At least 55 records · Page 3

TPSAS-NF1676L-10746-DND

This paper presents the design, development, and field testing of a high sensitivity ground-based Differential Absorption Lidar (DIAL) system that was developed under the NASA Instrument Incubator Program. The investigation presents a significant advancement towards the development of future CO2 profiling capability as it incorporates key elements of technologies needed for a future development of global CO2 measuring systems including: (1) 2-μm laser technologies that have been developed under a number of NASA programs including the Laser Risk Reduction Program (LRRP) (2) A novel high quantum efficiency (QE), high gain (without excess noise factor), and low noise phototransistor, and (3) Direct detection DIAL system using a large collection area receiver that is insensitive to speckle and coherence length effects from atmospheric turbulence that influences heterodyne detection systems. The objective of the project was a system TRL of 4, and the goal was TRL 5. Development and testing of the laser, new detector, and receiver systems during the project, integration into a complete lidar system into a trailer, field testing of system at West Branch, IA and comparison of the lidar CO2 measurements with in situ sensors advanced the system to a TRL of 5. The system demonstrated high vertical resolution CO2 profiling capability within the boundary layer and column measurements to long ranges. This is the first direct detection demonstration of a 2-micron CO2 DIAL high vertical resolution capability from instrument concept to field demonstration.

Syed Ismail↗

Southern Hemisphere Additional Ozonesondes (SHADOZ) Ozone Climatology (2005-2009): Tropospheric and Tropical Tropopause Layer (TTL) Profiles with Comparisons to Omi-based Ozone Products

We present a regional and seasonal climatology of SHADOZ ozone profiles in the troposphere and tropical tropopause layer (TTL) based on measurements taken during the first five years of Aura, 2005-2009, when new stations joined the network at Hanoi, Vietnam; Hilo, Hawaii; Alajuela Heredia, Costa Rica; Cotonou, Benin. In all, 15 stations operated during that period. A west-to-east progression of decreasing convective influence and increasing pollution leads to distinct tropospheric ozone profiles in three regions: (1) western Pacific eastern Indian Ocean; (2) equatorial Americas (San Cristobal, Alajuela, Paramaribo); (3) Atlantic and Africa. Comparisons in total ozone column from soundings, the Ozone Monitoring Instrument (OMI, on Aura, 2004-) satellite and ground-based instrumentation are presented. Most stations show better agreement with OMI than they did for EPTOMS comparisons (1998-2004; Earth-ProbeTotal Ozone Mapping Spectrometer), partly due to a revised above-burst ozone climatology. Possible station biases in the stratospheric segment of the ozone measurement noted in the first 7 years of SHADOZ ozone profiles are re-examined. High stratospheric bias observed during the TOMS period appears to persist at one station. Comparisons of SHADOZ tropospheric ozone and the daily Trajectory-enhanced Tropospheric Ozone Residual (TTOR) product (based on OMIMLS) show that the satellite-derived column amount averages 25 low. Correlations between TTOR and the SHADOZ sondes are quite good (typical r2 0.5-0.8), however, which may account for why some published residual-based OMI products capture tropospheric interannual variability fairly realistically. On the other hand, no clear explanations emerge for why TTOR-sonde discrepancies vary over a wide range at most SHADOZ sites.

gravity waves↗

Profiles of Reactive Trace Gases over Remote Oceans During ATom

The Atmospheric Tomography (ATom) mission deployed an extensive gas and aerosol payload on the NASA DC-8 aircraft on four campaigns spanning each season. ATom systematically sampled the atmosphere from 0.2 to 12 kilometer altitude, from 85 degrees North Latitude to 65 degrees South Latitude, in both the Pacific and the Atlantic to provide detailed profiles of chemical composition over the remote oceans. We will present profiles of reactive trace species, such as O3, NOx, NOy, HOx, HCHO, and several other short-lived source gases. We will combine these measurements with results from a 0-D box model to show their utility in (1) evaluating gradients in latitude/season, (2) identifying contributions of pollution from long-range and convective transport, and (3) evaluating column measurements from remote sensing satellite instruments.

ISAF↗

TPSAS-NF1676L-11930-DND

Under the NASA Laser Risk Reduction Program (LRRP), funded by Earth Science Technology Office (ESTO), an efficient, injection seeded, high repetition rate Tm:fiber laser pumped Ho:YLF laser has been developed and operation between 100 Hz to 10 kHz has been demonstrated. The work is underway to develop an efficient, high-repetition-rate, pulsed, 2-micron, coherent Differential Absorption Lidar (DIAL) / Integrated Path Differential Absorption (IPDA) instrument for measuring the atmospheric CO2 profiles (DIAL) and column densities (IPDA) from an airborne platform. In DIAL mode, this instrument will provide the first ever range-resolved, high-precision, remote measurements of the CO2 content of the atmospheric boundary layer (ABL) and lower troposphere.

Upendra N Singh↗

Global Distribution and 14-Year Changes in Erythemal Irradiance, UV Atmospheric Transmission, and Total Column Ozone 2005 – 2018 Estimated from OMI and EPIC Observations

Satellite data from the Ozone Measuring Instrument (OMI) and Earth Polychromatic Imaging Camera (EPIC) are used to study changes and global distribution of UV erythemal irradiance in mW/m(exp 2) E(ζ,φ,z,t) and the dimensionless UV index (E/25 mWm(exp 2)) over the Earth’s surface as a function of latitude ζ, longitude φ, altitude z, and time t. OMI time series data starting in January 2005 to December 2018 are used to estimate 14-year changes in erythemal irradiance, total column ozone TCO3, scene reflectivity LER, and aerosol absorption τA at specific land sites in the Northern and Southern Hemispheres using publicly available OMI data. Estimates of changes in atmospheric transmission ΔCτ(ζ,φ,z,t) derived from OMI measured cloud and haze reflectivity show an increase between 60°S to 45°S almost no average 14-year change from 55°S to 30°N but show an increase from 35°N to 55°N. This implies increased solar insolation at higher latitudes that suggests positive feedback for global warming. Changes in aerosol absorption of UV irradiance ΔCA(ζ,φ,z,t) derived from changes in τA are mostly in the equatorial region and at higher southern latitudes resulting in correlated changes in E. TCO3 derived from OMI data has increased at a rate of 2% per decade for the latitudes between 60°S to 10°N changing to a decrease of 1% per decade between 40°N to 60°N. The result is an average decrease in E(ζ,φ,z,t) at a rate of 2% per decade in the Southern Hemisphere and an increase between 40°N to 60°N. For some specific sites (latitudes from 55°S to 45°N) there has been little or no change in E(ζ,φ,z,t) for the period 2005 – 2018. Nearly half the sites show strong correlation effects of both short- and long-term cloud and absorbing aerosol change as well as anticorrelation with total column ozone change ΔTCO3. Synoptic EPIC data from the sunlit Earth are used to derive ozone and reflectivity needed for global images of the distribution of E(ζ,φ,z,t) from sunrise to sunset centered on the Americas, Europe-Africa, and Asia. EPIC data are used to show the latitudinal distribution of E(ζ,φ,z,t) from the equator to 75° for specific longitudes. Dangerously high amounts of erythemal irradiance (12 < UV index < 18) are found for many low latitude and high-altitude sites (e.g., San Pedro, Chile (2.45 km), La Paz, Bolivia (3.78 km). Lower UV indices at some equatorial or high-altitude sites (e.g., Quito, Ecuador) are moderated by the presence of persistent cloud effects. High UVI levels (UVI > 6) are also found at most mid-latitude sites during the summer months.

Ozone Measuring Instrument (OMI) and Earth Polychr↗

Characterization of Errors in Satellite-Based HCHO/NO 2 Tropospheric Column Ratios With Respect to Chemistry, Column-to-PBL Translation, Spatial Representation, and Retrieval Uncertainties

The availability of formaldehyde (HCHO) (a proxy for volatile organic compound reactivity) and nitrogen dioxide (NO 2 ) (a proxy for nitrogen oxides) tropospheric columns from ultraviolet–visible (UV–Vis) satellites has motivated many to use their ratios to gain some insights into the near-surface ozone sensitivity. Strong emphasis has been placed on the challenges that come with transforming what is being observed in the tropospheric column to what is actually in the planetary boundary layer (PBL) and near the surface; however, little attention has been paid to other sources of error such as chemistry, spatial representation, and retrieval uncertainties. Here we leverage a wide spectrum of tools and data to quantify those errors carefully. Concerning the chemistry error, a well-characterized box model constrained by more than 500 h of aircraft data from NASA's air quality campaigns is used to simulate the ratio of the chemical loss of HO 2 + RO 2 (LRO x ) to the chemical loss of NO x (LNO x ). Subsequently, we challenge the predictive power of HCHO/NO 2 ratios (FNRs), which are commonly applied in current research, in detecting the underlying ozone regimes by comparing them to LRO x /LNO x . FNRs show a strongly linear (R 2 =0.94) relationship with LRO x /LNO x , but only on the logarithmic scale. Following the baseline (i.e., ln(LRO x /LNO x ) = −1.0 ± 0.2) with the model and mechanism (CB06, r2) used for segregating NO x -sensitive from VOC-sensitive regimes, we observe a broad range of FNR thresholds ranging from 1 to 4. The transitioning ratios strictly follow a Gaussian distribution with a mean and standard deviation of 1.8 and 0.4, respectively. This implies that the FNR has an inherent 20 % standard error (1σ) resulting from not accurately describing the RO x –HO x cycle. We calculate high ozone production rates (PO 3 ) dominated by large HCHO × NO 2 concentration levels, a new proxy for the abundance of ozone precursors. The relationship between PO 3 and HCHO × NO 2 becomes more pronounced when moving towards NO x -sensitive regions due to nonlinear chemistry; our results indicate that there is fruitful information in the HCHO × NO 2 metric that has not been utilized in ozone studies. The vast amount of vertical information on HCHO and NO 2 concentrations from the air quality campaigns enables us to parameterize the vertical shapes of FNRs using a second-order rational function permitting an analytical solution for an altitude adjustment factor to partition the tropospheric columns into the PBL region. We propose a mathematical solution to the spatial representation error based on modeling isotropic semivariograms. Based on summertime-averaged data, the Ozone Monitoring Instrument (OMI) loses 12 % of its spatial information at its native resolution with respect to a high-resolution sensor like the TROPOspheric Monitoring Instrument (TROPOMI) (> 5.5 × 3.5 km 2 ). A pixel with a grid size of 216 km 2 fails at capturing ∼ 65 % of the spatial information in FNRs at a 50 km length scale comparable to the size of a large urban center (e.g., Los Angeles). We ultimately leverage a large suite of in situ and ground-based remote sensing measurements to draw the error distributions of daily TROPOMI and OMI tropospheric NO 2 and HCHO columns. At a 68 % confidence interval (1σ), errors pertaining to daily TROPOMI observations, either HCHO or tropospheric NO 2 columns, should be above 1.2–1.5 × 10 16 molec. cm −2 to attain a 20 %–30 % standard error in the ratio. This level of error is almost non-achievable with the OMI given its large error in HCHO. The satellite column retrieval error is the largest contributor to the total error (40 %–90 %) in the FNRs. Due to a stronger signal in cities, the total relative error (< 50 %) tends to be mild, whereas areas with low vegetation and anthropogenic sources (e.g., the Rocky Mountains) are markedly uncertain (> 100 %). Our study suggests that continuing development in the retrieval algorithm and sensor design and calibration is essential to be able to advance the application of FNRs beyond a qualitative metric.

Amir H. Souri↗

Version 2 of the global catalogue of large anthropogenic and volcanic SO 2 sources and emissions derived from satellite measurements

Sulfur dioxide (SO 2 ) measurements from the Ozone Monitoring Instrument (OMI), Ozone Mapping and Profiler Suite (OMPS), and TROPOspheric Monitoring Instrument (TROPOMI) satellite spectrometers were used to update and extend the previously developed global catalogue of large SO 2 emission sources. This version 2 of the global catalogue covers the period of 2005–2021 and includes a total of 759 continuously emitting point sources releasing from about 10 kt yr −1 to more than 4000 kt yr −1 of SO 2 , that have been identified and grouped by country and primary source origin: volcanoes (106 sources); power plants (477); smelters (74); and sources related to the oil and gas industry (102). There are several major improvements compared to the original catalogue: it combines emissions estimates from three satellite instruments instead of just OMI, uses a new version 2 of the OMI and OMPS SO 2 dataset, and updated consistent site-specific air mass factors (AMFs) are used to calculate SO 2 vertical column densities (VCDs). The newest TROPOMI SO 2 data processed with the Covariance-Based Retrieval Algorithm (COBRA), used in the catalogue, can detect sources with emissions as low as 8 kt yr −1 (in 2018–2021) compared to the 30 kt yr −1 limit for OMI. In general, there is an overall agreement within ±12 % in total emissions estimated from the three satellite instruments for large regions. For individual emission sources, the spread is larger: the annual emissions estimated from OMI and TROPOMI agree within ±13 % in 50 % of cases and within ±28 % in 90 % of cases. The version 2 catalogue emissions were calculated as a weighted average of emission estimates from the three satellite instruments using an inverse-variance weighting method. OMI, OMPS, and TROPOMI data contribute 7 %, 5 %, and 88 % to the average, respectively, for small (<30 kt yr −1 ) sources and 33 %, 20 %, and 47 %, respectively, for large (>300 kt yr −1 ) sources. The catalogue data show an approximate 50 % decline in global SO 2 emissions between 2005 and 2021, although emissions were relatively stable during the last 3 years. The version 2 of the global catalogue has been posted at the NASA global SO 2 monitoring website (https://doi.org/10.5067/MEASURES/SO2/DATA406, Fioletov et al., 2022).

volcanic↗

High Precision, Absolute Total Column Ozone Measurements from the Pandora Spectrometer System: Comparisons with Data from a Brewer Double Monochromator and Aura OMI

We present new, high precision, high temporal resolution measurements of total column ozone (TCO) amounts derived from ground-based direct-sun irradiance measurements using our recently deployed Pandora single-grating spectrometers. Pandora's small size and portability allow deployment at multiple sites within an urban air-shed and development of a ground-based monitoring network for studying small-scale atmospheric dynamics, spatial heterogeneities in trace gas distribution, local pollution conditions, photochemical processes and interdependencies of ozone and its major precursors. Results are shown for four mid- to high-latitude sites where different Pandora instruments were used. Comparisons with a well calibrated double-grating Brewer spectrometer over a period of more than a year in Greenbelt MD showed excellent agreement and a small bias of approximately 2 DU (or, 0.6%). This was constant with slant column ozone amount over the full range of observed solar zenith angles (15-80), indicating adequate Pandora stray light correction. A small (1-2%) seasonal difference was found, consistent with sensitivity studies showing that the Pandora spectral fitting TCO retrieval has a temperature dependence of 1% per 3K, with an underestimation in temperature (e.g., during summer) resulting in an underestimation of TCO. Pandora agreed well with Aura-OMI (Ozone Measuring Instrument) satellite data, with average residuals of <1% at the different sites when the OMI view was within 50 km from the Pandora location and OMI-measured cloud fraction was <0.2. The frequent and continuous measurements by Pandora revealed significant short-term (hourly) temporal changes in TCO, not possible to capture by sun-synchronous satellites, such as OMI, alone.

Ozone↗

Wavelength Locking to CO2 Absorption Line-Center for 2-Micron Pulsed IPDA Lidar Application

An airborne 2-micron triple-pulse integrated path differential absorption (IPDA) lidar is currently under development at NASA Langley Research Center (LaRC). This IPDA lidar system targets both atmospheric carbon dioxide (CO2) and water vapor (H2O) column measurements. Independent wavelength control of each of the transmitted laser pulses is a key feature for the success of this instrument. The wavelength control unit provides switching, tuning and locking for each pulse in reference to a 2-micron CW (Continuous Wave) laser source locked to CO2 line-center. Targeting the CO2 R30 line center, at 2050.967 nanometers, a wavelength locking unit has been integrated using semiconductor laser diode. The CO2 center-line locking unit includes a laser diode current driver, temperature controller, center-line locking controller and CO2 absorption cell. This paper presents the CO2 center-line locking unit architecture, characterization procedure and results. Assessment of wavelength jitter on the IPDA measurement error will also be addressed by comparison to the system design.

Refaat, Tamer F.↗

Accuracy and Precision in the Southern Hemisphere Additional Ozonesondes (SHADOZ) Dataset 1998-2000 in Light of the JOSIE-2000 Results

A network of 12 southern hemisphere tropical and subtropical stations in the Southern Hemisphere ADditional OZonesondes (SHADOZ) project has provided over 2000 profiles of stratospheric and tropospheric ozone since 1998. Balloon-borne electrochemical concentration cell (ECC) ozonesondes are used with standard radiosondes for pressure, temperature and relative humidity measurements. The archived data are available at:http: //croc.gsfc.nasa.gov/shadoz. In Thompson et al., accuracies and imprecisions in the SHADOZ 1998- 2000 dataset were examined using ground-based instruments and the TOMS total ozone measurement (version 7) as references. Small variations in ozonesonde technique introduced possible biases from station-to-station. SHADOZ total ozone column amounts are now compared to version 8 TOMS; discrepancies between the two datasets are reduced 2\% on average. An evaluation of ozone variations among the stations is made using the results of a series of chamber simulations of ozone launches (JOSIE-2000, Juelich Ozonesonde Intercomparison Experiment) in which a standard reference ozone instrument was employed with the various sonde techniques used in SHADOZ. A number of variations in SHADOZ ozone data are explained when differences in solution strength, data processing and instrument type (manufacturer) are taken into account.

Witte, J. C.↗

Carbon Dioxide Active Remote Sensing Using Pulsed 2-µm Lidar

A pulsed 2-µm Integrate Path Differential Absorption (IPDA) lidar was developed at NASA Langley Research Center for high-accuracy and high-precision measurements of atmospheric carbon dioxide (CO 2 ). The instrument targets the R30 CO 2 absorption line and implements high-energy tunable on-line transmitter and advanced HgCdTe avalanche photodiode receiver. During 2019 airborne validation campaign, the IPDA was tested over the ocean for retrieving the weighted-average column dry-air volume mixing ratio of CO 2 (XCO 2 ) from 4.5 km altitude. XCO 2 measurement resulted in 404.43 ± 1.23 ppm using 10 s average, as compared to 405.49 ppm from prediction models. This translates to 0.26% and 0.30% relative accuracy and precision, respectively. Performance models were updated to scale the IPDA technology assuming operation from space platform. Results present XCO 2 measurements using the instrument capabilities considering different target scenarios for Earth’s surface. This demonstrates the potential for the IPDA technique and technology to achieve sustained global CO 2 measurement.

Active Remote Sensing↗

Carbon Dioxide Active Remote Sensing Using Pulsed 2-µm Lidar

A pulsed 2-µm Integrate Path Differential Absorption (IPDA) lidar was developed at NASA Langley Research Center for high-accuracy and high-precision measurements of atmospheric carbon dioxide (CO 2 ). The instrument targets the R30 CO 2 absorption line and implements high-energy tunable on-line transmitter and advanced HgCdTe avalanche photodiode receiver. During 2019 airborne validation campaign, the IPDA was tested over the ocean for retrieving the weighted-average column dry-air volume mixing ratio of CO 2 (XCO 2 ) from 4.5 km altitude. XCO 2 measurement resulted in 404.43 ± 1.23 ppm using 10 s average, as compared to 405.49 ppm from prediction models. This translates to 0.26% and 0.30% relative accuracy and precision, respectively. Performance models were updated to scale the IPDA technology assuming operation from space platform. Results present XCO 2 measurements using the instrument capabilities considering different target scenarios for Earth’s surface. This demonstrates the potential for the IPDA technique and technology to achieve sustained global CO 2 measurement.

Active Remote Sensing↗

Relationship Between Column-Density and Surface Mixing Ratio: Statistical Analysis of O3 and NO2 Data from the July 2011 Maryland DISCOVER-AQ Mission

To investigate the ability of column (or partial column) information to represent surface air quality, results of linear regression analyses between surface mixing ratio data and column abundances for O3 and NO2 are presented for the July 2011 Maryland deployment of the DISCOVER-AQ mission. Data collected by the P-3B aircraft, ground-based Pandora spectrometers, Aura/OMI satellite instrument, and simulations for July 2011 from the CMAQ air quality model during this deployment provide a large and varied data set, allowing this problem to be approached from multiple perspectives. O3 columns typically exhibited a statistically significant and high degree of correlation with surface data (R(sup 2) > 0.64) in the P- 3B data set, a moderate degree of correlation (0.16 < R(sup 2) < 0.64) in the CMAQ data set, and a low degree of correlation (R(sup 2) < 0.16) in the Pandora and OMI data sets. NO2 columns typically exhibited a low to moderate degree of correlation with surface data in each data set. The results of linear regression analyses for O3 exhibited smaller errors relative to the observations than NO2 regressions. These results suggest that O3 partial column observations from future satellite instruments with sufficient sensitivity to the lower troposphere can be meaningful for surface air quality analysis.

nitrogen dioxide↗

Trend Quality Ozone from NPP OMPS: The Version 2 Processing

A version 2 processing of data from two ozone monitoring instruments on Suomi NPP, the OMPS nadir ozone mapper and the OMPS nadir ozone profiler, has now been completed. The previously released data were useful for many purposes but were not suitable for use in ozone trend analysis. In this processing, instrument artifacts have been identified and corrected, an improved scattered light correction and wavelength registration have been applied, and soft calibration techniques were implemented to produce a calibration consistent with data from the series of SBUV/2 instruments. The result is a high-quality ozone time series suitable for trend analysis. Total column ozone data from the OMPS nadir mapper now agree with data from the SBUV/2 instrument on NOAA 19 with a zonal average bias of −0.2 % over the 60° S to 60° N latitude zone. Differences are somewhat larger between OMPS nadir profiler and N19 total column ozone, with an average difference of −1.1 % over the 60° S to 60° N latitude zone and a residual seasonal variation of about 2 % at latitudes higher than about 50°. For the profile retrieval, zonal average ozone in the upper stratosphere (between 2.5 and 4 hPa) agrees with that from NOAA 19 within ±3 % and an average bias of −1.1 %. In the lower stratosphere (between 25 and 40 hPa) agreement is within ±3 % with an average bias of +1.1 %. Tropospheric ozone produced by subtracting stratospheric ozone measured by the OMPS limb profiler from total column ozone measured by the nadir mapper is consistent with tropospheric ozone produced by subtracting stratospheric ozone from MLS from total ozone from the OMI instrument on Aura. The agreement of tropospheric ozone is within 10 % in most locations.

OMPS nadir ozone mapper↗

Application of OMI Observations to a Space-Based Indicator of NOx and VOC Controls on Surface Ozone Formation

We investigated variations in the relative sensitivity of surface ozone formation in summer to precursor species concentrations of volatile organic compounds (VOCs) and nitrogen oxides (NOx) as inferred from the ratio of the tropospheric columns of formaldehyde to nitrogen dioxide (the "Ratio") from the Aura Ozone Monitoring Instrument (OMI). Our modeling study suggests that ozone formation decreases with reductions in VOCs at Ratios less than 1 and NOx at Ratios greater than 2; both NOx and VOC reductions may decrease ozone formation for Ratios between 1 and 2. Using this criteria. the OMI data indicate that ozone formation became: 1. more sensitive to NOx over most of the United States from 2005 to 2007 because of the substantial decrease in NOx emissions, primarily from stationary sources, and the concomitant decrease in the tropospheric column of NO2. and 2. more sensitive to NOx with increasing temperature, in part because emissions of highly reactive, biogenic isoprene increase with temperature, thus increasing the total VOC reactivity. In cities with relatively low isoprene emissions (e.g .. Chicago). the data clearly indicate that ozone formation became more sensitive to NOx from 2005 to 2007. In cities with relatively high isoprene emissions (e.g ., Atlanta), we found that the increase in the Ratio due to decreasing NOx emissions was not obvious as this signal was convolved with variations in the Ratio associated with the temperature dependence of isoprene emissions and, consequently, the formaldehyde concentration.

Duncan, Bryan N.↗

Observations of Solar Spectral Irradiance Change During Cycle 22 from NOAA-9 SBUV/2

The NOM-9 Solar Backscatter Ultraviolet, model 2 (SBUV/2) instrument is one of a series of instruments providing daily solar spectral irradiance measurements in the middle and near ultraviolet since 1978. The SBUV/2 instruments are primarily designed to measure stratospheric profile and total column ozone, using the directional albedo as the input to the ozone processing algorithm. As a result, the SBUV/2 instrument does not have onboard monitoring of all time-dependent response changes. We have applied internal comparisons and vicarious (external) comparisons to determine the long-term instrument characterization for NOAA-9 SBUV/2 to derive accurate solar spectral irradiances from March 1985 to May 1997 spanning two solar cycle minima with a single instrument. The NOAA-9 data show an amplitude of 9.3(+/- 2.3)% (81-day averaged) at 200-205 nm for solar cycle 22. This is consistent with the result of (Delta)F(sub 200-205) = 8.3(+/- 2.6)% for cycle 21 from Nimbus-7 SBUV and (Delta)F(sub 200-205) = 10(+/- 2)% (daily values) for cycle 23 from UARS SUSIM. NOAA-9 data at 245-250 nm show a solar cycle amplitude of (Delta)F(sub 245-250) = 5.7(+/- 1.8)%. NOAA-9 SBUV/2 data can be combined with other instruments to create a 25-year record of solar UV irradiance.

DeLand, Matthew T.↗