Search NASA⌕ Search

SEARCH · Search NASA

Results for “ACOUSTIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Acoustic Measurements of Rectangular Nozzles with Bevel

A series of convergent rectangular nozzles of aspect ratios 2:1, 4:1, and 8:1 were constructed with uniform exit velocity profiles. Additional nozzles were constructed that extended the wide lip on one side of these nozzles to form beveled nozzles. Far-field acoustic measurements were made and analyzed, and the results presented. The impact of aspect ratio on jet noise was similar to that of enhanced mixing devices: reduction in aft, peak frequency noise with an increase in broadside, high frequency noise. Azimuthally, it was found that rectangular jets produced more noise directed away from their wide sides than from their narrow sides. The azimuthal dependence decreased at aft angles where noise decreased. The effect of temperature, keeping acoustic Mach number constant, was minimal. Since most installations would have the observer on the wide size of the nozzle, the increased high frequency noise has a deleterious impact on the observer. Extending one wide side of the rectangular nozzle, evocative of an aft deck in an installed propulsion system, increased the noise of the jet with increasing length. The impact of both aspect ratio and bevel length were relatively well behaved, allowing a simple bilinear model to be constructed relative to a simple round jet.

Bridges, James E.↗

Evaluation of the Acoustic Measurement Capability of the NASA Langley V/STOL Wind Tunnel Open Test Section with Acoustically Absorbent Ceiling and Floor Treatments

The single source location used for helicopter model studies was utilized in a study to determine the distances and directions upstream of the model accurate at which measurements of the direct acoustic field could be obtained. The method used was to measure the decrease of sound pressure levels with distance from a noise source and thereby determine the Hall radius as a function of frequency and direction. Test arrangements and procedures are described. Graphs show the normalized sound pressure level versus distance curves for the glass fiber floor treatment and for the foam floor treatment.

Theobald, M. A.↗

Electric Motor Noise for Small Quadcopters: Part I - Acoustic Measurements

There is increased interest in using electric motors to drive propulsors across a range of small air vehicle classes. Applications include both vertical lift and conventional takeoff and landing systems for Small Unmanned Aircraft Systems. Mission profiles call for integrating these systems into urban airspaces exposing populated areas to new noise sources. In addition to the propulsor noise from rotors and propellers, electric motors are expected to contribute to the overall sound levels and possibly human annoyance. This work presents acoustic measurements of electric motors used for small quadcopters to characterize the sound and identify sources with and without a propeller. Free field microphone measurements were used to determine directivity and a phased microphone array was used to identify sound sources. A companion paper (Part II – Source Characteristics and Prediction) compares the far field results with current probe measurements of the signal driving the motor, the structural response of the motor case, and describes prediction methods of electric motor noise.

Aircraft Noise↗

Electric Motor Noise from Small Quadcopters: Part 1 - Acoustic Measurements

There is increased interest in using electric motors to drive propulsors across a range of small air vehicle classes. Applications include both vertical lift and conventional takeoff and landing systems for Small Unmanned Aircraft Systems. Mission profiles call for integrating these systems into urban airspaces exposing populated areas to new noise sources. In addition to the propulsor noise from rotors and propellers, electric motors are expected to contribute to the overall sound levels and possibly human annoyance. This work presents acoustic measurements of electric motors used for small quadcopters to characterize the sound and identify sources with and without a propeller. Free field microphone measurements were used to determine directivity and a phased microphone array was used to identify sound sources. A companion paper (Part II - Source Characteristics and Prediction) compares the far field results with current probe measurements of the signal driving the motor, the structural response of the motor case, and describes prediction methods of electric motor noise.

Electric Propulsion↗

Acoustic measurements of the X-wing rotor

Noise measurements of a stoppable X-wing rotor system model, tested in the Ames 40- by 80-foot wind tunnel, are summarized. Performance, control system stability, and noise of the model were investigated at various forward speeds, tip speeds, collective blade angles, jet blowing velocities, and model attack angles. The model was tested in the rotating wing helicopter configuration, in the fixed wing configuration, and in wing configurations between the two. Noise data obtained in the helicopter configuration at the two highest tip speeds (Mach 0.44 and 0.47) and at wind tunnel speeds below 140 knots are reported. Test configuration and performance information are included. General acoustic measurements (dB, dBA, and PNdB) at six microphone locations are presented for all conditions under which the background noise was below the model noise. More specific measurements (1/3-octave and blade passage frequency harmonic levels) are presented for selected conditions. Graphs of dBA and 1/3-octave spectra, which show the noise trends as functions of operating condition, are included. The noise depends mainly on the jet blowing velocity. The noise levels were highest at moderate jet blowing velocities, less at the highest velocity, and lowest with no blowing at all.

Mosher, M.↗

Interferometer for Measuring Acoustic Signals

Optical-fiber interferometer measures wave amplitude without contacting specimen surface. System contains remote detector head. Head includes beam splitter that divides input beam and recombines output beams, while spatial filter filters interference pattern at beam-splitter output; and lens focuses this on detector. Beams focused on specimen surface to record acoustic signals.

Claus, R. O.↗

Acoustic measurements of three Prop-Fan models

Results of NASA sponsored acoustic tests of three 2 ft. diameter models of the Prop-Fan (a small diameter, highly loaded, many-bladed variable pitch advanced turboprop) are presented. The highly swept model designed for noise reduction produces substantially less near field noise at simulated 0.8 Mach number cruise conditions than the unswept or slightly swept models. It also produces less far field noise at conditions simulating takeoff and landing. The noise reduction mechanism is discussed. Correlation between harmonic noise measurements and theoretical predictions and between measured and predicted acoustic pressure pulses is good. Shadowgraph measurements which show the location of blade associated wave patterns were obtained. Predicted and measured wave locations show good general agreement. Full scale near and far field noise is predicted.

Brooks, B. M.↗

Acoustic Measurements for Small Solid Rocket Motors

Models have been developed to predict large solid rocket motor acoustic loads based on the scaling of small solid rocket motors. MSFC has measured several small solid rocket motors in horizontal and launch configurations to anchor these models. Solid Rocket Test Motor (SRTM) has ballistics similar to the Reusable Solid Rocket Motor (RSRM) therefore a good choice for acoustic scaling. Acoustic measurements were collected during the test firing of the Insulation Configuration Extended Length (ICXL) 7,6, and 8 (in firing order) in order to compare to RSRM horizontal firing data. The scope of this presentation includes: Acoustic test procedures and instrumentation implemented during the three SRTM firings and Data analysis method and general trends observed in the data.

Vargas, Magda B.↗

Directional acoustic measurements by laser Doppler velocimeters

Laser Doppler velocimeters (LDVs) are used as velocity microphones to measure sound pressure level in the range from 90 to 130 dB, spectral components, and two-point correlation functions for acoustic-noise source identification. Close agreement between LDV and microphone data is observed. Directional sensitivity and the ability to measure remotely make LDVs useful tools for acoustic measurement where placement of any physical probe is difficult or undesirable, as in the diagnosis of jet noise.

Mazumder, M. K.↗

Directional acoustic measurements by laser Doppler velocimeters

Laser Doppler velocimeters (LDVs) were used as velocity microphones to measure sound pressure level in the range of 90-130 db, spectral components, and two-point cross correlation functions for acoustic noise source identification. Close agreement between LDV and microphone data is observed. It was concluded that directional sensitivity and the ability to measure remotely make LDVs useful tools for acoustic measurement where placement of any physical probe is difficult or undesirable, as in the diagnosis of jet aircraft noise.

Mazumder, M. K.↗

Design and Analyses of High Aspect Ratio Nozzles for Distributed Propulsion Acoustic Measurements

A series of three convergent, round-to-rectangular high aspect ratio (HAR) nozzles were designed for acoustic testing at the NASA Glenn Research Center Nozzle Acoustic Test Rig (NATR). The HAR nozzles had exit area aspect ratios of 8:1, 12:1, and 16:1. The nozzles were designed to mimic a distributed propulsion system array with a slot nozzle. The nozzle designs were screened using Reynolds-Averaged Navier-Stokes (RANS) simulations. In addition to meeting the geometric constraints required for testing in the NATR, the HAR nozzles were designed to be free of flow features that would produce unwanted noise (e.g., flow separations) and to have uniform flow at the nozzle exit. Multiple methods were used to generate HAR nozzle designs. The final HAR nozzle designs were generated in segments using a computer code that parameterized each segment. RANS screening simulations showed that intermediate nozzle designs suffered flow separation, a normal shockwave at the nozzle exit (caused by an aerodynamic throat produced by boundary layer growth), and non-uniform flow at the nozzle exit. The RANS simulations showed that the final HAR nozzle designs were free of flow separations, but were not entirely successful at producing a fully uniform flow at the nozzle exit. The final designs suffered a pair of counter-rotating vortices along the outboard walls of the nozzle. The 16:1 aspect ratio HAR nozzle had the least uniform flow at the exit plane; the 8:1 aspect ratio HAR nozzles had a fairly uniform flow at the nozzle exit plane.

acoustic measure↗

Passive Wake Acoustics Measurements at Denver International Airport

From August to September 2003, NASA conducted an extensive measurement campaign to characterize the acoustic signal of wake vortices. A large, both spatially as well as in number of elements, phased microphone array was deployed at Denver International Airport for this effort. This paper will briefly describe the program background, the microphone array, as well as the supporting ground-truth and meteorological sensor suite. Sample results to date are then presented and discussed. It is seen that, in the frequency range processed so far, wake noise is generated predominantly from a very confined area around the cores.

Wang, Frank Y.↗

A description and some measured acoustic characteristics of the Langley 220 cubic meter reverberation chamber

An initial acoustic calibration was performed for the NASA Langley Research Center reverberation chamber located on the aircraft Noise Reduction Laboratory. The physical characteristics of the chamber and measured data for the ambient acoustic levels, reverberation times, reflection coefficients, the spatial uniformity of acoustic energy as measured in the 1/3-octave bands from 40 Hz to 10 KHz and acoustic power levels of a standard source are described. Measured power levels compared very well with those published for the ILG standard source. The measured data indicate that for broadband noise fields, the reverberation room has acceptable acoustic performance in the frequency range from 100 Hz to 8 KHz.

Mueller, A. W.↗

Acoustic Measurement Of Periodic Motion Of Levitated Object

Some internal vibrations, oscillations in position, and rotations of acoustically levitated object measured by use of microphone already installed in typical levitation chamber for tuning chamber to resonance and monitoring operation. Levitating acoustic signal modulated by object motion of lower frequency. Amplitude modulation detected and analyzed spectrally to determine amplitudes and frequencies of motions.

Watkins, John L.↗

Acoustic measurements of a full-scale coaxial helicopter

Acoustic data were obtained during a full-scale test of the XH-59A Advancing Blade Concept (ABC) Technology Demonstrator in the NASA Ames 40- by 80-Foot Wind Tunnel. The XH-59A is a research helicopter with two coaxial rotors and hingeless blades. Performance, vibration, noise at various forward speeds, rotor lift coefficients, and rotor shaft angles of attack were investigated. In general, the noise level is shown to increase with rotor lift coefficient except under certain operating conditions where it is increased by significant impulsive blade/vortex interactions. The impulsivity appears to depend upon how the lift is distributed between the two rotors. The noise levels measured are shown to be slightly higher than on a modern conventional rotor tested in the same facility.

Mosher, M.↗

Laser-Induced Thermal Acoustic Measurements in a Highly Back-Pressured Scramjet Isolator Model: A Research Plan

Under the Propulsion Discipline of NASA s Fundamental Aeronautics Program s Hypersonics Project, a test apparatus, for testing a scramjet isolator model, is being constructed at NASA's Langley Research Center. The test apparatus will incorporate a 1-inch by 2-inch by 15-inch-long scramjet isolator model supplied with 2.1 lbm/sec of unheated dry air through a Mach 2.5 converging-diverging nozzle. The planned research will incorporate progressively more challenging measurement techniques to characterize the flow field within the isolator, concluding with the application of the Laser-Induced Thermal Acoustic (LITA) measurement technique. The primary goal of this research is to use the data acquired to validate Computational Fluid Dynamics (CFD) models employed to characterize the complex flow field of a scramjet isolator. This paper describes the test apparatus being constructed, pre-test CFD simulations, and the LITA measurement technique.

Middleton, Troy F.↗

Acoustic measurement study 40 by 80 foot subsonic wind tunnel

An acoustical study conducted during the period from September 1, 1973 to April 30, 1974 measured sound pressure levels and vibration amplitudes inside and outside of the subsonic tunnel and on the tunnel structure. A discussion of the technical aspects of the study, the field measurement and data reduction procedures, and results are presentd, and conclusions resulting from the study which bear upon near field and far field tunnel noise, upon the tunnel as an acoustical enclosure, and upon the sources of noise within the tunnel drive system are given.

Source record↗

Non-Destructive Evaluation Method and Apparatus for Measuring Acoustic Material Nonlinearity

An acoustic non-linearity parameter (beta) measurement method and system for Non-Destructive Evaluation (NDE) of materials and structural members obviates the need for electronic calibration of the measuring equipment. Unlike known substitutional measuring techniques requiring elaborate calibration procedures, the electrical outputs of the capacitive detector of a sample with known beta and the test sample of unknown beta are compared to determine the unknown beta. In order to provide the necessary stability of the present-inventive reference-based approach, the bandpass filters of the measurement system are maintained in a temperature-controlled environment, and the line voltage supplied to said amplifiers is well-regulated.

William T Yost↗