Search NASA⌕ Search

SEARCH · Search NASA

Results for “system flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Scientific and Technical Assistance for the Deployment of a Flexible Airborne Spectrometer System During C-MAPExp and COMEX: COMEX Version - 1.9T

The COMEX (CO2 and MEthane eXperiment) campaign supports the mission definition of CarbonSat and HyspIRI (Hyperspectral Infrared Imager) by providing representative airborne remote sensing data ‐ MAMAP (Methane Airborne MAPper) for CarbonSat; the Airborne Visual InfraRed Imaging Spectrometer (Classic & Next Generation) AVIRIS‐C/AVIRIS‐NG for HyspIRI ‐ as well as ground-based and airborne in‐situ data. The objectives of the COMEX campaign activities are (see Campaign Implementation Plan (RD‐4)): 1. Investigate spatial/spectral resolution trade‐offs for CH4 anomaly detection and flux inversion by comparison of MAMAP‐derived emission estimates with AVIRIS/AVIRIS‐NG derived data. 2. Evaluate sun‐glint observation geometry on CH4 retrievals for marine sources. 3. Characterize the effect of Surface Spectral Reflectance (SSR) heterogeneity on trace gas retrievals of CO2 and CH4 for medium and low‐resolution spectrometry. 4. Identify benefits from joint SWIR/TIR (ShortWave InfraRed/Thermal InfraRed ) data for trace gas detection and retrieval by comparison of MAMAP and AVIRIS/AVIRIS‐NG NIR/SWIR data with MAKO (Aerospace Corp.)TIR data. The ability to derive emission source strength for a range of strong emitting targets by remote sensing will be evaluated from combined AVIRIS‐NG and MAMAP data, adding significant value to the HyspIRI campaign AVIRIS‐NG dataset. The data will be used to quantify anomalies in atmospheric CO2 and CH4 from strong local greenhouse gas sources e.g. localized industrial complexes, landfills, etc. and to derive CO2 and CH4 emissions estimates from atmospheric gradient measurements. The original campaign concept was developed by University of Bremen and BRI. The COMEX campaign is funded bilaterally by NASA and ESA (European Space Agency). Whereas NASA funds the US part of the project via a contract with Dr. Ira Leifer, BRI (Bubbleology Research International), the contribution of MAMAP to the COMEX campaign is funded by ESA within the COMEX‐E project and NASA with respect to a 50 percent contribution to the flight-related costs of flying MAMAP on a US aircraft. The Data Acquisition Report (RD‐9) describes the instrumentation used, the measurements made by the team during the COMEX campaign in May/June 2014 and August/September 2014 in California, and an initial assessment of the data quality.

Point Sources↗

Probabilistic Risk Analysis and Margin Process for a Flexible Thermal Protection System

Atmospheric entry vehicle thermal protection systems are margined due to the uncertainties that exist in entry aeroheating environments and the thermal response of the materials and structures. Entry vehicle thermal protections systems are traditionally over-margined for the heat loads that are experienced along the entry trajectory by designing to survive stacked worst-case scenarios. Additionally, the conventional heat shield design and margin process offers very little insight into the risk of over-temperature during flight and the corresponding reliability of the heat shield performance. A probabilistic margin process can be used to appropriately margin the thermal protection system based on rigorously calculated risk of failure. This probabilistic margin process allows engineers to make informed aeroshell design, entry-trajectory design, and risk trades while preventing excessive margin from being applied. This study presents the methods of the probabilistic margin process and how the uncertainty analysis is used to determine the reliability of the entry vehicle thermal protection system and associated risks of failure.

Tobin, Steven A.↗

A Comprehensive Solution for Managing TRU and LLW From Generation to Final Disposition - 13205

A LANL multi-disciplinary team faced the challenge of building and delivering a waste information system capable of managing radioactive, hazardous, and industrial waste from cradle to grave. The result is the Waste Compliance and Tracking System (WCATS) a flexible, adaptive system that has allowed LANL to consolidate its legacy applications into one system, and leverage the advantages of managing all waste types within a single scalable enterprise application. Key functionality required for robust waste operations, include: waste characterization, waste identification, transportation, inventory management, waste processing, and disposal. In order to maintain data quality, field operations such as waste identification, surveillance checklists, wall-to-wall inventory assessments, waste transfers, shipment pickup and receipt, and simple consolidation operations are captured by the operator or technician using mobile computers. Work flow is managed via end-user defined work paths, to ensure that unit operations are performed in the correct order. Regulatory compliance reports and algorithms are provided to support typical U.S. EPA, DOT, NRC, and DOE requirements, including the EPA hazardous waste manifest, NRC LLW manifest, DOE nuclear material at risk, RCRA TSDF inventory rules, and so forth. The WCATS application has allowed LANL to migrate and consolidate its disparate legacy applications. The design and implementation is generalized so that facility owners can customize the user interface, setup facilities and unit operations (i.e., treatment, storage, disposal, characterization, and administrative), define inventory compliance rules, and establish custom work flow requirements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Synergistic heat pumped thermal storage and flexible carbon capture system

A power plant system is disclosed. The power plant system includes a combustor configured, a turbine configured to generate electricity, a heat exchanger and a steam turbine, a carbon capture system configured to remove at least a portion of carbon-based gasses from the flue gas downstream from the heat recovery steam generator, and a thermal storage system including a hot storage unit configured to store thermal energy at a hot temperature, the hot temperature greater than ambient temperature. The power plant is configured to operate in at least a first mode for storing thermal energy in the thermal storage system and a second mode for releasing the stored thermal energy from the thermal storage system and during the second mode, heat stored in the hot storage unit is transferred to the carbon capture system.

Bandhauer, Todd M.↗

Building and grid system benefits of demand flexibility and energy efficiency

The global electricity system is undergoing a dramatic transformation. Technology advancements in clean energy generation (e.g., solar photovoltaics and wind) and electrified demand (e.g., transportation and building heating) are providing a cost-competitive pathway to mitigate the urgent and severe consequences associated with a changing climate. In addition, as extreme events continue to increase in frequency and magnitude, solutions are needed for adapting to the current climate. Through energy efficiency and demand flexibility, buildings play a prominent role in meeting these challenges; recently in Joule, a paper by Langevin et al. provides clear insight into the magnitude of buildings’ technical potential.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fused Silica Surface Coating for a Flexible Silica Mat Insulation System

Fused silica insulation coatings have been developed for application to a flexible mat insulation system. Based on crystalline phase nucleation and growth kinetics, a 99+% SiO2 glass was selected as the base composition. A coating was developed that incorporated the high emissivity phase NiCr2O4 as a two phase coating with goals of high emittance and minimum change in thermal expansion. A second major coating classification has a plasma sprayed emittance coating over a sealed pure amorphous SiO2 layer. A third area of development centered on extremely thin amorphous SiO2 coatings deposited by chemical vapor deposition. The coating characterization studies presented are mechanical testing of thin specimens extracted from the coatings, cyclic arc exposures, and emittance measurements before and after arc exposures.

Rhodes, W. H.↗

On the Path to SunShot. Emerging Issues and Challenges in Integrating High Levels of Solar into the Electrical Generation and Transmission System

This report examines how the bulk power system may need to evolve to accommodate the increased photovoltaic (PV) penetration resulting from achievement of the U.S. Department of Energy's SunShot cost targets. The variable and uncertain nature of PV-generated electricity presents grid-integration challenges. For example, the changing net load associated with high midday PV generation and low electricity demand can create 'overgeneration' that requires curtailment of PV output and reduces PV's value and cost-competitiveness. Accommodating the changes in net load resulting from increased variable generation requires enhancements to a power system's 'flexibility,' or ability to balance supply and demand over multiple time scales through options including changes in system operation, flexible generation, reserves from solar, demand response, energy storage, and enhanced transmission and regional coordination. For utility-scale PV with a baseline SunShot levelized cost of electricity (LCOE) of 6 cents/kWh, increasing the annual energy demand met by solar energy from 10% to 20% would increase the marginal LCOE of PV from 6 cents/kWh to almost 11 cents/kWh in a California grid system with limited flexibility. However, increasing system flexibility could minimize solar curtailment and keep PV cost-competitive at penetrations at least as high as 25%. In the longer term, energy storage technologies--such as concentrating solar power with thermal energy storage--could facilitate the cost-effective integration of even higher PV penetration. Efficient deployment of the grid-flexibility options needed to maintain solar's value will require various innovations, from the development of communication, control, and energy storage technologies to the implementation of new market rules and operating procedures.

14 SOLAR ENERGY↗

An integrated model of the Space Station Freedom active thermal control system

A flexible, generic model of the Space Station Freedom active thermal control system has been developed which is designed to analyze dynamic interactions of the major subsystems of the ATCS. Models are described for the components of the central thermal bus, the radiator external thermal environment, and the internal thermal control system. Two programs are described which facilitate the development of the integrated ATCS model. The first, SIMRAD, simplifies an external thermal environment model given a desired level of accuracy in integrated model performance. The model reduction technique is shown to reduce model execution time significantly while maintaining the desired accuracy. The second, GENFLU, generates SINDA/FLUINT input code for the evaporator and load interface models and automates the integration of load submodels. The component submodels and integration techniques were used to create an integrated model of the thermal control system for an early assembly flight configuration. The results demonstrate the utility of the integrated model in studying dynamic interactions of the ATCS subsystems.

Tandler, John J.↗

Control law synthesis and optimization software for large order aeroservoelastic systems

A flexible aircraft or space structure with active control is typically modeled by a large-order state space system of equations in order to accurately represent the rigid and flexible body modes, unsteady aerodynamic forces, actuator dynamics and gust spectra. The control law of this multi-input/multi-output (MIMO) system is expected to satisfy multiple design requirements on the dynamic loads, responses, actuator deflection and rate limitations, as well as maintain certain stability margins, yet should be simple enough to be implemented on an onboard digital microprocessor. A software package for performing an analog or digital control law synthesis for such a system, using optimal control theory and constrained optimization techniques is described.

Mukhopadhyay, V.↗

Flexibility Reserve in Power Systems: Definition and Stochastic Multi-Fidelity Optimization

This paper defines flexibility reserve trajectory as a single reserve product that not only supplies the energy imbalance in real-time operation but also the resulting ramping requirements by embedding the flexible ramping trajectories as time derivative of the reserve trajectories. Further, a stochastic optimization model is proposed for multi-fidelity co-optimization of energy and flexibility reserve in day-ahead power systems operation. The proposed model integrates operation decisions with different levels of modeling fidelity in a single stochastic optimization problem. More specifically, day-ahead energy trajectories, day-ahead flexibility reserve capacity trajectories, and real-time flexibility reserve deployment trajectories are modeled by Bernstein polynomials with different degrees as required to match the load and renewable generation with different levels of variability in day-ahead and real-time operations. The proposed model is implemented on the IEEE reliability test system using load and solar generation data of California ISO, where the numerical results demonstrate that the proposed model schedules a reserve capacity that more accurately matches the real-time energy imbalance and ramping requirements of net-load, while reducing the total operation cost of the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flexibility Requirements for Energy Systems with Renewable Generation under Forecast Uncertainties

Energy systems with high fractions of renewable energy-based resources require adequate assets providing flexibility in electricity usage to maximize the benefits of renewable energy. In this paper, we provide an analytical approach to estimate the flexibility requirements of such energy systems, with forecast uncertainties in both demand and generation. Our analytical results show that even with forecast errors, the expected system operating cost decreases with an increase in the amount of flexibility capacity -- however, there is an inflection point, beyond which addition of further flexibility capacity does not reduce expected system cost any further. Additionally, an enumeration-based approach is presented to estimate the maximum flexibility capacity needed to optimize the operating cost. Numerical experiments conducted on a network-abstracted modified IEEE 30-bus system are used for empirical validation and gaining additional insights on the effect of prosumers' willingness to offer flexibility on the dispatch performance.

Bhattacharya, Saptarshi↗

Metrology System for a Large, Somewhat Flexible Telescope

A proposed metrology system would be incorporated into a proposed telescope that would include focusing optics on a rigid bench connected via a deployable mast to another rigid bench holding a focal-plane array of photon counting photodetectors. Deformations of the deployable mast would give rise to optical misalignments that would alter the directions (and, hence, locations) of incidence of photons on the focal plane. The metrology system would measure the relative displacement of the focusing- optics bench and the focal-plane array bench. The measurement data would be used in post-processing of the digitized photodetector outputs to compensate for the mast-deformation-induced changes in the locations of incidence of photons on the focal plane, thereby making it possible to determine the original directions of incidence of photons with greater accuracy. The proposed metrology system is designed specifically for the Nuclear Spectroscopic Telescope Array (NuSTAR) a proposed spaceborne x-ray telescope. The basic principles of design and operation are also applicable to other large, somewhat flexible telescopes, both terrestrial and spaceborne. In the NuSTAR, the structural member connecting the optical bench and the photodetector array would be a 10-m-long deployable mast, and there is a requirement to keep errors in measured directions of incidence of photons below 10 arc seconds (3 sigma). The proposed system would include three diode lasers that would be mounted on the focusing-optics bench. For clarity, only one laser is shown in the figure, which is a greatly simplified schematic diagram of the system. Each laser would be aimed at a position-sensitive photodiode that would be mounted on the detector bench alongside the aforementioned telescope photodetector array. The diode lasers would operate at a wavelength of 830 nm, each at a power of 200 mW. Each laser beam would be focused to a spot of .1-mm diameter on the corresponding position-sensitive photodiode. To reduce the effect of sunlight on the measurements, a one-stage light baffle and an 830-nm transmission filter of 10-nm bandwidth would be placed in front of the position- sensitive photodiode. For each metrology reading, the output of the position-sensitive detector would be sampled and digitized twice: once with the lasers turned on, then once with the lasers turned off. The data from these two sets of samples would be subtracted from each other to further reduce the effects of sun glints or other background light sources.

Liebe, Carl Christian↗

Flexible Nuclear Energy for Clean Energy Systems

As part of the Nuclear Innovation: Clean Energy Future initiative, this report describes flexibility in nuclear systems, the value it can bring, and international experiences surrounding flexible nuclear energy. Flexible nuclear energy for this report is defined as “The ability of nuclear energy generation to economically provide energy services at the time and location they are needed by end-users. These energy services can include both electric and non-electric applications utilizing both traditional nuclear power plants and advanced integrated systems.” Flexibility in nuclear systems is enabled by three main mechanisms: core ramping, integrated energy systems with multiple byproducts, and thermal storage. The value of this flexibility on a $\$$/MW and a $\$$/MWh basis can be estimated through a combination of physics and economics modeling. International agencies describe their experiences in operating flexible nuclear systems and describe their plans for increasing nuclear flexibility in a clean energy system, likely with a high penetration of variable renewable energy.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Energy Storage Requirements for Achieving 50% Solar Photovoltaic Energy Penetration in California

We estimate the storage required to enable PV penetration up to 50% in California (with renewable penetration over 66%), and we quantify the complex relationships among storage, PV penetration, grid flexibility, and PV costs due to increased curtailment. We find that the storage needed depends strongly on the amount of other flexibility resources deployed. With very low-cost PV (three cents per kilowatt-hour) and a highly flexible electric power system, about 19 gigawatts of energy storage could enable 50% PV penetration with a marginal net PV levelized cost of energy (LCOE) comparable to the variable costs of future combined-cycle gas generators under carbon constraints. This system requires extensive use of flexible generation, transmission, demand response, and electrifying one quarter of the vehicle fleet in California with largely optimized charging. A less flexible system, or more expensive PV would require significantly greater amounts of storage. The amount of storage needed to support very large amounts of PV might fit within a least-cost framework driven by declining storage costs and reduced storage-duration needs due to high PV penetration.

14 SOLAR ENERGY↗