Search NASA⌕ Search

SEARCH · Search NASA

Results for “ANNULAR SPACE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Annular-Tube Reinforcer

Cylindrical tool inserts support sleeves into annular space between coaxial tubes to provide local reinforcement. Tool particularly useful when space between outer ends of coaxial tubes is narrow, requiring thin sleeve.

Pessin, R.↗

Signal and power roll ring testing update

The development of the roll ring as a long-life, low-torque alternative to the slip ring is discussed. A roll ring consists of one or more circular flexures captured by their own spring force in the annular space between two concentric conductors or contact rings. The advantages of roll rings over other types of electrical transfer devices are: extremely low drag torque, high transfer efficiencies in high-power configurations, extremely low wear debris generation, long life, and low weight for high-power applications.

Smith, Dennis W.↗

Thermally isolated deployable shield for spacecraft

A thermally isolated deployable shield for spacecraft is provided utilizing a plurality of lattice panels stowable generally against the craft and deployable to some fixed distance from the craft. The lattice panels are formed from replaceable shield panels affixed to lattice structures. The lattice panels generally encircle the craft providing 360 degree coverage therearound. Actuation means are provided from translating the shield radially outward from the craft and thermally isolating the shield from the craft. The lattice panels are relatively flexible, allowing the shield to deploy to variable diameters while retaining uniform curvature thereof. Restraining means are provided for holding the shield relatively tight in its stowed configuration. Close-out assemblies provide light sealing and protection of the annular spaces between the deployed shield and the crafts end structure.

Redmon, John W., Jr.↗

Annular denuders for use in global climate and stratospheric measurements of acidic gases and particles

Measurements of acidic and basic gases that coexist with fine particle (less than 2.5 micron) may be useful for determining the impact of these species on global climate changes and determining species that influence stratospheric ozone levels. Annular denuders are well suited for this purpose. A new concentric annular denuder system, consisting of a three channel denuder, a Teflon coated cyclone preseparator, and a multistage filter pack was developed, evaluated, and shown to provide reliable atmospheric measurements of SO2, HNO2, HNO3, NH3, SO4(=), NH4(+), NO3(-), and H(+). For example, the precision of the annular denuder for the ambient measurements of HNO3 and nitrates at concentrations between 0.1 to 3 microgram/cu m was + or - 12 and 16 pct., respectively. The 120 x 25 mm three channel denuder is encased in a stainless steel sheath and has annular spaces that are 1 mm wide. This design was shown to have nearly identical capacity for removal of SO2 as conventional 210 x 25 mm single channel denuder configurations. The cyclone preseparator was designed and tested to have a D sub 50 cutoff diameter of 2.5 micron and minimal retention of HNO3.

Stevens, Robert K.↗

Piston-Skirt Lubrication System For Compressor

Piston-skirt lubrication system provides steady supply of oil to piston rings of gas compressor. No need for oil-filled crankcase or external oil pump. Instead, part of each piston acts as its own oil pump circulating oil from reservoir. Annular space at bottom of piston and cylinder constitutes working volume of small oil pump. Depending on application, reservoir open to atmosphere, or sealed and pressurized in bellows to prevent contact between oil and atmosphere. Filter removes particles worn away from piston rings and cylinder wall during normal operation.

Schroeder, Edgar C.↗

Overall Thermal Performance of Flexible Piping Under Simulated Bending Conditions

Flexible, vacuum-insulated transfer lines for low-temperature applications have higher thermal losses than comparable rigid lines. Typical flexible piping construction uses corrugated tubes, inner and outer, with a multilayer insulation (MLI) system in the annular space. Experiments on vacuum insulation systems in a flexible geometry were conducted at the Cryogenics Test Laboratory of NASA Kennedy Space Center. The effects of bending were simulated by causing the inner tube to be eccentric with the outer tube. The effects of spacers were simulated in a controlled way by inserting spacer tubes for the length of the cylindrical test articles. Two material systems, standard MLI and a layered composite insulation (LCI), were tested under the full range of vacuum levels using a liquid nitrogen boiloff calorimeter to determine the apparent thermal conductivity (k-value). The results indicate that the flexible piping under simulated bending conditions significantly degrades the thermal performance of the insulation system. These data are compared to standard MLI for both straight and flexible piping configurations. The definition of an overall k-value for actual field installations (k(sub oafi)) is described for use in design and analysis of cryogenic piping systems.

Fesmire, James E.↗

Fan blade protection system

In one type of aircraft propulsion system, propeller blades are mounted on a ring which surrounds a turbine. An annular space exists between the turbine and the ring. If a propeller blade should break free, the unbalanced centrifugal load tends to deform the ring. The invention reduces the deformation, as by locating spacers between the turbine and the ring.

Hermans, Thomas C.↗

Microsphere insulation systems

A new insulation system is provided that contains microspheres. This insulation system can be used to provide insulated panels and clamshells, and to insulate annular spaces around objects used to transfer, store, or transport cryogens and other temperature-sensitive materials. This insulation system provides better performance with reduced maintenance than current insulation systems.

Allen, Mark S.↗

Dual-Band Feed for a Microwave Reflector Antenna

A waveguide feed has been designed to provide specified illumination patterns for a dual-reflector antenna in two wavelength bands: 8 to 9 GHz and 30 to 40 GHz. The feed (see figure) has a coaxial configuration: A wider circular tube surrounds a narrower circular tube that serves as a waveguide for the signals in the 30-to-40-GHz band. The annular space between the narrower and the wider tube serves as a coaxial waveguide for the signals in the 8-to-9-GHz band. The nominal design frequencies of the outer and inner waveguides are 8.45 and 32 GHz, respectively. Each of the two waveguides is terminated in a component that is sized and shaped to help focus the radiation in its respective frequency band into the specified illumination pattern. For the outer waveguide, the beam-shaping termination is a corrugated horn; for the inner waveguide, the beam-shaping termination is a dielectric rod insert.

Hoppe, Daniel↗

Two Heat-Transfer Improvements for Gas Liquefiers

Two improvements in heat-transfer design have been investigated with a view toward increasing the efficiency of refrigerators used to liquefy gases. The improvements could contribute to the development of relatively inexpensive, portable oxygen liquefiers for medical use. A description of the heat-transfer problem in a pulse-tube refrigerator is prerequisite to a meaningful description of the first improvement. In a pulse-tube refrigerator in particular, one of in-line configuration heat must be rejected from two locations: an aftercooler (where most of the heat is rejected) and a warm heat exchanger (where a small fraction of the total input power must be rejected as heat). Rejection of heat from the warm heat exchanger can be problematic because this heat exchanger is usually inside a vacuum vessel. When an acoustic-inertance tube is used to provide a phase shift needed in the pulse-tube cooling cycle, another problem arises: Inasmuch as the acoustic power in the acoustic-inertance tube is dissipated over the entire length of the tube, the gas in the tube must be warmer than the warm heat exchanger in order to reject heat at the warm heat exchanger. This is disadvantageous because the increase in viscosity with temperature causes an undesired increase in dissipation of acoustic energy and an undesired decrease in the achievable phase shift. Consequently, the overall performance of the pulse-tube refrigerator decreases with increasing temperature in the acoustic-inertance tube. In the first improvement, the acoustic-inertance tube is made to serve as the warm heat exchanger and to operate in an approximately isothermal condition at a lower temperature, thereby increasing the achievable phase shift and the overall performance of the refrigerator. This is accomplished by placing the acoustic-inertance tube inside another tube and pumping a cooling fluid (e.g., water) in the annular space between the tubes. Another benefit of this improvement is added flexibility of design to locate the warm heat-rejection components outside the vacuum vessel. The second improvement is the development of a compact radial-flow condenser characterized by a very high heat transfer coefficient and a small pressure drop.

Martin, Jerry L.↗

Bulk Moisture and Salinity Sensor

Measurement and feedback control of nutrient solutions in plant root zones is critical to the development of healthy plants in both terrestrial and reduced-gravity environments. In addition to the water content, the amount of fertilizer in the nutrient solution is important to plant health. This typically requires a separate set of sensors to accomplish. A combination bulk moisture and salinity sensor has been designed, built, and tested with different nutrient solutions in several substrates. The substrates include glass beads, a clay-like substrate, and a nutrient-enriched substrate with the presence of plant roots. By measuring two key parameters, the sensor is able to monitor both the volumetric water content and salinity of the nutrient solution in bulk media. Many commercially available moisture sensors are point sensors, making localized measurements over a small volume at the point of insertion. Consequently, they are more prone to suffer from interferences with air bubbles, contact area of media, and root growth. This makes it difficult to get an accurate representation of true moisture content and distribution in the bulk media. Additionally, a network of point sensors is required, increasing the cabling, data acquisition, and calibration requirements. measure the dielectric properties of a material in the annular space of the vessel. Because the pore water in the media often has high salinity, a method to measure the media moisture content and salinity simultaneously was devised. Characterization of the frequency response for capacitance and conductance across the electrodes was completed for 2-mm glass bead media, 1- to 2-mm Turface (a clay like media), and 1- to 2-mm fertilized Turface with the presence of root mass. These measurements were then used to find empirical relationships among capacitance (C), the dissipation factor (D), the volumetric water content, and the pore water salinity.

Nurge, Mark↗

Assessment of Gaseous Helium Cooling in a Superconducting Coil Test Rig

An experimental rig was designed and constructed at the NASA Glenn Research Center to measure the alternating current (AC) losses of round, multifilament, superconducting (SC), magnesium diboride (MgB2) wire in the temperature range from 20 to 30 K. The rig resembles a permanent magnet (PM) motor with the stator windings omitted. Experiment packs containing the superconductor samples will be placed in the annular space between the rotor and the stator back iron. The original plan was to measure the AC losses by calorimetry using nonboiling liquid hydrogen as the cooling fluid. The present plan is to use helium gas (GHe) under a few bar pressure instead. This report summarizes the calculations that indicate that reasonable results can be obtained, even though the mass density of the GHe will be only a fraction of that of liquid hydrogen. It is necessary to show that the heat transfer coefficient from SC wire to GHe can be high enough, that the temperature rise of the He between the experiment inlet and outlet can be small enough, and that sufficient He flow can be driven by a commercially available He fan. Both straight wire samples to validate loss models and coils to simulate motor stator coils can be tested in the rig. The lowest superconductor temperature that is feasible to reach in the rig is estimated. The temperature range available for samples will be wider with the gaseous He system than it would have been with liquid hydrogen.

supeconductors↗

Composite drill pipe and method for forming same

A lightweight and durable drill pipe string capable of short radius drilling formed using a composite pipe segment formed to include tapered wall thickness ends that are each defined by opposed frustoconical surfaces conformed for self-aligning receipt and intimate bonding contact within an annular space between corresponding surfaces of a coaxially nested set of metal end pieces and a set of nonconductive sleeves. The distal peripheries of the nested end pieces and sleeves are then welded to each other and the sandwiched and bonded portions are radially pinned. The composite segment may include imbedded conductive leads and the axial end portions of the end pieces are shaped to form a threaded joint with the next pipe assembly that includes contact rings in the opposed surfaces of the pipe joint for contact together.

47 OTHER INSTRUMENTATION↗

Novel Use of Water Soluble "Aquapour" As A Temporary Spacer During Coil Winding For The NSTX-U Centerstack

A major facility upgrade to the National Spherical Torus eXperiment (NSTX-U) is currently underway at Princeton Plasma Physics Laboratory (PPPL). A key component of NSTX-U is the fabrication of a new, higher field centerstack (CS). In order to simultaneously provide robust joints between the inner and outer legs of the Toroidal Field Coils (TF) and minimize radial build, the NSTX-U CS design requires that the Ohmic Heating solenoid (OH) be wound directly on the inner TF bundle. To protect the OH against thermal expansion stress during scenarios where the inner TF bundle is hot but the OH is relatively cool, the completed CS will have a 0.100 inch annular gap between the outer diameter of the TF bundle and the inner diameter of the OH solenoid. "Aquapour", a proprietary material produced by the Advanced Ceramics Manufacturing Company will be used during manufacture to produce this gap. After the TF bundle is vacuum pressure impregnated and cured, a cylindrical "clam shell" mold will be assembled around it, and a slurry of powdered Aquapour and water will be pumped into the annular space between the mold and TF bundle. Subsequent baking will turn the Aquapour solid, and a protective layer of wet lay-up fiberglass and resin will be added. The OH solenoid will be wound directly on this wet lay-up shell. After vacuum pressure impregnation of the OH, the water soluble Aquapour will be washed away, leaving the required radial clearance between the TF and OH. This paper will describe prototyping and testing of this process, and plans for use on the actual CS fabrication.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Anode shroud for off-gas capture and removal from electrolytic oxide reduction system

An electrolytic oxide reduction system according to a non-limiting embodiment of the present invention may include a plurality of anode assemblies and an anode shroud for each of the anode assemblies. The anode shroud may be used to dilute, cool, and/or remove off-gas from the electrolytic oxide reduction system. The anode shroud may include a body portion having a tapered upper section that includes an apex. The body portion may have an inner wall that defines an off-gas collection cavity. A chimney structure may extend from the apex of the upper section and be connected to the off-gas collection cavity of the body portion. The chimney structure may include an inner tube within an outer tube. Accordingly, a sweep gas/cooling gas may be supplied down the annular space between the inner and outer tubes, while the off-gas may be removed through an exit path defined by the inner tube.

42 ENGINEERING↗

Experimental Study of Counterflow Cooling Using a Test Loop to Simulate the Thermal Characteristics of a HTS Cable System

The counterflow cooling configuration is a compact, efficient, and relatively low cost thermal management approach for long-length HTS cable systems. In the counter-flow cooling configuration the coolant flow, typically liquid nitrogen, is initially supplied through the center of the cable turning around at the far end of the cable and returning through the annular space between the cable and the inner cryostat wall, using a single cryostat. The temperature distributions along the cable and the nitrogen flow streams are extremely difficult to measure in an operating HTS cable because of the issues associated with installing thermometers on high voltage components. A 5-meter long test loop has been built that simulates a counter-flow cooled, HTS cable using a heated metal tube to simulate the cable. The test loop contains calibrated thermometers to measure the temperature distribution along the tube and the return liquid nitrogen stream. Measured temperature distributions in the return flow stream and along the tube wall for varying flow rates and heating conditions to simulate a HTS cable are presented and discussed.

Demko, Jonathan A↗

Thermal Insulation for a High Temperature Molten Salt Storage Tank in a CSP Plant: Preprint

A ternary molten chloride has been suggested as a high temperature (550-720 °C) sensible heat storage medium for a two-tank system. An effective thermal insulation is proposed to provide an opportunity for the fabrication of both the hot and cold storage tanks from lower cost metals, e.g. A240-347H, by maintaining the tank wall below 500 °C. To achieve this, the hot storage tank mainly comprises of inner shell (11.4 cm of a refractory brick as liner (KX-99 ®), 30 cm of insulation brick) and outer metal shell, where 5 cm of frozen layer of PCM800 (NaCl), and 5 cm of ceramic wool fill the annular space between the shells. Another layer of ceramic wool was introduced at the outer side of the metal shell to keep the temperature lower than 60 °C. ANSYS Fluent was used for the numerical study of the cool down behavior of the system during idle period when tank is quarter-filled. The heat transfer modes were considered as radiation and natural convection heat transfer from the hot molten salt at 720 °C, conduction through the solid layers and convection heat transfer from the outer shell to the environment at 15 °C. The results showed that the proposed insulation system including a frozen layer of PCM800 maintains the temperature at the metal wall lower than 500 °C, and lower than 60 °C at the outer side of the tank. Apart from the insulation property of the frozen layer of PCM800, it absorbs any leak of hot molten salt, acting as a barrier between salt and the metal shell. The thermal performance analysis provide an insight into the benefits of the multilayer insulation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

System and method thermopile energy harvesting for subsurface well bore sensors

A system and method for powering a borehole sensor with thermal energy is disclosed. The system includes a tubular pipe inserted into a subsurface borehole. A borehole casing is coaxially disposed with the tubular pipe. An annular space between the casing and the tubular pipe has a power source placed in the borehole to power a sensor in response to a temperature gradient between a surface of the casing and a surface of the tubular pipe. The method includes attaching thermopiles on the borehole casing or tubing; placing the thermopile in the annulus between the casing and the tubing; inducing a thermal gradient across the thermopile; generating an electrical energy in response to the temperature gradient; powering the sensor from the generated energy; and monitoring vertical expansion of a CO2 plume.

Bryan, Charles R.↗