Search NASA⌕ Search

SEARCH · Search NASA

Results for “ANGULAR ACCELERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

TOWARD A METHOD FOR SCALING HUMAN BODY MODELS IN AN IMU-BASED WORKFLOW

BACKGROUND Scaled biomechanical models can more accurately inform crew health decisions when tailored to the wide range of astronaut sizes. One component to improve scaling of existing models to better represent each unique astronaut’s size is the individual length scaling of limbs. Traditionally, these lengths are determined by motion capture or manual measurement. A new method is herein proposed for length scaling which can be done by measuring linear and angular accelerations at a desired point during isolated motion around a point of rotation, then calculating the distance between the desired point and point of rotation. When an Inertial Measurement Unit (IMU) device is placed at the distal point of a limb, the isolated motion is about that limb’s proximal joint. For example, to measure forearm length, an IMU is placed at the wrist, the point of rotation is at the elbow, and the isolated motion is forearm flexion and extension. These calculated lengths are then used to scale models to each unique astronaut’s size, thereby improving the applicability of the model. This method of scaling limb segments can be used for any limb that has an easily defined proximal joint for the limb to rotate around including hands, arms, legs, feet. Utilizing IMUs for data collection also provides the synergistic ability to record data without a dedicated space in a room with many cameras, therefore reducing the data collection footprint, or record data where optical motion capture is not possible, such as inside a spacesuit. METHODS AND RESULTS To test this method, upper body data collection was performed with 5 Xsens DOT IMUs on a single subject. IMUs consist of an accelerometer, a gyroscope, and a magnetometer which collect linear acceleration, angular velocity, and magnetic fluctuations, respectively. Before any ground-based laboratory collection, the magnetic fluctuations are used to correct the heading of the IMU in space relative to the Earth’s magnetic field. The direct measurement of angular velocity is integrated to calculate angular acceleration. Then the linear acceleration ( a ) and angular acceleration (α) are solved using r = at/α to calculate the radius, which in this case is the distance between the IMU and the point of rotation (i.e., segment length). The IMU must be placed at the most distal point of the limb being measured (i.e., ankle if measuring lower leg length) and the test plan must consist of an isolated motion about that limb’s proximal joint (i.e., knee flexion and extension if measuring lower leg length). The distances (radii) calculated at every time interval were filtered (bandpass filter keeping 5th-90th percentile data) to eliminate outliers and spurious data that occur when the isolated motion was stopped or nearly stopped. The remaining distances were averaged, resulting in the calculated limb length. Scaling factors were then computed by dividing the calculated limb length by the unscaled model’s length. These scale factors are plugged into the Scale Tool in OpenSim [1,2] to apply the scaling to the OpenSim Full Body Rajagopal Model [3,4]. Manual measurements of limb lengths were taken before data collection started and used for comparing against the calculated lengths. The Anthropometric Survey of US Army Personnel (ANSUR II) [5] was also used as a third source of reference for limb length measurements. The following measurements were retrieved from the subject before data collection: 34.5 cm from L1 to C7 (thorax), 25.7 cm from C7 Joint Center (JC) to head vertex (neck and head), 36.3 cm from shoulder JC to elbow JC (humerus), 29.5 cm from elbow JC to wrist JC (forearm), and 16.2 cm from clavicle to acromion (clavicle). Of those five, forearm and humerus lengths were calculated using this proposed method to obtain preliminary results. The forearm length after filtering and averaging was calculated to be 37.6 cm. This is a 28% overestimation from the measured forearm length (29.5 cm). The humerus length after filtering and averaging was calculated to be 47.8 cm. This is a 31% difference from the measured subject length (36.3 cm). Sources of error include imperfect isolated motion (method currently expects that motion should be perfectly circular in a 2D plane, include no rotation of the IMU, and be relatively smooth; a more secure IMU attachment method will help), unrefined filter techniques (removed highest and lowest values with 20% high and low pass filters and no smoothing filters), arbitrary removal of stopped or near stopped data (kept data for only a short range before and after the angular velocity peaking), and a more representative method for removing gravitational acceleration is needed (current method is to zero all accelerations against a baseline taken just before the isolated motion which does not account for the gravitational acceleration changed due to IMU rotation during movement). Addressing these error sources will improve the accuracy of the limb length calculation. Next steps include creating a method for whole-body scaling estimation using individual limb scale factors. Continued pursuit of these techniques is expected to enable acquiring anthropometric information using only IMUs in real-time.

E. K. Marecki↗

Aircraft motion and passenger comfort data from scheduled commercial airline flights

Data concerning the ride quality of aircraft taken on board commercial airline flights was presented. Five types of data are included: (1) root mean square (RMS) values of linear acceleration, angular acceleration or angular velocities, along with passenger subjective evaluations, (2) power spectra for the motion in each of six degrees of freedom, (3) scattergrams showing the probability density of the rms accelerations in the vertical and transverse directions, (4) probability distributions of the motion, and (5) on board noise levels during takeoff, climb, cruise, and descent.

Gruesbeck, M. G.↗

Thresholds for detection of constant rotary acceleration during vibratory rotary acceleration

The effects of vibratory angular acceleration on detection thresholds for constant angular acceleration in a dynamic flight simulator are reported in three experiments. Detection thresholds were determined for 10 pilots and four nonpilots using a random, double-staircase procedure while the subjects sat erect in a device which rotated about an earth-vertical axis. Constant angular acceleration were presented for 0.5 and 1.0 s with concurrent, vibratory angular acceleration at 1 and 5 Hz, and thresholds with no vibratory angular acceleration were established. The thresholds were obtained while the subjects observed a visual reference in the enclosed cockpit in two experiments and in total darkness in a third. The results confirmed earlier experiments showing an inverse relationship between the duration of constant angular acceleration and detection threshold and showed that the detection thresholds in darkness were higher than with a visual reference present. Two analyses of variance revealed no significant differences in thresholds across the three vibration conditions. These results indicate that vibratory angular acceleration of fairly high levels can be present in a dynamic flight simulator without masking the pilot's ability to detect either maneuver or disturbance motions.

Clark, B.↗

Galactic Potential and Dark Matter Density from Angular Stellar Accelerations

Here, we present an approach to measure the Milky Way (MW) potential using the angular accelerations of stars in aggregate as measured by astrometric surveys like Gaia. Accelerations directly probe the gradient of the MW potential, as opposed to indirect methods using, e.g., stellar velocities. We show that end-of-mission Gaia stellar acceleration data may be used to measure the potential of the MW disk at approximately 3σ significance and, if recent measurements of the solar acceleration are included, the local dark matter density at ~2σ significance. Since the significance of detection scales steeply as t 5/2 for observing time t, future surveys that include angular accelerations in the astrometric solutions may be combined with Gaia to precisely measure the local dark matter density and shape of the density profile.

79 ASTRONOMY AND ASTROPHYSICS↗

Superconducting six-axis accelerometer

A new superconducting accelerometer, capable of measuring both linear and angular accelerations, is under development at the University of Maryland. A single superconducting proof mass is magnetically levitated against gravity or any other proof force. Its relative positions and orientations with respect to the platform are monitored by six superconducting inductance bridges sharing a single amplifier, called the Superconducting Quantum Interference Device (SQUID). The six degrees of freedom, the three linear acceleration components and the three angular acceleration components, of the platform are measured simultaneously. In order to improve the linearity and the dynamic range of the instrument, the demodulated outputs of the SQUID are fed back to appropriate levitation coils so that the proof mass remains at the null position for all six inductance bridges. The expected intrinsic noise of the instrument is 4 x 10(exp -12)m s(exp -2) Hz(exp -1/2) for linear acceleration and 3 x 10(exp -11) rad s(exp -2) Hz(exp -1/2) for angular acceleration in 1-g environment. In 0-g, the linear acceleration sensitivity of the superconducting accelerometer could be improved by two orders of magnitude. The design and the operating principle of a laboratory prototype of the new instrument is discussed.

Paik, H. J.↗

Subjective detection of vertical acceleration: A velocity dependent response?

Difficulty in the subjective tracking of the whole body vertical accelerative movement parallel to the long axis of the body is discussed which identified specifically the direction of imposed acceleration to be the difficulty rather than low sensitivity to vertical acceleration. The product of angular acceleration and time to detect proves to be constant over a wide range of suprathreshold step changes of angular acceleration. It is concluded that threshold conditions are determined by the velocity attained rather than the acceleration amplitude for the semicircular canals.

Jones, G. M.↗

Sensation of rotation about a vertical axis with a fixed visual field in different illuminations and in the dark

The effects of the oculogyro illusion of the relative motion of a spot fixed with respect to the subject during subject rotation and of a fixed striped peripheral visual field under different levels of illumination on perceptions of rotation about a vertical axis are investigated. Subjects were seated in a rotatable flight trainer cockpit with visual fields consisting of darkness, a dim peripheral field, and a bright peripheral field, all fixed with respect to the subject, and subject perceptual thresholds, frequency responses and sensations of displacement and velocity were measured during trainer rotation at constant and varying angular accelerations. The perception of angular acceleration is found to exhibit a significantly lower threshold and a reduced latency time in the illuminated visual fields which was independent of the level of illumination. Subjective frequency responses showed a higher gain in the illuminated presentations, while subjective displacements during triangular velocity stimuli exhibited no difference for the different visual cues. Finally, magnitude estimations of the after-rotation associated with deceleration from a constant velocity showed a greater rising speed, larger velocity and longer duration under illumination. Results show that, for low accelerations, the visual input enhances sensitivity to self-motion, an effect explained by the oculogyral illusion.

Huang, J.↗

Non-linear characteristics of the endolymph-cupula nystagmus system

The way a human can detect angular acceleration forces by means of the semicircular canals in the ears is discussed. The anatomy of the canals and the characteristics of the canal fluids are described. The physical implications of variation in cupula stiffness with angular acceleration are examined by analyzing cross-coupled angular acceleration and modeling mathematically the cupula-endolymph system. The system transfer function is obtained and the nonlinear characteristics of the endolymph-cupula-nystagmus system are discussed.

Mccormack, Percival D.↗

Hormonal responses of metoclopramide-treated subjects experiencing nausea or emesis during parabolic flight

The concentrations of adrenocorticotropic hormone (ACTH), vasopressin (AVP), epinephrine (EPI), and norepinephrine (NE) in 22 subjects administered 10 to 20 mg of metoclopramide prior to parabolic flight are measured. The effect of metoclopramide on motion sickness is examined. It is observed that metoclopramide is ineffective in the modulation of motion sickness due to stressful linear and angular acceleration and orbital flight, and it does not affect serum hormones prior to parabolic flight. It is detected that the serum level of AVP declines following emesis induced by parabolic flight and stressful angular acceleration; the serum levels of ACTH and EPI are elevated by parabolic flight and stressful angular acceleration; and serum NE is significantly elevated immediately following emesis. The possible roles of these hormones in the etiology of space motion sickness are discussed.

Kohl, Randall L.↗

Congruent and spurious motion in the learning and performance of a compensatory tracking task.

Examination of the importance of congruent and spurious yaw motion in compensatory tracking by eight airline pilots. The pilots, seated erect in the Ames man-carrying rotation device(MCRD), tracked with k/s+1 and k/s(s+1) vehicle dynamics in fixed- and moving-base simulation. Following the learning phase of the experiment, five levels of spurious angular acceleration were superimposed on the motion of the MCRD. Learning of the tracking task was found to be a function of both vehicle dynamics and mode of simulation. The presence of congruent motion information reduced learningtime in k/s(s+1) vehicle dynamics and resulted in lower tracking error in both vehicle dynamics. The spurious angular accelerations resulted in an increase in pilot tracking error; however, the relationship between the magnitude of the acceleration and its effect was highly complex. The data suggest that the minimal disturbance level for spurious angular accelerations during tracking is below 0.4 degec.

Guercio, J. G.↗

A study of unsymmetrical-loading conditions

The force variation along the wing span under combined normal and angular accelerations is considered. Non dimensional curves of section load, shear, and moment are given for: (1) the air load that produces a normal acceleration; (2) the accompanying wing weight and normal inertia loads; (3) aileron and gust air loads that produce angular acceleration; (4) the angular inertia load of the wing. The required aerodynamic load distributions have been obtained by use of wing theory, and the wing inertia distributions are based on an analysis of wing-weight data. Several examples are included to illustrate the effect of wing taper and aileron span on the total shears and moments at any section along the span.

Pearson, Henry A↗

Dynamic Model Investigation of the Rough-Water Landing Characteristics of a Spacecraft

The investigation was made to study the rough-water landing characteristics of a Gemini type of spacecraft. The investigations were made with a 1/6-scale dynamic model in a simulated sea state 4 rough water. Parachute letdown landings were simulated with the model at various yaw angles and horizontal velocities. The vertical velocity and landing attitude remained constant. The range of maximum lateral and longitudinal acceleration was from about 3-1/2g to 16g while that for the maximum normal acceleration was from lg to 15g. The range of maximum angular acceleration was from about 0 to 190 radians per second(exp 2). The smoothest behavior and the lowest angular acceleration occurred at the 90 degree yaw angle. The normal acceleration was near minimum at this condition.

[Division] Imp. Str↗

Determination of solar flare accelerated ion angular distributions from SMM gamma ray and neutron measurements and determination of the He-3/H ratio in the solar photosphere from SMM gamma ray measurements

Comparisons of Solar Maximum Mission (SMM) observations of gamma-ray line and neutron emission with theoretical calculation of their expected production by flare accelerated ion interactions in the solar atmosphere have led to significant advances in the understanding of solar flare particle acceleration and interaction, as well as the flare process itself. These comparisons have enabled the determination of, not only the total number and energy spectrum of accelerated ions trapped at the sun, but also the ion angular distribution as they interact in the solar atmosphere. The Monte Carlo program was modified to include in the calculations of ion trajectories the effects of both mirroring in converging magnetic fields and of pitch angle scattering. Comparing the results of these calculations with the SMM observations, not only the angular distribution of the interacting ions can be determined, but also the initial angular distribution of the ions at acceleration. The reliable determination of the solar photospheric He-3 abundance is of great importance for understanding nucleosynthesis in the early universe and its implications for cosmology, as well as for the study of the evolution of the sun. It is also essential for the determinations of the spectrum and total number of flare accelerated ions from the SMM/GRS gamma-ray line measurements. Systematic Monte Carlo calculations of the time dependence were made as a function of the He-3 abundance and other variables. A new series of calculations were compared for the time-dependent flux of 2.223 MeV neutron capture line emission and the ratio of the time-integrated flux in the 2.223 MeV line to that in the 4.1 to 6.4 MeV nuclear deexcitation band.

Lingenfelter, Richard E.↗

A Method for Integrating Thrust-Vectoring and Actuated Forebody Strakes with Conventional Aerodynamic Controls on a High-Performance Fighter Airplane

A method, called pseudo controls, of integrating several airplane controls to achieve cooperative operation is presented. The method eliminates conflicting control motions, minimizes the number of feedback control gains, and reduces the complication of feedback gain schedules. The method is applied to the lateral/directional controls of a modified high-performance airplane. The airplane has a conventional set of aerodynamic controls, an experimental set of thrust-vectoring controls, and an experimental set of actuated forebody strakes. The experimental controls give the airplane additional control power for enhanced stability and maneuvering capabilities while flying over an expanded envelope, especially at high angles of attack. The flight controls are scheduled to generate independent body-axis control moments. These control moments are coordinated to produce stability-axis angular accelerations. Inertial coupling moments are compensated. Thrust-vectoring controls are engaged according to their effectiveness relative to that of the aerodynamic controls. Vane-relief logic removes steady and slowly varying commands from the thrust-vectoring controls to alleviate heating of the thrust turning devices. The actuated forebody strakes are engaged at high angles of attack. This report presents the forward-loop elements of a flight control system that positions the flight controls according to the desired stability-axis accelerations. This report does not include the generation of the required angular acceleration commands by means of pilot controls or the feedback of sensed airplane motions.

Lallman, Frederick J.↗

Correlation between X-ray flux and rotational acceleration in Vela X-1

The results of a search for correlations between X-ray flux and angular acceleration for the accreting binary pulsar Vela X-1 are presented. Results are based on data obtained with the Hakucho satellite during the interval 1982 to 1984. In undertaking this correlation analysis, it was necessary to modify the usual statistical method to deal with conditions imposed by generally unavoidable satellite observing constraints, most notably a mismatch in sampling between the two variables. The results are suggestive of a correlation between flux and the absolute value of the angular acceleration, at a significance level of 96 percent. The implications of the methods and results for future observations and analysis are discussed.

Deeter, J. E.↗

Sliding control of pointing and tracking with operator spline estimation

It is shown how a variable structure control technique could be implemented to achieve precise pointing and good tracking of a deformable structure subject to fast slewing maneuvers. The correction torque that has to be applied to the structure is based on estimates of upper bounds on the model errors. For a rapid rotation of the deformable structure, the elastic response can be modeled by oscillators driven by angular acceleration, and where stiffness and damping coefficients are also angular velocity and acceleration dependent. By transforming this slew-driven elastic dynamics into bilinear form (be regarding the vector made up of the angular velocity, squared angular velocity and angular acceleration components, which appear in the coefficients as the input to the deformation dynamics), an operator spline can be constructed, that gives a low order estimate of the induced disturbance. Moreover, a worst case error bound between the estimated deformation and the unknown exact deformation is also generated, which can be used where required in the sliding control correction.

Dwyer, Thomas A. W., III↗

Vestibular functions and sleep in space experiments

Physical indices of sleep were continuously monitored in an owl monkey living in a chamber continuously rotating at a constant angular velocity. The electrophysiological data obtained from chronically implanted electrodes was analyzed to determine the chronic effects of vestibular stimulation on sleep and wakefulness cycles. The interaction of linear and angular acceleration on the vestibulo-ocular reflex was investigated in three rhesus monkeys at various angular accelerations.

Perachio, A. A.↗

Autorotating wings - An experimental investigation.

The autorotation of a flat plate about its spanwise axis was experimentally studied. Most of the work was done with a wing mounted in a 5 x 7 ft low-speed wind tunnel. The measurements consisted of the unsteady lift, drag, angular acceleration and the wing rotation rate. The flow pattern was very different from that over a static wing. The maximum and average lift, drag and angular acceleration were measured for Reynolds numbers from 25,000 to 250,000. The effect of applying driving and retarding torques to the wing was studied. A variety of wing configurations were tested, together with freely falling wings. For Reynolds numbers above 4000 the average lift and drag coefficients were comparable to those observed in the fixed axis tests, and it appeared that the flow pattern was similar.

Smith, E. H.↗