Search NASA⌕ Search

SEARCH · Search NASA

Results for “Absolute Cavity Radiometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Calibration procedure of Hukseflux SR25 to Establish the Diffuse Reference for the Outdoor Broadband Radiometer Calibration

Accurate pyranometer calibrations, traceable to internationally recognized standards, are critical for solar irradiance measurements. One calibration method is the component summation method, where the pyranometers are calibrated outdoors under clear sky conditions, and the reference global solar irradiance is calculated as the sum of two reference components, the diffuse horizontal and subtended beam solar irradiances. The beam component is measured with pyrheliometers traceable to the World Radiometric Reference, while there is no internationally recognized reference for the diffuse component. In the absence of such a reference, we present a method to consistently calibrate pyranometers for measuring the diffuse component. The method is based on using a modified shade/unshade method and a pyranometer with less than 0.5 W/m2 thermal offset. The calibration result shows that the responsivity of Hukseflux SR25 pyranometer equals 10.98 uV/(W/m2) with +/-0.86 percent uncertainty.

14 SOLAR ENERGY↗

Absolute Cavity Pyrgeometer (ACP)

ACP Measures atmospheric longwave irradiance with traceability to the International System of Units (SI). To date the Interim world reference World Infrared Standard Group (WISG) is traceable to blackbody (not sky/atmosphere), and InfraRed Integrating Sphere (IRIS) Developed by the World Radiation Center (PMOD) is traceable to blackbody irradiance. The ACP is self calibrated radiometer using heat substitution like Absolute Cavity Radiometer (ACR) that is self calibrated radiometer using electrical substitution to measure solar irradiance. ACP is a contribution to develop the world reference with traceability to SI, using the outdoor irradiance as the source, instead of blackbody.

ACP↗

Improved Primary Reference Cell Calibrations for Higher Accuracy Photovoltaic Cell and Module Performance Measurements

The adoption of photovoltaic (PV) modules for clean electricity relies on accurate measurements of their performance, which are essential for estimating their energy production potential. Herein, the calibration chain of PV cells and modules, with particular emphasis on primary reference cell calibrations, is discussed. Also, herein, the direct sunlight method the group has developed for these calibrations is presented and critical improvements and upgrades that lead to calibration uncertainty as low as 0.45% are discussed. The ultimate motivation behind this work is to provide low‐uncertainty performance measurements of PV modules, and lowering the calibration uncertainty of primary reference cells is a key first step toward achieving this goal. As the use of solar electricity continues to grow, the demand for primary reference cell calibrations inevitably increases beyond what the small handful of primary calibration laboratories can provide today. Therefore, this work can serve as a useful guide for implementing primary PV reference cell calibrations using the outdoor method, as well as outlining the critical elements required to make these calibrations highly accurate.

Osterwald, Carl R.↗

Traceability of Surface Longwave Irradiance Measurements to SI Using the IRIS Radiometers

The traceability of the World Infrared Standard Group of Pyrgeometers (WISG) was established through the comparison to several independently calibrated radiometers (Infrared Integrating Sphere Radiometer (IRIS), Absolute Cavity Pyrgeometer (ACP), Atmospheric Emittance Radiance Interferometer (AERI)). The traceability of the longwave irradiance measurements to SI was validated by a comparison of two independently characterized blackbody cavities.

ACR↗

Results of First Outdoor Comparison Between Absolute Cavity Pyrgeometer (ACP) and Infrared Integrating Sphere (IRIS) Radiometer at PMOD (Presentation)

The ACP and IRIS are developed to establish a world reference for calibrating pyrgeometers with traceability to SI units. The two radiometers are unwindowed with negligible spectral dependence, and traceable to SI units through the temperature scale (ITS-90). The first outdoor comparison between the two designs was held from January 28 to February 8, 2013 at the Physikalisch-Metorologisches Observatorium Davos (PMOD). The difference between the irradiance measured by ACP and that of IRIS was within 1 W/m2. A difference of 5 W/m2 was observed between the irradiance measured by ACP&IRIS and that of the interim World Infrared Standard Group (WISG).

14 SOLAR ENERGY↗

Traceability of Surface Longwave Irradiance Measurements to SI Using the IRIS Radiometers: Preprint

The World Radiation Center at PMOD/WRC is operated on behalf of the WMO. The Infrared Radiometry Section of the WRC (WRC-IRS) provides traceability of downwelling atmospheric longwave radiation measured with pyrgeometers by comparison to the World Infrared Standard Group (WISG) [1]. As has been discussed previously [2], the current implementation of the WISG measures lower longwave irradiances than the two candidate reference radiometers IRIS (Infrared Integrating Sphere Radiometer) and the ACP (Absolute Cavity Pyrgeometer). To validate the findings reported in [2], additional measurements since that publication in 2014 have been performed and are discussed in this paper. Specifically, Measurements during cloud-free nights at PMOD/WRC between the WISG and IRIS radiometers, A field campaign at the Atmospheric Radiation Monitoring Site (ARM) at Southern Great Plains, Oklahoma with IRIS, ACP, AERI (Atmospheric Emittance Radiance Interferometer) and WISG traceable pyrgeometers, Laboratory comparison between the reference blackbody of PMOD/WRC with the hemispherical blackbody developed by PTB.

ACR↗

Instrumentation for measurements of solar irradiance and atmospheric optical properties

The Active Cavity Radiometer (ACR), an accurate absolute pyrheliometer, has been developed for measurements of total solar irradiance. It has been used to discover a -2.2% error in the International Pyrheliometric Scale and to make measurements in balloon flight experiments yielding a solar constant value of 136.6 (+ or - 0.7) mW/sq cm. New ACRs are being developed to monitor the total output of solar optical radiation in balloon, satellite and space shuttle experiments with long-term absolute uncertainty of + or - 0.1% or less. In a separate program, instrumentation for the measurement of the scattering and extinction of solar radiation by the atmosphere is being constructed to provide data for modeling atmospheric aerosol content. The aerosol models will facilitate computation of radiative transfer effects yielding quantitative net fluxes useful in evaluating the climatological impact of aerosols.

Willson, R. C.↗

Latest Development to Establish the World Reference with Traceability to SI Units for Measuring the Atmospheric Shortwave and Longwave Irradiance

To date, Interim world reference traceable to blackbody (not sky/atmosphere) is used as a reference noted as a World Infrared Standard Group (WISG). Plan forward: to develop a reference standards traceable to SI InfraRed Integrating Sphere (IRIS) Developed by the World Radiation Center (PMOD) is traceable to blackbody irradiance. Absolute Cavity Pyrgeometer (ACP) developed by NLR is a self-calibrating radiometer using heat substitution to measure the atmospheric longwave irradiance. ACP is a contribution to develop the world reference with traceability to SI, using the outdoor irradiance as the source, instead of blackbody.

14 SOLAR ENERGY↗

Absolute calibration of an ultraviolet spectrometer using a stabilized laser and a cryogenic cavity radiometer

We carry out the calibration of an ultraviolet spectrometer by using a cryogenic electrical-substitution radiometer and intensity-stabilized laser sources. A comparison of the error budgets for the laser-based calibration described here and for a calibration using a type-FEL tungsten spectral-irradiance standard indicates that this technique could provide an improvement of a factor of about three in the uncertainty of the spectrometer calibration, resulting in an absolute accuracy (standard deviation of three) of about 1 percent at 257 nm. The technique described here might significantly improve the accuracy of calibrations on NASA ozone-monitoring and solar ultraviolet-monitoring spectrophotometers when used to complement present procedures that employ lamps and the SURF II synchrotron ultraviolet radiation facility at the National Institute of Standards and Technology.

Jauniskis, L.↗

Results of Absolute Cavity Pyrgeometer and Infrared Integrating Sphere Comparisons

Accurate and traceable atmospheric longwave irradiance measurements are required for understanding radiative impacts on the Earth's energy budget. The standard to which pyrgeometers are traceable is the interim World Infrared Standard Group (WISG), maintained in the Physikalisch-Meteorologisches Observatorium Davos (PMOD). The WISG consists of four pyrgeometers that were calibrated using Rolf Philipona's Absolute Sky-scanning Radiometer [1]. The Atmospheric Radiation Measurement (ARM) facility has recently adopted the WISG to maintain the traceability of the calibrations of all Eppley precision infrared radiometer (PIR) pyrgeometers. Subsequently, Julian Grobner [2] developed the infrared interferometer spectrometer and radiometer (IRIS) radiometer, and Ibrahim Reda [3] developed the absolute cavity pyrgeometer (ACP). The ACP and IRIS were developed to establish a world reference for calibrating pyrgeometers with traceability to the International System of Units (SI). The two radiometers are unwindowed with negligible spectral dependence, and they are traceable to SI units through the temperature scale (ITS-90). The two instruments were compared directly to the WISG three times at PMOD and twice at the Southern Great Plains (SGP) facility to WISG-traceable pyrgeometers. The ACP and IRIS agreed within +/- 1 W/m2 to +/- 3 W/m2 in all comparisons, whereas the WISG references exhibit a 2-5 Wm2 low bias compared to the ACP/IRIS average, depending on the water vapor column, as noted in Grobner et al. [4]. Consequently, a case for changing the current WISG has been made by Grobner and Reda. However, during the five comparisons the column water vapor exceeded 8 mm. Therefore, it is recommended that more ACP and IRIS comparisons should be held under different environmental conditions and water vapor column content to better establish the traceability of these instruments to SI with established uncertainty.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Absolute radiometry and the solar constant

A series of active cavity radiometers (ACRs) are described which have been developed as standard detectors for the accurate measurement of irradiance in absolute units. It is noted that the ACR is an electrical substitution calorimeter, is designed for automatic remote operation in any environment, and can make irradiance measurements in the range from low-level IR fluxes up to 30 solar constants with small absolute uncertainty. The instrument operates in a differential mode by chopping the radiant flux to be measured at a slow rate, and irradiance is determined from two electrical power measurements together with the instrumental constant. Results are reported for measurements of the solar constant with two types of ACRs. The more accurate measurement yielded a value of 136.6 plus or minus 0.7 mW/sq cm (1.958 plus or minus 0.010 cal/sq cm per min).

Willson, R. C.↗

Evaluating the World Infrared Standard Group Field Campaign Report

The standard to which broadband infrared irradiance radiometers (pyrgeometers) are compared is called the World Infrared Standard Group (WISG), maintained in Davos, Switzerland, at the World Radiation Center. WISG consists of four pyrgeometers that were calibrated using the absolute sky-scanning radiometer (ASR; Philipona 2001). The U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) user facility has recently adopted this as its standard and all Eppley precision infrared radiometer (PIR) pyrgeometers in ARM are currently being calibrated by transfer calibrations from WISG. Subsequently, the ASR has fallen out of operation, Julian Gröbner (2012) developed the infrared integrating sphere (IRIS) radiometer, and Ibrahim Reda (2012) developed the absolute cavity pyrgeometer (ACP). The IRIS and ACP make absolute measurements of broadband downwelling infrared irradiance using different approaches. These two instruments have been compared to each other and to the WISG (Gröbner et al. 2014). The two newer instruments agreed within about 1 Wm-2 with each other, but not with the WISG, which was 2-5 Wm-2 lower depending on the column water vapor loading. Consequently, a case for changing the current WISG has been made by Gröbner and Reda, basing their suggestion on a total of nine hours of simultaneous IRIS and ACP comparison data as well as data from 177 clear-sky nights between the IRIS and WISG radiometers from October 2009 to December 2013 (Gröbner et al. 2014). These findings were later confirmed during the second International Pyrgeometer Comparison (IPgC-II) held in September/October 2015 at Physikalisch-Meteorologisches Observatorium Davos (PMOD)/World Radiation Center (WRC), bringing the total to about 20 hours of simultaneous ACP and IRIS measurements spread across two years and five days, in the mountainous environment of Davos. For this campaign, the WISG evaluation team deployed several instruments for absolute infrared radiation measurements and pyrgeometers that have been tied to the original standard (ASR) to ARM’s Southern Great Plains (SGP) atmospheric observatory in the fall of 2017. The experiment was carried out in two phases in order to increase the probability of collecting measurements at a range of water vapor column values, to which the measurements have shown some dependence. Phase 1 of the deployment ran from October 15 to 28, and Phase 2 ran from November 26 to December 9. Four redundant IRIS and two redundant ACP made coincident measurements during this time (the ASR no longer being available for comparison). The link to the WISG was provided by two pyrgeometers calibrated relative to the WISG prior to the campaign at SGP and also measuring coincidently with the two absolute radiometers. In addition, three of the original pyrgeometers directly tied to the original ASR were deployed. (See Figure 1 for instrument setup.) The experiment took place in the fall when water vapor columns were expected to range below and above the 1-cm level that is crucial for ferreting out the water vapor dependence of these measurements that has been noted in Gröbner et al. 2014 and other measurements. An additional source of longwave radiation flux observations was provided by the atmospheric emitted radiance interferometer (AERI). The AERI measures downwelling spectral radiance from 3.3 to 19 μm with a calibration that is better than 1% of the ambient radiance (Knuteson et al. 2004), and so serves as a potential source of evaluation for the WISG. The AERI’s field of view is 2 degrees, and is directed towards zenith. Earlier ARM projects led by Tony Clough as part of the Broadband Heating Rate Profile (BBHRP) effort demonstrated how to derive longwave flux from these zenith radiance observations.

AERI, instrument calibration, Southern Great Plain↗

NREL Comparison of Absolute Cavity Pyrgeometers and Pyrgeometers Traceable to the World Infrared Standard Group and the Infrared Integrating Sphere: September 23-October 4, 2019

The comparison of the absolute cavity pyrgeometers (ACPs) with a precision infrared radiometer (PIR) pyrgeometer traceable to the World Infrared Standard Group (WISG) and a Kipp & Zonen (KZ) pyrgeometer traceable to WISG and the InfraRed Integrating Sphere Radiometer (IRIS) was held during the National Renewable Energy Laboratory (NREL) Pyrheliometer Comparison (NPC-2019) from September 23 to October 4, 2019. Data from all instruments was collected during nighttime clear sky conditions only. The irradiance measured by the ACPs, PIR, and CG4 pyrgeometers collected 30 seconds during the measurement runs. The measurement runs lasted for two hours, while the calibration runs lasted for 6 minutes. During the comparison, the average (av) irradiance difference measured by three ACPs varied from 0.2 W/m 2 to 0.8 W/m 2 , with a standard deviation (sd) from 0.4 W/m 2 to 0.8 W/m 2 . The average irradiance difference measured by the three ACPs minus the irradiance measured by the PIR was 7.1 W/m 2 and sd 1.0 W/m 2 , and the average irradiance difference measured by the KZ traceable to WISG was 8.1 W/m2 and sd 0.9 W/m 2 , and average irradiance difference measured by the KZ traceable to IRIS was 4.0 W/m2 and sd 0.9 W/m 2 .

14 SOLAR ENERGY↗

Active cavity radiometer.

The active cavity radiometer (ACR) is a pyrheliometer that accurately defines the absolute radiation scale. The physics of the pyrheliometric method and the ACR approach to this method are presented in detail. A mathematical abstraction of the method is generated through a quasi-equilibrium analysis of the power balance of the ACR's cavity detector. An error analysis is carried out on the quasi-equilibrium equation to determine the uncertainties of ACR measurements relative to the absolute radiation scale. The uncertainty of ACR measurements as a function of irradiance level is presented in graphical form.

Willson, R. C.↗

Solar total irradiance observations by active cavity radiometers

Investigations have been conducted concerning the development of new cavity pyrheliometer for an absolute measurement of solar irradiance both in preflight testing of spacecraft and in flight experiments to measure the total solar flux. A series of instruments developed as part of this program are electrically self-calibrated cavity pyrheliometers whose mode of operation is characterized by the name Active Cavity Radiometer (ACR). The temperatures of their cavity sensors are servocontrolled, actively maintained at constant temperatures relative to their heat sinks by electrical heating. The solar irradiance is related to the International System of Units by measuring the difference in amount of electrical heating required with the cavity sensor alternately shaded and exposed to the sun. Studies conducted with the ACR are discussed. While variations of a few tenths of a percent in solar total irradiance lasting no more than a week or two have been detected, no long term trends were identified.

Willson, R. C.↗

Establishing the World Reference for Measuring the Atmospheric Longwave Irradiance with Traceability to the International System of Units

Advancing climate change research requires accurate and traceable measurement of atmospheric longwave irradiance. Measurement capabilities are limited to an estimated uncertainty of larger than +/- 6 W/m2 using the interim World Infrared Standard Group (WISG). Two independently designed and calibrated absolute radiometers measuring downwelling longwave irradiance were compared during five outdoor comparisons in 2013, 2015, and 2017 at the Physikalisch Meteorologisches Observatorium Davos World Radiation Center (PMOD/WRC) and the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement program (ARM) in the Southern Great Planes (SGP). Two Absolute Cavity Pyrgeometers (ACPs) developed by the National Renewable Energy Laboratory (NREL) and four Integrating Sphere Infrared Radiometers (IRISs) developed by PMOD/WRC took part in these intercomparisons.From the five comparisons, the difference between the irradiance measured by ACPs and IRISs varied from 0.2 W/m2 to 2.5 W/m2 based on atmospheric conditions, which is within the combined stated uncertainties of +/- 3 W/m2. The irradiance measured by the WISG is lower than the average irradiance measured by ACPs and IRISs. The magnitude of difference varied from 0.2 W/m2 to 6.6 W/m2 depending on the integrated water vapor. A concerted effort to establish a world reference for measuring the atmospheric longwave irradiance with lower uncertainty and with traceability to the International System of Units (SI) by using the ACPs and IRISs as the reference started at the World Meteorological Organization (WMO). The Commission for Instruments and Methods of Observation Commission (CIMO) Task Team on Radiation References (TT) meeting was held in 2017 at the National Physical Laboratory (NPL), in Teddington, United Kingdom to discuss specific recommendation on the traceability of the atmospheric longwave irradiance to the International System of units (SI).

14 SOLAR ENERGY↗