Search NASA⌕ Search

SEARCH · Search NASA

Results for “time resolved”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Lattice-level observation of the elastic-to-plastic relaxation process with subnanosecond resolution in shock-compressed Ta using time-resolved in situ Laue diffraction

We report direct lattice level measurements of plastic relaxation kinetics through time-resolved, in-situ Laue diffraction of shock-compressed single-crystal [001] Ta at pressures of 27-210 GPa. For a 50 GPa shock, a range of shear strains is observed extending up to the uniaxial limit for early data points (<0.6 ns) and the average shear strain relaxes to a near steady state over ~1 ns. For 80 and 125 GPa shocks, the measured shear strains are fully relaxed already at 200 ps, consistent with rapid relaxation associated with the predicted threshold for homogeneous nucleation of dislocations occurring at shock pressure ~65 GPa. The relaxation rate and shear stresses are used to estimate the dislocation density and these quantities are compared to the Livermore Multiscale Strength model as well as various molecular dynamics simulations.

36 MATERIALS SCIENCE↗

The time-resolved atomic, molecular and optical science instrument at the Linac Coherent Light Source

The newly constructed time-resolved atomic, molecular and optical science instrument (TMO) is configured to take full advantage of both linear accelerators at SLAC National Accelerator Laboratory, the copper accelerator operating at a repetition rate of 120 Hz providing high per-pulse energy as well as the superconducting accelerator operating at a repetition rate of about 1 MHz providing high average intensity. Both accelerators power a soft X-ray free-electron laser with the new variable-gap undulator section. With this flexible light source, TMO supports many experimental techniques not previously available at LCLS and will have two X-ray beam focus spots in line. Thereby, TMO supports atomic, molecular and optical, strong-field and nonlinear science and will also host a designated new dynamic reaction microscope with a sub-micrometer X-ray focus spot. The flexible instrument design is optimized for studying ultrafast electronic and molecular phenomena and can take full advantage of the sub-femtosecond soft X-ray pulse generation program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Exhaust runner soot diagnostic conceptual design for in-line time-resolved soot mass measurements

The Exhaust Runner Soot Diagnostic (ERSD) system is an in-line, time-resolved soot mass measurement system designed to allow rapid measurement of soot mass flux to detect and measure cyclic variability. The ERSD system design was generally split into two sections: conceptual mechanical design and measurement design—meaning the relevant calculations to demonstrate the feasibility of our planned measurement approach. For measurement design, the Beer-Lambert Law was the central focus for design justification. With measured values for the Filter Smoke Number (FSN) and a conversion to soot mass concentration, the required effective optical path length can be calculated for a desired light attenuation percentage. For mechanical design, the key constraints were space and modularity. The design must be placed into an existing mechanical setup with relative ease, as well as being modular enough to be implemented on other engines. The crux of the mechanical design was proper sealing and optical access, as both are crucial to the system's effectiveness. For proper sealing, extensive thermal expansion calculations were performed alongside O-ring design guides to produce the desired sealing and custom gland dimensions. For maximizing optical access, many iterations were modeled to provide full optical access while maintaining effective gas sealing.

02 PETROLEUM↗

Time-Resolved Optical Pump-Resonant X-ray Probe Spectroscopy of 4-Thiouracil: A Simulation Study

We theoretically monitor the photoinduced ππ* → nπ* internal conversion process in 4-thiouracil (4TU), triggered by an optical pump. The element-sensitive spectroscopic signatures are recorded by a resonant X-ray probe tuned to the sulfur, oxygen, or nitrogen K-edge. We employ high-level electronic structure methods optimized for core-excited electronic structure calculation combined with quantum nuclear wavepacket dynamics computed on two relevant nuclear modes, fully accounting for their quantum nature of nuclear motions. We critically discuss the capabilities and limitations of the resonant technique. For sulfur and nitrogen, we document a pre-edge spectral window free from ground-state background and rich with ππ* and nπ* absorption features. The lowest sulfur K-edge shows strong absorption for both ππ* and nπ*. In the lowest nitrogen K-edge window, we resolve a state-specific fingerprint of the ππ* and an approximate timing of the conical intersection via its depletion. A spectral signature of the nπ* transition, not accessible by UV–vis spectroscopy, is identified. The oxygen K-edge is not sensitive to molecular deformations and gives steady transient absorption features without spectral dynamics. Here, the ππ*/nπ* coherence information is masked by more intense contributions from populations. Altogether, element-specific time-resolved resonant X-ray spectroscopy provides a detailed picture of the electronic excited-state dynamics and therefore a sensitive window into the photophysics of thiobases.

97 MATHEMATICS AND COMPUTING↗

Excited-state dynamics of furan studied by sub-20-fs time-resolved photoelectron imaging using 159-nm pulses

The excited-state dynamics of furan were studied by time-resolved photoelectron imaging using a sub-20-fs deep UV (198 nm) and vacuum UV (159 nm) light source. The 198- and 159-nm pulses produce photoionization signals in both pump-probe and probe-pump pulse sequences. When the 198-nm pulse precedes the 159-nm pulse, it creates the {sup 1}A{sub 2}(3s) Rydberg and {sup 1}B{sub 2}(ππ{sup ∗}) valence states, and the former decays exponentially with a time constant of about 20 fs whereas the latter exhibits more complex wave-packet dynamics. When the 159-nm pulse precedes the 198-nm pulse, a wave packet is created on the {sup 1}A{sub 1}(ππ{sup ∗}) valence state, which rapidly disappears from the observation window owing to structural deformation. The 159-nm photoexcitation also creates the 3s and 3p{sub x,y} Rydberg states non-adiabatically.

74 ATOMIC AND MOLECULAR PHYSICS↗

Time-resolved observation of thermally activated rupture of a capillary-condensed water nanobridge

The capillary-condensed liquid bridge is one of the most ubiquitous forms of liquid in nature and contributes significantly to adhesion and friction of biological molecules as well as microscopic objects. Despite its important role in nanoscience and technology, the rupture process of the bridge is not well understood and needs more experimental works. Here, we report real-time observation of rupture of a capillary-condensed water nanobridge in ambient condition. During slow and stepwise stretch of the nanobridge, we measured the activation time for rupture, or the latency time required for the bridge breakup. By statistical analysis of the time-resolved distribution of activation time, we show that rupture is a thermally activated stochastic process and follows the Poisson statistics. In particular, from the Arrhenius law that the rupture rate satisfies, we estimate the position-dependent activation energies for the capillary-bridge rupture.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Defect characterization in ZnGeP2 by time-resolved photoluminescence

The native defect-related optical properties of ZnGeP2 are studied by steady-state and time-resolved photoluminescence. ZnGeP2 crystals grown from the vapor phase by high pressure physical vapor transport (HPVT) and from the melt by gradient freezing (GF) show a broad infrared emission with peak position at 1.2 eV with a decay time constant of a few micro-s and a faster recombination center peaked at 1.68 eV. The decay transient for the emission at 1.2 eV exhibits features of classical donor-acceptor recombination and is linked to close-pairs that are tentatively associated with germanium-on-zinc antisite donors and zinc vacancy acceptors. Higher energetic luminescence structures at 1.6eV and 1.7eV are revealed after annealing of the ZnGeP2 crystals and are associated with the formation zinc and phosphorous vacancies in the near surface region. ZnGeP2 crystals grown by HPVT from zinc and phosphorus supersaturated vapor compositions show additional emission structure at 1.8 eV and a sharp donor-acceptor emission at 1.778 eV that is related to the presence of additional donor states.

Dietz, N.↗

Study of strain propagation in laser irradiated silicon crystal by time-resolved diffraction of K-{alpha} x-ray probe of different photon energies

An experimental study on the time resolved x-ray diffraction from laser shocked silicon crystal, carried out using a 10 TW Ti:sapphire laser system, is presented. The characteristic K{sub {alpha}} x-ray line radiation generated by 45 fs laser produced plasmas of two different target materials (iron and copper) is used as the probe, whereas the stretched pulse of sub-nanosecond duration (pump), derived from the same laser, is used to compress the sample. The use of x-ray probe of different photon energies yields information about the strain over a greater crystal depth. The dynamics of the strain propagation is inferred by monitoring the evolution of rocking curve width of the shocked sample at different time delays between the pump and the probe pulse. The shock velocity deduced from these measurements is {approx}10{sup 6} cm/s, consistent with the sound velocity in bulk silicon. The maximum elastic compression observed is 0.4%, indicating a pressure of 0.8 GPa.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-F-J-190: Time Resolved Range Measurement System Using Scintillator and CCD Camera for the Slow Beam Extraction

Purpose: To investigate the time structure of the range, we have verified the rang shift due to the betatron tune shift with several synchrotron parameters. Methods: A cylindrical plastic scintillator block and a CCD camera were installed on the black box. Using image processing, the range was determined the 80 percent of distal dose of the depth light distribution. The root mean square error of the range measurement using the scintillator and CCD system is about 0.2 mm. Range measurement was performed at interval of 170 msec. The chromaticity of the synchrotron was changed in the range of plus or minus 1% from reference chromaticity in this study. All of the particle inside the synchrotron ring were extracted with the output beam intensity 1.8×10{sup 8} and 5.0×10{sub 7} particle per sec. Results: The time strictures of the range were changed by changing of the chromaticity. The reproducibility of the measurement was sufficient to observe the time structures of the range. The range shift was depending on the number of the residual particle inside the synchrotron ring. Conclusion: In slow beam extraction for scanned carbon-ion therapy, the range shift is undesirable because it causes the dose uncertainty in the target. We introduced the time-resolved range measurement using scintillator and CCD system. The scintillator and CCD system have enabled to verify the range shift with sufficient spatial resolution and reproducibility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of the foil-on-hohlraum technique for the magnetic recoil spectrometer for time-resolved neutron measurements at the National Ignition Facility

The next-generation Magnetic Recoil Spectrometer, called MRSt, will provide time-resolved measurements of the deuterium-tritium-neutron spectrum from inertial confinement fusion implosions at the National Ignition Facility. These measurements will provide critical information about the time evolution of the fuel assembly, hot-spot formation, and nuclear burn. The absolute neutron spectrum in the energy range of 12-16 MeV will be measured with high accuracy (~5%), unprecedented energy resolution (~100 keV) and, for the first time ever, time resolution (~20 ps). Crucial to the design of the system is a CD conversion foil for the production of recoil deuterons positioned as close to the implosion as possible. The foil-on-hohlraum technique has been demonstrated by placing a 1-mm-diameter, 40-μm-thick CD foil on the hohlraum diagnostic band along the line-of-sight of the current time-integrated MRS system, which measured the recoil deuterons. In addition to providing validation of the foil-on-hohlraum technique for the MRSt design, substantial improvement of the MRS energy resolution was demonstrated.

42 ENGINEERING↗

Time-resolved observation of fast domain-walls driven by vertical spin currents in short tracks

We present time-resolved measurements of the displacement of magnetic domain-walls (DWs) driven by vertical spin-polarized currents in track-shaped magnetic tunnel junctions. In these structures, we observe very high DW velocities (600 m/s) at current densities below 10{sup 7} A/cm{sup 2}. We show that the efficient spin-transfer torque combined with a short propagation distance allows avoiding the Walker breakdown process and achieving deterministic, reversible, and fast (≈1 ns) DW-mediated switching of magnetic tunnel junction elements, which is of great interest for the implementation of fast DW-based spintronic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Flow-Through Reaction Cell that Couples Time - Resolved Analysis

A non-metallic flow-through reaction cell is described, designed for in situ time-resolved X-ray diffraction coupled with stable isotope analysis. The experimental setup allows the correlation of Cu isotope fractionation with changes in crystal structure during copper sulfide dissolution. This flow-through cell can be applied to many classes of fluid-mineral reactions that involve dissolution or ion exchange.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Femtosecond time-resolved impulsive stimulated Raman spectroscopy using sub-7-fs pulses: Apparatus and applications

We describe details of the setup for time-resolved impulsive stimulated Raman spectroscopy (TR-ISRS). In this method, snapshot molecular vibrational spectra of the photoreaction transients are captured via time-domain Raman probing using ultrashort pulses. Our instrument features transform-limited sub-7-fs pulses to impulsively excite and probe coherent nuclear wavepacket motions, allowing us to observe vibrational fingerprints of transient species from the terahertz to 3000-cm{sup −1} region with high sensitivity. Key optical components for the best spectroscopic performance are discussed. The TR-ISRS measurements for the excited states of diphenylacetylene in cyclohexane are demonstrated, highlighting the capability of our setup to track femtosecond dynamics of all the Raman-active fundamental molecular vibrations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Field transients of coherent terahertz synchrotron radiation accessed via time-resolving and correlation techniques

Decaying oscillations of the electric field in repetitive pulses of coherent synchrotron radiation in the terahertz frequency range was evaluated by means of time-resolving and correlation techniques. Comparative analysis of real-time voltage transients of the electrical response and interferograms, which were obtained with an ultrafast zero-bias Schottky diode detector and a Martin-Puplett interferometer, delivers close values of the pulse duration. Consistent results were obtained via the correlation technique with a pair of Golay Cell detectors and a pair of resonant polarisation-sensitive superconducting detectors integrated on one chip. The duration of terahertz synchrotron pulses does not closely correlate with the duration of single-cycle electric field expected for the varying size of electron bunches. We largely attribute the difference to the charge density oscillations in electron bunches and to the low-frequency spectral cut-off imposed by both the synchrotron beamline and the coupling optics of our detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-resolved electrical potential pump – X-ray photoelectron spectroscopy probe developments for investigating dynamic processes occurring at electrochemical interfaces

Electrode–electrolyte interfaces are of critical importance in several fields, including renewable energy, corrosion, and environmental chemistry. However, investigating these interfaces under operational conditions poses considerable challenges due to the limitations of the instrumentation employed. While recent advancements in in situ and operando techniques have enhanced our comprehension of the steady-state properties of solid-liquid interfaces, the dynamic behaviors of these systems remain inadequately explored. This study introduces a time-resolved X-ray photoelectron spectroscopy (XPS) technique designed to capture transient reaction intermediates and charging dynamics at electrified interfaces. The presented proof-of-principle study demonstrates that electrochemical processes, represented by an equivalent electrical circuit (EEC) model, can be probed and understood using square wave voltage pulses of a potentiostat synchronized to the modified data acquisition of an XPS setup. This method offers a valuable alternative to traditional pump–probe techniques, facilitating the investigation of a broader range of electrochemical systems. A dedicated software package for analyzing time- and energy-resolved XPS with a focus on extracting parameters of the EEC is geared towards benchmarking different EECs in future real-world electrochemical experiments.

Electrochemistry↗

Continuous Time-Resolved X-ray Diffraction of the Biocatalyzed Reduction of Mn Oxide

Here we report the first continuous time-resolved X-ray diffraction analysis of a biologically mediated mineral reaction. We incubated total membrane (TM) fractions of the facultative anaerobe Shewanella oneidensis in an anoxic environmental reaction cell with formate (as electron donor via formate dehydrogenase) and powdered birnessite, a layered Mn{sup 3+,4+} oxide common to many soils. Using both synchrotron and conventional X-ray sources, we irradiated the reaction mixtures for up to two weeks and observed bioreduction and dissolution of birnessite and the concomitant precipitation of rhodochrosite (Mn{sup +C}O{sub 3}) and hausmannite (Mn{sup 2+}Mn{sub 2}{sup 3+}O{sub 4}). The high time resolution of these experiments documented systematic changes in crystal structure during the breakdown of birnessite and the emergence of nanocarystalline rhodochrosite. In addition, the relative abundances of birnessite and rhodochrosite were quantified over time for different concentrations of TM fraction, allowing for the determination of rate equations that govern this bioreaction. Importantly, constant irradiation for two weeks did not stop the enzymatic reaction, suggesting that enzymes may be more resilient than whole cells when exposed to X-ray radiation.

36 MATERIALS SCIENCE↗

A fast mechanical shutter for submicrosecond time-resolved synchrotron experiments

A new high-speed high-repetition-rate X-ray beam shutter for time-resolved photocrystallography at synchrotron sources has been developed and tested. The new design is based on a commercially existing DC servomotor and a frequency-lock control capable linear amplifier. Accurate speed control combined with an air bearing results in extremely low jitter in the motor rotation. Measured jitter at rotation speeds of 12,000 to 30,000 r min{sup -1} is less than 2 ns at a 6{sigma} confidence level. The chopper disc is interchangeable, allowing maximum flexibility. The chopper disc currently installed has 45 radial slots which allows synchronization from the 12th to the 20th subfrequencies of the orbit frequency of the Advanced Photon Source storage ring, corresponding to X-ray pulse frequencies of 13.6 to 22.6 kHz. At 30000 r min{sup -1} the opening time window with a 350 {micro}m slot size is 2.11 {micro}s, and correspondingly less with smaller openings, which may be compared with the 3.68 {micro}s orbit time of the Advanced Photon Source. The shutter provides high accuracy and efficient use of X-rays at a modest cost.

43 PARTICLE ACCELERATORS↗