Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ablatives Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Safety and Efficacy of Radiation Therapy in Advanced Melanoma Patients Treated With Ipilimumab

Purpose: Ipilimumab and radiation therapy (RT) are standard treatments for advanced melanoma; preclinical models suggest the potential for synergy. However, limited clinical information exists regarding safety and optimal timing of the combination. Methods and Materials: We reviewed the records of consecutive patients with unresectable stage 3 or 4 melanoma treated with ipilimumab. Patients were categorized as having received RT or not. Differences were estimated between these 2 cohorts. Results: We identified 88 patients treated with ipilimumab. At baseline, the ipilimumab-plus-RT group (n=44) had more unfavorable characteristics. Despite this, overall survival, progression-free survival, and both immune-related and non–immune-related toxicity were not statistically different (P=.67). Patients who received ipilimumab before RT had an increased duration of irradiated tumor response compared with patients receiving ipilimumab after RT (74.7% vs 44.8% at 12 months; P=.01, log-rank test). In addition, patients receiving ablative RT had non–statistically significantly improved median overall survival (19.6 vs 10.2 months), as well as 6-month (95.1% vs 72.7%) and 12-month (79.7% vs 48.5%) survival rates, compared with those treated with conventionally fractionated RT. Conclusions: We found that both ablative and conventionally fractionated RT can be safely administered with ipilimumab without a clinically apparent increase in toxicity. Patients who received ipilimumab before RT had an increased duration of irradiated tumor response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-density carbon capsule experiments on the national ignition facility

Indirect-drive implosions with a high-density carbon (HDC) capsule were conducted on the National Ignition Facility (NIF) to test HDC properties as an ablator material for inertial confinement fusion. In this study, a series of five experiments were completed with 76-μm-thick HDC capsules using a four-shock laser pulse optimized for HDC. The pulse delivered a total energy of 1.3 MJ with a peak power of 360 TW. The experiment demonstrated good laser to target coupling (~90 %) and excellent nuclear performance. Lastly, a deuterium and tritium gas-filled HDC capsule implosion produced a neutron yield of 1.6×10 15 ± 3×10 13 , a yield over simulated in one dimension of 70%.

42 ENGINEERING↗

Effects of cyclic plasma heating on surface damage of micro-porous tungsten

The operating temperature window of solid tungsten (W) is dictated by its Ductile to Brittle Transition Temperature (DBTT) and re-crystallization temperature; roughly between 300-1300 °C. The brittleness of W at lower temperatures is exasperated when it undergoes recrystallization. We investigate here the thermal shock resistance of micro-porous W as a meta-material fabricated in a 3D open-cell network structure. We present experimental results for the effects of cyclic high-enthalpy arc-jet plasma on surface damage in three testing categories. Observed damage includes surface ablation of asperities, melting and solidification of W-fuzz on samples that have been exposed to a prior helium plasma, and micro-cracks at ligament triple junctions. Scanning electron microscope (SEM) observations show more micro-cracking on 54% and 23% foams compared to the 43% ones. In all tested samples, thermal expansion/contraction displacements were accommodated by ligament rotation and a network of micro-cracks. Furthermore, no large through-thickness crack were observed.

36 MATERIALS SCIENCE↗

Removal of Metal Oxides from Reactor Metals/Alloys by Laser Ablation

Storage of low and intermediate level radioactive waste in a deep geological repository (L and ILW DGR): - Large volumes of metallic waste = increased production of hydrogen gas. - Large fraction of the metallic wastes are out-of-core reactor components. - Carbon steel feeder pipes. - Radioactive contamination is concentrated within the surface oxides. - Removal of surface contaminants would lead to volume reduction of metallic waste that is stored in L and ILW DGR. - Current decontamination techniques generate large volumes of secondary waste. Objectives: Oxide removal from carbon steel using a ytterbium fiber laser (1064 nm) with a particular focus on identifying the key laser parameters that affect the removal efficiency. Advantages of laser ablation: Generate low volumes of waste, Flexibility of deployment, Remote operation. Grow an oxide film on carbon steel with the incorporation of cobalt. Optimize laser cleaning technology for the removal of surface oxides. Incorporate an oxide collection system for the ablated particles. Conclusions: Objective 1 - Simulated inactive oxides on carbon steel, using Co{sup 2+} as a surrogate for Co radionuclide. Objective 2 - Optimized laser parameters (200 MW/cm{sup 2}, 3 scans, 15 μm overlap); Complete removal of cobalt from surface and bulk metal with optimized cleaning settings. Objective 3 - Glass fiber media H14 HEPA filters had highest collection yield; High oxide collection yields (∼100%). Future Work: Further testing of the liquid trap will verify the efficacy of the HEPA filter and determine the amount of ablated oxides that pass through. Testing of the laser ablation system needs to be done on other reactor materials along with the incorporation of different transition metal cations. Improvements to the oxide collection system are required to improve collection yields.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Laser ablation of high-loading Li-ion battery electrodes improves accessible capacity and cycle life for Behind-the-Meter Storage

Adoption of Behind-the-Meter Storage (BTMS) requires design of batteries that enable high safety, long cycle life, and low cost at the system level. Pairing Li 4 Ti 5 O 12 (LTO) with LiMn 2 O 4 (LMO) achieves targets related to safety and cycle life, but these materials' low energy densities contribute to higher cost at the system scale. Increasing electrode loading is a simple approach to improve energy density, but comes with a trade-off in electrode utilization due to long, tortuous Li + diffusion pathways. Here, laser ablation is used to microstructure (pattern) high-loading electrodes to enhance electrode performance through improved Li + diffusion pathways. Four cell types, comprising combinations of standard or patterned anode and cathode, were prepared to evaluate the effects of laser ablation at each electrode. A rate test shows that patterning electrodes enhances active material utilization at ≳1C rates. Patterning the cathode yields the most benefit, as cells with a patterned cathode demonstrate a ~20% higher accessible capacity than those without at 1.4C. Additionally, 1C capacity retention of cells with patterned cathode (91% through 3000 cycles) is significantly improved over cells with only the anode patterned (64%) and non-patterned electrodes (50%). Characterization of post-mortem cells before and after refreshing their electrolyte suggests that 1C capacity retention is improved by mitigation of electrode "dry-out". We hypothesize that the microstructure acts as a reservoir of additional electrolyte, or a path for gas to escape, so that active material remains wetted throughout long-term cycling, and/or the microstructure may reduce localized, gas-forming overpotentials in the high-loading electrode.

25 ENERGY STORAGE↗

Experimental method for laser-driven flyer plates for 1-D shocks

One-dimensional shocks can be generated by impacting flyer plates accelerated to terminal velocities by a confined laser-ablated plasma. Over the past few years, we have developed this capability with our facility-size laser, TRIDENT, capable of {>=}500 Joules at multi-microsecond pulse lengths to accelerate 1-D flyer plates, 8-mm diameter by 0.1-2 mm thick. Plates have been accelerated to terminal velocities of 100 to {>=}500 m/s, with full recovery of the flyer and target for post mortem metallography. By properly tailoring the laser temporal and spatial profile, the expanding confined plasma accelerates the plate away from the transparent sapphire substrate, and decouples the laser parameters from shock pressure profile resulting from the plate impact on a target. Since the flyer plate is in free flight on impact with the target, minimal collateral damage occurs to either. The experimental method to launch these plates to terminal velocity, ancillary diagnostics, and representative experimental data is presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Refining Methods to Determine the Isotopic Composition of Uranium Particles by Laser Ablation MC-ICP-MS

We report on efforts to mitigate the generation of isotopic anomalies during the ablation of micrometer-sized uranium oxide particles and analysis by MC-ICP-MS. The results of testing on particles of U200 indicate that laser fluence and frequency can affect isotopic data produced by laser ablation, but no settings were tested that could eradicate the signal spiking effect and generation of anomalous isotopic data for 234U/238U and 236U/238U. These anomalies are more frequent in samples with higher 235U enrichments, which is expected given their higher abundances of 234U and 236U. Of the standards tested here, only U005-A was anomaly-free. Efforts to compare the laser traces for particles with normal and anomalous isotopic compositions showed subtle differences in the behavior of the 234U/238U and 236U/238U ratios. However, it would be challenging to identify anomalous data points from a population of unknowns using this distinction, i.e., this is unlikely to be diagnostic. Thus, using current analytical hardware, we cannot eradicate the signal spiking phenomenon and cannot unambiguously identify isotopic anomalies from laser ablation traces. Ultimately, laser ablation ICP-MS would either require dramatic improvement to the ablation process and generation of more homogenous aerosols and/or improvements to detector electronics to identify and correct for the spiking phenomenon. Even if the reliability of the technique could be improved, a broader question to address is whether current data quality is of a high enough standard for laser ablation MC-ICP-MS to be used as a complementary technique to LG-SIMS for Safeguards.

organic↗

Compact And Robust Laser Impulse Measurement Device, With Ultrashort Pulse Laser Ablation Results

An impulse measurement device and analysis package was conceived, designed, constructed, tested, and demonstrated to be capable of: measuring nanoNewton-seconds to milliNewton-seconds of impulse due to laser-ablation; being transported as carry-on baggage; set-up and tear-down times of less than an hour; target exchange times of less than two minutes (targets can be ablated at multiple positions for thousands of shots); measurements in air and in vacuum; error of just a few percent; repeatability over a wide range of potential systematic error sources; and time between measurements, including ring-down and analysis, of less than 30 seconds. The instrument consists of a cantilever (i.e. leaf spring), whose time-dependent displacement/oscillation is measured and analyzed to determine the impulse imparted by a laser pulse to a target. These shapes are readily/commercially available, and any target material can be used, provided it can be fashioned in the form of a cantilever, or as a coating/film/tape, suitable for mounting on a cantilever of known geometry. The instrument was calibrated both statically and dynamically, and measurements were performed on brass, steel, and Aluminum, using laser pulses of {approx}7 ns, {approx}500 ps, and {approx}500 fs. The results agree well with those published in the literature, with surface effects, atmosphere, and pre-/post-pulses demonstrating interesting effects and indicating areas for further study. These parameters should be carefully controlled and held constant during a series of measurements. The impulse imparted by ablation due to laser filaments in air was also explored.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Developing Methodology to Determine Pu Isotopic Composition by Laser Ablation MC-ICP-MS

This project will develop methodology to analyze the Pu isotope ratio in mixed U-Pu particles by laser ablation MC-ICP-MS. This will involve: 1) testing and validation of the Pu analytical method using mixed U-Pu solutions and Pu doped glasses, 2) isotopic analysis of mixed U-Pu particles by laser ablation MC-ICP-MS, and 3) continued development of the R-based data reduction program. Details regarding the analytical method development and results of QC testing will be output as a deliverable to the IAEA, along with an updated version of the LARA data reduction software.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

OECD MCCI Project: Category 4 Integral Test to Validate Severe Accident Codes: Core-Concrete Interaction Test Six (CCI-6) Test Plan (Rev. 6)

Ex-vessel debris coolability is an important light water reactor (LWR) safety issue. For existing plants, resolution of this issue will confirm the technical basis for severe accident management guidelines (SAMGs). For new reactors, understanding this issue will help confirm the effectiveness of the design and implementation of new accident mitigation features and severe accident management design alternatives (SAMDAs). The first OECD-MCCI program conducted reactor material experiments focused on achieving the following technical objectives: i) provide confirmatory evidence and data for various cooling mechanisms through separate effect tests for severe accident model development, and ii) provide long-term 2-D core-concrete interaction data for code assessment and improvement. The PRG recommends that the OA design a 70 cm x 70 cm test, with two concrete side walls, using CEA siliceous concrete, 6 wt% concrete composition, early top flooding initiated when ablation is established and melt temperature has stabilized. The melt depth shall be 30 cm. The test will be designed for two specific phases. The first phase will provide for 30 cm for radial ablation and 25 cm for vertical ablation. In the event that the melt is not cooled down by top flooding during the first phase, a second and separate test phase will begin involving bottom flooding. This second phase will be initiated when axial ablation depth reaches 25 cm. The design should be mindful of the curing time of the concrete. The instrumentation should be refined to provide data on the water injection characteristics and melt temperature near the lateral walls. In response to this recommendation, the objective of this document is to provide a summary test plan for this sixth Core-Concrete Interaction (CCI-6) experiment for PRG review. Test specifications that were developed as part of the design work are provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Formation of Organic Compounds Through Meteoritic Atmospheric Shock

This document is a Final Technical Report for DoE award DE-SC0023375 “Formation of Organic Compounds Through Meteoritic Atmospheric Shock”. The document includes a summary of topics studied, specific tasks completed, challenges, and results from the project. The main goal of this project was to investigate the production of organic molecules and/or complex inorganic precursor molecules in a plasma environment reminiscent of the environment surrounding meteoroids during atmospheric entries. The specific hypothesis tested in this project was that meteoroid ablation during the entry and the chemical reactions in the meteoroid plasma tail could have produced significant amounts of organics or precursor inorganics in the Early Earth’s atmosphere. Investigation of these processes is essential in understanding the origins of life on Earth and the search for life beyond our planet. This project was focused on a set of experiments conducted at the Utilizing the DIII-D tokamak in San Diego, CA. The experiments aimed to study the interaction of carbonaceous and silica materials (typically found in meteoroids) with mixtures of hot plasma gases (mimicking atmospheric entry conditions. The material samples and gas mixtures were selected to investigate the synthesis of the organic compound urea – a key ingredient in the origin of life – or one of its precursor, the complex inorganic compound ammonia.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chemical clocks: using otolith geochemistry to enhance estimation of age and growth of white hake (Urophycis tenuis)

The white hake (Urophycis tenuis) is a groundfish distributed throughout the Gulf of Maine. Catch advice is based on stock assessments done with age-based population dynamics models; however, otolith aging is challenging because of unclear growth increments. To address this concern, we compared the consistency of aging with counts of visual annuli to that of aging with cycles of elemental concentrations measured by using laser ablation inductively coupled plasma mass spectrometry. We tested the hypothesis that oscillations in both environmental conditions and internal physiology through time influence uptake of elements during otolith mineralization. Concentrations of manganese, in comparison with those of the other investigated trace elements (magnesium, strontium, and barium), had the most promising correlation with visual growth increments (~100% age agreement, ±1 year), offering an additional tool to enhance increment identification. In our examination of 550 otoliths collected during 2007–2021, we found that white hake lived a maximum of 10.3 years and exhibited sexual dimorphism in maximum length and age. By using generated von Bertalanffy growth functions, L(t)=110(1–e–0.113(t+0.45)) for males and L(t)=140(1–e–0.113(t–0.30)) for females (where L(t) is length at time t), size and age at maturity were calculated for males (37.4 cm in total length (TL), 3.3 years) and females (47.4 cm TL, 4.2 years). These results demonstrate that otolith geochemistry can be used to improve the accuracy and precision of the estimation of fish age and maturity, even for challenging species.

59 BASIC BIOLOGICAL SCIENCES↗

Histopomorphic Evaluation of Radiofrequency Mediated Débridement Chondroplasty

The use of radiofrequency devices has become widespread for surgical ablation procedures. When ablation devices have been deployed in treatment settings requiring tissue preservation like débridement chondroplasty, adoption has been limited due to the collateral damage caused by these devices in healthy tissue surrounding the treatment site. Ex vivo radiofrequency mediated débridement chondroplasty was performed on osteochondral specimens demonstrating surface fibrillation obtained from patients undergoing knee total joint replacement. Three radiofrequency systems designed to perform débridement chondroplasty were tested each demonstrating different energy delivery methods: monopolar ablation, bipolar ablation, and non-ablation energy. Treatment outcomes were compared with control specimens as to clinical endpoint and histopomorphic characteristics. Fibrillated cartilage was removed in all specimens; however, the residual tissue remaining at the treatment site displayed significantly different characteristics attributable to radiofrequency energy delivery method. Systems that delivered ablation-based energies caused tissue necrosis and collateral damage at the treatment site including corruption of cartilage Superficial and Transitional Zones; whereas, the non-ablation system created a smooth articular surface with Superficial Zone maintenance and without chondrocyte death or tissue necrosis. The mechanism of radiofrequency energy deposition upon tissues is particularly important in treatment settings requiring tissue preservation. Ablation-based device systems can cause a worsened state of articular cartilage from that of pre-treatment. Non-ablation energy can be successful in modifying/preconditioning tissue during débridement chondroplasty without causing collateral damage. Utilizing a non-ablation radiofrequency system provides the ability to perform successful débridement chondroplasty without causing additional articular cartilage tissue damage and may allow for other cartilage intervention success.

59 BASIC BIOLOGICAL SCIENCES↗

LASER ABLATION-INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION SPECTROSCOPY STUDY AT THE 222-S LABORATORY USING HOT-CELL GLOVE BOX PROTOTYPE SYSTEM

This report describes the installation, testing and acceptance of the Waste Treatment and Immobilization Plant procured laser ablation-inductively coupled plasma-atomic emission spectroscopy (LA-ICP-AES) system for remotely analyzing high-level waste samples in a hot cell environment. The 2005-003; ATS MP 1027, Management Plan for Waste Treatment Plant Project Work Performed by Analytical Technical Services. The APD group at the 222-S laboratory demonstrated acceptable turnaround time (TAT) and provide sufficient data to assess sensitivity, accuracy, and precision of the LA-ICP-AES method.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ablation of phosphoinositide-3-kinase class II alpha suppresses hepatoma cell proliferation

Cancer such as hepatocellular carcinoma (HCC) is characterized by complex perturbations in multiple signaling pathways, including the phosphoinositide-3-kinase (PI3K/AKT) pathways. Herein we investigated the role of PI3K catalytic isoforms, particularly class II isoforms in HCC proliferation. Among the siRNAs tested against the eight known catalytic PI3K isoforms, specific ablation of class II PI3K alpha (PIK3C2{alpha}) was the most effective in impairing cell growth and this was accompanied by concomitant decrease in PIK3C2{alpha} mRNA and protein levels. Colony formation ability of cells deficient for PIK3C2{alpha} was markedly reduced and growth arrest was associated with increased caspase 3 levels. A small but significant difference in gene dosage and expression levels was detected between tumor and non-tumor tissues in a cohort of 19 HCC patients. Taken together, these data suggest for the first time that in addition to class I PI3Ks in cancer, class II PIK3C2{alpha} can modulate HCC cell growth.

60 APPLIED LIFE SCIENCES↗

Laser concrete ablation scaling effects.

Surface scabbling of concrete by laser processing has been demonstrated in the literature for large-area problems ({approx}50 mm wide x 10 deep) using physically large, high-power consumption, multi-kW CW laser systems. With large spot diameters ({approx}50 mm) and low power densities ({approx} 300 W/cm{sup 2}), large volume thermal stresses are induced which promote concrete cracking. This process is highly power-density and heat-input (J/m) dependent. Too high power densities cause melting and generate potentially toxic fumes by vaporizing the cement matrix material. New applications require concrete removal with more portable, lower power equipment, and low particulate and fume generation. Recent results investigating the process for small-area ({approx} 2 x 2 mm) removal are examined and discussed. Tests performed were limited to < 700W output power. Ablation via thermal cracking was observed at larger spot sizes but as the spot size approached 10 mm (with constant power density) ablation ceased and melting predominated. Scaling effects involving temperature gradients through the ITZ (Interfacial Transition Zone), the probability of including an ITZ in the beam path at decreasing spot sizes, and the gradient effects on bulk properties between rock and sand zones will be presented and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

LASER ABLATION-INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION SPECTROSCOPY STUDY AT THE 222-S LABORATORY USING HOT-CELL GLOVE BOX PROTOTYPE SYSTEM

This report describes the installation, testing, and acceptance of the Waste Treatment and Immobilization Plant (WTP) procured laser ablation-inductively coupled plasma-atomic emission spectroscopy (LA-ICP-AES) system for remotely analyzing high-level waste (HLW) samples in a hot cell environment. The work was completed by the Analytical Process Development (APD) group in accordance with Task Order 2005-003; ATS MP 1027, Management Plan for Waste Treatment Plant Project Work Performed by Analytical Technical Services. The APD group at the 222-S Laboratory demonstrated acceptable turnaround time (TAT) and provide sufficient data to assess sensitivity, accuracy, and precision of the LA-ICP-AES method.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Interpretive modelling of boron transport in the boundary plasma of WEST experiments with the impurity powder dropper

Abstract Boron (B) powder injection is a potential alternative to glow discharge boronization as a wall conditioning method for tokamaks. This technique is currently being studied in WEST experiments, during which B powder is injected by an Impurity Powder Dropper developed by PPPL. In order to interpret and analyse experimental trends, and to help develop future experiments, a modelling workflow using a boundary plasma simulation (SOLEDGE-EIRENE) and powder ablation simulation (Dust Injection Simulator) was developed and tested. The effect of adding a B neutral source to simulated deuterium + oxygen (D + O) plasmas was compared to experimental data from the WEST C5 campaign, where B powder was injected in a dedicated experiment. While the impact of B injection on radiated power P rad measurements at the upper divertor was similar, there were significant differences in measurements of P rad , outer strike point electron temperature T e OSP and O-II line intensity at the lower divertor between experiment and simulation. This discrepancy suggests that those parameters were affected by phenomena not present in the simulations, with the most likely candidates being reduced D recycling and a reduced O sourcing from the divertor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗