Search NASA⌕ Search

SEARCH · Search NASA

Results for “2G”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Performance of 2G-HTS REBCO undulator coils impregnated epoxies mixed with different fillers

The use of second-generation high-temperature superconducting-coated conductors enables an enhancement of the performance of undulator magnets. However, preventing the motion of the wire and providing sufficient conduction cooling to the winding stacks have remained challenges. In this study, we have evaluated epoxy impregnation techniques to address these issues. Epoxy resin was prepared with different nanopowders and the effect on the performance of the undulator coil pack was investigated. All epoxy impregnated coils showed smaller n values and some degree of deterioration of the critical current I c . The I c degradation was most pronounced for epoxy mixed with high aspect ratio multiwalled carbon nanotubes (MWCNTs). It has been found that the crack formation in the epoxy results in plastic deformation of the copper stabilizer layer, which causes the underlying ceramic REBCO superconducting layer to crack resulting in degradation of the superconducting tape performance. As a result, careful adjustment of epoxy thickness surrounding the superconductor and the powder ratio in the epoxy eliminate the performance degradation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Superconducting Joint for 2G HTS Tapes

An approach of the epitaxial jointing of the GdBa{sub 2}Cu{sub 3}O{sub 7 – δ}-based tapes using the YBa{sub 2}Cu{sub 3}O{sub 7 – δ} layer is proposed. The structural and electrical characteristics of the formed joint have been investigated. Using the scanning transmission electron microscopy, the cross section of the joined region has been studied, partial melting of the YBa{sub 2}Cu{sub 3}O{sub 7 – δ} layer has been observed, and the solid-phase diffusion with the formation of the (Gd, Y)Ba{sub 2}Cu{sub 3}O{sub 7 – δ}, Y{sub 2}BaCuO{sub 5}, BaCuO{sub 2}, and CuO phases has been established. It is shown that the current-carrying capability of the superconducting joint is over 30% of the initial tape current.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effects of N[superscript 2],N[superscript 2]-dimethylguanosine on RNA structure and stability: Crystal structure of an RNA duplex with tandem m[superscript 2 subscript 2]G:A pairs

Methylation of the exocyclic amino group of guanine is a relatively common modification in rRNA and tRNA. Single methylation (N(2)-methylguanosine, m(2)G) is the second most frequently encountered nucleoside analog in Escherichia coli rRNAs. The most prominent case of dual methylation (N(2),N(2)-dimethylguanosine, m(2) (2)G) is found in the majority of eukaryotic tRNAs at base pair m(2) (2)G26:A44. The latter modification eliminates the ability of the N(2) function to donate in hydrogen bonds and alters its pairing behavior, notably vis-a-vis C. Perhaps a less obvious consequence of the N(2),N(2)-dimethyl modification is its role in controlling the pairing modes between G and A. We have determined the crystal structure of a 13-mer RNA duplex with central tandem m(2) (2)G:A pairs. In the structure both pairs adopt an imino-hydrogen bonded, pseudo-Watson-Crick conformation. Thus, the sheared conformation frequently seen in tandem G:A pairs is avoided due to a potential steric clash between an N(2)-methyl group and the major groove edge of A. Additionally, for a series of G:A containing self-complementary RNAs we investigated how methylation affects competitive hairpin versus duplex formation based on UV melting profile analysis.

08 HYDROGEN↗

Acute exposure to 2G phase shifts the rat circadian timing system

The circadian timing system (CTS) provides internal and external temporal coordination of an animal's physiology and behavior. In mammals, the generation and coordination of these circadian rhythms is controlled by a neural pacemaker, the suprachiasmatic nucleus (SCN), located within the hypothalamus. The pacemaker is synchronized to the 24 hour day by time cures (zeitgebers) such as the light/dark cycle. When an animal is exposed to an environment without time cues, the circadian rhythms maintain internal temporal coordination, but exhibit a 'free-running' condition in which the period length is determined by the internal pacemaker. Maintenance of internal and external temporal coordination are critical for normal physiological and psychological function in human and non-human primates. Exposure to altered gravitational environments has been shown to affect the amplitude, mean, and timing of circadian rhythms in species ranging from unicellular organisms to man. However, it has not been determined whether altered gravitational fields have a direct effect on the neural pacemaker, or affect peripheral parameters. In previous studies, the ability of a stimulus to phase shift circadian rhythms was used to determine whether a stimulus has a direct effect on the neural pacemaker. The present experiment was performed in order to determine whether acute exposure to a hyperdynamic field could phase shift circadian rhythms.

Hoban-Higgins, T. M.↗

2nd Generation Reusable Launch Vehicle (2G RLV)

This is a revised final report and addresses all of the work performed on this program. Specifically, it covers vehicle architecture background, definition of six baseline engine cycles, reliability baseline (space shuttle main engine QRAS), and component level reliability/performance/cost for the six baseline cycles, and selection of 3 cycles for further study. This report further addresses technology improvement selection and component level reliability/performance/cost for the three cycles selected for further study, as well as risk reduction plans, and recommendation for future studies.

Matlock, Steve↗

Alterations of Body Mass Gain of Neonates (P7&P14) During Certrifugation AT 2G

Previous research has shown animal body mass to be significantly affected by centrifugation. At the onset of centrifugation, animals have a selective loss of fat, causing an initial body mass loss. Body mass gain will resume at the same rate as uncentrifuged animals, but this subsequent gain will be lower. For this study, two different ages of Sprague Hawley neonate families were observed during centrifugation. Eight litters (dam with eight neonates) of postnatal day (PN) seven and four litters (dam with ten neonates) of PN 14 were separated into two separate groups each, centrifuge (+2G(sub z)) and environmental controls (EC) and placed into either the centrifuge or an animal holding unit in the centrifuge rotunda for a total of 16 days. P7: Total litter start mass of +2G(sub z) litter = 138.90 g/end = 311.0 g EC litter = 150.85 g/end = 516.9 g. P14: Total litter start mass of +2G(sub z) litter = 287.70 g/end = 762.5g; EC litter = 245 g/end = 942.9 g. An initial body mass loss was observed in both groups of +2G(sub z) animals for two days after the onset of centrifugation, but then an increase began to occur. Literature suggests adult animals at +2G(sub z), will have an initial loss, but will resume similar growth rates over time as compared to control animals. The P7 +2G(sub z) animals began to gain body mass, but showed a significantly slower growth rate than their EC animals for the duration of the test (pace). The P14 +2G(sub z) animals began to show similar growth rates to their EC after day nine. At day 16, both groups of +2Gz animals were significantly smaller than the EC animals (pace). At +2Gz, animals experience an initial body mass loss. Older animals are able to resume similar growth rates as their controls, but younger animals showed growth rates to be significantly reduced.

Baer, L. A.↗

Changes in hypothalamic staining for c-Fos following 2G exposure in rats

The static gravitational field of the earth has been an important selective pressure that has shaped the evolution of biological organisms. This is illustrated by the evolution of tetrapods from a water environment where gravitational force was partially negated to a terrestrial environment where gravity is of greater consequence. Terrestrial invasion resulted in a series of new structural, physiological, and behavioral features. Therefore, it is not surprising that alterations in the gravitational field can cause widespread effects in many physiological systems and behaviors. Our previous studies have demonstrated that both exposure to hyperdynamic fields and the microgravity condition of space flight have significant effects on body temperature, heartrate, activity, feeding, drinking, and circadian rhythms. However, it has not been determined whether these physiological adaptations are associated with changes in neural activity within the hypothalamic nuclei that regulate these functions. This study examined the changes in body temperature, activity, body weight and food and water intake in rats caused by exposure to a hyperdynamic field. In addition, the immediate early gene activation marker, c-Fos, was used to examine potential protein synthesis changes in the hypothalamic nuclei that regulate these functions.

NASA Discipline Regulatory Physiology↗

Spectroscopic and dielectric response of zinc bismuth phosphate glasses as a function of chromium content

Graphical abstract: 20ZnF{sub 2}–(20 − x)Bi{sub 2}O{sub 3}–60P{sub 2}O{sub 5}:xCr{sub 2}O{sub 3} (0 ≤ x ≤2 mol%) glasses are prepared by melt quenching technique. The optical absorption spectra of present glasses are analyzed as a function of chromium content. The absorption bands are assigned to {sup 4}A{sub 2g}(F) ⟶ {sup 4}T{sub 1g}(F), {sup 4}A{sub 2g}(F) ⟶ {sup 4}T{sub 2g}(F), {sup 4}A{sub 2g}(F) ⟶ {sup 2}T{sub 1g}(G) and {sup 4}A{sub 2g}(F) ⟶ {sup 2}E{sub g}(G) transitions of Cr{sup 3+} ions. - Highlights: • ZnF{sub 2}–Bi{sub 2}O{sub 3}–P{sub 2}O{sub 5}:Cr{sub 2}O{sub 3} glasses were prepared by melt quenching and annealing. • Spectroscopic and dielectric properties of chromium ions were investigated. • ESR and optical absorption spectra indicate the co-existence of Cr{sup 6+} ions with Cr{sup 5+} ions and Cr{sup 3+} ions. • Cr{sup 3+} ions act as modifiers and influence the semiconducting nature of the glass system. - Abstract: 20ZnF{sub 2}–(20 − x)Bi{sub 2}O{sub 3}–60P{sub 2}O{sub 5}:xCr{sub 2}O{sub 3} (0 ≤ x ≤2 mol%) glasses are prepared by melt quenching technique. Amorphous nature of these samples is confirmed by X-ray diffraction (XRD) analysis. FTIR study reveals bands due to CrO{sub 6}(o{sub d}) and CrO{sub 4}{sup 2−}(T{sub d}) units along with conventional phosphate groups. The optical absorption and ESR studies of present glasses are analyzed as a function of chromium content. The absorption bands are assigned to {sup 4}A{sub 2g}(F) ⟶ {sup 4}T{sub 1g}(F), {sup 4}A{sub 2g}(F) ⟶ {sup 4}T{sub 2g}(F), {sup 4}A{sub 2g}(F) ⟶ {sup 2}T{sub 1g}(G) and {sup 4}A{sub 2g}(F) ⟶ {sup 2}E{sub g}(G) transitions of Cr{sup 3+} ions. The highest concentration of Cr{sup 3+} ions (in octahedral sites, with network modifying positions) is found in the sample with 2.0 mol% of Cr{sub 2}O{sub 3}. The analysis of dielectric properties indicates a gradual increase in semiconducting character with increase in the concentration of Cr{sub 2}O{sub 3} from 0.2 to 2.0 mol%. The studies on dielectric breakdown strength identify the highest insulating strength for lowest mol% of Cr{sub 2}O{sub 3} in the present samples.

36 MATERIALS SCIENCE↗

The Effects of Hypergravity and Adrenalectomy on Bone Mineral Content, Urine Calcium and Body Mass in Rats

The effects of 14 days of increased gravitational load, and the absence of adrenal stress hormones on total body bone mineral content (BMC) were examined in male Sprague-Dawley rats. Centrifugation at 2 Gs (2G) was used to increase the gravitational load, and bilateral adrenalectomy (ADX) was used to eliminate the production of adrenal stress hormones. Stationary groups at 1 G (1G) and sham operated (SHAM) animals served as controls. Thirty rats (n=6 or 8) made up the four experimental groups (1G SHAM, 1G ADX, 2G SHAM and 2G ADX). BMC was assessed by dual energy x-ray absorptiometry (DXA) which was performed to determine the total body bone mineral content, and also through bone ashing of the left femur and the left humerus. Activity was determined through biotelemetry, also body mass and food intake were measured. Multi-factorial analysis of variance (MANCOVA) and Newman Keuls post hoc tests were used to analyze significant effects (p is less than 0.05) for the primary variables. Results from both DXA and the ashed femur indicated that BMC decreased significantly with increased G for both the SHAM and ADX groups. The BMC determined by DXA for the 1G ADX group was also significantly lower than the 1G SHAM group, however the 2G SHAM and 2G ADX groups were not significantly different. However, the bone ashing results showed the femur differed significantly only between the rates of centrifugation and not between the ADX and SHAM. The humerus showed no significant difference between any of the groups. There was a significant decrease in body mass with increased G and there was no ADX effect on body mass. When DXA BMC was normalized for body mass changes, there were no significant group differences. However, with bone ashing, the femur BMC/BW still showed significant difference between rates of centrifugation, with the 2G group being lower. Activity level decreased with body mass, and food intake data showed there was significant hypophagia during the first few days of centrifugation. Urine calcium was measured and was found decrease at the start of centrifugation for the 2G groups and rise to a level higher than that of the stationary groups. Finally, the correlation between BW and BMC was determined to be highly correlated (r = .71). These results suggest that the decrease in total body BMC seen with hypergravity may be based to a large extent on the differences in body mass induced by the 2G load.

Lau, A.↗

Raman spectroscopy of titanomagnetites: Calibration of the intensity of Raman peaks as a sensitive indicator for their Ti content

A systematic study of the Raman spectra of the titanomagnetite solid-solution series (Fe{sub 3-x}Ti{sub x}O{sub 4}) for x = {approx}0.0, 0.2, 0.4, and 0.6 has been conducted. The samples showed combinations of five previously predicted Raman peaks at {approx}190, 310, 460, 540, and 670 cm{sup -1} that correspond to vibrational modes with T{sub 2g}(1), E{sub g}, T{sub 2g}(3), T{sub 2g}(2), and A{sub 1g}, respectively. The calibration of Raman spectra for titanomagnetite with known values of Ti concentrations reveals a strong dependence of relative intensity for the T{sub 2g}(2) and T{sub 2g}(3) modes on Ti concentration. The most prominent feature is the appearance and increase in the relative intensity of a T{sub 2g}(3) peak above x = {approx}0.2. On the other hand, the Raman peak for the T{sub 2g}(2) mode gradually diminishes as Ti increases and nearly disappears at x = {approx}0.6. Combining the two relative intensities potentially provides a sensitive indicator of Ti content. The technique was applied to study titanomagnetite in grains from Hana Volcanics and melatroctolite from Rhode Island.

Zinin, Pavel↗

Design, Test and Demonstration of Saturable Reactor High-Temperature Superconductor Fault Current Limiters

Zenergy Power has successfully designed, built, tested, and installed in the US electrical grid a saturable reactor Fault Current Limiter. Beginning in 2007, first as SC Power Systems and from 2008 as Zenergy Power, Inc., ZP used DOE matching grant and ARRA funds to help refine the design of the saturated reactor fault current limiter. ZP ultimately perfected the design of the saturated reactor FCL to the point that ZP could reliably design a suitable FCL for most utility applications. Beginning with a very basic FCL design using 1G HTS for a coil housed in a LN2 cryostat for the DC bias magnet, the technology progressed to a commercial system that was offered for sale internationally. Substantial progress was made in two areas. First, the cryogenics cooling system progressed from a sub-cooled liquid nitrogen container housing the HTS coils to cryostats utilizing dry conduction cooling and reaching temperatures down to less than 20 degrees K. Large, round cryostats with warm bore diameters of 1.7 meters enabled the design of large tanks to hold the AC components. Second, the design of the AC part of the FCL was refined from a six legged spider design to a more compact and lighter design with better fault current limiting capability. Further refinement of the flux path and core shape led to an efficient saturated reactor design requiring less Ampere-turns to saturate the core. In conclusion, the development of the saturable reactor FCL led to a more efficient design not requiring HTS magnets and their associated peripheral equipment, which yielded a more economical product in line with the electric utility industry expectations. The original goal for the DOE funding of the ZP project Design, Test and Demonstration of Saturable Reactor High-Temperature Superconductor Fault Current Limiters was to stimulate the HTS wire industry with, first 1G, then 2G, HTS wire applications. Over the approximately 5 years of ZP's product development program, the amount of HTS wire employed per FCL and its cost as a percentage of the total FCL product content had not dropped substantially from an unsustainable level of more than 50% of the total cost of the FCL, nor had the availability increased (today the availability of 2G wire for commercial applications outside of specific partnerships with the leading 2G wire manufacturers is extremely limited). ZP had projected a very significant commercial potential for FCLs with higher performance and lower costs compared to the initial models built with 1G wire, which would come about from the widespread availability of low-cost, high-performance 2G HTS wire. The potential for 2G wires at greatly reduced performance-based prices compared to 1G HTS conductor held out the potential for the commercial production of FCLs at price and performance levels attractive to the utility industry. However, the price of HTS wire did not drop as expected and today the available quantities of 2G wire are limited, and the price is higher than the currently available supplies of 1G wire. The commercial option for ZP to provide a reliable and reasonably priced FCL to the utility industry is to employ conventional resistive conductor DC electromagnets to bias the FCL. Since the premise of the original funding was to stimulate the HTS wire industry and ZP concluded that copper-based magnets were more economical for the foreseeable future, DOE and ZP decided to mutually terminate the project.

24 POWER TRANSMISSION AND DISTRIBUTION↗