At least 55 records · Page 3

Developing VSC-HVDC Oscillation Damping Control Constraints in Unit Commitment

High-voltage direct current (HVDC) systems within the existing power grids will play a pivotal role in enabling high share of renewable power integration and transportation electrification. There is a need for transmission planning models to accurately capture the impact of VSC-HVDC oscillation damping control on the system planning and model the constraints in the security constrained unit commitment (SCUC) problem. In this paper, the SCUC problem in a hybrid DC-AC grid considering damping on electromechanical inter-area oscillation is studied. An electromechanical oscillation-driven transmission capability constraints are derived from system swing equation and incorporated into the SCUC. Multiple system damping control scenarios are set based on the extracted plausible bounds of damping coefficient and inertia constant to linearize the nonlinear expressions. The SCUC problem with proposed constraints is tested on the Reliability Test System Grid Modernization Lab Consortium (RTS-GMLC) via PLEXOS. The impact of the proposed constraints on regional generation, inertia, power flow, annual system cost, and renewable energy curtailment are fully assessed.

damping control↗

Developing VSC-HVDC Oscillation Damping Control Constraints in Unit Commitment

High-voltage direct current (HVDC) systems within the existing power grids will play a pivotal role in enabling high share of renewable power integration and transportation electrification. There is a need for transmission planning models to accurately capture the impact of VSC-HVDC oscillation damping control on the system planning and model the constraints in the security constrained unit commitment (SCUC) problem. In this paper, the SCUC problem in a hybrid DC-AC grid considering damping on electromechanical inter-area oscillation is studied. An electromechanical oscillation-driven transmission capability constraints are derived from system swing equation and incorporated into the SCUC. Multiple system damping control scenarios are set based on the extracted plausible bounds of damping coefficient and inertia constant to linearize the nonlinear expressions. The SCUC problem with proposed constraints is tested on the IEEE 73-bus reliability test system (RTS) case via PLEXOS. The impact of the proposed constraints on regional generation, inertia, power flow, annual system cost, and renewable energy curtailment are fully assessed.

damping control↗

BEEAM (Building Electrical Efficiency Analysis Model) [SWR-20-107]

Modern high-performance buildings exhibit an increasing number of building loads that use direct current (DC) electricity internally, rather than alternating current (AC), due to the advent of low-cost computing and advanced power electronics. Powering DC devices from the AC grid requires AC/DC power conversion, which introduces energy losses and reduces efficiency. As DC loads proliferate, the cumulative wasted energy associated with hundreds of millions of AC/DC converters has become one of the broadest energy savings opportunities in buildings. DC power distribution systems have been proposed as an elegant and transformative solution to the problem of DC devices. In a DC distribution system, the building's wires carry DC electricity, rather than AC; and a few centralized, highly efficient AC/DC converters replace the many smaller, less efficient converters that serve individual DC loads. Unfortunately, the trade-offs associated with DC distribution systems are not well understood. Reported energy savings associated with DC power distribution differ widely and have not been well validated. The Building Electrical Efficiency Analysis Model (BEEAM) is a Modelica library that simulates the efficiency of building electrical distribution systems using harmonic power flow. BEEAM can model a wide variety of building distribution topologies, including three-phase AC, single-phase AC, unipolar DC, bipolar DC, and hybrid networks under both balanced and unbalanced load conditions. BEEAM accurately models power electronic converter losses, provides granular estimates of losses throughout the distribution system, and properly models efficiency at part load conditions. Users can package BEEAM within a functional mockup unit (FMU), enabling co-simulation with other modeling platform, such as EnergyPlus. In summary, BEEAM provides a tool suite for fair and accurate comparison of the efficiency of building electrical distribution systems, including AC, DC, and hybrid systems.

Frank, Stephen↗

A Neural Network-Based Power Mismatch Elimination Strategy for Integrated Solar and ESS AC/DC Systems (MARS)

The multiport autonomous reconfigurable solar power plant (MARS) is a promising concept for the integration of photovoltaic (PV) and energy storage system (ESS) to the transmission ac grid and a high-voltage direct current (HVdc) link. The presence of PV and ESS in each arm of the MARS results in uneven distribution of active power among different submodules (SMs), thereby leading to unbalanced SM capacitor voltages and potentially compromising the system stability. Moreover, in the case of partial shadings, shaded PV SMs will suffer from decreased power injections causing power mismatch in the MARS system. To address this issue, a neural-network-based power mismatch elimination (NNPME) strategy is proposed in this article. The proposed NNPME strategy optimizes ESS usage and leverages both dc and ac circulating currents to facilitate power transfer among the SMs, arms, and phases of the MARS system. Simulation and control hardware-in-the-loop (cHIL) experiments demonstrate the effectiveness of the proposed NNPME strategy. Compared with the traditional approaches, the proposed NNPME strategy can significantly enhance system efficiency and ensure stable and continuous operation, even in the presence of uneven power distribution within the MARS system.

14 SOLAR ENERGY↗

Fidelity Analysis of Complex Large-Scale Simulation Models of PEs (MARS) in Future Power Grids

With the proliferation of power electronic (PE)-based resources in the electric grid, there have been numerous different kinds of simulation models developed and studied to understand their dynamic behavior. Study of PE-based resources using each simulation model has its own distinct advantages and disadvantages. Therefore it is very important to carefully select the appropriate model for the evaluation of the PE-based resources. In this paper, one such effort is made to analyze the different types of models in the case of a multi-port autonomous reconfigurable solar power plant (MARS). The MARS integrates a hybrid photovoltaic (PV)-energy storage system (ESS) plant to high-voltage direct current (HVdc) system and transmission alternating current (ac) grid. The dynamic models are evaluated under different test cases varying the short-circuit ratio (SCR) and control algorithms. Recommendations are provided on the equipment study needs based on the analysis completed.

Marthi, Phani Ratna Vanamali↗

Hybrid Data-Driven Based HVdc Ancillary Control for Multiple Frequency Data Attacks

The high voltage direct current (HVdc) intertie has been applied to provide ancillary-services for ac grids, utilizing the real-time feedback from phasor measurement units (PMUs). However, PMU data communication is vulnerable to false data injection attacks (FDIA) due to protocol defects, thus the HVdc ancillary control and system stability will be threatened. To address this issue, this article proposes a novel HVdc control strategy based on a hybrid data-driven (HDD) methodology. In this work, the HDD methodology is first proposed to detect the types and duration time of multiple frequency attacks. Specifically, the Hilbert Huang transform (HHT) is used to decompose the frequency data, using variational mode decomposition instead of the traditional empirical mode decomposition, to extract data features. Second, a multikernel support vector machine is proposed to classify the attacked data based on the designed distinctive features from HHT. Meanwhile, the attacking duration time is decided using an unsupervised technique. Third, an HDD-based HVdc ancillary control strategy is established to eliminate the effect of FDIAs on the HVdc frequency response. Comprehensive experiments of HDD-based HVdc ancillary controls under different FDIAs suggest that the proposed HDD could fast and accurately classify the FDIAs, and the HDD-based HVdc ancillary control strategy could significantly suppress the impact of the FDIAs.

97 MATHEMATICS AND COMPUTING↗

7.2 kV Three-Port SiC Single-Stage Current-Source Solid-State Transformer With 90 kV Lightning Protection

This article proposes a multiport modular single-stage current-source solid-state transformer (SST) for applications like photovoltaic, energy storage integration, electric vehicle fast charging, data center, etc. The 7.2 kV 50 kVA current-source SST consists of five input-series output-parallel modules, each based on 3.3 kV SiC reverse-blocking MOSFET-plus-diode modules. The proposed SST has some unique features. First, compared to the voltage-source or matrix converter-based SSTs, the current-source SST has a unique advantage of single-stage isolated AC/DC or AC/AC conversion with an inductive DC link, but no medium-voltage (MV) AC experiments have been reported. This article for the first time demonstrates MV AC current-source SST up to 7.5 kV peak. Second, the multiport SST has a buffer port for active power decoupling (APD) or energy storage integration. The double-line-frequency power ripple from single-phase AC grid normally results in a large capacitor size in MV SSTs. The APD scheme is proposed in MV applications for the first time to enable a reduced DC link and the electrolytic capacitor-less SST with high reliability. Third, as a direct grid-connected converter without line-frequency transformer, insulation and protection are critical. A medium-frequency transformer design passes 55 kV basic-insulation level (BIL) and 60 kV high potential dielectrics withstand test with only 0.09% leakage inductance. Importantly, a lightning protection scheme is presented to protect the SST itself from 90 kV BIL impulse. Fourth, the proposed current-source SST topology is a modular soft-switching solid-state transformer (M-S4T) with full-range zero-voltage switching and controlled dv/dt for low electromagnetic interference. Furthermore, these concepts are verified in a three-port M-S4T prototype with forced oil cooling under single-module, stacked-module, steady-state, and dynamic operations.

14 SOLAR ENERGY↗

Control System of Multi-Port Autonomous Reconfigurable Solar Power Plant (MARS) & HIL Platforms for Design

Multi-port autonomous reconfigurable solar power plant (MARS) provides an attractive alternative to connect photovoltaic (PV) and energy storage systems (ESSs) to high-voltage direct current (HVdc) links and high-voltage alternating current (ac) grids. In this paper, a unique hierarchical control system of MARS is proposed and evaluated. To evaluate the control system and associated algorithms in early-stage research of complex architectures like MARS, it is important to develop unique suitable hardware-in-the-loop (HIL) platforms. In this paper, the HIL platforms for MARS to evaluate the performance of the hierarchical control system and the control algorithms implemented are presented. Further, they help with the design process of control systems. The real-time simulation models and algorithms that are utilized for MARS in the HIL platforms are also discussed in the paper. The HIL experiments of the control system of MARS showcase the capability to provide continuity of operation under faults and frequency support to the power grid during loss of generation. They also showcase the stability of the proposed hierarchical control system of MARS.

14 SOLAR ENERGY↗

Advanced Vehicle Testing Activity Benchmark Testing of the Chevrolet Volt Onboard Charger

The Chevrolet Volt onboard charge module, which converts alternating current (AC) power into direct current (DC) power to charge the vehicle’s onboard energy storage system, was benchmark tested for AC to DC efficiency by the Idaho National Laboratory as part of its conduct of the U.S. Department of Energy’s Advanced Vehicle Testing Activity. Charging with Level 2 electric vehicle supply equipment (EVSE) at 208 VAC input (60 Hz), the Volt onboard charge module was calculated to be 91.7% efficient while operating between 3.0 AC kW and 3.3 AC kW. Charging with Level 1 EVSE at 120 VAC input (60 Hz) the Volt onboard charge module was calculated to be 90.6% efficient while operating near 1.3 AC kW. Given that most Level 2 EVSE are greater than 99% efficient1 when operating above 3.0 AC kW (Level 2) and a Level 1 EVSE was measured to be 98% efficient2 when operating above 1.25 AC kW (120VAC), the average overall AC to DC charging efficiency for the Chevrolet Volt connected to an EVSE (from the AC grid through the EVSE and the Volt’s onboard charge module OBCM) is 90.8% for Level 2 and 88.8% for Level 1.

25 ENERGY STORAGE↗

Control system development for an organic Rankine cycle engine

The development of a control logic to govern the toluene throttle valve and verify the stability of the speed control approach for multiple engines connected to a 1 MWe point focus solar generator installation for distributed applications is presented. The toluene is is pumped by booster and main feed pumps through a regenerator to the parabolic focus receiver, with the flow rate controlled by a valve to remain at critical level of 4.1 MPa. The valve changes the inlet pressure at the turbine nozzle block. Each concentrator would produce 76 kWth and 20 kWe. Dynamic variables in the logic account for insolation variation, fluid temperature, ac grid voltage, the thermal dynamics of the regenerator, and variations in the head supplied by the feed pump. Separate analyses are presented for the turbine shaft speed and toluene loop dynamics. The resulting logic is considered preliminary and suitable only in full insolation conditions. Extension of the model to nonlinear perturbations is indicated.

Bergthold, F. M., Jr.↗

The DE-AC accelerator system for high beam current density

A radically different ion accelerator system design has been developed to increase the extracted beam current density of ion thrusters. By independently controlling plasma ion extraction and acceleration, the Decoupled Extraction and Amplified Current (DE-AC) accelerator system gives higher beam currents at lower electric field stress levels. Results are presented for DE-AC grid system operation with the Test Bed Ion Engine. Using argon propellant, feasibility of a 60 mA/sq cm beam current density is shown. A discussion of power supply requirements, specific impulse operation and grid system geometrical design is presented also.

Aston, G.↗

A Time-Domain Protection Approach for AC Transmission Systems With Grid-Forming Resources

Ac transmission protection must reliably detect, classify, and locate short-circuit faults from voltage and current measurements. At present, these functionalities, which have been classically engineered using phasors approaches, are being challenged by the dynamic behavior and fault-current limits of converter-based generation. This paper tackles these challenges by engineering a time-domain protection approach that leverages the classical Bergeron model in a new manner. Low- and high-impedance faults are detected and classified by ascertaining how well line voltage and current measurements match the Bergeron equations. Faults are located by posing a novel one-variable optimization problem, whereas voltage and current waveforms at the fault location are estimated by unveiling rigorous relationships. The proposed elements are secure against external faults, measurement errors, and variation of line parameters and sampling time. Furthermore, these advances are tested via electromagnetic transient simulations and are significant to satisfy IEEE and North American Electric Reliability Corporation requirements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The SURE House (Solar Decathlon 2015)

Coastal towns and cities across the Northeastern US, with their high population density, aged utility infrastructure, and unique geography, are increasingly vulnerable to climate change related storm events. In October 2012 superstorm Sandy highlighted the fragility of our current coastal building types and made clear the need for a new model of design and construction which works to understand and mitigate these weaknesses. Dramatic changes in public policy, championed by both The Federal Emergency Management Agency (FEMA) and the National Flood Insurance Program (NFIP) are driving the rebuilding of these shore communities, often resulting in costly renovations, un-sustainable neighborhood configurations and in direct conflict with concurrent government policies such as The American with Disabilities Act (ADA). The SURE HOUSE demonstrates a series of new design solutions to these conflicting public policies and environmental imperatives. At Stevens Institute of Technology, the 2015 Solar Decathlon started with the challenge: Can we design a home for coastal New Jersey that dramatically reduces its energy use while protecting itself from the realities of a changing, more extreme climate? The SURE HOUSE merges the iconic 20th century shore home with 21st century building science. Utilizing innovative renewable energy technologies, a ‘Passive House’ level building envelope, and rugged glass-fiber-composite materials to flood-proof the home, the SURE HOUSE is a high-performance, net-zero-energy home, armored against extreme weather, designed for the contemporary lifestyle of the Jersey Shore and other vulnerable coastal communities. SUSTAINABLE At Stevens, we recognize that energy use in the home and workplace is directly connected to the growing problem of climate change. Reducing our energy consumption by designing higher performing, compact homes that are both functional, comfortable and desirable is the first critical step towards a modern, sustainable architecture for New Jersey and beyond. This is what informed the architectural design of the house. Configured about a compact form, thickly insulated and air-sealed walls eliminate thermal bridging and minimize energy losses while advanced glazing brings in free solar heat during the winter months. As a result of these passive design strategies, the SURE HOUSE has a greatly reduced carbon footprint requiring 91% less energy than a typical New Jersey home. Photovoltaic (PV) arrays on both the rooftop and operable shutters easily provide energy in excess of the home’s modest demands. The Stevens team considers a truly sustainable home in the era of climate change, one that prioritizes low energy use, and integrates right-sized renewable generation to supply the home’s needs. Low consumption, low production. RESILIENT In October of 2012, Hurricane Sandy wreaked havoc along the east coast of the US. In New Jersey alone there was an estimated 29.4 billion dollars in damages, 346,000 homes affected, and almost two and a half million people left without power, in some cases for over 10 days. Recovery from this storm and associated flooding is ongoing to this day, as many New Jersey homeowners grapple with the large costs of rebuilding and struggle to adapt to complicated new home building regulations. Damage from this storm to Hoboken, the home of the Stevens Institute of Technology’s campus, and to the New Jersey shore was extensive and many students on the SURE HOUSE team were directly affected by this historic event. The Stevens design team recognizes that in a world of more frequent and stronger storms, the ability to absorb and adapt to change is more important than ever. Successfully weathering the next storm and its aftermath is one of the primary goals in the design of the SURE HOUSE prototype. The SURE HOUSE introduces unique ‘dry flood-proofing’ methods to residential construction. Innovative wall and floor flood-proofing, utilizing durable composite sheathing materials adapted from the boating industry, were developed by the student team to render the SURE House’s building envelope flood proof up to the FEMA AE 6/7 Zone (+ 6/7 feet of water above sea-level). Designed and fabricated utilizing glass-fiber composite materials, the custom storm shutter system serves to protect the large glazed openings of the home from both air-borne debris impact and water infiltration during a storm event while also providing deterrence from the vandalism that often occurs in the aftermath of a calamitous event. During extended power outages, a ‘resilient’ solar array is capable of supplying critical amounts of energy and hot water to the home, without the use of battery storage or grid infrastructure. PV Description AC GRID-TIED PV SYSTEM The SURE HOUSE solar system consists of two distinct arrays, the grid-tied rooftop array which produces AC Powerand the shutter-mounted array which converts DC power generated by the modules directly into usable heat for the domestic hot water (DHW). The roof-mounted AC grid-tied array is comprised of three strings, two 11 module strings connected to an SMA SB 5000TL-US-223 inverter and a single 10 module string equipped and an SMA SB 3000TL-US-22 central inverter. All modules for the rooftop AC array are LG MonoX 2804 watt solar panels, chosen for their durability and efficiency. Inverter sizing and string size are optimized to the electrical characteristics of the chosen PV modules and the desired energy production, see Appendix 5B. The SURE HOUSE is projected to produce 12,353 kWh per year to meet 6,157 kWh per year of estimated consumption. Solar modules for the two AC grid-tied sub arrays are mounted on the main roof surface of the SURE HOUSE with a 10 degree tilt angle using a partially-ballasted polyethylene roof mounting system made by Renusol, which is particularly suited to the corrosive salt air of a coastal environment. This method was chosen for its installation simplicity and to limit detrimental roof penetrations. The 10 degree tilt optimizes the energy generated per roof area at a lower price, see Appendix 5A, and ensures that there is minimal wind uplift. DC SOLAR ELECTRIC DOMESTIC HOT WATER The SURE HOUSE’s approach to sustainable and resilient domestic hot water (DHW) consists of a unique, custom engineered DC solar electric hot water system. Employing the use of Advanced Energy’s DC electric PV heater (DCPVH)5 to heat domestic water well beyond the draw temperature, the SURE HOUSE is able to obtain a remarkably high solar fraction of 75% or more. The custom modified 80 gallon Vaughn DHW tank acts as a large solar ‘battery’ that stores heat energy in the form of hot water at almost 150 degrees, harvesting energy when the sun is out for use later in the day or overnight. The system, which uses electricity rather than heated fluid, is distinct from traditional ‘solar thermal’ systems by eliminating the dangers and associated maintenance issues of fluid based systems. By forgoing the use of external fluid loops, overheated solar collectors and pipes are not an issue for the SURE HOUSE system which never needs any yearly or seasonal flushing. In weather conditions where the integrated DCPVH unit cannot produce enough hot water via solar energy alone, the Vaughn hot water tank comes factory made with an AC powered 2.6 COP heat pump and a AC heating coil that serve as back-up heating elements. The DCPVH is powered by a DC array consisting of 10 custom-made Solbian by PVilion 180 watt, monocrystalline, flexible solar modules6. The Solbian modules are directly mounted to the top half of the operable storm shutters on the south façade of the SURE HOUSE. The SURE HOUSE team worked closely with PVillion, a PV system designer specializing in flexible architectural photovoltaics, to design an adhesive system that works with the glass-fiber storm shutter surface in a reliable manner over an extended period. Because this system operates in DC-only mode and never connects to the municipal power grid, the system can continue to create hot water safely and effectively even during grid disruption events. This hot water, and the energy stored within it, could be used for a range of activities including washing and cooking to more elaborate hydronic heating systems as desired. See Appendix 6 for system engineering, sizing and modeling.

14 SOLAR ENERGY↗

State-Constrained Grid-Forming Inverter Control for Robust Operation of AC Microgrids

The control of grid-forming inverters has become an important problem to achieve high efficiency, reliability, and resilience of the future power grid. The distributed control that utilizes a sparse communication network has been proposed for AC microgrids, in which each DG only has access to the information of a small number of its neighboring DGs, reducing the computational complexity and improving the resiliency to faults and unknown parameters. However, these approaches have not provided a clear analysis of the coupling between active/reactive power injections and the voltage magnitude/frequency or a distributed updating law with a solid theoretical foundation. Additionally, in the existing approaches, tracking the references from the secondary control may violate operational constraints.

Xu, Ying↗

Models and Methods for Assessing the Value of HVDC and MVDC Technologies in Mondern Power Grids

Evolution of today’s predominantly alternating current (ac) transmission grid in to mixed ac transmission – high-voltage direct current (HVdc) systems is expected with the decreasing costs of and advancements in power electronics technologies. The recent technological advancements include the development of more efficient and compact voltage source converters (VSCs) that can provide fast response. Because of their controllability and fast response, HVdc systems provide the ability to enhance reliability of the ac transmission grid through frequency support, voltage control, and congestion relief. The HVdc systems can also provide other ancillary services to enhance the economics and reliability of the ac transmission grids, and to optimize their performance. The tools, models, and methods developed to evaluate their benefits will be key enablers to understanding the value proposition introduced by the fast-acting HVdc systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Converter topologies for common mode voltage reduction

An inverter includes a three-winding transformer, a DC-AC inverter electrically coupled to the first winding of the transformer, a cycloconverter electrically coupled to the second winding of the transformer, and an active filter electrically coupled to the third winding of the transformer. The DC-AC inverter is adapted to convert the input DC waveform to an AC waveform delivered to the transformer at the first winding. The cycloconverter is adapted to convert an AC waveform received at the second winding of the transformer to the output AC waveform having a grid frequency of the AC grid. The active filter is adapted to sink and source power with one or more energy storage devices based on a mismatch in power between the DC source and the AC grid. At least two of the DC-AC inverter, the cycloconverter, or the active filter are electrically coupled via a common reference electrical interconnect.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Novel Three Phase Oak Ridge DC / AC Converter for Wireless Grid Tied Applications

In this study, a novel three phase oak ridge dc to ac converter is introduced for wireless mobility energy storage (WMES) applications to support the grid demand during peak times. The proposed topology can be used in a bi-directional operation between ac grid and dc terminals of energy storage by accomplishing unity power factor. Inherent merit of the technology can directly merge dc input to the high frequency and 60 Hz grid frequency by superimposing through the wireless coils. Theoretical and simulation results are validated by the simulation analysis for 20 kW output power. The functionality of the proposed three phase system is established by using 6 inches air gap between the couplers with the input of 675 V DC and output of 277 V AC, RMS . The system overall design analysis is demonstrated for simulation analysis and simulation results are presented achieving 3% current total harmonic distortion (THD) and 0.99 power factor (PF) at full load 20 kW wireless power transfer.

Asa, Erdem↗

Converter topologies and control

An inverter includes a transformer that includes a first winding, a second winding, and a third winding, a DC-AC inverter electrically coupled to the first winding of the transformer, a cycloconverter electrically coupled to the second winding of the transformer, an active filter electrically coupled to the third winding of the transformer. The DC-AC inverter is adapted to convert the input DC waveform to an AC waveform delivered to the transformer at the first winding. The cycloconverter is adapted to convert an AC waveform received at the second winding of the transformer to the output AC waveform having a grid frequency of the AC grid. The active filter is adapted to sink and source power with one or more energy storage devices based on a mismatch in power between the DC source and the AC grid.