Search NASA⌕ Search

SEARCH · Search NASA

Results for “2 column instrument”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Airborne MAX-DOAS Measurements Over California: Testing the NASA OMI Tropospheric NO2 Product

Airborne Multi-AXis Differential Optical Absorption Spectroscopy (AMAX-DOAS) measurements of NO2 tropospheric vertical columns were performed over California for two months in summer 2010. The observations are compared to the NASA Ozone Monitoring Instrument (OMI) tropospheric vertical columns (data product v2.1) in two ways: (1) Median data were compared for the whole time period for selected boxes, and the agreement was found to be fair (R = 0.97, slope = 1.4 +/- 0.1, N= 10). (2) A comparison was performed on the mean of coincident AMAX-DOAS measurements within the area of the corresponding OMI pixels with the tropospheric NASA OMI NO2 assigned to that pixel. The effects of different data filters were assessed. Excellent agreement and a strong correlation (R = 0.85, slope = 1.05 +/- 0.09, N= 56) was found for (2) when the data were filtered to eliminate large pixels near the edge of the OMI orbit, the cloud radiance fraction was<50%, the OMI overpass occurred within 2 h of the AMAX-DOAS measurements, the flight altitude was>2 km, and a representative sample of the footprint was taken by the AMAX-DOAS instrument. The AMAX-DOAS and OMI data sets both show a reduction of NO2 tropospheric columns on weekends by 38 +/- 24% and 33 +/- 11%, respectively. The assumptions in the tropospheric satellite air mass factor simulations were tested using independent measurements of surface albedo, aerosol extinction, and NO2 profiles for Los Angeles for July 2010 indicating an uncertainty of 12%.

remote sensing↗

Gas Chromatograph Method Optimization Trade Study for RESOLVE: 20-meter Column v. 8-meter Column

RESOLVE is the payload on a Class D mission, Resource Prospector, which will prospect for water and other volatile resources at a lunar pole. The RESOLVE payload's primary scientific purpose includes determining the presence of water on the moon in the lunar regolith. In order to detect the water, a gas chromatograph (GC) will be used in conjunction with a mass spectrometer (MS). The goal of the experiment was to compare two GC column lengths and recommend which would be best for RESOLVE's purposes. Throughout the experiment, an Inficon Fusion GC and an Inficon Micro GC 3000 were used. The Fusion had a 20m long column with 0.25mm internal diameter (Id). The Micro GC 3000 had an 8m long column with a 0.32mm Id. By varying the column temperature and column pressure while holding all other parameters constant, the ideal conditions for testing with each column length in their individual instrument configurations were determined. The criteria used for determining the optimal method parameters included (in no particular order) (1) quickest run time, (2) peak sharpness, and (3) peak separation. After testing numerous combinations of temperature and pressure, the parameters for each column length that resulted in the most optimal data given my three criteria were selected. The ideal temperature and pressure for the 20m column were 95 C and 50psig. At this temperature and pressure, the peaks were separated and the retention times were shorter compared to other combinations. The Inficon Micro GC 3000 operated better at lower temperature mainly due to the shorter 8m column. The optimal column temperature and pressure were 70 C and 30psig. The Inficon Micro GC 3000 8m column had worse separation than the Inficon Fusion 20m column, but was able to separate water within a shorter run time. Therefore, the most significant tradeoff between the two column lengths was peak separation of the sample versus run time. After performing several tests, it was concluded that better detection via good peak separation with a longer run time is a better asset than moderate peak separation with a shorter run time. Even given that RESOLVE is highly interested in water and that mission timeline is of significant importance given the short seven-to-ten-day mission timeline, worse detection with an 8m column may lead to overlooking other substances existing on the moon that could advance planetary science. Thus, I recommend the 20m column. However, if mission timeline and water separation are deemed the highest priority, the 8m column should be selected due to its ability to separate water within a shorter run time than the 20m column.

Column↗

Evaluation of the Stratospheric and Tropospheric Bromine Burden over Fairbanks, Alaska Based on Column Retrievals of Bromine Monoxide

In spring 2011, columns of bromine monoxide (BrO) were retrieved over Fairbanks, Alaska using a ground-based multifunction differential optical absorption spectroscopy (MFDOAS) instrument. MFDOAS vertical column BrO is consistently lower than retrievals from the satellite-based Ozone Monitoring Instrument (OMI), with a relative bias of 20 ± 14%. Numerous tropical-based studies suggest that 5 ± 2 ppt of bromine from very short-lived substances (VSLS) reaches the stratosphere. We evaluate upper limits on the contribution of VSLS to stratospheric bromine by treating the column retrievals of BrO as purely stratospheric and modeling the ratio of BrO to total inorganic bromine. The OMI and MFDOAS retrievals respectively present 8 and 5 ppt upper limits on the stratospheric injection of VSLS, and kinetic uncertainties in the daytime partitioning of bromine species decrease both values by ~1.6 ppt. The OMI-based estimate is in agreement with the 5 ppt tropical-based value for stratospheric injection of VSLS if the tropospheric column of BrO is 1.5 × 10(exp 13) molecules/cu. cm over Fairbanks, which is within the range of uncertainty of a second ground-based instrument that monitored tropospheric BrO during the campaign. Because our ground-based instruments detected no BrO near the surface, this value for tropospheric BrO would originate from the free troposphere and is in agreement with previous retrievals of background tropospheric BrO. Our calculations of tropospheric BrO over Fairbanks are most sensitive to uncertainties in the stratospheric loading of VSLS, followed by the difference between the OMI and MFDOAS retrievals of BrO.

Pamela A. Wales↗

Evaluation of SO2, SO4(2−) and an Updated SO2 Dry Deposition Parameterization in the United Kingdom Earth System Model

In this study we evaluate simulated surface SO2 and sulphate (SO4(2-)) concentrations from the United Kingdom Earth System Model (UKESM1) against observations from ground based measurement networks in the USA and Europe for the period 1987 to 2014. We find that UKESM1 captures the historical trend for decreasing concentrations of atmospheric SO2 and SO4(2-) in both Europe and the USA over the period 1987 to 2014. However, in the polluted regions of the eastern USA and Europe, UKESM1 over-predicts surface SO2 concentrations by a factor of 3, while under-predicting surface SO4(2-) concentrations by 25-35%. In the cleaner western USA, the model over-predicts both surface SO2 and SO4(2-) concentrations by a factor of 12 and 1.5 respectively. We find that UKESM1’s bias in surface SO2 and SO4(2-) concentrations is variable according to region and season. We also evaluate UKESM1 against total column SO2 from the Ozone Monitoring Instrument (OMI) using an updated data product. This comparison provides information about the model’s global performance, finding that UKESM1 over predicts total column SO2 over much of the globe, including the large source regions of India, China, the USA and Europe as well as over outflow regions. Finally, we assess the impact of a more realistic treatment of the model’s SO2 dry deposition parameterization. This change increases SO2 dry deposition to the land and ocean surfaces, thus reducing the atmospheric loading of SO2 and SO(sup 2-)(sub 4). In comparison with the ground-based and satellite observations, we find that the modified parameterization reduces the models over prediction of surface SO2 concentrations and total column SO2. Relative to the ground-based observations the simulated surface SO4(2-) concentrations are also reduced, while the simulated SO2 dry deposition fluxes increase.

SO2↗

Satellite Gravimetry Applied to Drought Monitoring

Near-surface wetness conditions change rapidly with the weather, which limits their usefulness as drought indicators. Deeper stores of water, including root-zone soil wetness and groundwater, portend longer-term weather trends and climate variations, thus they are well suited for quantifying droughts. However, the existing in situ networks for monitoring these variables suffer from significant discontinuities (short records and spatial undersampling), as well as the inherent human and mechanical errors associated with the soil moisture and groundwater observation. Remote sensing is a promising alternative, but standard remote sensors, which measure various wavelengths of light emitted or reflected from Earth's surface and atmosphere, can only directly detect wetness conditions within the first few centimeters of the land s surface. Such sensors include the Advanced Microwave Scanning Radiometer - Earth Observing System (AMSR-E) C-band passive microwave measurement system on the National Aeronautic and Space Administration's (NASA) Aqua satellite, and the combined active and passive L-band microwave system currently under development for NASA's planned Soil Moisture Active Passive (SMAP) satellite mission. These instruments are sensitive to water as deep as the top 2 cm and 5 cm of the soil column, respectively, with the specific depth depending on vegetation cover. Thermal infrared (TIR) imaging has been used to infer water stored in the full root zone, with limitations: auxiliary information including soil grain size is required, the TIR temperature versus soil water content curve becomes flat as wetness increases, and dense vegetation and cloud cover impede measurement. Numerical models of land surface hydrology are another potential solution, but the quality of output from such models is limited by errors in the input data and tradeoffs between model realism and computational efficiency. This chapter is divided into eight sections, the next of which describes the theory behind satellite gravimetry. Following that is a summary of the GRACE mission and how hydrological information is gleaned from its gravity products. The fourth section provides examples of hydrological science enabled by GRACE. The fifth and sixth sections list the challenging aspects of GRACE derived hydrology data and how they are being overcome, including the use of data assimilation. The seventh section describes recent progress in applying GRACE for drought monitoring, including the development of new soil moisture and drought indicator products, and that is followed by a discussion of future prospects in satellite gravimetry based drought monitoring.

Rodell, Matthew↗

White Paper on SBUV/2 Solar Irradiance Measurements

The importance of solar irradiance measurements by the Solar Backscatter Ultraviolet, Model 2 (SBUV/2) instruments on NOAA's operational satellites is described. These measurements are necessary accurately monitor the long-term changes in the global column ozone amount, the altitude distribution of ozone in the upper stratosphere, and the degree to which ozone changes are caused by anthropogenic sources. Needed to accomplish these goals are weekly solar irradiance measurements at the operational ozone wavelengths, daily measurements of the Mg II proxy index, instrument-specific Mg II scale factors, and daily measurements of the solar spectral irradiance at photochemically important wavelengths. Two solar measurement schedules are provided: (1) a baseline schedule for all instruments except the NOAA-14 instrument and (2) a modified schedule for the NOAA-14 SBUV/2 instrument. This latter schedule is needed due to the NOAA-14 grating drive problems.

Hilsenrath, Ernest↗

Derivation of Tropospheric Ozone Climatology and Trends from TOMS Data

This research addresses the following three objectives: (1) Derive tropospheric ozone columns from the TOMS instruments by computing the difference between total-ozone columns over cloudy areas and over clear areas in the tropics; (2) Compute secular trends in Nimbus-7 derived tropospheric Ozone column amounts and associated potential trends in the decadal-scale tropical cloud climatology; (3) Explain the occurrence of anomalously high ozone retrievals over high ice clouds.

Newchurch, Michael J.↗

The Climatology of Carbon Monoxide and Water Vapor on Mars as Observed by CRISM and Modeled by the GEM-Mars General Circulation Model

Radiative transfer modeling of near-infrared spectra taken by the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) instrument onboard Mars Reconnaissance Orbiter (MRO) enables the column-integrated abundance of carbon monoxide (CO) and water vapor (H 2 O) to be retrieved. These results provide a detailed global description of the seasonal and spatial distribution of CO in the Mars atmosphere and new information about the interannual variability of H2O. The CRISM retrievals show the seasonally and globally averaged carbon monoxide mixing ratio to be near 800 parts per million, but with strong seasonal variations, especially at high latitudes. At low latitudes, the carbon monoxide mixing ratio varies in response to the mean seasonal cycle of surface pressure and shows little variation with topography. At high latitudes, carbon monoxide is depleted in the summer hemisphere by a factor of two or more, while in the winter hemisphere there is relatively higher mixing ratio in regions with low-lying topography. Water vapor shows only modest interannual variations, with the largest observed difference being unusually dry conditions in the wake of the Mars Year 28 global dust storm. Modeling results from the GEM (Global Environmental Multiscale) - Mars general circulation model generally reproduce the observed seasonal and spatial trends and provide insight into the underlying physical processes.

Smith, Michael D.↗

Establishing Calibration Standards for Remote Sensing Retrievals of Greenhouse Gases

While in situ greenhouse gas measurements have a concrete calibration standard, establishing a similar standard for remote sensing retrievals remains challenging. As the constellation of greenhouse gas observing satellites grows, such a standard is essential to ensure data are of the quality necessary to support scientific and policy applications. A primary goal of NASA's Atmospheric Carbon and Transport (ACT) - America aircraft campaign is to evaluate column CO2 retrievals from the Orbiting Carbon Observatory 2 (OCO-2) through coordinated underflights. The campaign also includes airborne lidar instruments that measure the amount of CO2 and CH4 below the aircraft. This presentation introduces a system that establishes calibration standards for OCO-2 and lidar retrievals based on in situ data from the ACT-America campaign. The system assimilates the in situ data into NASA's Goddard Earth Observing System (GEOS) to produce high-resolution, two-dimensional transects of CO2 along the flight path which we refer to as curtains. Excluding the ability to sample the entire atmosphere at once, any such analysis must make assumptions about the connection of measurements at different places and times to a given retrieval. We chose to use the GEOS general circulation model forced by meteorology from its data assimilation system because their scientific merits are extensively documented. Furthermore, in areas rich in data, the assimilated curtains approach a field constrained by data alone. Where data are lacking, e.g., the stratosphere, age of air and other transport diagnostics can be used to quantify the uncertainty introduced by the model. Given these uncertainties, we can determine the uncertainties of the curtains and thus our ability to evaluate remote sensing instruments. Here, we demonstrate this for several flights over North America and discuss possible applications to upcoming missions, e.g., GeoCarb.

Weir, B.↗

Hyperspectral Sun Photometer for Atmospheric Characterization and Vicarious Calibrations

A hyperspectral sun photometer and associated methods have been developed and demonstrated. Accurate sun photometer calibration is critical to properly measure the solar irradiance and characterize the atmosphere. Traditional sun photometer calibration requires solar observations over several hours. In contrast, the procedures for operating this photometer entail less data acquisition time and embody a more direct approach to calibration. The scientific value of the measurement data produced by this instrument is not adversely affected by atmospheric instability. In addition, this instrument yields hyperspectral data covering a large spectral range (350-2,500 nm) not available from most traditional sun photometers. The hyperspectral sun photometer components include (1) a commercially available spectroradiometer that has been laboratory-calibrated and (2) a commercially available reflectance standard panel that exhibits nearly Lambertian 99% reflectance. The spectroradiometer is positioned above, and aimed downward at, the panel. The procedure for operating this instrument calls for a series of measurements: one in which the panel is fully illuminated by the sun, one in which a shade is positioned between the panel and the sun, and two in which the shade is positioned to cast a shadow to either side of the panel. The total sequence of measurements can be performed in less than a minute. From these measurements, the total radiance, the diffuse radiance, and the direct solar radiance are calculated. The direct solar irradiance is calculated from the direct solar radiance and the known reflectance factor of the panel as a function of the solar zenith angle. Atmospheric characteristics are estimated from the optical depth at various wavelengths calculated from (1) the direct solar irradiance obtained as described above, (2) the air mass along a column from the measurement position to the Sun, and (3) the top-of-atmosphere solar irradiance. The instrumentation used to implement the sun photometer is the same as that used to characterize targets used in radiometric vicarious calibrations. Utilizing this type of sun photometer thus reduces the amount of instrumentation and labor required to perform these studies.

Pagnutti, Mary↗

TPSAS-NF1676L-10746-DND

This paper presents the design, development, and field testing of a high sensitivity ground-based Differential Absorption Lidar (DIAL) system that was developed under the NASA Instrument Incubator Program. The investigation presents a significant advancement towards the development of future CO2 profiling capability as it incorporates key elements of technologies needed for a future development of global CO2 measuring systems including: (1) 2-μm laser technologies that have been developed under a number of NASA programs including the Laser Risk Reduction Program (LRRP) (2) A novel high quantum efficiency (QE), high gain (without excess noise factor), and low noise phototransistor, and (3) Direct detection DIAL system using a large collection area receiver that is insensitive to speckle and coherence length effects from atmospheric turbulence that influences heterodyne detection systems. The objective of the project was a system TRL of 4, and the goal was TRL 5. Development and testing of the laser, new detector, and receiver systems during the project, integration into a complete lidar system into a trailer, field testing of system at West Branch, IA and comparison of the lidar CO2 measurements with in situ sensors advanced the system to a TRL of 5. The system demonstrated high vertical resolution CO2 profiling capability within the boundary layer and column measurements to long ranges. This is the first direct detection demonstration of a 2-micron CO2 DIAL high vertical resolution capability from instrument concept to field demonstration.

Syed Ismail↗

Southern Hemisphere Additional Ozonesondes (SHADOZ) Ozone Climatology (2005-2009): Tropospheric and Tropical Tropopause Layer (TTL) Profiles with Comparisons to Omi-based Ozone Products

We present a regional and seasonal climatology of SHADOZ ozone profiles in the troposphere and tropical tropopause layer (TTL) based on measurements taken during the first five years of Aura, 2005-2009, when new stations joined the network at Hanoi, Vietnam; Hilo, Hawaii; Alajuela Heredia, Costa Rica; Cotonou, Benin. In all, 15 stations operated during that period. A west-to-east progression of decreasing convective influence and increasing pollution leads to distinct tropospheric ozone profiles in three regions: (1) western Pacific eastern Indian Ocean; (2) equatorial Americas (San Cristobal, Alajuela, Paramaribo); (3) Atlantic and Africa. Comparisons in total ozone column from soundings, the Ozone Monitoring Instrument (OMI, on Aura, 2004-) satellite and ground-based instrumentation are presented. Most stations show better agreement with OMI than they did for EPTOMS comparisons (1998-2004; Earth-ProbeTotal Ozone Mapping Spectrometer), partly due to a revised above-burst ozone climatology. Possible station biases in the stratospheric segment of the ozone measurement noted in the first 7 years of SHADOZ ozone profiles are re-examined. High stratospheric bias observed during the TOMS period appears to persist at one station. Comparisons of SHADOZ tropospheric ozone and the daily Trajectory-enhanced Tropospheric Ozone Residual (TTOR) product (based on OMIMLS) show that the satellite-derived column amount averages 25 low. Correlations between TTOR and the SHADOZ sondes are quite good (typical r2 0.5-0.8), however, which may account for why some published residual-based OMI products capture tropospheric interannual variability fairly realistically. On the other hand, no clear explanations emerge for why TTOR-sonde discrepancies vary over a wide range at most SHADOZ sites.

gravity waves↗

Profiles of Reactive Trace Gases over Remote Oceans During ATom

The Atmospheric Tomography (ATom) mission deployed an extensive gas and aerosol payload on the NASA DC-8 aircraft on four campaigns spanning each season. ATom systematically sampled the atmosphere from 0.2 to 12 kilometer altitude, from 85 degrees North Latitude to 65 degrees South Latitude, in both the Pacific and the Atlantic to provide detailed profiles of chemical composition over the remote oceans. We will present profiles of reactive trace species, such as O3, NOx, NOy, HOx, HCHO, and several other short-lived source gases. We will combine these measurements with results from a 0-D box model to show their utility in (1) evaluating gradients in latitude/season, (2) identifying contributions of pollution from long-range and convective transport, and (3) evaluating column measurements from remote sensing satellite instruments.

ISAF↗

TPSAS-NF1676L-11930-DND

Under the NASA Laser Risk Reduction Program (LRRP), funded by Earth Science Technology Office (ESTO), an efficient, injection seeded, high repetition rate Tm:fiber laser pumped Ho:YLF laser has been developed and operation between 100 Hz to 10 kHz has been demonstrated. The work is underway to develop an efficient, high-repetition-rate, pulsed, 2-micron, coherent Differential Absorption Lidar (DIAL) / Integrated Path Differential Absorption (IPDA) instrument for measuring the atmospheric CO2 profiles (DIAL) and column densities (IPDA) from an airborne platform. In DIAL mode, this instrument will provide the first ever range-resolved, high-precision, remote measurements of the CO2 content of the atmospheric boundary layer (ABL) and lower troposphere.

Upendra N Singh↗

Global Distribution and 14-Year Changes in Erythemal Irradiance, UV Atmospheric Transmission, and Total Column Ozone 2005 – 2018 Estimated from OMI and EPIC Observations

Satellite data from the Ozone Measuring Instrument (OMI) and Earth Polychromatic Imaging Camera (EPIC) are used to study changes and global distribution of UV erythemal irradiance in mW/m(exp 2) E(ζ,φ,z,t) and the dimensionless UV index (E/25 mWm(exp 2)) over the Earth’s surface as a function of latitude ζ, longitude φ, altitude z, and time t. OMI time series data starting in January 2005 to December 2018 are used to estimate 14-year changes in erythemal irradiance, total column ozone TCO3, scene reflectivity LER, and aerosol absorption τA at specific land sites in the Northern and Southern Hemispheres using publicly available OMI data. Estimates of changes in atmospheric transmission ΔCτ(ζ,φ,z,t) derived from OMI measured cloud and haze reflectivity show an increase between 60°S to 45°S almost no average 14-year change from 55°S to 30°N but show an increase from 35°N to 55°N. This implies increased solar insolation at higher latitudes that suggests positive feedback for global warming. Changes in aerosol absorption of UV irradiance ΔCA(ζ,φ,z,t) derived from changes in τA are mostly in the equatorial region and at higher southern latitudes resulting in correlated changes in E. TCO3 derived from OMI data has increased at a rate of 2% per decade for the latitudes between 60°S to 10°N changing to a decrease of 1% per decade between 40°N to 60°N. The result is an average decrease in E(ζ,φ,z,t) at a rate of 2% per decade in the Southern Hemisphere and an increase between 40°N to 60°N. For some specific sites (latitudes from 55°S to 45°N) there has been little or no change in E(ζ,φ,z,t) for the period 2005 – 2018. Nearly half the sites show strong correlation effects of both short- and long-term cloud and absorbing aerosol change as well as anticorrelation with total column ozone change ΔTCO3. Synoptic EPIC data from the sunlit Earth are used to derive ozone and reflectivity needed for global images of the distribution of E(ζ,φ,z,t) from sunrise to sunset centered on the Americas, Europe-Africa, and Asia. EPIC data are used to show the latitudinal distribution of E(ζ,φ,z,t) from the equator to 75° for specific longitudes. Dangerously high amounts of erythemal irradiance (12 < UV index < 18) are found for many low latitude and high-altitude sites (e.g., San Pedro, Chile (2.45 km), La Paz, Bolivia (3.78 km). Lower UV indices at some equatorial or high-altitude sites (e.g., Quito, Ecuador) are moderated by the presence of persistent cloud effects. High UVI levels (UVI > 6) are also found at most mid-latitude sites during the summer months.

Ozone Measuring Instrument (OMI) and Earth Polychr↗

Characterization of Errors in Satellite-Based HCHO/NO 2 Tropospheric Column Ratios With Respect to Chemistry, Column-to-PBL Translation, Spatial Representation, and Retrieval Uncertainties

The availability of formaldehyde (HCHO) (a proxy for volatile organic compound reactivity) and nitrogen dioxide (NO 2 ) (a proxy for nitrogen oxides) tropospheric columns from ultraviolet–visible (UV–Vis) satellites has motivated many to use their ratios to gain some insights into the near-surface ozone sensitivity. Strong emphasis has been placed on the challenges that come with transforming what is being observed in the tropospheric column to what is actually in the planetary boundary layer (PBL) and near the surface; however, little attention has been paid to other sources of error such as chemistry, spatial representation, and retrieval uncertainties. Here we leverage a wide spectrum of tools and data to quantify those errors carefully. Concerning the chemistry error, a well-characterized box model constrained by more than 500 h of aircraft data from NASA's air quality campaigns is used to simulate the ratio of the chemical loss of HO 2 + RO 2 (LRO x ) to the chemical loss of NO x (LNO x ). Subsequently, we challenge the predictive power of HCHO/NO 2 ratios (FNRs), which are commonly applied in current research, in detecting the underlying ozone regimes by comparing them to LRO x /LNO x . FNRs show a strongly linear (R 2 =0.94) relationship with LRO x /LNO x , but only on the logarithmic scale. Following the baseline (i.e., ln(LRO x /LNO x ) = −1.0 ± 0.2) with the model and mechanism (CB06, r2) used for segregating NO x -sensitive from VOC-sensitive regimes, we observe a broad range of FNR thresholds ranging from 1 to 4. The transitioning ratios strictly follow a Gaussian distribution with a mean and standard deviation of 1.8 and 0.4, respectively. This implies that the FNR has an inherent 20 % standard error (1σ) resulting from not accurately describing the RO x –HO x cycle. We calculate high ozone production rates (PO 3 ) dominated by large HCHO × NO 2 concentration levels, a new proxy for the abundance of ozone precursors. The relationship between PO 3 and HCHO × NO 2 becomes more pronounced when moving towards NO x -sensitive regions due to nonlinear chemistry; our results indicate that there is fruitful information in the HCHO × NO 2 metric that has not been utilized in ozone studies. The vast amount of vertical information on HCHO and NO 2 concentrations from the air quality campaigns enables us to parameterize the vertical shapes of FNRs using a second-order rational function permitting an analytical solution for an altitude adjustment factor to partition the tropospheric columns into the PBL region. We propose a mathematical solution to the spatial representation error based on modeling isotropic semivariograms. Based on summertime-averaged data, the Ozone Monitoring Instrument (OMI) loses 12 % of its spatial information at its native resolution with respect to a high-resolution sensor like the TROPOspheric Monitoring Instrument (TROPOMI) (> 5.5 × 3.5 km 2 ). A pixel with a grid size of 216 km 2 fails at capturing ∼ 65 % of the spatial information in FNRs at a 50 km length scale comparable to the size of a large urban center (e.g., Los Angeles). We ultimately leverage a large suite of in situ and ground-based remote sensing measurements to draw the error distributions of daily TROPOMI and OMI tropospheric NO 2 and HCHO columns. At a 68 % confidence interval (1σ), errors pertaining to daily TROPOMI observations, either HCHO or tropospheric NO 2 columns, should be above 1.2–1.5 × 10 16 molec. cm −2 to attain a 20 %–30 % standard error in the ratio. This level of error is almost non-achievable with the OMI given its large error in HCHO. The satellite column retrieval error is the largest contributor to the total error (40 %–90 %) in the FNRs. Due to a stronger signal in cities, the total relative error (< 50 %) tends to be mild, whereas areas with low vegetation and anthropogenic sources (e.g., the Rocky Mountains) are markedly uncertain (> 100 %). Our study suggests that continuing development in the retrieval algorithm and sensor design and calibration is essential to be able to advance the application of FNRs beyond a qualitative metric.

Amir H. Souri↗

Version 2 of the global catalogue of large anthropogenic and volcanic SO 2 sources and emissions derived from satellite measurements

Sulfur dioxide (SO 2 ) measurements from the Ozone Monitoring Instrument (OMI), Ozone Mapping and Profiler Suite (OMPS), and TROPOspheric Monitoring Instrument (TROPOMI) satellite spectrometers were used to update and extend the previously developed global catalogue of large SO 2 emission sources. This version 2 of the global catalogue covers the period of 2005–2021 and includes a total of 759 continuously emitting point sources releasing from about 10 kt yr −1 to more than 4000 kt yr −1 of SO 2 , that have been identified and grouped by country and primary source origin: volcanoes (106 sources); power plants (477); smelters (74); and sources related to the oil and gas industry (102). There are several major improvements compared to the original catalogue: it combines emissions estimates from three satellite instruments instead of just OMI, uses a new version 2 of the OMI and OMPS SO 2 dataset, and updated consistent site-specific air mass factors (AMFs) are used to calculate SO 2 vertical column densities (VCDs). The newest TROPOMI SO 2 data processed with the Covariance-Based Retrieval Algorithm (COBRA), used in the catalogue, can detect sources with emissions as low as 8 kt yr −1 (in 2018–2021) compared to the 30 kt yr −1 limit for OMI. In general, there is an overall agreement within ±12 % in total emissions estimated from the three satellite instruments for large regions. For individual emission sources, the spread is larger: the annual emissions estimated from OMI and TROPOMI agree within ±13 % in 50 % of cases and within ±28 % in 90 % of cases. The version 2 catalogue emissions were calculated as a weighted average of emission estimates from the three satellite instruments using an inverse-variance weighting method. OMI, OMPS, and TROPOMI data contribute 7 %, 5 %, and 88 % to the average, respectively, for small (<30 kt yr −1 ) sources and 33 %, 20 %, and 47 %, respectively, for large (>300 kt yr −1 ) sources. The catalogue data show an approximate 50 % decline in global SO 2 emissions between 2005 and 2021, although emissions were relatively stable during the last 3 years. The version 2 of the global catalogue has been posted at the NASA global SO 2 monitoring website (https://doi.org/10.5067/MEASURES/SO2/DATA406, Fioletov et al., 2022).

volcanic↗

High Precision, Absolute Total Column Ozone Measurements from the Pandora Spectrometer System: Comparisons with Data from a Brewer Double Monochromator and Aura OMI

We present new, high precision, high temporal resolution measurements of total column ozone (TCO) amounts derived from ground-based direct-sun irradiance measurements using our recently deployed Pandora single-grating spectrometers. Pandora's small size and portability allow deployment at multiple sites within an urban air-shed and development of a ground-based monitoring network for studying small-scale atmospheric dynamics, spatial heterogeneities in trace gas distribution, local pollution conditions, photochemical processes and interdependencies of ozone and its major precursors. Results are shown for four mid- to high-latitude sites where different Pandora instruments were used. Comparisons with a well calibrated double-grating Brewer spectrometer over a period of more than a year in Greenbelt MD showed excellent agreement and a small bias of approximately 2 DU (or, 0.6%). This was constant with slant column ozone amount over the full range of observed solar zenith angles (15-80), indicating adequate Pandora stray light correction. A small (1-2%) seasonal difference was found, consistent with sensitivity studies showing that the Pandora spectral fitting TCO retrieval has a temperature dependence of 1% per 3K, with an underestimation in temperature (e.g., during summer) resulting in an underestimation of TCO. Pandora agreed well with Aura-OMI (Ozone Measuring Instrument) satellite data, with average residuals of <1% at the different sites when the OMI view was within 50 km from the Pandora location and OMI-measured cloud fraction was <0.2. The frequent and continuous measurements by Pandora revealed significant short-term (hourly) temporal changes in TCO, not possible to capture by sun-synchronous satellites, such as OMI, alone.

Ozone↗