Experimental thermodynamic first and second law analysis of a variable output 1–4.5 kWe, ICE-driven, natural-gas fueled micro-CHP generator
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Long-term capacity expansion models of the U.S. electricity sector have long been used to inform electric sector stakeholders and decision-makers. With the recent surge in variable renewable energy (VRE) generators — primarily wind and solar photovoltaics — the need to appropriately represent VRE generators in these long-term models has increased. VRE generators are especially difficult to represent for a variety of reasons, including their variability, uncertainty, and spatial diversity. This report summarizes the analyses and model experiments that were conducted as part of two workshops on modeling VRE for national-scale capacity expansion models. It discusses the various methods for treating VRE among four modeling teams from the Electric Power Research Institute (EPRI), the U.S. Energy Information Administration (EIA), the U.S. Environmental Protection Agency (EPA), and the National Renewable Energy Laboratory (NREL). The report reviews the findings from the two workshops and emphasizes the areas where there is still need for additional research and development on analysis tools to incorporate VRE into long-term planning and decision-making. This research is intended to inform the energy modeling community on the modeling of variable renewable resources, and is not intended to advocate for or against any particular energy technologies, resources, or policies.
We propose an experimentally feasible scheme to produce bright quadricolor continuous-variable (CV) entanglement by a four-wave mixing process (FWM) with four-level atoms inside the optical ring cavities operating above threshold. The Stokes and anti-Stokes beams are generated via the pump beam (tuned close to one atomic transition) and the coupling beam (tuned to the resonance of another atomic transition), respectively. The quadruply resonant and narrowed linewidth of the cavity fields with different frequencies are achieved and quadricolor CV entanglement among the four cavity fields is demonstrated according to the criterion proposed by van Loock and Furusawa [Phys. Rev. A 67, 052315 (2003)]. This scheme provides a way to generate bright quadricolor CV entanglement and will be significant for applications in quantum information processing and quantum networks.
We examine the feasibility of generating continuous-variable multipartite entanglement in an intracavity concurrent downconversion scheme that has been proposed for the generation of cluster states by Menicucci et al. [Phys. Rev. Lett. 101, 130501 (2008)]. By calculating optimized versions of the van Loock-Furusawa correlations we demonstrate genuine quadripartite entanglement and investigate the degree of entanglement present. Above the oscillation threshold the basic cluster state geometry under consideration suffers from phase diffusion. We alleviate this problem by incorporating a small injected signal into our analysis. Finally, we investigate squeezed joint operators. While the squeezed joint operators approach zero in the undepleted regime, we find that this is not the case when we consider the full interaction Hamiltonian and the presence of a cavity. In fact, we find that the decay of these operators is minimal in a cavity, and even depletion alone inhibits cluster state formation.
Features of existing wholesale electricity markets, such as administrative pricing rules and policy-based reliability standards, can distort market incentives from allowing generators sufficient opportunities to recover both fixed and variable costs. Moreover, these challenges can be amplified by other factors, including (1) inelastic demand resulting from a lack of price signal clarity, (2) low- or near-zero marginal cost generation, particularly arising from low natural gas fuel prices and variable generation (VG), such as wind and solar, and (3) the variability and uncertainty of this VG. As power systems begin to incorporate higher shares of VG, many questions arise about the suitability of the existing marginal-cost-based price formation, primarily within an energy-only market structure, to ensure the economic viability of resources that might be needed to provide system reliability. This article discusses these questions and provides a summary of completed and ongoing modelling-based work at the National Renewable Energy Laboratory to better understand the impacts of evolving power systems on reliability and revenue sufficiency.
Features of existing wholesale electricity markets, such as administrative pricing rules and policy-based reliability standards, can distort market incentives from allowing generators sufficient opportunities to recover both fixed and variable costs. Moreover, these challenges can be amplified by other factors, including (1) inelastic demand resulting from a lack of price signal clarity, (2) low- or near-zero marginal cost generation, particularly arising from low natural gas fuel prices and variable generation (VG), such as wind and solar, and (3) the variability and uncertainty of this VG. As power systems begin to incorporate higher shares of VG, many questions arise about the suitability of the existing marginal-cost-based price formation, primarily within an energy-only market structure, to ensure the economic viability of resources that might be needed to provide system reliability. This article discusses these questions and provides a summary of completed and ongoing modelling-based work at the National Renewable Energy Laboratory to better understand the impacts of evolving power systems on reliability and revenue sufficiency.
The relative importance of ocean and atmospheric dynamics in generating Atlantic Multidecadal Variability (AMV) remains an open question. Comparisons between climate models with SLAB and fully-dynamic (FULL) ocean components are often used to explore this question, but cannot reveal how individual ocean processes generate these differences. We build a hierarchy of physically interpretable stochastic models to investigate the contribution of two upper-ocean processes to AMV: the role of seasonal variation and mixed-layer entrainment. This interpretability arises from the stochastic model’s simplified representation of sea surface temperature (SST), considering only the local upper ocean response to white-noise atmospheric forcing and its impact on surface heat exchange. We focus on understanding differences between SLAB and FULL non-eddy resolving pre-industrial control simulations of the Community Earth System Model 1 (CESM), and estimate the stochastic model parameters from each respective simulation. Despite its simplicity, the stochastic model reproduces temporal characteristics of SST variability in the SPG, including reemergence, seasonal-to-interannual persistence and power spectra. Furthermore, unrealistically persistent SST of the CESM-SLAB ocean simulation is reproduced in the equivalent stochastic model configuration where the mixed-layer depth (MLD) is constant. The stochastic model also reveals that vertical entrainment primarily damps SST variability, thus explaining why SLAB exhibits larger SST variance than FULL. Here, the stochastic model driven by temporally stochastic, spatially coherent forcing patterns reproduces the canonical AMV pattern. However, the amplitude of low-frequency variability remains underestimated, suggesting a role for ocean dynamics beyond entrainment.
Voltage control devices are employed in power distribution systems to reduce the power consumption by operating the system closer to the lower acceptable voltage limits; this technique is called conservation voltage reduction (CVR). The different modes of operation for system’s legacy devices (with binary control) and new devices (e.g. smart inverters with continuous control) coupled with variable photovoltaic (PV) generation results in voltage fluctuations which makes it challenging to achieve CVR objective. This paper presents a two-timescale control of feeder’s voltage control devices to achieve CVR that includes (1)a centralized controller operating in a slower time-scale to coordinate voltage control devices across the feeder and (2) local controllers operating in a faster timescale to mitigate voltage fluctuations due to PV variability. The centralized controller utilizes a three-phase optimal power flow model to obtain the decision variables for both legacy devices and smart inverters. The local controllers operate smart inverters to minimize voltage fluctuations and restore nodal voltages to their reference values by adjusting the reactive power support. The proposed approach is validated using the IEEE-123 bus (medium-size) and R3-12.47-2 (large-size) feeders. It is demonstrated that the proposed approach is effective in achieving the CVR objective for unbalanced distribution systems.
Here, we present the near-Maximal Algorithm for Poisson-disk Sampling (nMAPS) to generate point distributions for variable resolution Delaunay triangular and tetrahedral meshes in two and three-dimensions, respectively. nMAPS consists of two principal stages. In the first stage, an initial point distribution is produced using a cell-based rejection algorithm. In the second stage, holes in the sample are detected using an efficient background grid and filled in to obtain a near-maximal covering. Extensive testing shows that nMAPS generates a variable resolution mesh in linear run time with the number of accepted points. We demonstrate nMAPS capabilities by meshing three-dimensional discrete fracture networks (DFN) and the surrounding volume. The discretized boundaries of the fractures, which are represented as planar polygons, are used as the seed of 2D-nMAPS to produce a conforming Delaunay triangulation. The combined mesh of the DFN is used as the seed for 3D-nMAPS, which produces conforming Delaunay tetrahedra surrounding the network. Under a set of conditions that naturally arise in maximal Poisson-disk samples and are satisfied by nMAPS, the two-dimensional Delaunay triangulations are guaranteed to only have well-behaved triangular faces. While nMAPS does not provide triangulation quality bounds in more than two dimensions, we found that low-quality tetrahedra in 3D are infrequent, can be readily detected and removed, and a high-quality balanced mesh is produced.
The EPREP code is designed to evaluate the effects of an Electro-Magnetic Pulse (EMP) on the electric power transmission system. The EPREP code embodies an umbrella framework that allows a user to set up analysis conditions and to examine analysis results. The code links to three major physics/engineering modules. The first module describes the EM wave in space and time. The second module evaluates the damage caused by the wave on specific electric power (EP) transmission system components. The third module evaluates the consequence of the damaged network on its (reduced) ability to provide electric power to meet demand. This third module is the focus of the present paper. The EMPACT code serves as the third module. The EMPACT name denotes EMP effects on Alternating Current Transmission systems. The EMPACT algorithms compute electric power transmission network flow solutions under severely damaged network conditions. Initial solutions are often characterized by unacceptible network conditions including line overloads and bad voltages. The EMPACT code contains algorithms to adjust optimally network parameters to eliminate network problems while minimizing outages. System adjustments include automatically adjusting control equipment (generator V control, variable transformers, and variable shunts), as well as non-automatic control of generator power settings and minimal load shedding. The goal is to evaluate the minimal loss of customer load under equilibrium (steady-state) conditions during peak demand.
Geothermal power plants are a reliable source of low-carbon power generation. However, modern electricity markets comprise relatively large proportions of variable renewable energy generation that may require power plants to dispatch energy flexibly. The power output, efficiency, and dispatch flexibility of a geothermal plant can be enhanced by integrating solar thermal energy into the system, as well as possibly compensating against ambient temperature variations. Concentrating Solar Thermal (CST) can generate temperatures much higher than conventional geothermal systems. Using a solar topping cycle is one way to efficiently convert high-temperature solar heat to electricity while also adding lower-temperature heat to the geothermal power cycle, thereby increasing its power output and possibly its efficiency. A hybrid power cycle design is proposed and is simulated using SimTech IPSEpro process modelling software. The design configuration depends upon the expected temperature of the geothermal resource and the quantity of solar heat added at the design point. These design considerations are described and expected performance is calculated. The solar heat addition varies throughout the day and year, therefore off-design models are necessary to assess the impact of solar availability (and ambient temperature) on the power plant performance. Off-design models are developed and combined with hourly weather data to facilitate an evaluation of annual system performance.
Geothermal power plants are a reliable source of low-carbon power generation. However, modern electricity markets comprise relatively large proportions of variable renewable energy generation that may require power plants to flexibly dispatch energy. The power output, efficiency, and dispatch flexibility of a geothermal plant can be enhanced by integrating solar thermal energy into the system, as well as possibly compensating against ambient temperature variations. Concentrating solar thermal (CST) can generate temperatures much higher than conventional geothermal systems. Using a solar topping cycle is one way to efficiently convert high-temperature solar heat to electricity while also cascading lower-temperature heat to the geothermal power cycle, thereby increasing its power output and possibly its efficiency. A hybrid power cycle design is proposed and simulated using SimTech IPSEpro process modeling software. The design configuration depends on the expected temperature of the geothermal resource and the quantity of solar heat added at the design point. These design considerations are described and expected performance is calculated. The solar heat addition varies throughout the day and year; therefore, off-design models are necessary to assess the impact of solar availability (and ambient temperature) on the power plant performance. Off-design models are developed and combined with hourly weather data to facilitate an evaluation of annual system performance.
The annual retirement of U.S. coal-fired electricity generation units (CF-EGU) is at an all-time high and is expected to continue. This loss of reliable baseload generation, combined with predicted growth of variable renewable energy (VRE) generation, is expected to stress grid reliability as the number of load-following resources drops below the experienced load variability. Many regions are already experiencing challenges, and fossil retirement-related warnings by the North American Electric Reliability Corp. are becoming more dire. All CF-EGU retirements pose significant challenges to asset owners, local workforces, and their communities. Repurposing a retiring CF-EGU as a long-duration energy storage plant can address these challenges and offer a suite of additional benefits to asset owners, the grid, and society. This project performed a techno-economic evaluation and assessment of repurposing a Duke Energy fossil-fueled asset (in particular, a coal plant) into an energy storage system by integrating the retiring asset with a Malta long duration Pumped Heat Energy Storage (PHES) system. The project validated the technoeconomic benefits of repurposing retiring coal plants into long-duration energy storage using Malta’s PHES. Key findings for this project are summarized below: (1) Technical: (a) Retiring coal plants (and other steam turbine fossil generation) can be repurposed to enable the clean energy transition using Malta’s technology. (b) For older retiring coal plants, repurposing the site and electrical interconnection for a standalone PHES plant is the most economically favorable option. (c) For newer coal plants where there is also a local peaking capacity need, repowering the steam cycle into a hybrid integration with PHES is attractive. (d) A process was developed to assist fossil generation owners in choosing the best path for each plant’s circumstances. (2) Economic (a) Communities facing economic challenges caused by the retirement of fossil generation would benefit from repurposing the plant as long-duration energy storage using Malta’s PHES. (b) On a $/MW basis, repowering retiring coal units into Malta PHES plants can maintain the same number and types of jobs and economic activity. (c) For a 70% carbon reduction scenario, a 10-hour Malta PHES plant is more economic for the asset owner than similar-power 4-hour batteries. This project showed that repurposing a retiring coal unit into thermal energy storage, by integrating it with a Malta PHES system, makes techno-economic sense. At least two integration options are available, with the optimal solution depending on the coal plant and its location. Repurposing retiring coal plant into energy storage results in economic benefits for the plant owner and local communities.
We are witnessing an acceleration in the uptake of renewable energy in power systems. Because of the associated variability and uncertainty of renewables, power systems need to have an adequate supply of flexibility to allow for suitable management of short-term operations. So far most of the work in this area has neglected how flexibility needs associated with renewables are fulfilled as part of dispatchable generation capital investments decisions. To address this challenge, we propose an approach to plan the dispatchable generation mix of a power system as needed to counteract variability and uncertainty associated with significant shares of variable renewable generation. The approach exploits the linear time-invariant feature of variable generation variability using historical phase planes of capacity (in MW) and ramp (in MW/min) to bridge the gap between long-term capacity planning and short-term intra-hour flexibility needs. This approach is much more computationally tractable than other proposals, while also being able to capture adequately short-term operational features like ramping and net load variability. Numerical tests are performed on realistic datasets to substantiate the effectiveness of the approach.
This document is a poster covering the findings from activities on training data generation, specifically geologic ensemble generation. The generated geologic realizations captured the range of possible permeability distributions of the subsurface at the Illinois Basin - Decatur Project (IBDP) site, based on available well log variabilities. The percentages of reservoirs and baffles in the injection zone and a truncation of baffle permeability led to more variance in the simulations. This will be used to build forward modeling, history matching, and optimization workflows. The geologic realizations were also ranked according to dynamic measures of hydraulic diffusivity, and simulations confirm a greater contrast between the reservoir and the baffles during injection.
A new generation of full variable-capacity, central, ducted air-conditioning (AC) and heat pump units has come on the market, and they promise to deliver increased cooling (and heating) efficiency. They are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they can vary their capacity over a wide range (approximately 40% to 118% of nominal full capacity), thus staying “on” for up to twice as many hours per day compared to fixed-capacity systems of the same nominal capacity. The heating and cooling capacity is varied by adjusting the indoor fan air flow rate, compressor, and refrigerant flow rate as well as the outdoor unit fan air flow rate. Note that two-stage AC or heat pump systems were not evaluated in this research effort. The term dwell is used to refer to the amount of time distributed air spends inside ductwork during space-conditioning cycles. Longer run times mean greater dwell time and therefore greater exposure to conductive gains and losses.
A new generation of full variable-capacity, central, ducted air-conditioning (AC) and heat pump units has come on the market, and they promise to deliver increased cooling (and heating) efficiency. They are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they can vary their capacity over a wide range (approximately 40% to 118% of nominal full capacity), thus staying “on” for up to twice as many hours per day compared to fixed-capacity systems of the same nominal capacity. The heating and cooling capacity is varied by adjusting the indoor fan air flow rate, compressor, and refrigerant flow rate as well as the outdoor unit fan air flow rate. Note that two-stage AC or heat pump systems were not evaluated in this research effort. The term dwell is used to refer to the amount of time distributed air spends inside ductwork during space-conditioning cycles. Longer run times mean greater dwell time and therefore greater exposure to conductive gains and losses.
The name SuperOPF is used to refer several projects, problem formulations and soft-ware tools intended to extend, improve and re-define some of the standard methods of optimizing electric power systems. Our work included applying primal-dual interior point methods to standard AC optimal power flow problems of large size, as well as extensions of this problem to include co-optimization of multiple scenarios. The original SuperOPF problem formulation was based on co-optimizing a base scenario along with multiple post-contingency scenarios, where all AC power flow models and constraints are enforced for each, to find optimal energy contracts, endogenously determined locational reserves and appropriate nodal energy prices for a single period optimal power flow problem with uncertainty. This led to example non-linear programming problems on the order of 1 million constraints and half a million variables. The second generation SuperOPF formulation extends this by adding multiple periods and multiple base scenarios per period. It also incorporates additional variables and constraints to model load following reserves, ramping costs, and storage resources. A third generation of the multi-period SuperOPF, adds both integer variables and a receding horizon framework in which the problem type is more challenging (mixed integer), the size is even larger, and it must be solved more frequently, pushing the limits of currently available algorithms and solvers. The consideration of transient stability constraints in optimal power flow (OPF) problems has become increasingly important in modern power systems. Transient stability constrained OPF (TSCOPF) is a nonlinear optimization problem subject to a set of algebraic and differential equations. Solving a TSCOPF problem can be challenging due to (i) the differential-equation constraints in an optimization problem, (ii) the lack of a true analytical expression for transient stability in OPF. To handle the dynamics in TSCOPF, the set of differential equations can be approximated or converted into equivalent algebraic equations before they are included in an OPF formulation. In Chapter 4, a rigorous evaluation of using a predefined and fixed threshold for rotor angles as a mean to determine transient stability of the system is developed. TSCOPF can be modeled as a large-scale nonlinear programming problem including the constraints of differential-algebraic equations (DAE). Solving a TSCOPF problem can be challenging due to (i) the differential-equation constraints in an optimization problem, (ii) the lack of a true analytical expression for transient stability constraint in OPF. Unfortunately, even the current best TSCOPF solvers still suffer from the curse of dimensionality and unacceptable computational time, especially for large-scale power systems with multiple contingencies. In chapter 5, thse issues will be addressed and a new method to incorporate the transient stability constraints will be presented.