Search NASA⌕ Search

SEARCH · Search NASA

Results for “ADMINISTRATIVE PROCEDURES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Continuous Monitoring and Intrafraction Target Position Correction During Treatment Improves Target Coverage for Patients Undergoing SBRT Prostate Therapy

Purpose: To compare the potential benefits of continuous monitoring of prostate position and intervention (CMI) using 2-mm displacement thresholds during stereotactic body radiation therapy (SBRT) treatment to those of a conventional image-guided procedure involving single localization prior to treatment. Methods and Materials: Eighty-nine patients accrued to a prostate SBRT dose escalation protocol were implanted with radiofrequency transponder beacons. The planning target volume (PTV) margin was 5 mm in all directions, except for 3 mm in the posterior direction. The prostate was kept within 2 mm of its planned position by the therapists halting dose delivery and, if necessary, correcting the couch position. We computed the number, type, and time required for interventions and where the prostate would have been during dose delivery had there been, instead, a single image-guided setup procedure prior to each treatment. Distributions of prostate displacements were computed as a function of time. Results: After the initial setup, 1.7 interventions per fraction were required, with a concomitant increase in time for dose delivery of approximately 65 seconds. Small systematic drifts in prostate position in the posterior and inferior directions were observed in the study patients. Without CMI, intrafractional motion would have resulted in approximately 10% of patients having a delivered dose that did not meet our clinical coverage requirement, that is, a PTV D95 of >90%. The posterior PTV margin required for 95% of the dose to be delivered with the target positioned within the PTV was computed as a function of time. The margin necessary was found to increase by 2 mm every 5 minutes, starting from the time of the imaging procedure. Conclusions: CMI using a tight 2-mm displacement threshold was not only feasible but was found to deliver superior PTV coverage compared with the conventional image-guided procedure in the SBRT setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-G-BRC-00: Experiences with TG100 in Clinical Use

Failure Mode and Effects Analysis (FMEA) originated as an industrial engineering technique used for risk management and safety improvement of complex processes. In the context of radiotherapy, the AAPM Task Group 100 advocates FMEA as the framework of choice for establishing clinical quality management protocols. However, there is concern that widespread adoption of FMEA in radiation oncology will be hampered by the perception that implementation of the tool will have a steep learning curve, be extremely time consuming and labor intensive, and require additional resources. To overcome these preconceptions and facilitate the introduction of the tool into clinical practice, the medical physics community must be educated in the use of this tool and the ease in which it can be implemented. Organizations with experience in FMEA should share their knowledge with others in order to increase the implementation, effectiveness and productivity of the tool. This session will include a brief, general introduction to FMEA followed by a focus on practical aspects of implementing FMEA for specific clinical procedures including HDR brachytherapy, physics plan review and radiosurgery. A description of common equipment and devices used in these procedures and how to characterize new devices for safe use in patient treatments will be presented. This will be followed by a discussion of how to customize FMEA techniques and templates to one’s own clinic. Finally, cases of common failure modes for specific procedures (described previously) will be shown and recommended intervention methodologies and outcomes reviewed. Learning Objectives: Understand the general concept of failure mode and effect analysis Learn how to characterize new equipment for safety Be able to identify potential failure modes for specific procedures and learn mitigation techniques Be able to customize FMEA examples and templates for use in any clinic.

60 APPLIED LIFE SCIENCES↗

Promoting system-level learning from project-level lessons

A growing number of low and middle income nations (LMCs) have adopted some sort of system for environmental impact assessment (EIA). However, generally many of these EIA systems are characterised by a low performance in terms of timely information dissemination, monitoring and enforcement after licencing. Donor actors (such as the World Bank) have attempted to contribute to a higher performance of EIA systems in LMCs by intervening at two levels: the project level (e.g. by providing scoping advice or EIS quality review) and the system level (e.g. by advising on EIA legislation or by capacity building). The aims of these interventions are environmental protection in concrete cases and enforcing the institutionalisation of environmental protection, respectively. Learning by actors involved is an important condition for realising these aims. A relatively underexplored form of learning concerns learning at EIA system-level via project level donor interventions. This 'indirect' learning potentially results in system changes that better fit the specific context(s) and hence contribute to higher performances. Our exploratory research in Ghana and the Maldives shows that thus far, 'indirect' learning only occurs incidentally and that donors play a modest role in promoting it. Barriers to indirect learning are related to the institutional context rather than to individual characteristics. Moreover, 'indirect' learning seems to flourish best in large projects where donors achieved a position of influence that they can use to evoke reflection upon system malfunctions. In order to enhance learning at all levels donors should thereby present the outcomes of the intervention elaborately (i.e. discuss the outcomes with a large audience), include practical suggestions about post-EIS activities such as monitoring procedures and enforcement options and stimulate the use of their advisory reports to generate organisational memory and ensure a better information dissemination.

54 ENVIRONMENTAL SCIENCES↗

SU-E-J-161: Inverse Problems for Optical Parameters in Laser Induced Thermal Therapy

Purpose: Magnetic resonance-guided laser-induced thermal therapy (MRgLITT) is investigated as a neurosurgical intervention for oncological applications throughout the body by active post market studies. Real-time MR temperature imaging is used to monitor ablative thermal delivery in the clinic. Additionally, brain MRgLITT could improve through effective planning for laser fiber's placement. Mathematical bioheat models have been extensively investigated but require reliable patient specific physical parameter data, e.g. optical parameters. This abstract applies an inverse problem algorithm to characterize optical parameter data obtained from previous MRgLITT interventions. Methods: The implemented inverse problem has three primary components: a parameter-space search algorithm, a physics model, and training data. First, the parameter-space search algorithm uses a gradient-based quasi-Newton method to optimize the effective optical attenuation coefficient, μ-eff. A parameter reduction reduces the amount of optical parameter-space the algorithm must search. Second, the physics model is a simplified bioheat model for homogeneous tissue where closed-form Green's functions represent the exact solution. Third, the training data was temperature imaging data from 23 MRgLITT oncological brain ablations (980 nm wavelength) from seven different patients. Results: To three significant figures, the descriptive statistics for μ-eff were 1470 m{sup −1} mean, 1360 m{sup −1} median, 369 m{sup −1} standard deviation, 933 m{sup −1} minimum and 2260 m{sup −1} maximum. The standard deviation normalized by the mean was 25.0%. The inverse problem took <30 minutes to optimize all 23 datasets. Conclusion: As expected, the inferred average is biased by underlying physics model. However, the standard deviation normalized by the mean is smaller than literature values and indicates an increased precision in the characterization of the optical parameters needed to plan MRgLITT procedures. This investigation demonstrates the potential for the optimization and validation of more sophisticated bioheat models that incorporate the uncertainty of the data into the predictions, e.g. stochastic finite element methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Arterial Embolization with N-Butyl-2-Cyanoacrylate in the Management of Spontaneous Hematomas

IntroductionSpontaneous hematoma refractory to conservative management is a potentially serious condition that requires prompt diagnosis and intervention. The purpose of this study was to evaluate the performance of computed tomography (CT) in the treatment planning and to report the effectiveness of transcatheter embolization with N-butyl-2-cyanoacrylate (NBCA).Materials and MethodsForty-one interventions in 38 patients within a 12-year period were evaluated. CT and angiograms were reviewed for the location of the hematoma, the presence of extravasation, and the correlation of CT and angiography findings.ResultsArterial extravasation was present on 34/39 CT scans. Angiograms confirmed the CT scans in 29 cases. Angiograms revealed extravasation in four cases which CT showed venous bleeding (n = 2) or no bleeding (n = 2). Five patients with arterial and 1 patient with venous extravasation on CT images had no extravasation on angiograms. Embolization was performed to all arteries with extravasation on angiograms. Empiric embolization of the corresponding artery on the CT was performed when there was no extravasation on angiograms. Embolization procedures were performed with 15 % NBCA diluted with iodized oil. Technical success was achieved in 40/41 (97.6 %) interventions. Clinical success was achieved in 35 patients with a single, in 1 patient with 2, and in 1 patient with 3 interventions. No complications related to embolization procedure occurred. None of the patients died due to a progression of the hematoma.ConclusionNBCA is an effective and safe embolic agent to treat hematoma refractory to conservative management. Contrast-enhanced CT may provide faster and more effective intervention.Level of Evidence IIIRetrospective.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Microwave Ablation of Renal Angiomyolipomas

PurposeTo evaluate the safety and efficacy of US-guided percutaneous microwave (MW) ablation in the treatment of renal angiomyolipoma (AML).Materials and MethodsFrom January 2011 to April 2014, seven patients (5 females and 2 males; mean age 51.4) with 11 renal AMLs (9 sporadic type and 2 tuberous sclerosis associated) with a mean size of 3.4 ± 0.7 cm (range 2.4–4.9 cm) were treated with high-powered, gas-cooled percutaneous MW ablation under US guidance. Tumoral diameter, volume, and CT/MR enhancement were measured on pre-treatment, immediate post-ablation, and delayed post-ablation imaging. Clinical symptoms and creatinine were assessed on follow-up visits.ResultsAll ablations were technically successful and no major complications were encountered. Mean ablation parameters were ablation power of 65 W (range 60–70 W), using 456 mL of hydrodissection fluid per patient, over 4.7 min (range 3–8 min). Immediate post-ablation imaging demonstrated mean tumor diameter and volume decreases of 1.8 % (3.4–3.3 cm) and 1.7 % (27.5–26.3 cm{sup 3}), respectively. Delayed imaging follow-up obtained at a mean interval of 23.1 months (median 17.6; range 9–47) demonstrated mean tumor diameter and volume decreases of 29 % (3.4–2.4 cm) and 47 % (27.5–12.1 cm{sup 3}), respectively. Tumoral enhancement decreased on immediate post-procedure and delayed imaging by CT/MR parameters, indicating decreased tumor vascularity. No patients required additional intervention and no patients experienced spontaneous bleeding post-ablation.ConclusionOur early experience with high-powered, gas-cooled percutaneous MW ablation demonstrates it to be a safe and effective modality to devascularize and decrease the size of renal AMLs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cardiovascular and Interventional Radiological Society of Europe Guidelines on Endovascular Treatment in Aortoiliac Arterial Disease

Purpose: These guidelines are intended for use in assessing the standard for technical success and safety in aorto-iliac percutaneous endovascular interventions. Methods: Any recommendation contained in the text comes from the highest level and extension of literature review available to date. Results: The success of endovascular procedures is strictly related to an accurate planning based mainly on CT- or MR-angiography. TASC II A through C lesions have an endovascular-first option Pre-procedure ASA antiplatelet therapy is advisable in all cases. The application of stents improves the immediate hemodynamic and most likely long-term clinical results. Cumulative mean complication rate is 7.51 % according to the most relevant literature. Most of the complications can be managed by means of percutaneous techniques. Conclusion: The design and quality of devices, as well as the easy and accuracy of performing these procedures, have improved over the last decades, leading to the preferential treatment of aorto-iliac steno-obstructive disease via endovascular means, often as first-line therapy, with high technical success rate and low morbidity. This is mirrored by the decreasing number of patients undergoing surgical grafts over the last years with patency, limb salvage, and survival rates equivalent to open reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determinants of debit cards acceptance: An empirical investigation

These days, most of the Malaysians realize that the consumption of debit card will help them to reduce the household debt. Thus, it is important to analyse the acceptance of debit cards for further enhancement and expanding its market share in Malaysia. In addition, there is lacked of research being conducted on the determinants affecting the acceptance of debit cards among Malaysians. Thus, the study aimed to investigate the factors affecting the acceptance of debit cards. This study focuses on payment methods, consumer attitude, and safety of debit card in acceptance of debit cards. Questionnaires were distributed to the 300 respondents. The sampling procedure adopted was stratified random sampling. The data obtained were analysed using SPSS 20.0 which involves scale reliability, descriptive and regression analysis. The result indicates that payment methods, consumer attitude and safety are the determinants of debit cards acceptance. Safety is the best predictor as most of the customers are confidents to use debit cards because of the security being developed around these debit card transactions. The analyses presented in this study can be used by policymakers and managers as a guide to promote banking products and services. The findings achieved in this study will be of interest for practitioners and academics concerned with developments of the Malaysian banking industry.

99 GENERAL AND MISCELLANEOUS↗

Stentgraft Implantation for the Treatment of Postoperative Hepatic Artery Pseudoaneurysm

PurposeHepatic artery pseudoaneurysms are a rare but potentially life-threatening complication of major pancreaticobiliary surgery. We evaluated the safety and efficacy of endovascular stentgraft implantation for the management of such vascular lesions.Materials and MethodsBetween May 2013 and October 2015, ten patients with postoperative hepatic artery pseudoaneurysm, of which eight presented with active hemorrhage, were treated with endovascular stentgraft implantation. All patients had undergone major pancreatic or hepatic surgery before (pylorus-preserving pancreaticoduodenectomy, pancreatectomy, hemihepatectomy, extended hemihepatectomy). The pseudoaneurysms were diagnosed 13–202 days after surgery and were associated with postsurgical complications (e.g., leakage of pancreaticojejunal anastomosis).ResultsIn 9/10 patients, the pseudoaneurysm was completely excluded via stentgraft implantation. In 1/10 patient, the pseudoaneurysm ruptured during the procedure and was successfully treated by immediate open surgery. In 1/10 patient, a second intervention was performed after 6 days because of rebleeding; this was successfully treated by implantation of a second overlapping stentgraft. Mean follow-up time is 51 days. None of the patients died due to stentgraft- or aneurysm-related complications. Further episodes of hemorrhage were not observed. In one patient, clinically asymptomatic complete occlusion of the stentgraft was discovered at follow-up imaging.ConclusionStentgraft implantation is a safe and effective technique to treat hepatic artery pseudoaneurysms related to major pancreatic or hepatic surgery, especially in the setting of acute hemorrhage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structures of Al{sub n}, its anions and cations up to n=34: A theoretical investigation

A systematic density functional study has been performed for neutral and singly charged clusters of aluminum with up to 34 atoms. A thorough search for global minimum structures has been carried out for Al{sub n} employing genetic algorithm and basin-hopping procedures. For Al{sub n} this confirms results of previous investigations up to n=22; new global minima have been located for n=23-31, 33. Structures for singly charged cations and anions have been obtained by reoptimization of the pool of 40 low-energy structures of the neutral clusters. The global minima of charged and neutral clusters are always low-spin states with the possible exception of a triplet state of Al{sub 28}, which is isoenergetic with a singlet. The cluster structures are mostly quite irregular and do not resemble fractions of the fcc bulk phase. High symmetries are found only for the global minimum of Al{sub 23} and the triplet state of Al{sub 28}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Minimally Invasive Catheter Procedures to Assist Complicated Pacemaker Lead Extraction and Implantation in the Operating Room

We report on percutaneous catheter procedures in the operating room (OR) to assist complicated manual extraction or insertion of pacemaker (PM) and implantable cardioverter defibrillator leads. We retrospectively reviewed complicated PM revisions and implantations performed between 2004 and 2009 that required percutaneous catheter procedures performed in the OR. The type of interventional procedure, catheter and retrieval system used, venous access, success rates, and procedural complications were analyzed. In 41 (12 female and 29 male [mean age 62 {+-} 17 years]) of 3021 (1.4%) patients, standard manual retrieval of old leads or insertion of new leads was not achievable and thus required percutaneous catheter intervention for retrieval of misplaced leads and/or recanalisation of occluded central veins. Thirteen of 18 (72.2%) catheter-guided retrieval procedures for misplaced (right atrium [RA] or ventricle [RV; n = 3], superior vena cava [n = 2], brachiocephalic vein [n = 5], and subclavian vein [n = 3]) lead fragments in 16 patients were successful. Percutaneous catheter retrieval failed in five patients because there were extremely fixed or adhered lead fragments. Percutaneous transluminal angiography (PTA) of central veins for occlusion or high-grade stenosis was performed in 25 patients. In 22 of 25 patients (88%), recanalization of central veins was successful, thus enabling subsequent lead replacement. Major periprocedural complications were not observed. In the case of complicated manual PM lead implantation or revision, percutaneous catheter-guided extraction of misplaced lead fragments or recanalisation of central veins can be performed safely in the OR, thus enabling subsequent implantation or revision of PM systems in the majority of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Arterial Embolization for Hepatic Arterial Injury Related to Percutaneous Transhepatic Portal Intervention

PurposeTo assess the usefulness of transcatheter arterial embolization (TAE) for the hepatic arterial injury related to percutaneous transhepatic portal intervention (PTPI).Materials and MethodsFifty-four patients, 32 males and 22 females with a median age of 68 years (range 43–82 years), underwent PTPI. The procedures consisted of 33 percutaneous transhepatic portal vein embolizations, 19 percutaneous transhepatic variceal embolizations, and 2 percutaneous transhepatic portal venous stent placements. Two patients with gastric varices underwent percutaneous transhepatic variceal embolization twice because of recurrence. Therefore, the total number of procedures was 56. Among them, hepatic arterial injury occurred in 6 PTPIs in 5 patients, and TAE was performed. We assessed technical success, complications related to TAE, and clinical outcome. Technical success was defined as the disappearance of findings due to hepatic arterial injury on digital subtraction angiography.ResultsAs hepatic arterial injuries, 4 extravasations and 2 arterioportal shunts developed. All TAEs were performed successfully. The technical success rate was 100 %. Complication of TAE occurred in 5 of 6 TAEs; 3 were focal liver infarction, not requiring further treatment, and 2 were biloma that required percutaneous drainage. Five TAEs in 4 patients were performed immediately after the PTPI, and these 4 patients were alive. However, one TAE was performed 10 h later, and the patient died due to multiple organ failure 2 months later although TAE was successful.ConclusionTAE is a useful treatment for hepatic arterial injury related to PTPI. However, it should be performed at an early stage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Skin dose mapping for fluoroscopically guided interventions

Purpose: To introduce a new skin dose mapping software system for interventional fluoroscopy dose assessment and to analyze the benefits and limitations of patient-phantom matching. Methods: In this study, a new software system was developed for visualizing patient skin dose during interventional fluoroscopy procedures. The system works by translating the reference point air kerma to the location of the patient's skin, which is represented by a computational model. In order to orient the model with the x-ray source, geometric parameters found within the radiation dose structured report (RDSR) are used along with a limited number of in-clinic measurements. The output of the system is a visual indication of skin dose mapped onto an anthropomorphic model at a resolution of 5 mm. In order to determine if patient-dependent and patient-sculpted models increase accuracy, peak skin dose was calculated for each of 26 patient-specific models and compared with doses calculated using an elliptical stylized model, a reference hybrid model, a matched patient-dependent model and one patient-sculpted model. Results were analyzed in terms of a percent difference using the doses calculated using the patient-specific model as the true standard. Results: Anthropometric matching, including the use of both patient-dependent and patient-sculpted phantoms, was shown most beneficial for left lateral and anterior-posterior projections. In these cases, the percent difference using a reference model was between 8 and 20%, using a patient-dependent model between 7 and 15%, and using a patient-sculpted model between 3 and 7%. Under the table tube configurations produced errors less than 5% in most situations due to the flattening affects of the table and pad, and the fact that table height is the main determination of source-to-skin distance for these configurations. In addition to these results, several skin dose maps were produced and a prototype display system was placed on the in-clinic monitor of an interventional fluoroscopy system. Conclusions: The skin dose mapping program developed in this work represents a new tool that, as the RDSR becomes available through automated export or real-time streaming, can provide the interventional physician information needed to modify behavior when clinically appropriate. The program is nonproprietary and transferable, and also functions independent to the software systems already installed on the control room workstation. The next step will be clinical implementation where the workflow will be optimized along with further analysis of real-time capabilities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Vascular Complications of Pancreatitis: Imaging and Intervention

The objective of this study was to highlight technical challenges and potential pitfalls of diagnostic imaging, intervention, and postintervention follow-up of vascular complications of pancreatitis. Diagnostic and interventional radiology imaging from patients with pancreatitis from 2002 to 2006 was reviewed. We conclude that biphasic CT is the diagnostic modality of choice. Catheter angiography may (still) be required to diagnose small pseudoaneurysms. Endovascular coiling is the treatment of choice for pseudoaneurysms. Close clinical follow-up is required, as patients may rebleed/develop aneurysms elsewhere.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Isolated Calyx Mistaken for a Cyst: Inappropriately Performed Catheter-Directed Sclerotherapy and Safe Removal of the Catheter After Selective Embolization

We present a case of isolated calyx that was mistaken for a large cyst. A 47-year-old woman was referred for sclerotherapy of a large cystic lesion on her left kidney. Computed tomography (CT) and ultrasound showed that the cystic lesion was a large cyst. We noticed that the cystic lesion was not a typical simple cyst, even after two sessions of catheter-mediated sclerotherapy. Isolated calyx was presumed by medical history review and was confirmed by aspirated fluid analysis and far delayed-phase CT after intravenous contrast injection. We performed meticulous selective arterial embolization for an isolated calyx and inserted a catheter that could be removed without complication.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local Control of Perivascular Malignant Liver Lesions Using Percutaneous Irreversible Electroporation: Initial Experiences

PurposeThis study was designed to assess efficacy and safety in the treatment of perivascular malignant liver lesions using percutaneous, computed tomography (CT)-guided irreversible electroporation (IRE).MethodsFourteen patients (mean age 58 ± 11 years) with 18 malignant liver lesions were consecutively enrolled in this study. IRE was performed in patients not eligible for surgery and lesions abutting large vessels or bile ducts. Follow-up exams were performed using multislice-CT (MS-CT) or MRI.ResultsMedium lesion diameter was 20 ± 5 mm. Ten of 14 (71 %) were successfully treated with no local recurrence to date (mean follow-up 388 ± 160 days). One case left initial tumor control unclear and additional RFA was performed 4 weeks after IRE. Complications occurred in 4 of 14 (29 %) cases. In one case, intervention was terminated and abdominal bleeding required laparotomy. In two cases, a postinterventional hematothorax required intervention. In another case, abdominal bleeding could be managed conservatively. No complications related to the bile ducts occurred.ConclusionsPercutaneous IRE seems to be effective in perivascular lesions but is associated with a higher complication rate compared with thermoablative techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of a Thermoprotective Gel for Hydrodissection During Percutaneous Microwave Ablation: In Vivo Results

PurposeTo evaluate whether thermoreversible poloxamer 407 15.4 % in water (P407) can protect non-target tissues adjacent to microwave (MW) ablation zones in a porcine model.Materials and MethodsMW ablation antennas were placed percutaneously into peripheral liver, spleen, or kidney (target tissues) under US and CT guidance in five swine such that the expected ablation zones would extend into adjacent diaphragm, body wall, or bowel (non-target tissues). For experimental ablations, P407 (a hydrogel that transitions from liquid at room temperature to semi-solid at body temperature) was injected into the potential space between target and non-target tissues, and the presence of a gel barrier was verified on CT. No barrier was used for controls. MW ablation was performed at 65 W for 5 min. Thermal damage to target and non-target tissues was evaluated at dissection.ResultsAntennas were placed 7 ± 3 mm from the organ surface for both control and gel-protected ablations (p = 0.95). The volume of gel deployed was 49 ± 27 mL, resulting in a barrier thickness of 0.8 ± 0.5 cm. Ablations extended into non-target tissues in 12/14 control ablations (mean surface area = 3.8 cm{sup 2}) but only 4/14 gel-protected ablations (mean surface area = 0.2 cm{sup 2}; p = 0.0005). The gel barrier remained stable at the injection site throughout power delivery.ConclusionWhen used as a hydrodissection material, P407 protected non-targeted tissues and was successfully maintained at the injection site for the duration of power application. Continued investigations to aid clinical translation appear warranted.

60 APPLIED LIFE SCIENCES↗