Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Stabilizing NMC 811 Li-Ion Battery Cathode through a Rapid Coprecipitation Process

Improving the capacity of LiNi x Mn y Co 1-x-y O 2 (NMC) by increasing the Ni content results in materials with poor cycling performance and reduced thermal stability. These problems can be alleviated by creating concentration gradients in the materials, but this requires more expensive batch processing. Herein, a simple process is described that can create a coating that penetrates into the precursor particles, creating unique gradients in the precursor material. The coated material demonstrates improved cycling performance and thermal stability as compared to uncoated materials. Additionally, rapid heating to simulate a thermal runaway event while observing these materials with X-rays gives a deeper understanding of how the coating affects the decomposition process.

25 ENERGY STORAGE↗

A radiant heating test facility for space shuttle orbiter thermal protection system certification

A large scale radiant heating test facility was constructed so that thermal certification tests can be performed on the new generation of thermal protection systems developed for the space shuttle orbiter. This facility simulates surface thermal gradients, onorbit cold-soak temperatures down to 200 K, entry heating temperatures to 1710 K in an oxidizing environment, and the dynamic entry pressure environment. The capabilities of the facility and the development of new test equipment are presented.

Sherborne, W. D.↗

Enabling Load Following Capability in the Transatomic Power MSR

This project is dedicated towards designing a fuel processing system that enables liquid-fueled molten salt reactors (MSR) to load follow by removing the dissolved xenon in the fuel salt. As one of the Gen-IV nuclear reactor concepts, the molten salt reactor receives increasing development interests in the recent years. One distinguishing feature of the liquid-fueled molten salt reactor is its improved ability to operate in a load-following mode by including the unique online fission product removal system. Load-following means that the reactor changes its power output based on the demand on the grid. Most of the current operating nuclear reactors have limited load-following ability and operate as the base load on the grid. Due to the rapid increase of solar energy, the requirement on load-following capacity is significantly increased because of the varying power output of the solar panels, yet the traditional load-following capacity is expected to decrease as the decarbonization of the grid continues. Therefore, the ability to perform load-following operation for the nuclear reactors will greatly enhance the resilience of the grid and make nuclear energy more economically competitive. This load-following feature is included in many commercial molten salt reactor designs, such as the designs by Transatomic Power, Terrestrial Energy, and Flibe Energy. Unfortunately, detailed analysis of the fuel processing system for commercial scale MSRs is still lacking, as well as how the fuel processing quantitively impacts the load-following operation. Moreover, experimental data for many of the underlying physics of fuel processing is limited. This project aims to pave the way for the fuel processing technology to advance to the commercial stage by performing combined experimental and simulation research. During the project period, four interconnected aspects of the development of the fuel processing system in liquid-fueled molten salt reactors are investigated. These aspects are the simulation and analysis of the fission product removal system, the fuel cycle simulation, the coupled reactor neutronics and thermal hydraulics transient simulation, and the gaseous fission product removal experiment. Multiphase CFD simulations are performed for components of the processing systems, and simplified air-water experiments are carried out to provide validation data. It is concluded that the CFD simulation can satisfactorily predict the system level performance of the components, and engineering models are constructed based on this success. Fuel cycle analysis is performed for two representative MSR design, the MSBR and the Transatomic Power MSR. Open-source code SaltProc is developed to incorporate the unique fuel processing system of the MSRs. It is concluded that the removal of xenon is essential for load-following operation in thermal spectrum MSR and Molten Salt Breeder Reactor. For the Transatomic Power MSR, the xenon poisoning effect is negligible due to its relatively fast neutron spectrum, though the overall fuel cycle economics still benefits from the removal of xenon. Coupled reactor neutronics and thermal hydraulics transient simulation is performed specifically for the Transatomic Power MSR. It is concluded that the reactor core design could perform power ramping fast enough to satisfy load-following operation. Combining the findings from each aspect, it is concluded that the load-following operation of a thermal neutron MSR is dependent upon the removal of xenon, which could be achieved for a commercial sized reactor using continuous inert gas sparging in a separate system with reasonable dimensions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement of transient strain and surface temperature on simulated turbine blades using noncontacting techniques

Noncontacting techniques were used to measure strain and temperature in thermally cycled simulated turbine blades. An electro-optical extensometer was used to measure the displacement between parallel targets mounted on the leading edge of the blades throughout a complete heating and cooling cycle. An infrared photographic pyrometry method was used to measure blade steady state surface temperature. The blade was cyclically heated and cooled by moving it into and out of a Mach 1 hot-gas stream. Transient leading edge strain and steady state surface temperature distributions are presented for blades of three different configurations.

Calfo, F. D.↗

Simulation of Hydrogen Flow in a Nuclear-Thermal Propulsion Reactor Subsystem: Conjugate Heat Transfer in Surrogate Fuel Elements and Flow Through the Dome Inlet to the Fuel Elements

NASA is performing research related to a Nuclear-Thermal Propulsion (NTP) engine as a step toward future manned missions to Mars. BWX Technologies (BWXT), in conjunction with NASA, is developing the reactor subsystem for that NTP engine design. As a subset of the reactor subsystem, the fuel elements have continued to evolve in design, as well. A set of experiments within the Nuclear Thermal Reactor Element Environmental Simulator at NASA Marshall has been developed to compliment that design process, including a series of surrogate fuel elements. Before the experiments of each surrogate can be completed, they must be deemed safe using structural analysis, which itself requires thermal and conjugate heat transfer analyses of the articles. Therefore, conjugate heat transfer simulations of the hydrogen flow through the test article fuel element surrogates were developed to provide estimates of heating, as well as to provide assessments of the fluid flow through the elements. The set of simulations involved not only the separate test conditions, but also a sensitivity study to estimate the effect of physical parameter uncertainty on the selected quantities of interest. Additionally, the fluid flow through the fore section inner plenum dome to the entrances of the fuel elements, another section of the reactor subsystem still under active development, was simulated and analyzed. The simulations show the extent of non-uniformity in the mass flow distribution across the dome outlets. Furthermore, additional analyses estimate the effects of required flow blockages on the potential development of flow dynamics. These analyses were used in the design cycle to make improvements to the reactor subsystem design.

Kalen E. Braman↗

Evaluation of flat-plate collector efficiency under controlled conditions in a solar simulator

The measured thermal efficiencies of 35 collectors tested with a solar simulator, along with the correlation equations used to generalize the data, are presented. The single correlation used is shown to apply to all the different types of collectors tested, including one with black paint and one cover, one with a selective surface coating and two covers, and an evacuated-tube collector. The test and correlation technique is also modified by using a shield so that collectors larger than the simulator test area can also be tested. This technique was verified experimentally for a shielded collector for which the collector shielded area was 31% of the solar simulator radiation area. A table lists all the collectors tested, the collector areas, and the experimental constants used to correlate the data for each collector.

Johnson, S. M.↗

Evaluation of flat-plate collector efficiency under controlled conditions in a solar simulator

The measured thermal efficiencies of 35 collectors tested with a solar simulator, along with the correlation equations used to generalize the data, are presented in this report. The single correlation used is shown to apply to all the different types of collectors tested, including one with black paint and one cover, one with a selective surface coating and two covers, and an evacuated-tube collector. The test and correlation technique is also modified by using a shield so that collectors larger than the simulator test area can also be tested. This technique was verified experimentally for a shielded collector for which the collector shielded area was 31% of the solar simulator radiation area. A table lists all the collectors tested, the collector areas, and the experimental constants used to correlate the data for each collector.

Johnson, S. M.↗

Analysis of Conduction Cooling Strategies for Wire Arc Additive Manufacturing

Metal additive manufacturing (AM) processing consists of numerous parameters which take time to optimize for various geometries. One aspect of the metal AM process that continues to be explored is the control of thermal energy accumulation during component manufacturing due to the melting and solidification of the feedstock. Excessive energy accumulation causes thermal failure of the component while minimal energy accumulation causes lack of fusion with the build plate or previous layer. The ability to simulate the thermal response of an AM component can increase research efficiency by reducing the time to optimize thermal energy accumulation. This paper presents an effective implementation of finite element analysis to determine the thermal response of a wire arc additive manufactured component with various build plate sizes and cooling methods including, integral build plate cooling, oversized build plates with passive cooling, and non-integral build plate cooling. The use of integral build plate cooling channels was shown to decrease the interpass temperature at the conclusion of the build process by 55% and build plate temperature by 96% compared to the conventionally deposited sample with 20 second dwell time. The use of a tall build plate with passive cooling was shown to reduce the interpass temperature by 32% as compared to the conventionally deposited sample with 20 second dwell time. Each cooling strategy evaluated decreased the interpass temperature within a range of 20–55% which enables higher deposition rates and decreased dwell times during depositions. The cooling strategies are designed to be implemented in a hybrid or retrofit AM platform to mitigate concerns of the thermal input from the additive process having detrimental effects on the precision of the machining process. This paper shows that accurate simulations of all strategies can be used to accurately predict the thermal response of the various strategies discussed. These cooling strategies will allow for increased deposition rates with comparable interpass temperature and decreased dwell time, increasing deposition efficiency. This model and these simulations are verified by experimental results. It is concluded that passive strategies, such as the over-sized tall build plate, can be used when liquid coolant in the AM environment could negatively affect the deposition process. Active cooling strategies, such as the integral build plate cooling could be used if low thermal conductivity materials are deposited or higher material deposition rates are desired. This paper discusses the use of active and passive cooling used during AM and shows how a simulation model can be used to make design choices for cooling strategies. The model also enables verification of select critical process parameters such as dwell times for a desired interpass temperature.

Heinrich, Lauren↗

G-189A analytical simulation of the integrated waste management-water system using radioisotopes for thermal energy

An analytical simulation of the RITE-Integrated Waste Management and Water Recovery System using radioisotopes for thermal energy was prepared for the NASA-Manned Space Flight Center (MSFC). The RITE system is the most advanced concept water-waste management system currently under development and has undergone extended duration testing. It has the capability of disposing of nearly all spacecraft wastes including feces and trash and of recovering water from usual waste water sources: urine, condensate, wash water, etc. All of the process heat normally used in the system is produced from low penalty radioisotope heat sources. The analytical simulation was developed with the G189A computer program. The objective of the simulation was to obtain an analytical simulation which can be used to (1) evaluate the current RITE system steady state and transient performance during normal operating conditions, and also during off normal operating conditions including failure modes; and (2) evaluate the effects of variations in component design parameters and vehicle interface parameters on system performance.

Coggi, J. V.↗

Thermal conductivity of 3D-printed block-copolymer-inspired structures

This study primarily focuses on examining the impact that geometric structure has on thermal conductivity of multi-phase constructs in different 3D-printed poly(lactic acid), PLA, samples. The investigated structures are inspired by morphologies formed by diblock copolymers: lamellae, hexagonally packed cylinders, and gyroid. This research also investigates how volume percentage and material combination influence the thermal conductivity of these structures. Further, the samples can be tailored to simulate various thermal management structures observed in practical applications, such as thermal interface materials in electronic devices. Thermal conductivity ratio is controlled using air, the least conductive material at 0.026 W/(m K), PLA at 0.136 W/(m K), and thermal paste at 5.11 W/(m K). Different models were tested against thermal conductivity measurements in order to capture the effect of material type (PLA-Air versus PLA-Thermal Paste), volume percentage, structure, and orientation. Simple, effective medium models were good predictions of thermal conductivity in lamellar structures, but it was necessary to develop models for conduction through cylindrical and gyroid structures. Finally, all results were normalized to find a universal model that is independent of structure and material. This approach provides a simple method to predict how to reduce or enhance transport properties and heat management capabilities of 3D printed objects.

36 MATERIALS SCIENCE↗

Functional and dynamics testing of the flexible solar array for the communications technology satellite

The test objectives, test methods, thermal environmental simulations, and test results are described, for a series of combined dynamic, thermal, and vacuum environmental tests on a Deployable Solar Array for the Communications Technology Satellite. Six major resonant structural modes were observed over an excitation range of 0.1-1.0 Hz. Corresponding modal damping factors were found to be between 0.001 and 0.01. Variation of temperature environments between -125 C and 42 C did not significantly affect the characteristics of the fundamental modes, but did influence some of the higher modes. Superharmonic response behavior was observed. The tests also verified functional mechanical performance of the solar array under thermal and vacuum conditions.

Harrison, T. D.↗

Results of accelerated thermal cycle tests of solar cells modules

Various candidate solar panel designs were evaluated, both theoretically and experimentally, with respect to their thermal cycling survival capability, and in particular with respect to an accelerated simulation of thermal cycles representative of Viking '75 mission requirements. The experimental results were obtained on 'mini-panels' thermally cycled in a newly installed automated test facility herein described. The resulting damage was analyzed physically and theoretically, and on the basis of these analyses the panel design was suitably modified to significantly improve its ability to withstand the thermal environment. These successful modifications demonstrate the value of the complementary theoretical-experimental approach adopted, and discussed in detail in this paper.

Berman, P.↗

Development of improved high pressure turbine outer gas path seal components

A plasma sprayed graded layered ceramic/metallic (ZrO2/CoCrAlY) seal was evaluated for JT9D turbine application by rig and engine tests. Four cyclic thermal shock rig tests were conducted during the program. Three completed 1000 simulated engine thermal cycle tests and the fourth completed 500 cycles without severe cracking or spalling. Three ceramic seals were installed in a JT9D experimental engine to evaluate the effect of the engine thermal environment on the seals. All three seals completed the test successfully without severe cracking or spalling. The three seals did have slight laminar cracks at the 85/15-40/60 ZrO2/CoCrAlY interface. The second engine test evaluated the rub capabilities of the seal. Six ceramic seals were installed in the engine with fourteen abrasive tip blades. Three of the six seals rubbed to a depth of 24 mils. Eight of the fourteen abrasive tip blades showed evidence of wear. Three of the eight blades wore a maximum of five mils. Engine rub test results demonstrated the potential of reducing turbine clearances and thereby improving engine performance by use of sprayed ceramic seals.

Shiembob, L. T.↗

Orbiter integrated active thermal control subsystem test

Integrated subsystem level testing of the systems within the orbiter active thermal chamber capable of simulating ground, orbital, and entry temperature and pressure profiles. The test article was in a closed loop configuration that included flight type and functionally simulated protions of all ATCS components for collecting, transporting, and rejecting orbiter waste heat. Specially designed independently operating equipment simulated the transient thermal input from the cabin, payload, fuel cells, freon cold plates, hydraulic system, and space environment. Test team members using data, controls, and procedures available to a flight crew controlled the operation of the ATCS. The ATCS performance met or exceeded all thermal and operational requirements for planned and contingency mission support.

Jaax, J. R.↗

Thermal Vacuum Facility for Testing Thermal Protection Systems

A thermal vacuum facility for testing launch vehicle thermal protection systems by subjecting them to transient thermal conditions simulating re-entry aerodynamic heating is described. Re-entry heating is simulated by controlling the test specimen surface temperature and the environmental pressure in the chamber. Design requirements for simulating re-entry conditions are briefly described. A description of the thermal vacuum facility, the quartz lamp array and the control system is provided. The facility was evaluated by subjecting an 18 by 36 in. Inconel honeycomb panel to a typical re-entry pressure and surface temperature profile. For most of the test duration, the average difference between the measured and desired pressures was 1.6% of reading with a standard deviation of +/- 7.4%, while the average difference between measured and desired temperatures was 7.6% of reading with a standard deviation of +/- 6.5%. The temperature non-uniformity across the panel was 12% during the initial heating phase (t less than 500 sec.), and less than 2% during the remainder of the test.

Daryabeigi, Kamran↗

Therma1 Conductivity and Durability of Advanced Thermal Barrier Coatings

Thermal barrier coatings (TBCs) will play a crucial role in advanced gas turbine engines because of their ability to further increase engine operating temperature and reduce cooling, thus helping to achieve engine emission and efficiency goals. Future TBCs must be designed with increased phase stability, lower thermal conductivity, and improved sintering and thermal stress resistance in order to effectively protect engine hot-section components. Advanced low conductivity TBCs are being developed at NASA by incorporating multi-component oxide dopants into zirconia-yttria or hafnia-yttria to promote the formation of thermodynamically stable defect clusters within the coating structures. This presentation will primarily focus on thermal conductivity and durability of the novel defect cluster thermal barrier coatings for turbine airfoil and combustor applications, determined by a unique CO2 laser heat-flux approach. The laser heat-flux testing approach emphasizes the real-time monitoring and assessment of the coating thermal conductivity under simulated engine temperature and thermal gradient conditions. The conductivity increase due to coating sintering (and/or phase change) and the conductivity decrease due to coating delamination have been determined under steady-state, cyclic, uniform or non-uniform heat-flux conditions. The coating radiation flux resistance has been evaluated by varying coating thermal gradients, and also by using a laser-heated radiative-flux source. Advanced multi-component TBC systems have been shown to have significantly reduced thermal conductivity and improved high temperature stability due to the nano-sized, low mobility defect clusters associated with the paired rare earth dopant additions. The effect of oxide defect cluster dopants on coating thermal conductivity, thermal stability and furnace cyclic durability will also be discussed. The current low conductivity TBC systems have demonstrated long-term cyclic durability at very high temperatures which is far beyond the baseline ZrO2-Y2O3 capabilities.

Zhu, Dong-Ming↗

Design of a Thermal Testbed for Metrology of Active Antennas

NASA mission requirements have driven an increased interest in active phased array antennas (APAA) for space-based user communication terminals. Recent advancements in 5G technology have driven down the cost of APAA development and manufacturing all while providing a technology solution that covers many existing Ka-Band satellite communication spectrum bands. While these developments have provided ample opportunities to leverage new chips and arrays for use in space, there is also a need to evaluate these antennas in a relevant environment. Active arrays, as designed for use in 5G, require thermal management to avoid damage to the device as well as to maintain performance. Measured performance under various thermal conditions is essential both for understanding overall APAA performance and ensuring operation is within required tolerances. To address these measurement needs, the SmallSat Ka-band Operations User Terminal (SKOUT) project at the NASA Glenn Research Center (GRC) developed a test environment that combines traditional antenna and communication system metrology with a conduction cooling/heating thermal control system to simulate the space thermal environment. This paper will address the metrologysystem design and performance specifications as well as test article setup and operation. Tests that are typically performed at ambient temperature can now be performed over the typical temperature range of a Low Earth Orbit (LEO) mission. These tests include error vector magnitude (EVM), gain to noise temperature (G/T), antenna patterns, and non-linear characterization. The paper will cover the configuration for each test and provide results from a recent test campaign. Results illustrate the importance of higher fidelity environmental testing when evaluating the performance of an APAA.

active phased array↗