and temperature. The transverse modulus increases with strain rate but decreases with temperature. The transverse strength and transverse ultimate tensile strain have a positive rate sensitivity at low rates, which changes to negative at intermediate rates and returns to positive rate sensitivity at the highest rates tested. A temperature-time equivalence principle was applied and master curves were obtained for the transverse mechanical properties. The in-plane shear modulus and in-plane shear strength have a positive rate sensitivity. The ultimate intralaminar shear strain has a positive rate sensitivity at low rates, which changes to negative at high rates. At the elevated temperature of 128 C, the ultimate shear strain is 25 to 30 percent higher than the room temperature value, but its strain rate dependence is moderate.

Yaniv, G.↗

Analysis of the Effects of Residual Strains and Defects on Skin/Stiffener Debonding using Decohesion Elements

Delamination is one of the predominant forms of failure in laminated composites especially when there is no reinforcement in the thickness direction. To develop composite structures that are more damage tolerant, it is necessary to understand how delamination develops and how it can affect the residual performance. A number of factors such as residual thermal strains, matrix curing shrinkage, and manufacturing defects affect how damage will grow in a composite structure. It is important to develop analysis methods that are computationally efficient that can account for all such factors. The objective of the current work is to apply a newly developed decohesion element to investigate the debond strength of skin/stiffener composite specimens. The process of initiation of delaminations and the propagation of delamination fronts is investigated. The numerical predictions are compared with published experimental results.

Davila, Carlos G.↗