Search NASA⌕ Search

SEARCH · Search NASA

Results for “2D Inspection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Automated eddy current inspection of Space Shuttle APU turbine wheel blades

An automated inspection system based on eddy current testing (ET) techniques has been developed to inspect turbine wheel blades on the APU used in NASA's Space Transportation system. The APU is a hydrazine-powered gas turbine with a 15-cm diameter Rene 41 turbine wheel, which has 123 first-stage blades and 123 second-stage blades. The flaw detection capability of the ET system is verified through comparison with fluorescent penetrant test results. Results of the comparison indicate that ET is capable of inspecting surfaces with very restrictive geometries. The ET capability requires development of probes with extremely small coils to allow inspection within 0.4 mm of the blade root and the leading and trailing edges of the blade and within a height restriction of less than 1 mm. The color 2D presentation of the ET data provided crack-growth pattern and length information similar to those found with visual techniques. It also provided visual clues to minimize geometry effects such as generated from blade edges, a neighoring blade, and changes in the blade thickness.

Fisher, Jay L.↗

Tip-Induced 3D Printing on the Nanoscale with Field Emission Scanning Probes

3D printing down to the nanoscale remains a significant challenge. In this paper, the study explores the use of scanning probes that emit low-energy electrons (<100 eV) coupled with the localized injection and electron-induced decomposition of precursor molecules, for the precise localized deposition of 3D nanostructures. The experiments are performed inside the chamber of a scanning electron microscope (SEM), enabling the use of the in-built gas injector system (GIS) with gaseous naphthalene precursor for carbon deposition, as well as immediate inspection of the deposits by SEM. Substrate materials are planar fused silica with thin conductive coatings and non-planar copper wedges. After investigation of the deposition process parameters, various 2D and 3D carbon deposits are grown. Vertical nanowires several microns in length with a diameter <100 nm are achieved and 3D deposits with a high degree of nanoscale branching are also obtained, presumably due to a charging effect. High aspect ratio carbon nanostructures such as those demonstrated here can be employed as miniaturized electrodes or field emitters. The tip-based approach presented thus paves the way toward 3D nanoscale printing of various materials and functional nanostructures.

3D printing↗

Software Method for Computed Tomography Cylinder Data Unwrapping, Re-slicing, and Analysis

A software method has been developed that is applicable for analyzing cylindrical and partially cylindrical objects inspected using computed tomography (CT). This method involves unwrapping and re-slicing data so that the CT data from the cylindrical object can be viewed as a series of 2D sheets (or flattened onion skins ) in addition to a series of top view slices and 3D volume rendering. The advantages of viewing the data in this fashion are as follows: (1) the use of standard and specialized image processing and analysis methods is facilitated having 2D array data versus a volume rendering; (2) accurate lateral dimensional analysis of flaws is possible in the unwrapped sheets versus volume rendering; (3) flaws in the part jump out at the inspector with the proper contrast expansion settings in the unwrapped sheets; and (4) it is much easier for the inspector to locate flaws in the unwrapped sheets versus top view slices for very thin cylinders. The method is fully automated and requires no input from the user except proper voxel dimension from the CT experiment and wall thickness of the part. The software is available in 32-bit and 64-bit versions, and can be used with binary data (8- and 16-bit) and BMP type CT image sets. The software has memory (RAM) and hard-drive based modes. The advantage of the (64-bit) RAM-based mode is speed (and is very practical for users of 64-bit Windows operating systems and computers having 16 GB or more RAM). The advantage of the hard-drive based analysis is one can work with essentially unlimited-sized data sets. Separate windows are spawned for the unwrapped/re-sliced data view and any image processing interactive capability. Individual unwrapped images and un -wrapped image series can be saved in common image formats. More information is available at http://www.grc.nasa.gov/WWW/OptInstr/ NDE_CT_CylinderUnwrapper.html.

Roth, Don J.↗

Dual X-ray computed tomography-aided classification of melt pool boundaries and flaws in crept additively manufactured parts

In metal additive manufacturing (AM), understanding the process-structure-performance relationships requires a combination of multi-scale characterization techniques that allows for the measurement of the melt pool shape and boundary and classifying various defects and flaws in the AM parts. Such approaches can be destructive, only 2D in nature, or have a small field of view and can be complex to co-register and analyze. Here, in this work, we present a non-destructive 3D inspection technique that employs dual-energy X-ray computed tomography (XCT) along with a model-based iterative reconstruction (MBIR) and a new segmentation algorithm. The proposed approach and algorithm are not only capable of classifying and quantifying flaws such as pores, cracks, and inclusions, but they also allow for the extraction of microstructural features such as melt pool boundaries (MPB) and melt pool regions (MPR), that can help understand process-structure-performance relationships for alloys under study. As an exemplar application, we employed the method for characterization of an additively manufactured aluminum alloy crept under tensile stress at 300 °C for 1064 h. Our results demonstrate high quality segmentation and classification of various flaws and MPB and MPR, for the first time, using 3D X-ray CT inspection. The delineated MPB and MPR in the crept samples reveal the preferential growth paths of cracks that formed during creep deformation. The technique was used for successfully quantifying the characteristics (number of defects, their density, volume fraction, etc.) of the manufacturing-induced pores and creep-induced cracks, which is necessary to better understand the creep failure mechanisms of the material.

36 MATERIALS SCIENCE↗

Electric Potential and Electric Field Imaging with Dynamic Applications: 2017 Research Award Innovation

The technology and methods for remote quantitative imaging of electrostatic potentials and electrostatic fields in and around objects and in free space is presented. Electric field imaging (EFI) technology may be applied to characterize intrinsic or existing electric potentials and electric fields, or an externally generated electrostatic field may be used for illuminating volumes to be inspected with EFI. The baseline sensor technology (e-Sensor) and its construction, optional electric field generation (quasi-static generator), and current e- Sensor enhancements (ephemeral e-Sensor) are discussed. Critical design elements of current linear and real-time two-dimensional (2D) measurement systems are highlighted, and the development of a three dimensional (3D) EFI system is presented. Demonstrations for structural, electronic, human, and memory applications are shown. Recent work demonstrates that phonons may be used to create and annihilate electric dipoles within structures. Phonon induced dipoles are ephemeral and their polarization, strength, and location may be quantitatively characterized by EFI providing a new subsurface Phonon-EFI imaging technology. Initial results from real-time imaging of combustion and ion flow, and their measurement complications, will be discussed. These new EFI capabilities are demonstrated to characterize electric charge distribution creating a new field of study embracing areas of interest including electrostatic discharge (ESD) mitigation, crime scene forensics, design and materials selection for advanced sensors, combustion science, on-orbit space potential, container inspection, remote characterization of electronic circuits and level of activation, dielectric morphology of structures, tether integrity, organic molecular memory, atmospheric science, and medical diagnostic and treatment efficacy applications such as cardiac polarization wave propagation and electromyography imaging.

Generazio, Ed↗

Resin transfer molding of textile composites

The design and manufacture of textile composite panels, tubes, and angle sections that were provided to NASA for testing and evaluation are documented. The textile preform designs and requirements were established by NASA in collaboration with Boeing and several vendors of textile reinforcements. The following four types of preform architectures were used: stitched uniweave, 2D-braids, 3D-braids, and interlock weaves. The preforms consisted primarily of Hercules AS4 carbon fiber; Shell RSL-1895 resin was introduced using a resin transfer molding process. All the finished parts were inspected using ultrasonics.

Falcone, Anthony↗

NASA Tech Briefs, August 2005

Topics include: Hidden Identification on Parts: Magnetic Machine-Readable Matrix Symbols; System for Processing Coded OFDM Under Doppler and Fading; Multipurpose Hyperspectral Imaging System; Magnetic-Flux-Compensated Voltage Divider; High-Performance Satellite/Terrestrial-Network Gateway; Internet-Based System for Voice Communication With the ISS; Stripline/Microstrip Transition in Multilayer Circuit Board; Dual-Band Feed for a Microwave Reflector Antenna; Quadratic Programming for Allocating Control Effort; Range Process Simulation Tool; Simulator of Space Communication Networks; Computing Q-D Relationships for Storage of Rocket Fuels; Contour Error Map Algorithm; Portfolio Analysis Tool; Glass Frit Filters for Collecting Metal Oxide Nanoparticles; Anhydrous Proton-Conducting Membranes for Fuel Cells; Portable Electron-Beam Free-Form Fabrication System; Miniature Laboratory for Detecting Sparse Biomolecules; Multicompartment Liquid-Cooling/Warming Protective Garments; Laser Metrology for an Optical-Path-Length Modulator; PCM Passive Cooling System Containing Active Subsystems; Automated Electrostatics Environmental Chamber; Estimating Aeroheating of a 3D Body Using a 2D Flow Solver; Artificial Immune System for Recognizing Patterns; Computing the Thermodynamic State of a Cryogenic Fluid; Safety and Mission Assurance Performance Metric; Magnetic Control of Concentration Gradient in Microgravity; Avionics for a Small Robotic Inspection Spacecraft; and Simulation of Dynamics of a Flexible Miniature Airplane.

Source record↗

Electric Potential and Electric Field Imaging with Dynamic Applications & Extensions

The technology and methods for remote quantitative imaging of electrostatic potentials and electrostatic fields in and around objects and in free space is presented. Electric field imaging (EFI) technology may be applied to characterize intrinsic or existing electric potentials and electric fields, or an externally generated electrostatic field made be used for volumes to be inspected with EFI. The baseline sensor technology (e-Sensor) and its construction, optional electric field generation (quasi-static generator), and current e- Sensor enhancements (ephemeral e-Sensor) are discussed. Critical design elements of current linear and real-time two-dimensional (2D) measurement systems are highlighted, and the development of a three dimensional (3D) EFI system is presented. Demonstrations for structural, electronic, human, and memory applications are shown. Recent work demonstrates that phonons may be used to create and annihilate electric dipoles within structures. Phonon induced dipoles are ephemeral and their polarization, strength, and location may be quantitatively characterized by EFI providing a new subsurface Phonon-EFI imaging technology. Results from real-time imaging of combustion and ion flow, and their measurement complications, will be discussed. Extensions to environment, Space and subterranean applications will be presented, and initial results for quantitative characterizing material properties are shown. A wearable EFI system has been developed by using fundamental EFI concepts. These new EFI capabilities are demonstrated to characterize electric charge distribution creating a new field of study embracing areas of interest including electrostatic discharge (ESD) mitigation, manufacturing quality control, crime scene forensics, design and materials selection for advanced sensors, combustion science, on-orbit space potential, container inspection, remote characterization of electronic circuits and level of activation, dielectric morphology of structures, tether integrity, organic molecular memory, atmospheric science, weather prediction, earth quake prediction, and medical diagnostic and treatment efficacy applications such as cardiac polarization wave propagation and electromyography imaging.

Generazio, Ed↗

SU-F-BRE-13: Replacing Pre-Treatment Phantom QA with 3D In-Vivo Portal Dosimetry for IMRT Breast Cancer

Purpose: Pre-treatment QA of individual treatment plans requires costly linac time and physics effort. Starting with IMRT breast treatments, we aim to replace pre-treatment QA with in-vivo portal dosimetry. Methods: Our IMRT breast cancer plans are routinely measured using the ArcCheck device (SunNuclear). 2D-Gamma analysis is performed with 3%/3mm criteria and the percentage of points with gamma<1 (nG1) is calculated within the 50% isodose surface. Following AAPM recommendations, plans with nG1<90% are approved; others need further inspection and might be rejected. For this study, we used invivo portal dosimetry (IPD) to measure the 3D back-projected dose of the first three fractions for IMRT breast plans. Patient setup was online corrected before for all measured fractions. To reduce patient related uncertainties, the three IPD results were averaged and 3D-gamma analysis was applied with abovementioned criteria . For a subset of patients, phantom portal dosimetry (PPD) was also performed on a slab phantom. Results: Forty consecutive breast patients with plans that fitted the EPID were analysed. The average difference between planned and IPD dose in the reference point was −0.7+/−1.6% (1SD). Variation in nG1 between the 3 invivo fractions was about 6% (1SD). The average nG1 for IPD was 89+/−6%, worse than ArcCheck (95+/−3%). This can be explained by patient related factors such as changes in anatomy and/or model deficiencies due to e.g. inhomogeneities. For the 20 cases with PPD, mean nG1 was equal to ArcCheck values, which indicates that the two systems are equally accurate. These data therefore suggest that proper criteria for 3D invivo verification of breast treatments should be nG1>80% instead of nG1>90%, which, for our breast cases, would result in 5% (2/40) further inspections. Conclusion: First-fraction in-vivo portal dosimetry using new gamma-evaluation criteria will replace phantom measurements in our institution, saving resources and yielding 3D dosimetry of the actual patient treatment.

60 APPLIED LIFE SCIENCES↗

Enhanced Raman scattering from aromatic dithiols electrosprayed into plasmonic nanojunctions

We describe surface enhanced Raman spectroscopy (SERS) experiments in which molecular coverage is systematically varied from 3.8 x 105 to 3.8 x 102 to 0.38 molecules/μm2 using electrospray deposition of ethanolic 4,4’-dimercaptostilbene (DMS) solutions. The plasmonic SERS substrate used herein consists of a well-characterized 2-dimensional (2D) array of silver nanospheres [see El-Khoury et al., J. Chem. Phys., 2014, 141, 214308], previously shown to feature uniform topography and plasmonic response, as well as intense SERS activity. When compared to their ensemble averaged analogues, the spatially and temporally averaged spectra of a single molecule exhibit several unique features including: (i) distinct relative intensities of the observable Raman-active vibrational states, (ii) more pronounced SERS backgrounds, and (iii) broader Raman lines indicative of faster vibrational dephasing. The first observation may be understood on the basis of an intuitive physical picture in which removal of averaging over multiple molecules exposes the tensorial nature of Raman scattering. When an oriented single molecule gives rise to the recorded SERS spectra, the relative orientation of the molecule with respect to vector components of the local electric field determines the relative intensities of the observable vibrational states. Using a single molecule SERS framework described herein, we derive a unique molecular orientation in which a single DMS molecule is isolated at a nanojunction formed between two silver nanospheres in the 2D array. The DMS molecule is found lying nearly flat with respect to the metal surface. The derived orientation of a single molecule at a plasmonic nanojunction is consistent with observations (ii) and (iii). In particular, a careful inspection of the temporal spectral variations along the recorded single molecule SERS time sequences reveals that the time-averaged SERS backgrounds arise from individual molecular events, marked by broadened SERS signatures. We assign the broadened spectra along the SERS time sequence – which sum up to a SERS background in the averaged spectra – to instances in which the π-framework of the DMS molecule is parallel to the metal surface. This also accounts for Raman line broadening as a result of fast vibrational dephasing and driven by molecular reorientation at a plasmonic nanojunction. Furthermore, we report on the orientation dependence of single molecule SERS enhancement factors. We find that in the case of a single DMS molecule isolated at a plasmonic nanojunction, molecular orientation may affect the derived single molecule SERS enhancement factor by up to 5 orders of magnitude. Taking both chemical effects as well as molecular orientation into account, we were able to estimate a single molecule enhancement factor of ~1010 in our measurements.

Environmental Molecular Sciences Laboratory↗

TU-F-CAMPUS-T-02: Vernier Picket Fence Test: A Non-Imaging Method to Localize the Radiation Isocenter with Submillimeter Accuracy

Purpose: The purpose of this study is to propose a new non-imaging method to localize the radiation isocenter with submillimeter accuracy. Methods: The Vernier picket fence (VPF) is a multileaf collimator (MLC) picket fence sequence in which the fence spacing is 1/N smaller than the detector spacing of the QA phantom, where N is the magnification factor, typically set to 10 or 20. Similar to reading a Vernier caliper, the user can easily achieve the resolution of 1/N of the detector spacing by visually inspecting the maximum signal. To achieve higher accuracy, a Gaussian model was used to interpolate the peak position, which can fall between adjacent detectors. In two separate tests, precise MLC offsets and imprecise couch offsets were applied to a 2D detector array (MapCheck, Sun Nuclear Corp., Melbourne, Florida) to introduce setup errors. Two vertical VPF fields were delivered with collimator angles at 0° and 90° to detect the lateral and longitudinal setup errors, respectively. For a rotational QA phantom, an additional lateral VPF field is needed to detect the vertical setup error for three-dimensional capabilities. Results: With N set to 20 and a detector spacing of 5 mm for MapCheck, the resolution of the VPF’s visual analysis is 0.25 mm. With the Gaussian interpretation, the VPF can achieve an accuracy of 0.02 mm, as shown by the MLC offset test. The couch offset test measured the couch hysteresis and demonstrated that the setup error detected by the VPF differed from the ExacTrac™ (Brainlab AG, Feldkirchen, Germany) optical tracking by 0.055 mm in the lateral direction and 0.041 mm in the longitudinal direction on average. The VPF was also shown to be feasible in the vertical direction as well. Conclusion: This study verified the VPF as a non-imaging method to localize the radiation isocenter with submillimeter accuracy. Funding is in part by the Portland Chapter of the Achievement Rewards for College Scientists. The content is solely the responsibility of the authors, and does not necessarily represent the official views of the sponsors. The authors declare no conflict of interest.

60 APPLIED LIFE SCIENCES↗

NanoFIBrication of a two-dimensional phononic crystal in a free standing membrane.

A two-dimensional phononic crystal (PnC) that can operate in the GHz range is created in a freestanding silicon substrate using NanoFIBrication (using a focused ion beam (FIB) to fabricate nanostructures). First, a simple cubic 6.75 x 6.75 ?m array of vias with 150 nm spacing is generated. After patterning the vias, they are backfilled with void-free tungsten scatterers. Each via has a diameter of 48 nm. Numerical calculations predict this 2D PnC will generate a band gap near 22 GHz. A protective layer of chromium on top of the thin (100 nm) silicon membrane confines the surface damage to the chromium, which can be removed at a later time. Inspection of the underside of the membrane shows the vias flaring out at the exit, which we are dubbing the 'trumpet effect'. The trumpet effect is explained by modeling the lateral damage in a freestanding membrane.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Requirements for Soldering Fluxes Research using the B-53 Test Board

IPC J-STD-004B standard prescribes general requirements for the classification and testing of soldering flux for high qualify interconnections. This standard defines the classification of soldering materials through specifications of test methods and inspection criteria. The materials include liquid flux, paste flux, solderpaste flux, solder preform flux, and flux-cored solder. This research will use the proposed IPC-53 Surface Insulation Resistance (SIR) test patterns by means of an open comb (2D) and closed comb (3D to simulate a component over the comb pattern). The 2D open comb has uniformity of conductor spacing, sheet resistance, and flux outgassing. The 3D-closed comb simulates the effect of leadless or bottom-terminated components, which have non-uniform sheet resistance and flux outgassing. The response variables will include SIR testing and visual imaging. The objective is to investigate IPC test method improvements for characterizing soldering fluxes when using leadless components with narrow pad-to-pad spacing.

Diamond, Louis↗

Recent modelling advances for ultrasonic TOFD inspections

The ultrasonic TOFD (Time of Flight Diffraction) Technique is commonly used to detect and characterize disoriented cracks using their edge diffraction echoes. An overview of the models integrated in the CIVA software platform and devoted to TOFD simulation is presented. CIVA allows to predict diffraction echoes from complex 3D flaws using a PTD (Physical Theory of Diffraction) based model. Other dedicated developments have been added to simulate lateral waves in 3D on planar entry surfaces and in 2D on irregular surfaces by a ray approach. Calibration echoes from Side Drilled Holes (SDHs), specimen echoes and shadowing effects from flaws can also been modelled. Some examples of theoretical validation of the models are presented. In addition, experimental validations have been performed both on planar blocks containing calibration holes and various notches and also on a specimen with an irregular entry surface and allow to draw conclusions on the validity of all the developed models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of similarity measures for use in the intensity-based rigid 2D-3D registration for patient positioning in radiotherapy

Purpose: Rigid 2D-3D registration is an alternative to 3D-3D registration for cases where largely bony anatomy can be used for patient positioning in external beam radiation therapy. In this article, the authors evaluated seven similarity measures for use in the intensity-based rigid 2D-3D registration using a variation in Skerl's similarity measure evaluation protocol. Methods: The seven similarity measures are partitioned intensity uniformity, normalized mutual information (NMI), normalized cross correlation (NCC), entropy of the difference image, pattern intensity (PI), gradient correlation (GC), and gradient difference (GD). In contrast to traditional evaluation methods that rely on visual inspection or registration outcomes, the similarity measure evaluation protocol probes the transform parameter space and computes a number of similarity measure properties, which is objective and optimization method independent. The variation in protocol offers an improved property in the quantification of the capture range. The authors used this protocol to investigate the effects of the downsampling ratio, the region of interest, and the method of the digitally reconstructed radiograph (DRR) calculation [i.e., the incremental ray-tracing method implemented on a central processing unit (CPU) or the 3D texture rendering method implemented on a graphics processing unit (GPU)] on the performance of the similarity measures. The studies were carried out using both the kilovoltage (kV) and the megavoltage (MV) images of an anthropomorphic cranial phantom and the MV images of a head-and-neck cancer patient. Results: Both the phantom and the patient studies showed the 2D-3D registration using the GPU-based DRR calculation yielded better robustness, while providing similar accuracy compared to the CPU-based calculation. The phantom study using kV imaging suggested that NCC has the best accuracy and robustness, but its slow function value change near the global maximum requires a stricter termination condition for an optimization method. The phantom study using MV imaging indicated that PI, GD, and GC have the best accuracy, while NCC and NMI have the best robustness. The clinical study using MV imaging showed that NCC and NMI have the best robustness. Conclusions: The authors evaluated the performance of seven similarity measures for use in 2D-3D image registration using the variation in Skerl's similarity measure evaluation protocol. The generalized methodology can be used to select the best similarity measures, determine the optimal or near optimal choice of parameter, and choose the appropriate registration strategy for the end user in his specific registration applications in medical imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploring 3D elastic-wave scattering at interfaces using high-resolution phased-array system

The elastic-wave scattering at interfaces, such as cracks, is essential for nondestructive inspections, and hence, understanding the phenomenon is crucial. However, the elastic-wave scattering at cracks is very complex in three dimensions since microscopic asperities of crack faces can be multiple scattering sources. We propose a method for exploring 3D elastic-wave scattering based on our previously developed high-resolution 3D phased-array system, the piezoelectric and laser ultrasonic system (PLUS). We describe the principle of PLUS, which combines a piezoelectric transmitter and a 2D mechanical scan of a laser Doppler vibrometer, enabling us to resolve a crack into a collection of scattring sources. Subsequently, we show how the 3D elastic-wave scattering in the vicinity of each response can be extracted. Here, we experimentally applied PLUS to a fatigue-crack specimen. We found that diverse 3D elastic-wave scattering occurred in a manner depending on the responses within the fatigue crack. This is significant because access to such information will be useful for optimizing inspection conditions, designing ultrasonic measurement systems, and characterizing cracks. More importantly, the described methodology is very general and can be applied to not only metals but also other materials such as composites, concrete, and rocks, leading to progress in many fields.

36 MATERIALS SCIENCE↗

3D Localization of Defects in Facility Inspection

Wind tunnels are crucial facilities that support the aerospace industry. However, these facilities are large, complex, and pose unique maintenance and inspection requirements. Manual inspections to identify defects such as cracks, missing fasteners, leaks, and foreign objects are important but labor and schedule intensive. Our goal is to utilize small Unmanned Aircraft Systems (sUAS) and computer vision-based analysis to automate the inspection of the interior and exterior of NASA’s critical wind tunnel facilities. We detect missing fasteners as our defect class, and detect existing fasteners to provide potential future missing fastener sites for preventative maintenance. These detections are done on both 2D raw images and in 3D space to provide a visual reference and real world location to facilitate repairs. A dataset was created consisting of images taken along a grid-like pattern of an interior tunnel section in the AEDC National Full-Scale Aerodynamics Complex (NFAC) at NASA Ames Research Center. Our method uses object detection to create image level bounding boxes of the fasteners and missing fasteners, then uses photogrammetry to create a mapping from 2D image locations to 3D real world locations. The image level bounding boxes and the 2D to 3D mapping are then combined to determine the 3D location of the defects. We describe the data collection, photogrammetry, and computer vision techniques used for object detection as well as a quantitative analysis of the method.

Small Unmanned Aircraft Systems (sUAS)↗

3D X-ray CT for BGA/CGA Workmanship Defect Detection

Commercial-off-the-shelf (COTS) advanced microelectronic technologies in high-reliability versions are now being considered for use in a number of National Aeronautics and Space Administration (NASA) electronic systems. One of the key drawbacks of advanced electronic packages with hidden solder joint interconnections, such as the column grid array (CGA), is that inspection can be challenging—whether visually or using X-rays. In general, inspection for solder joint integrity is poor, except for identifying shorts. The new, advanced X-ray systems, especially the 3D computer tomography version, may be able to provide the three-dimensional features that are extremely difficult to resolve under the 2D systems.This report presents both 2D and 3D X-ray images along with their representative optical photomicrographs for a number of advanced electronics package assemblies including 3D stack and CGA assemblies before and after thermal cycling.

Ghaffarian, Reza↗