Search NASA⌕ Search

SEARCH · Search NASA

Results for “Absolute pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Evaluation of a Quartz Bourdon Pressure Gage of Wind Tunnel Mach Number Control System Application

A theoretical and experimental study was undertaken to determine the feasibility of using the National Transonic Facility's high accuracy Mach number measurement system as part of a closed loop Mach number control system. The theoretical and experimental procedures described are applicable to the engineering design of pressure control systems. The results show that the dynamic response characteristics of the NTF Mach number gage (a Ruska DDR-6000 quartz absolute pressure gage) coupled to a typical length of pressure tubing were only marginally acceptable within a limited range of the facility's total pressure envelope and could not be used in the Mach number control system.

Chapin, W. G.↗

Pressure-Sensor Assembly Technique

Nielsen Engineering & Research (NEAR) recently developed an ultrathin data acquisition system for use in turbomachinery testing at NASA Glenn Research Center. This system integrates a microelectromechanical- systems- (MEMS-) based absolute pressure sensor [0 to 50 psia (0 to 345 kPa)], temperature sensor, signal-conditioning application-specific integrated circuit (ASIC), microprocessor, and digital memory into a package which is roughly 2.8 in. (7.1 cm) long by 0.75 in. (1.9 cm) wide. Each of these components is flip-chip attached to a thin, flexible circuit board and subsequently ground and polished to achieve a total system thickness of 0.006 in. (0.15 mm). Because this instrument is so thin, it can be quickly adhered to any surface of interest where data can be collected without disrupting the flow being investigated. One issue in the development of the ultrathin data acquisition system was how to attach the MEMS pressure sensor to the circuit board in a manner which allowed the sensor s diaphragm to communicate with the ambient fluid while providing enough support for the chip to survive the grinding and polishing operations. The technique, developed by NEAR and Jabil Technology Services Group (San Jose, CA), is described below. In the approach developed, the sensor is attached to the specially designed circuit board, see Figure 1, using a modified flip-chip technique. The circular diaphragm on the left side of the sensor is used to actively measure the ambient pressure, while the diaphragm on the right is used to compensate for changes in output due to temperature variations. The circuit board is fabricated with an access hole through it so that when the completed system is installed onto a wind tunnel model (chip side down), the active diaphragm is exposed to the environment. After the sensor is flip-chip attached to the circuit board, the die is underfilled to support the chip during the subsequent grinding and polishing operations. To prevent this underfill material from getting onto the sensor s diaphragms, the circuit board is fabricated with two 25- micrometer-tall polymer rings, sized so that the diaphragms fit inside the rings once the chip is attached.

Pruzan, Daniel A.↗

Miniature capacitor functions as pressure sensor

Miniature capacitor operates as a differential pressure telemetry sensor during free flight of test model in a hypersonic wind tunnel. The capacitor incorporates a beryllium copper diaphragm. It is also used as an absolute pressure sensor.

Harrison, R. G.↗

Fire Suppression and Response

This report is concerned with the following topics regarding fire suppression:What is the relative effectiveness of candidate suppressants to extinguish a representative fire in reduced gravity, including high-O2 mole fraction, low -pressure environments? What are the relative advantages and disadvantages of physically acting and chemically-acting agents in spacecraft fire suppression? What are the O2 mole fraction and absolute pressure below which a fire cannot exist? What effect does gas-phase radiation play in the overall fire and post-fire environments? Are the candidate suppressants effective to extinguish fires on practical solid fuels? What is required to suppress non-flaming fires (smoldering and deep seated fires) in reduced gravity? How can idealized space experiment results be applied to a practical fire scenario? What is the optimal agent deployment strategy for space fire suppression?

Ruff, Gary A.↗

Flow Regime Transitions and Pressure Drop in Gas-Liquid Flows through Packed Beds in Microgravity

The Packed Bed Reactor Experiment (PBRE) focused on the hydrodynamics of gas-liquid flow in porous media, specifically on flow regime transition and pressure drop correlation. The reactor included a cylindrical test section of 60 cm in length, 5 cm in diameter and filled with 2 mm spherical glass beads. Liquid water and Nitrogen gas were flowed into a centrifugal phase separator after exiting the test section. Five absolute pressure transducers and two high-speed video cameras spanned the test section to measure the pressure drop and capture flow regime behavior. Video observations, analysis of pressure traces, and pressure drop data were used to identify flow patterns. It was found that the slope of pressure gradient data when plotted versus the gas or liquid Reynolds numbers changed when the flow regime changed. This observation was used to identify the flow regime boundaries. At high liquid flow rates (high interaction regime), dispersed bubble and pulse flow regimes were detected. At low liquid flow rates (low interaction regime), large bubble and gas channeling regimes were observed. The transition from the big bubble regime to the gas channeling regime occurred at a critical gas flow rate independent of the liquid flow rate. Similarly, the transition from the low interaction to the high interaction regime occurred at a critical liquid flow rate. For these different flow regimes, different two-phase flow friction factors and pressure gradient correlations were fitted as a function of the gas and liquid modified Reynolds numbers and Suratman number. It was found that in all the flow regimes the capillary contribution to the pressure drop is significant and can be as high as 90% of the total pressure drop.

Brian Motil↗

SHOOT flowmeter and pressure transducers

A venturi flowmeter has been designed and constructed for the Superfluid Helium On-Orbit Transfer (SHOOT) experiment. The calibration results obtained from the SHOOT venturi demonstrate the ability of the flowmeter to meet the requirements of the SHOOT experiment. Flow rates as low as 20 cu dm/h and as high as 800 cu dm/h have been measured. Performances of the SHOOT differential and absolute pressure transducers, which have undergone calibration and vibration tests, are also included. Throughout the tests, the responses of the transducers remained linear and repeatable to within + or - 1 percent of the full scales of the transducers.

Kashani, A.↗

Evacuation-induced pressure differentials in multilayer insulation systems

The pressure differentials induced across three types of multilayer insulation systems during evacuation have been measured and compared with values predicted using an idealized parallel plate geometric model. The systems tested were double-aluminized Mylar with a Tissuglas or silk net spacer and crinkled single-aluminized Mylar. Test samples were circular. The influence of purge gas type, layer density, sample diameter, and temperature was systematically investigated. The experimental approach was to measure the absolute pressure history and corresponding pressure differential induced across the insulation during evacuation. The measured pressure differentials were nondimensionalized and compared with those predicted by the parallel plate model as a function of Knudsen number. It was concluded that the parallel plate model is adequate for making engineering analyses. The influence of all parameters, except layer density, is well represented by the model. Representation of the influence of layer density is less satisfactory, but can be improved by modification of the flat plate model to allow for the more obvious practical nonidealities, such as crinkling, or the presence of a net spacer.

Glassford, A. P. M.↗

Ultra-high temperature stability Joule-Thomson cooler with capability to accomodate pressure variations

A Joule-Thomson cryogenic refrigeration system capable of achieving high temperature stabilities in the presence of varying temperature, atmospheric pressure, and heat load is provided. The Joule-Thomson cryogenic refrigeration system includes a demand flow Joule-Thomson expansion valve disposed in a cryostat of the refrigeration system. The expansion valve has an adjustable orifice that controls the flow of compressed gas therethrough and induces cooling and partial liquefaction of the gas. A recuperative heat exchanger is disposed in the cryostat and coupled to the expansion valve. A thermostatically self-regulating mechanism is disposed in the cryostat and coupled to the J-T expansion valve. The thermostatically self-regulating mechanism automatically adjusts the cross sectional area of the adjustable valve orifice in response to environmental temperature changes and changes in power dissipated at a cold head. A temperature sensing and adjusting mechanism is coupled to a cold head for adjusting the temperature of the cold head in response to the change in heat flow in the cold head. The temperature sensing and adjusting mechanism comprises a temperature sensitive diode, a wound wire heater, and an electrical feedback control circuit coupling the diode to the heater. An absolute pressure relief valve is interposed between the output of the cryostat and an exhaust port for maintaining a constant exhaust temperature in the refrigerating system, independent of the changes in atmospheric pressure.

Bard, Steven↗

Thermodynamic Activity Measurements with Knudsen Cell Mass Spectrometry

Coupling the Knudsen effusion method with mass spectrometry has proven to be one of the most useful experimental techniques for studying the equilibrium between condensed phases and complex vapors. The Knudsen effusion method involves placing a condensed sample in a Knudsen cell, a small "enclosure", that is uniformly heated and held until equilibrium is attained between the condensed and vapor phases. The vapor is continuously sampled by effusion through a small orifice in the cell. A molecular beam is formed from the effusing vapor and directed into a mass spectrometer for identification and pressure measurement of the species in the vapor phase. Knudsen cell mass spectrometry (KCMS) has been used for nearly fifty years now and continues to be a leading technique for obtaining thermodynamic data. Indeed, much of the well-established vapor specie data in the JANAF tables has been obtained from this technique. This is due to the extreme versatility of the technique. All classes of materials can be studied and all constituents of the vapor phase can be measured over a wide range of pressures (approximately 10(exp -4) to 10(exp -11) bar) and temperatures (500-2800 K). The ability to selectively measure different vapor species makes KCMS a very powerful tool for the measurement of component activities in metallic and ceramic solutions. Today several groups are applying KCMS to measure thermodynamic functions in multicomponent metallic and ceramic systems. Thermodynamic functions, especially component activities, are extremely important in the development of CALPHAD (Calculation of Phase Diagrams) type thermodynamic descriptions. These descriptions, in turn, are useful for modeling materials processing and predicting reactions such as oxide formation and fiber/matrix interactions. The leading experimental methods for measuring activities are the Galvanic cell or electro-motive force (EMF) technique and the KCMS technique. Each has specific advantages, depending on material and conditions. The EMF technique is suitable for lower temperature measurements, provided a suitable cell can be constructed. KCMS is useful for higher temperature measurements in a system with volatile components. In this paper, we briefly review the KCMS technique and identify the major experimental issues that must be addressed for precise measurements. These issues include temperature measurements, cell material and cell design and absolute pressure calibration. The resolution of these issues are discussed together with some recent examples of measured thermodynamic data.

Copland, Evan H.↗

Low cost, logarithmic mass flow computer

Computer solves the equation relating gas flow through a nozzle, venturi, or orifice to the absolute temperature, absolute pressure, and differential pressure of the fluid. Inexpensive method has high frequency response and provides true analog output.

Dolce, J. L.↗

A ground test measurement system for the shuttle entry air data system

The Ground Test Measurement System (GTMS) for determining vacuum decay leak rate within the orifice tubing assembly of SEADS is described. The system can also monitor the absolute pressure in the tubing assembly under certain conditions. The GTMS determines leak rate by measuring vacuum-pressure decay which can be converted into leakage flow rate. Results of performance testing and operation of the GTMS are given.

Schutte, P. C.↗

Atomization and combustion performance of antimisting kerosene and jet fuel

Combustion performance of antimisting kerosene (AMK) containing FM-9 polymer was investigated at various levels of degradation (restoration of AMK for normal use in a gas turbine engine). To establish the relationship of degradation and atomization to performance in an aircraft gas turbine combustor, sprays formed by the nozzle of a JT8-D combustor with Jet A and AMK at 1 atmosphere (atm) (14.1 lb/square in absolute) pressure and 22 C at several degradation levels were analyzed. A new spray characterization technique based on digital image analysis of high resolution, wide field spray images formed under pulsed ruby laser sheet illumination was developed. Combustion tests were performed for these fuels in a JT8-D single can combustor facility to measure combustion efficiency and the lean extinction limit. Correlation of combustion performance under simulated engine operating conditions with nozzle spray Sauter mean diameter (SMD) measured at 1 atm and 22 C were observed. Fuel spray SMD and hence the combustion efficiency are strongly influenced by fuel degradation level. Use of even the most highly degraded AMK tested (filter ratio = 1.2) resulted in an increase in fuel consumption of 0.08% to 0.20% at engine cruise conditions.

Fleeter, R.↗

Can plants grow in quasi-vacuum?

It was found that the growth of plants is possible under absolute pressure 14 times lower than the atmospheric pressure. In first approximation, plants ignore the absence of nitrogen and only react to the partial pressure of O2. Hence the growth of plantlets was delayed under low pressures of O2 in both cases with and without nitrogen. The CO2 availability being limited by the carbon content of the seed, the final results after 20 days were very similar.

Andre, M.↗

The NASA Langley 0.3-m transonic cryogenic tunnel

The Langley 0.3-m Transonic Cryogenic Tunnel (0.3-m TCT) can operate from ambient to cryogenic temperatures at absolute pressures from 1 to 6 bars. Since the 0.3-m TCT began operation in 1973, it has been used to develop instrumentation and operating techniques for cryogenic tunnels as well as for aerodynamic tests where advantage can be taken of the extremely wide range of Reynolds number available. This paper describes the present capabilities of the 0.3-m TCT and gives an overview of recent research activities which include both steady and unsteady testing. Emphasis is given to safety and the development of testing techniques for cryogenic tunnels. Results of studies aimed at establishing the lower limits of operating temperature are presented and the impact of these studies on tunnel operation is discussed. Finally, the design features and operating characteristics of a new self-streamlining wall test section recently installed in the tunnel circuit are described.

Kilgore, R. A.↗

Observations of columnal recombination in the ionization tracks of energetic heavy nuclei in an argon-methane gas mixture

Measurements of ionization signals resulting from the passage of energetic heavy nuclei through a gas mixture consisting of 95 mol percent Ar plus 5 mol percent CH4, at an absolute pressure of 3 atm are presented. The measurements take place under a uniform electric field perpendicular to the ionization track. The signals were compared to the calculated energy losses, with an assumption of proportionality between energy loss rate and ionization rate. Significant deviations from proportionality are found for energy loss rate grater than about 3000 MeV sq cm/g, while fractional deviations are found to be proportional to the energy loss rate (dE/dx) exp m, where m is equal to about two. These results are attributed to the columnal recombination.

Wiedenbeck, Mark E.↗

Joule-Thomson Cooler Produces Nearly Constant Temperature

Improved Joule-Thomson cooler maintains nearly constant temperature. Absolute-pressure relief valve helps stabilize temperature of cold head despite variations in atmospheric pressure. Feedback-controlled electrical heater provides additional stabilization. Demand-flow Joule-Thomson valve requires less nitrogen than fixed-orifice Joule-Thomson valve providing same amount of cooling. Provides stable low temperatures required for operation of such devices as tunable diode lasers in laboratory and balloon-borne instruments detecting contaminants in atmosphere.

Bard, Steven↗

Temperature dependence of the ClONO2 UV absorption spectrum

The temperature dependence of the ClONO2 absorption spectrum has been measured between 220 and 298 K and between 195 and 430 nm using a diode array spectrometer. The absorption cross sections were determined using both: (1) absolute pressure measurements at 296 K and (2) measurements at various temperatures relative to 296 K using a dual absorption cell arrangement. The temperature dependence of the ClONO2 absorption spectrum shows very broad structure. The amplitude of the temperature dependence relative to that at 296 K is weak at short wavelengths, less than 2% at 215 nm and 220 K, but significant at the wavelengths important in the stratosphere, about 30% at 325 nm and 220 K. Our ClONO2 absorption cross section data are in good general agreement with the previous measurements of Molina and Molina (1979).

Burkholder, James B.↗

Temperature dependence of the HNO3 UV absorption cross sections

The temperature dependence of the HNO3 absorption cross sections between 240 and 360 K over the wavelength range 195 to 350 nm has been measured using a diode array spectrometer. Absorption cross sections were determined using both (1) absolute pressure measurements at 298 K and (2) a dual absorption cell arrangement in which the absorption spectrum at various temperatures is measured relative to the room temperature absorption spectrum. The HNO3 absorption spectrum showed a temperature dependence which is weak at short wavelengths but stronger at longer wavelengths which are important for photolysis in the lower stratosphere. The 298 K absorption cross sections were found to be larger than the values currently recommended for atmospheric modeling (DeMore et al., 1992). Our absorption cross section data are critically compared with the previous measurements of both room temperature and temperature-dependent absorption cross sections. Temperature-dependent absorption cross sections of HNO3 are recommended for use in atmospheric modeling. These temperature dependent HNO3 absorption cross sections were used in a two-dimensional dynamical-photochemical model to demonstrate the effects of the revised absorption cross sections on loss rate of HNO3 and the abundance of NO2 in the stratosphere.

Burkholder, James B.↗