Search NASA⌕ Search

SEARCH · Search NASA

Results for “ADAPTIVE CONTROL SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Decentralized Filtering Adaptive Neural Network Control for Uncertain Switched Interconnected Nonlinear Systems

This article presents a novel decentralized filtering adaptive neural network control framework for uncertain switched interconnected nonlinear systems. Each subsystem has its own decentralized controller based on the established decentralized state predictor. For each subsystem, the nonlinear uncertainties are approximated by a Gaussian radial basis function (GRBF) neural network incorporated with a piecewise constant adaptive law, where the adaptive law will update adaptive parameters from the error dynamics between the host system and the decentralized state predictor by discarding the unknowns, whereas a decentralized filtering control law is derived to cancel both local and mismatched uncertainties from other subsystems, as well as achieve the local objective tracking of the host system. The achievement of global objective depends on the achievement of local objective for each subsystem. The matched uncertainties are canceled directly by adopting their opposite in the control signal, whereas a dynamic inversion of the system is required to eliminate the effect of the mismatched uncertainties on the output. By exploiting the average dwell time principle, the error bounds between the real system and the virtual reference system, which defines the best performance that can be achieved by the closed-loop system, are derived. A numerical example is given to illustrate the effectiveness of the decentralized filtering adaptive neural network control architecture by comparing against the model reference adaptive control (MRAC).

Average dwell time, decentralized, filtering adapt↗

Innovative Patient Room Lighting System with Integrated Spectrally Adaptive Control

In December of 2013, the U.S. Department of Energy’s SSL R&D Program released a Funding Opportunity Announcement (FOA), that for the first time, contained opportunities for comprehensive application-specific system development. The FOA included opportunities for two applications, one of which was a Patient Room. Philips Lighting Research North America, submitted a proposal for the Patient Room application, and was selected for the complete project award. The award amount was for $497,127, with a Philips Research co-funding commitment 165,709 dollars. The total project value was 662,836 dollars. This project sought to redefine lighting for the patient room application. The goal was to deliver an innovative LED patient suite (patient room and bathroom) lighting system solution that was 40% more energy-efficient than traditional fluorescent incumbent technologies, and would meet all the visual and non-visual needs of patients, caregivers and visitors, and improve the patient experience. State-of-the-art multichannel LED platforms and control technologies that would provide spectral tuning and become part of an intelligent, connected lighting system drove the solution. The project was scoped into four main task areas that included a) System Concept Creation, b) Identification of the Luminaire Portfolio, c) Development of the Connected Lighting Infrastructure, and d) System Performance Validation. Each of the four main tasks were completed and validated extensively over the course the 2 ½ year project. The system concept was created by first developing a lighting design that demonstrated best practices for patient room lighting – illuminance and uniformity for task performance, reduced glare, and convenient controls, in addition to giving patients control over the lighting in their environment. A framework was defined to deliver circadian support via software behaviors. Through that process luminaires were identified from the Philips portfolio that were adaptable – by their form, dimensions, and optical materials – to mix multicolor LED platforms uniformly and deliver target design lumen levels. The Blue Sky luminaire was selected for the patient bed area to give the illusion of skylight while providing white light on the patient bed. Luminaires used existing 2-channel tunable white LED boards, and newly developed 4-channel LED boards. Red-Orange, Blue, Green, and Blue-shifted Yellow LED chips were selected based on spectral characteristics and their ability to produce high quality white light. 4-channel Power over Ethernet (PoE) drivers were developed and firmware written so they would communicate with both 2- and 4-channel boards. These components formed the backbone of the connected lighting infrastructure. Software, flexible and nuanced in its complexity, was written to set behaviors for myriad lighting scenes in the room throughout the 24 hour day – and all could be overridden by manual controls. This included a dynamic tunable white program, three color changing automatic programs that simulated degrees of sunrise to sunset palettes, and an amber night lighting system that offered visual cues for postural stability to minimize the risk of falls. All programs were carefully designed to provide visual comfort for all occupants, support critical task performance for staff, and to support the patient’s 24hr rhythms. A full scale mockup room was constructed in the Philips Cambridge Lab. The lighting system was installed, tested and functionality demonstrated to ensure smooth operation of system components – luminaires, drivers, PoE switches, wall controls, patient remote, and daylight and occupancy sensors. How did the system perform? It met visual criteria, confirmed by calculations, simulations and measurements in the field. It met non-visual criteria, confirmed by setting circadian stimulus (CS) targets and performing calculations using the calculator developed by the Lighting Research Center. Finally, human factors validation studies were conducted to gain insight from real end users in the healthcare profession; surveys were administered, data analyzed, and audio comments captured. The general consensus was positive, with requests to pilot the system in their hospitals. The importance of the research completed under this grant is that it allowed the exploration and development of a unique lighting system, one that would deliver a blend of visual and non-visual criteria in patient room design for today’s healthcare environment. The research investigated the area of multichannel LED technology, multichannel Power over Ethernet (PoE) drivers and their integration with automatic and manual controls as a system – uncovering and meeting challenges along the way. It married visual needs of patients and staff with support for 24 hour rhythms, placing value on the wellbeing of the patient – while successfully saving energy over incumbent technologies. Indications are that the market is ready and willing to invest – multiple healthcare facilities are in line to pilot this system, recognizing its value beyond energy to patient and staff well-being. Its value to the public can best be expressed by a patient support coordinator who, after spending several hours in the room being immersed in the lighting, analyzing all its features, commented: “This re-writes lighting for healthcare”.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dedicated short range communications used as fail-safe in autonomous navigation

Here in this paper, we have analyzed scenarios for leader-follower vehicle convoys that have the potential to be unsafe, hazardous, or even fatal in order to provide insight on dangerous driving conditions for autonomous vehicle platoons. These scenarios were created in a simulation software called Prescan, and are made to reflect the behavior of the vehicle dynamics and sensor characteristics of a real-world vehicle convoy that is currently being tested at the American Center for Mobility (ACM) and sponsored by the Department of Energy (DOE), National Renewable Energy Laboratory (NREL), the U.S. Army Combat Capabilities Development Command - Ground Vehicle Systems Center (U.S. Army CC-DEVCOM) and the Michigan Department of Transportation (MDOT). The follower vehicle in this study is tested under multiple scenarios, equipped with a Dedicated Short Range vehicle-to-vehicle communication system (DSRC), a radar-based adaptive cruise control system (ACC) and a precision global positioning system (GPS).

42 ENGINEERING↗

A Data-Driven Voltage Control Strategy for Distribution Grids With Distributed Energy Resources

Traditionally, distribution system control approaches have been model-based. The deployment of advanced metering infrastructure has provided electric utilities with the capability of data-driven control with real-time measurements. The shift from model-based to data-driven control represents a significant advancement in the management of distribution systems, offering a more adaptive approach to system control because of the ability to dynamically adapt to changing conditions without the need for system modeling. Here, in this paper, a behavioral data-driven control method is developed to provide voltage regulation to an actual distribution system by controlling the legacy devices and distributed energy resource (DER) assets. The studied distribution system has a load tap changer and three capacitor banks as the legacy devices and photovoltaic systems as the DERs. The performance of the proposed control algorithm is validated using a laboratory test bed setup considering multiple scenarios. The results show that the proposed control achieved 99% voltage regulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Framework of Vehicle Dynamics, Instabilities, Energy Models, and Sparse Flow Smoothing Controllers

This work presents an integrated framework of: vehicle dynamics models, with a particular attention to instabilities and traffic waves; vehicle energy models, with particular attention to accurate energy values for strongly unsteady driving profiles; and sparse Lagrangian controls via automated vehicles, with a focus on controls that can be executed via existing technology such as adaptive cruise control systems. This framework serves as a key building block in developing control strategies for human-in-the-loop traffic flow smoothing on real highways. In this contribution, we outline the fundamental merits of integrating vehicle dynamics and energy modeling into a single framework, and we demonstrate the energy impact of sparse flow smoothing controllers via simulation results.

Lee, Jonathan W.↗

Data-Driven Forgetting and Discount Factors for Vehicle Speed Forecasting in Ecological Adaptive Cruise Control

Abstract This paper investigates temporal correlations in human driving behavior using real-world driving to improve speed forecasting accuracy. These correlations can point to a measurement weighting function with two parameters: a forgetting factor for past speed measurements that the vehicle itself drove with, and a discount factor for the speeds of vehicles ahead based on information from vehicle-to-vehicle communication. The developed weighting approach is applied to a vehicle speed predictor using polynomial regression, a prediction method well-known in the literature. The performance of the developed approach is then assessed in both real-world and simulated traffic scenarios for accuracy and robustness. The new weighting method is applied to an ecological adaptive cruise control system, and its influence is analyzed on the prediction accuracy and the performance of the ecological adaptive cruise control in an electric vehicle powertrain model. The results show that the new prediction method improves energy saving from the eco-driving by up to 4.7% compared to a baseline least-square-based polynomial regression. This is a 10% improvement over the constant speed/acceleration model, a conventional speed predictor.

Automation & Control Systems↗

Adapting the monitoring and control systems on the 300 MW power generation units at the Iriklinskaya GRES to modern operational requirements

Work done by JSC 'Interavtomatika' and the Iriklinskaya GRES (State Regional Electric Power Plant) to create automatic frequency and power control systems is reported. This involved reconstructing the turbine regulator systems and modernizing all the regulators for the power generator unit (those coupled to and those not coupled to the automatic frequency and power control systems) and the automatic burner control systems on the basis of a unified Simatic PCS7 PS controller system for the four 300 MW power generation units at the Iriklinskaya GRES.

13 HYDRO ENERGY↗

Network-Wide Traffic Signal Control Using Bilinear System Modeling and Adaptive Optimization

This study proposes a new multi-input multi-output optimal bilinear signal control method in which a bilinear dynamic model approximation is used to capture the nonlinear dynamics of the urban traffic networks. With signal green time splits as the control input and traffic delay changes as the output for each intersections in the network, a bilinear system model was developed, which, on the basis of linear system modeling, takes interactions among traffic delays and signal timing splits into consideration. Based on the bilinear system modeling framework, we conducted two steps in each time interval to derive traffic control strategies: (1) we used the normalized least-squared algorithm to estimate system parameters; and (2) we solved an online optimization problem to obtain the updated traffic control inputs for the signal timing that minimizes future traffic delays. We evaluated the proposed method in a microscopic traffic simulation environment (VISSIM) with a 35-intersection network of Bellevue city in Washington. Two different traffic demand patterns: (1) normal traffic demands; and (2) time-varying traffic demands were simulated to compare the performance of different control strategies. Experimental results show that (1) the proposed bilinear system model can better describe traffic system dynamics than linear-model based methods, such as our previously developed linear-quadratic regulator control; and (2) the proposed method outperforms the state-of-the-art signal control strategies, namely the max-pressure and the self-organizing traffic light control methods. We have also shown that the proposed method is applicable to all other possible network layouts and signal controller phasing structures.

42 ENGINEERING↗

Physics-Informed Evolutionary Strategy Based Control for Mitigating Delayed Voltage Recovery

Here, in this work we propose a novel data-driven, real-time power system voltage stability control method based on the physics-informed guided meta evolutionary strategy (ES). The main objective is to quickly provide an adaptive control strategy to secure system voltage stability. The problem is challenging due to the high-dimensional feature of the power system model and the fast-changing and uncertain nature of power system operation scenarios. To this end, a model-free and derivative-free guided ES method is applied. The method is further combined with a meta-learning strategy to make the learnt control policy automatically adapted to unseen operation conditions and fault scenarios, which is highly desired for real-time emergency control. Last but not least, physical knowledge is embedded in the above method through a trainable action mask technique to rule out unnecessary load shedding actions for better learning and control performance. Case studies on the IEEE 300-bus system and comparisons with other state-of-the-art benchmark methods verify the superiority of the proposed physics-informed guided meta ES method in realizing fast and adaptive power system voltage stability control.

42 ENGINEERING↗

Complete synchronization of uncertain chaotic systems via a single proportional adaptive controller: A comparative study

This paper addresses a comparative computational study on the synchronization quality, cost and converging speed for two pairs of identical chaotic and hyperchaotic systems with unknown time-varying parameters. It is assumed that the unknown time-varying parameters are bounded. Based on the Lyapunov stability theory and using the adaptive control method, a single proportional controller is proposed to achieve the goal of complete synchronizations. Accordingly, appropriate adaptive laws are designed to identify the unknown time-varying parameters. The designed control strategy is easy to implement in practice. Numerical simulations results are provided to verify the effectiveness of the proposed synchronization scheme.

42 ENGINEERING↗

String instability mitigation of adaptive cruise control without modifying control laws: trajectory shaper and parameter estimation

Vehicle automation technologies equip vehicles with adaptive cruise control (ACC) systems, which relieve driving fatigue. However, recent studies have shown that the current ACC systems are string-unstable (i.e., exacerbate traffic congestion). To achieve string stability, most existing studies directly modify the control algorithms of ACC systems. Alternatively, this study proposes a trajectory shaper (TS)-based method, which only modifies the trajectory information of the predecessor vehicle, so that the ego vehicle driven by a string-unstable ACC system leverages the modified trajectory information to achieve string stability. To devise the TS-based method, an offline-online parameter estimation method integrating batch optimization and an extended Kalman filter is applied to estimate the parameters of an ACC system. The proposed TS-based method is cost-effective during implementation, as it avoids modifying existing ACC control algorithms (which entails a complex analysis of control systems and parameter tuning). In conclusion, the effectiveness of the proposed TS-based method is validated through extensive numerical experiments.

33 ADVANCED PROPULSION SYSTEMS↗

LLE'S high-pressure DT-fill process control system

The OMEGA laser at the Univ. of Rochester's Laboratory for Laser Energetics (UR/LLE) implodes fusion targets that contain cryogenic solid deuterium-tritium (DT) ice layers. These ICF targets are fabricated in a high-pressure DT-fill process. This paper describes the integration and control of this DT-fill process. The appropriate safety-control response during the DT-fill process depends on the location of the tritium inventory and where the containment alarm is detected. A control response that is deemed appropriate earlier in the fill process could be a dangerous action at a later point in the fill process. The control system must adapt as the DT inventory moves through the process train. This is achieved by defining eight 'fill states' in the fill process. The control system transitions to the appropriate fill state as the DT fill progresses. The fill state reflects the tritium location, pressure, and temperature. Steps are taken to ensure that the tritium location and the fill state are in agreement. The control system monitors the containment system's integrity and will take the appropriate action, based on the tritium location and the type of containment failure. This approach not only ensures process safety, but also maximizes the productivity by executing process pauses (in lieu of aborts) when conditions allow. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LLE's High-Pressure DT-Fill Process Control System

The OMEGA Laser at the University of Rochester's Laboratory for Laser Energetics (UR/LLE) implodes fusion targets that contain cryogenic solid deuterium-tritium (DT) ice layers. These ICF targets are fabricated in a high-pressure DT-fill process. This paper describes the integration and control of this DT-fill process. The appropriate safety-control response during the DT-fill process depends on the location of the tritium inventory and where the containment alarm is detected. A control response that is deemed appropriate earlier in the fill process could be a dangerous action at a later point in the fill process. The control system must adapt as the DT inventory moves through the process train. This is achieved by defining eight "fill states" in the fill process. The control system transitions to the appropriate fill state as the DT fill progesses. The fill state reflects the tritium location, pressure, and temperature. Steps are taken to ensure that the tritium location and the fill state are in agreement. The control system monitors the containment system's integrity and will take the appropriate action, based on the tritium location and the type of containment failure. This approach not only ensures process safety, but also maximizes the productivity by executing process pauses (in lieu of aborts) when conditions allow.

Duffy, T↗

Adaptive Online Model Update Algorithm for Predictive Control in Networked Systems

In this article, we introduce an adaptive on-line model update algorithm designed for predictive control applications in networked systems, particularly focusing on power distribution systems. Unlike traditional methods that depend on historical data for offline model identification, our approach utilizes real-time data for continuous model updates. This method integrates seamlessly with existing online control and optimization algorithms and provides timely updates in response to real-time changes. This methodology offers significant advantages, including a reduction in the communication network bandwidth requirements by minimizing the data exchanged at each iteration and enabling the model to adapt after disturbances. Furthermore, our algorithm is tailored for non-linear convex models, enhancing its applicability to practical scenarios. The efficacy of the proposed method is validated through a numerical study, demonstrating improved control performance using a synthetic IEEE test case.

data-driven model predictive control↗

Adaptive Voltage Control with Distributed Energy Resources: Algorithm, Theoretical Analysis, Simulation and Field Test Verification

Abstract Distributed energy resources (DE) or distributed generators (DG) with power electronics interfaces and logic control using local measurements are capable of providing reactive power related ancillary system services. In particular, local voltage regulation has drawn much attention in regards to power system reliability and voltage stability, especially from past major cascading outages. This paper addresses the challenges of controlling DEs to regulate local voltage in distribution systems. An adaptive voltage control method has been proposed to dynamically modify control parameters to respond to system changes. Theoretical analysis shows that there exists a corresponding formulation of the dynamic control parameters; hence the adaptive control method is theoretically solid. Both simulation and field experiment test results at the Distributed Energy Communications and Controls (DECC) Laboratory confirm that this method is capable of satisfying the fast response requirement for operational use without causing oscillation, inefficiency, or system equipment interference. Since this method has a high tolerance to real-time data shortage and is widely adaptive to variable power system operational situations, it is quite suitable for broad utility application.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Vision–based Robust $\mathcal{H}$ ∞ Gain Scheduling Longitudinal and Lateral Following Controller for Autonomous Vehicles on Urban Curved Roads

Implementing advanced driver assistance systems (ADAS) in congested and intricate urban traffic scenarios poses significant challenges. To address the frequent stop–and–go motions exhibited by autonomous vehicles (AVs) navigating urban roads with changes in curvature, we propose a vision–based robust $\mathcal{H}$ ∞ adaptive cruise control system (ACC) for longitudinal control, plus a lane keeping assist system (LKAS) for lateral control. For the vision-based ACC, a weighted probability objective function for the vehicle following behavior is formulated. We incorporate $\mathcal{H}$ ∞ performance and gain scheduling techniques to mitigate the impact of uncertainty in visual sensor measurements. Furthermore, the optimal time headway is scheduled based on the velocity to ensure traffic flow efficiency and safety during the vehicle following process. For the LKAS, we introduce a road curvature estimation method that integrates lane and vehicle dynamics information to obtain the lateral and heading offsets. Next, the design criterion of the observer–based robust gain scheduling lateral motion controller is established by linear matrix inequality (LMI). Here, a series of experiments conducted within a camera–in–loop platform validate the proposed method.

33 ADVANCED PROPULSION SYSTEMS↗

Chaos control for the output-constrained system by using adaptive dynamic surface technology and application to the brushless DC motor

In this paper, chaos control is proposed for the output- constrained system with uncertain control gain and time delay and is applied to the brushless DC motor. Using the dynamic surface technology, the controller overcomes the repetitive differentiation of backstepping and boundedness hypothesis of pre-determined control gain by incorporating radial basis function neural network and adaptive technology. The tangent barrier Lyapunov function is employed for time-delay chaotic system to prevent constraint violation. It is proved that the proposed control approach can guarantee asymptotically stable in the sense of uniformly ultimate boundedness without constraint violation. Finally, the effectiveness of the proposed approach is demonstrated on the brushless DC motor example.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Concepts for Autonomous Operation of Microreactors

Microreactor concepts have seen increasing interest in recent years given their potential use for meeting energy needs in remote and grid-isolated communities. Given the small power outputs of microreactors and the potential for remote siting, there is a need to reduce operational staffing levels to improve their economic viability. A key enabling technology for this purpose is autonomous control that enables autonomous operation of microreactors. While several options for autonomous control exist, the level of human operator involvement in operational decision making needs to be defined as part of the system design process. Once this separation of function is achieved, several options exist for autonomous control ranging from simple automation of some procedures to fully autonomous operational mode decision making and execution.A critical aspect of autonomous decision making is the ability to have as complete an awareness of the system state as possible. In addition to data on temperature, pressure, flow, and neutron flux, measurements of the condition of important components will be necessary. This type of information will allow the autonomous control system to adapt its decision making to any changing conditions within the reactor, thereby not compromising safety while continuing to operate for as long as possible. Several technical advances are needed before widespread use of autonomous control in microreactors. These include sensor and instrumentation technologies that are capable of long term, unattended operation in harsh environments, technologies for inferring the state of the microreactor system or subsystems in an automated fashion, algorithms for predictive decision making that account for the assessed condition of the microreactor subsystems as well as the potential impact on those components of any operational decision, and actuators and control system hardware that are also long-lived in a harsh environment. In addition, given the need to remotely monitor the operations, cybersecurity requirements will likely need to be imposed to ensure secure operations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗