At least 55 records · Page 3

Investigation of a subsonic-arc-attachment thruster using segmented anodes

To investigate high frequency arc instabilities observed in subsonic-arc-attachment thrusters, a 3 kW, segmented-anode arcjet was designed and tested using hydrogen as the propellant. The thruster nozzle geometry was scaled from a 30 kW design previously tested in the 1960's. By observing the current to each segment and the arc voltage, it was determined that the 75-200 kHz instabilities were results of axial movements of the arc anode attachment point. The arc attachment point was fully contained in the subsonic portion of the nozzle for nearly all flow rates. The effects of isolating selected segments were investigated. In some cases, forcing the arc downstream caused the restrike to cease. Finally, decreasing the background pressure from 18 Pa to 0.05 Pa affected the pressure distribution in the nozzle, including the pressure in the subsonic arc chamber.

Berns, Darren H.↗

Investigation of a subsonic-arc-attachment thruster using segmented anodes

To investigate high frequency arc instabilities observed in subsonic-arc-attachment thrusters, a 3 kW, segmented-anode arc jet was designed and tested using hydrogen as the propellant. The thruster nozzle geometry was scaled from a 30 kW design previously tested in the 1960's. By observing the current to each segment and the arc voltage, it was determined that the 75-200 kHz instabilities were results of axial movements of the arc anode attachment point. The arc attachment point was fully contained in the subsonic portion of the nozzle for nearly all flow rates. The effects of isolating selected segments were investigated. In some cases, forcing the arc downstream caused the restrike to cease. Finally, decreasing the background pressure from 18 to 0.05 Pa affected the pressure distribution in the nozzle including the pressure in the subsonic arc chamber.

Berns, Darren H.↗

Ground Tests of High-Voltage Solar Arrays Immersed in a Low Density Plasma

Five different types of solar arrays have been tested in large vacuum chamber. Arc inception voltages, arc rates, and current collections are measured for samples with different coverglass materials and thickness, interconnect designs, and cell sizes. It is shown that the array with wrapthrough interconnects have the highest arc threshold and the lowest current collection. Coverglass design with overhang results in decrease of current collection and increase of arc threshold. Doubling coverglass thickness does not improve measured array parameters. Both arc inception voltage and current collection increase significantly with increasing a sample temperature to 80 C. Sustained discharges are initiated between adjacent cells with potential differences of 40 V for the sample with 300 pm coverglass thickness and 60 V for the sample with 150 urn coverglass thickness.

Vayner, Boris↗

Heat-barrier coatings for combustion chambers

Arc-plasma-sprayed layered coating of graded Inconel and zirconia protects film-coolant ring below injector plate of rocket engine combustion chamber. Interfacial temperature is designed for minimum buildup of stress and to avoid melting of the metal phase in the graded layers.

Carpenter, H. W.↗

Magnetic Measurements of Arc Instabilities in Segmented Arc Heater Column

The Aerodynamic Heating Facility (AHF) at NASA Ames Research Center (ARC) generates high enthalpy, supersonic flow environments for ground testing of NASAheat shield materials. This arc jet heater operates by passing a DC arc (<3200A,<2500V) through a gas column (~10cm diameter, 2m length) and ejecting the heatedgas through a supersonic nozzle into a test chamber. The arc plasma is a partially ionized air mixture at low temperature (< 2eV) but needs to be stable for long test times (up to 30min) at high power (< 20MW). Currently, the operational envelope of the facility is limited by arc instabilities including the kink instability. Consequently, it is of interest to characterize these instabilities to better understand facility limits and inform methods to extend stable operational ranges. Due to the high enthalpy and long timescales (i.e., minutes) diagnostics must be non-invasive. This work will cover the development of two sets of magnetic sensors: differential B-dot sensors and tri-axial magnetic hall sensors and will describe initial measurements of arc motion usingthese sensors.

Kink instability↗

SU-E-P-35: Real-Time Patient Transit Dose Verification of Volumetric Modulated Arc Radiotherapy by a 2D Ionization Chamber Array

Purpose: To explore the real-time dose verification method in volumetric modulated arc radiotherapy (VMAT) with a 2D array ion chamber array. Methods: The 2D ion chamber array was fixed on the panel of electronic portal imaging device (EPID). Source-detector distance (SDD)was 140cm. 8mm RW3 solid water was added to the detector panel to achieve maximum readings.The patient plans for esophageal, prostate and liver cancers were selected to deliver on the cylindrical Cheese phantom 5 times in order to validate the reproducibility of doses. Real-time patient transit dose measurements were performed at each fraction. Dose distributions wereevaluated using gamma index criteria of 3mm DTA and 3% dose difference referred to the firsttime Result. Results: The gamma index pass rate in the Cheese phantom were about 98%; The gamma index pass rate for esophageal, liver and prostate cancer patient were about 92%,94%, and 92%, respectively; Gamma pass rate for all single fraction were more than 90%. Conclusion: The 2D array is capable of monitoring the real time transit doses during VMAT delivery. It is helpful to improve the treatment accuracy.

60 APPLIED LIFE SCIENCES↗

Magnetic Measurements of Arc Instabilities in Segmented Arc Heater Column

The Aerodynamic Heating Facility (AHF) at NASA Ames Research Center (ARC) generates high enthalpy, supersonic flow environments for ground testing of NASAheat shield materials. This arc jet heater operates by passing a DC arc (<3200 A,<2500 V) through a gas column (~6 cm diameter, 2 m length) and ejecting the heated gas through a supersonic nozzle into a test chamber. The arc plasma is a partially ionized air mixture at low temperature (< 2 eV) but needs to be stable for long test times (up to 30 min) at high power (< 20 MW). Currently, the operational envelope of the facility is limited by arc instabilities including the kink instability. Consequently, it is of interest to characterize these instabilities to better understand facility limits and inform methods to extend stable operational ranges. Due to the high enthalpy and long timescales (i.e., minutes) diagnostics must be non-invasive. This work will cover the development of two sets of magnetic sensors: differential B-dot sensors and tri-axial magnetic hall sensors and will describe initial measurements of arc motion using these sensors.

Kink instability↗

SU-E-T-337: Dosimetric Study of TMI Using Helical Tomotherapy

Purpose: The purpose of this study is to evaluate the dosimtry of TMI using Helical Tomotherapy (HT). Methods: Whole body CT data sets of 4 patients (median age : range:12–37 years) with 5mm slice thickness were used for planning in HT (TPS version 4.2.3). The contouring of the target and organ at risks (OAR) were delineated ( Oncentra Master Plan v 4.1). Two plans were generated using 5cm and 2.5 cm field widths.The modulation factor and pitch was 3 and 0.3 respectively. Dose to PTV, OARs and the dose homogeneity were evaluated. The doses obtained were compared with the existimg literature. Dose delivery verification was carried out by point dose and 2D array measurements with ion chamber and Arc check dosimetry (Sun NuclearTM) system repectively. The prescribed dose was 14.4 Gy in 8 fractions. Results: The mean PTV volume was 7341.28cc (sd=2353) The dose homogeneity index of PTV was 12.03(sd=2.98) for 2.5cm-FW and 14.61 (sd=1.33) for 5cm-FW.The conformation number for 2.5 and 5 cm plans are 0.6328(sd=0.09) and 0.5915 (sd=0.0376) respectively. The mean dose(Gy) to the OARs were as follows for 2.5cm-FW : eyes, lens, lungs, kidneys, heart, liver,thyroid and testes for are 4.12,1.9,6.61,4.04,4.85,6.06,7.17 and 1.27. The mean dose(Gy) to the OARs were as follows for 5cm-FW :eyes, lens, lungs, kidneys, heart, liver,thyroid and testes for are 4.45,3.14,6.79,4.02,5.01,6.01,10.8 and 1.33. The mean variation of the point dose as compared to the expected dose was within 2% and the gamma analysis was at 91%. Conclusion: It was concluded that 5cm field width plans produces optimal dose volume parameters with deliverable treatment time. From this initial dissymmetric study, it was concluded that the treatment planning and the dose delivery verification was feasible considering the complexity of the TMI.

60 APPLIED LIFE SCIENCES↗

Effects of insulator ablation on the operation of a quasi-steady MPD arc

Multimegawatt operation of quasi-steady MPD arcjets can involve serious ablation of the insulator surfaces within the arc discharge chamber. Various degrees of insulator ablation manifest themselves by significantly perturbing the voltage-current characteristics and the exhaust velocity profiles. Voltage-current characteristics for two different insulator materials, Plexiglas and boron nitride, are interpreted in terms of an empirical Ohm's law. Use of the refractory insulator material eliminates the ablation-dominated nature of the terminal voltage, but the exhaust stream is still disturbed by insulator material. An Alfven critical velocity model can be applied to this influence of insulator ablation on exhaust velocity. Appropriate changes in the propellant injection geometry eliminate this influence and result in arcjet operation which is independent of insulator material. A particular combination of propellant injection geometries reduces the terminal voltage for a given current and mass flow while maintaining insulator-independent operation, thus implying an improvement in the overall efficiency of the device.

Boyle, M. J.↗

Modular Pulsed Plasma Electric Propulsion System for Cubesats

Current capabilities of CubeSats must be improved in order to perform more ambitious missions. Electric propulsion systems will play a key role due to their large specific impulse. Compared to other propulsion alternatives, their simplicity allows an easier miniaturization and manufacturing of autonomous modules into the nano and pico-satellite platform. Pulsed Plasma Thrusters (PPTs) appear as one of the most promising technologies for the near term. The utilization of solid and non-volatile propellants, their low power requirements and their proven reliability in the large scale make them great candidates for rapid implementation. The main challenges are the integration and miniaturization of all the electronic circuitry into a printed circuit board (PCB) that can satisfy the strict requirements that CubeSats present. NASA Ames and the George Washington University have demonstrated functionality and control of three discrete Micro-Cathode Arc Thrusters (CAT) using a bench top configuration that was compatible with the ARC PhoneSat Bus. This demonstration was successfully conducted in a vaccum chamber at the ARC Environmental Test Laboratory. A new effort will integrate a low power Plasma Processing Unit and two plasma thrusters onto a single printed circuit board that will utilize less than 13 U of Bus volume. The target design will be optimized for the accommodation into the PhoneSatEDISON Demonstration of SmallSatellite Networks (EDSN) bus as it uses the same software interface application, which was demonstrated in the previous task. This paper describes the design, integration and architecture of the proposed propulsion subsystem for a planned Technology Demonstration Mission. In addition, a general review of the Pulsed Plasma technology available for CubeSats is presented in order to assess the necessary challenges to overcome further development.

PCB↗

Initial Characterization of the 30 kW Miniature Arc Jet (mARC II) at NASA Ames Research Center

The second-generation Miniature Arc jet Research Chamber (mARC II) at NASA Ames is undergoing integrated systems testing. Once fully operational, this facility will be added to the range of available test facilities operated by the NASA Ames Thermophysics Facilities Branch, with primary focus on applications such as new arc jet flow diagnostics and new arc column diagnostics. Initial characterization of the mARC II is reported here, specifically, measured arc current, arc voltage, column and chamber pressures, mass flow rates, and initial emission measurements carried out at a range of conditions.

arc jet↗

Utilizing ARC EMCS Seedling Cassettes as Highly Versatile Miniature Growth Chambers for Model Organism Experiments

The aim of our ground testing was to demonstrate the capability of safely putting specific model organisms into dehydrated stasis, and to later rehydrate and successfully grow them inside flight proven ARC EMCS seedling cassettes. The ARC EMCS seedling cassettes were originally developed to support seedling growth during space flight. The seeds are attached to a solid substrate, launched dry, and then rehydrated in a small volume of media on orbit to initiate the experiment. We hypothesized that the same seedling cassettes should be capable of acting as culture chambers for a wide range of organisms with minimal or no modification. The ability to safely preserve live organisms in a dehydrated state allows for on orbit experiments to be conducted at the best time for crew operations and more importantly provides a tightly controlled physiologically relevant growth experiment with specific environmental parameters. Thus, we performed a series of ground tests that involved growing the organisms, preparing them for dehydration on gridded Polyether Sulfone (PES) membranes, dry storage at ambient temperatures for varying periods of time, followed by rehydration. Inside the culture cassettes, the PES membranes were mounted above blotters containing dehydrated growth media. These were mounted on stainless steel bases and sealed with plastic covers that have permeable membrane covered ports for gas exchange. The results showed we were able to demonstrate acceptable normal growth of C.elegans (nematodes), E.coli (bacteria), S.cerevisiae (yeast), Polytrichum (moss) spores and protonemata, C.thalictroides (fern), D.discoideum (amoeba), and H.dujardini (tardigrades). All organisms showed acceptable growth and rehydration in both petri dishes and culture cassettes initially, and after various time lengths of dehydration. At the end of on orbit ISS European Modular Cultivation System experiments the cassettes could be frozen at ultra-low temperatures, refrigerated, or chemically preserved before being returned to Earth for analyses. Our results suggest that with protocol modifications and future verification testing we can utilize the versatile EMCS to conduct tightly controlled experiments inside our culture cassettes for a wide variety of organisms. These physiological experiments would be designed to answer questions at the molecular level about the specific stress responses of space flight.

Model Organism Experiments↗

Recycling of volatiles at subduction zones: Noble gas evidence from the Tabar-Lihir-Tanga-Feni arc of papua New Guinea

Convergent margin processes play an important but poorly understood role in the distribution of terrestrial volatile species. For example, subduction processes filter volatiles from the subducting package, thereby restricting their return to the mantle. In addition, once extracted from the downgoing slab, volatiles become an essential component in the petrogenesis of island arc magmas. The noble gases, with their systematic variation in physical properties and diversity of radiogenic isotopes, should carry a uniquely valuable record of these processes. However, thus far studies of noble gases in arc volcanics have achieved only limited success in this regard. Subduction-related lavas and geothermal fluids carry (3)He/(4)He ratios equal to or slightly lower than those found in the depleted upper mantle source of mid-ocean ridge basalts. Apparently slab-derived helium (which should have (3)He/(4)He much less than MORB) is extensively diluted by MORB-like helium from the mantle wedge, making it difficult to use helium as a tracer of convergent margin processes. Interpretation of the heavier noble gases (Ne-Ar-Kr-Xe) in arc lavas has also proven difficult, because the lavas carry low noble gas concentrations and hence are subject to pervasive atmospheric contamination. The low noble gas concentrations may be a consequence of degassing in the high level magma chambers characteristic of arc stratovolcanos. We have recently initiated a project to better constrain the behavior of volatiles in subduction zones through geochemical studies of the tectonically unusual volcanoes of the Tabar-Lihir-Tanga-Feni (TLTF) arc in the Bismarck Archipelago, Papua New Guinea.

Farley, Kenneth↗

Use of arc-jet hypersonic blunted wedge flows for evaluating performance of Orbiter TPS

Arc-jet tests at NASA/JSC have been conducted recently to evaluate the performance of the Orbiter Thermal Protection System (TPS) on three critical areas of the side and top of the Orbiter fuselage: (1) cargo bay door, (2) crew access door, and (3) LRSI/FRSI joint regions. Test articles corresponding to these three areas on the Orbiter were mounted in an arc-jet test chamber in a blunted-wedge holder and exposed to hypersonic flow at various angles of attack. The effects of flow direction, heating load, and overtemperature were investigated. In addition, the reuse capability of the TPS materials was evaluated, along with the protection of the pressure seals within the test articles. Thermal match model predictions correlated well with primary structure thermocouple data. Heating rate and pressure predictions based on a nonequilibrium flow field computer program showed good agreement with arc-jet test data and existing hypersonic flow theories.

Rochelle, W. C.↗

High-Fidelity Simulations of HyMETS Arc-Jet Flows for PICA-N Modeling

Arc-jet testing is a fundamental tool in the screening of thermal protection systems under atmospheric entry conditions. In this work, high-fidelity computational fluid dynamics simulations coupled with machine learning methods for the Hypersonic Materials Environmental Test System arc-jet facility have been carried out. This effort improves the MEDLI-2 data reconstruction fidelity by understanding the impact of the NuSil coating over the PICA thermocouple plugs. Thermochemical non-equilibrium models are employed to simulate the flows inside the arc-jet nozzle and chamber and machine learning techniques are used to calibrate the arc-jet inflow conditions. The material response is simulated with the recession and in-depth numerical results compared to experimental measurements.

STMD↗