Search NASA⌕ Search

SEARCH · Search NASA

Results for “Absorber design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Effective design of vibro-impact energy harvesting absorbers with asymmetric stoppers

We report that an investigation is carried out for the purpose of simultaneously controlling a base-excited dynamical system and enhancing the effectiveness of a piezoelectric energy harvesting absorber. Amplitude absorbers are included to improve the energy harvested by the absorber with the possibility of activating broadband resonant regions to increase the operable range of the absorber. This study optimizes the stoppers’ ability for the energy harvesting absorber to generate energy by investigating asymmetric gap and stiffness configurations. Medium stiffnesses of 5 x 10 4 N/m and 1 x 10 5 N/m show significant impact on the primary system’s dynamics and improvement in the level of the harvested power for the absorber. A solo stopper configuration when the gap distance is 0.02m improves 29% in peak power and 9% in average power over the symmetrical case. Additionally, an asymmetric stiffness configuration when one of the stiffnesses is 1 x 10 5 N/m and a gap size of 0.02m indicates an improvement of 25% and 8% for peak and average harvested power, respectively, and the second stopper’s stiffness is 5 x 10 3 N/m. Hard stopper configurations shows improvements with both asymmetric cases, but not enough improvements to outperform the system without amplitude stoppers.

42 ENGINEERING↗

Final Design for Thermal/Epithermal eXperiments (TEX) with Lithium Absorbers to Provide Validation Benchmarks for Y-12 Electrorefining Facility (IER 575, CED-2 Report)

One of the main goals of the Thermal/Epithermal eXperiments (TEX) project is to use existing Nuclear Criticality Safety Program (NCSP) assets to create critical experiment plutonium and uranium test beds for materials important to criticality safety that have insufficient benchmark evaluations. The plutonium test bed experiments were completed in 2018 and are published in the 2020 edition of the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The uranium test bed assemblies were completed in 2023 and accepted in the 2024 edition of the ICSBEP Handbook.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Chiral plasmonic metasurface absorbers in the mid-infrared wavelength range

Chiral metamaterials in the mid-infrared wavelength range have tremendous potential for studying thermal emission manipulation and molecular vibration sensing. In this work, we present one type of chiral plasmonic metasurface absorber with high circular dichroism (CD) in absorption of more than 0.56 across the mid-infrared wavelength range of 5-5.5 mu m. The demonstrated chiral metasurface absorbers exhibit a maximum chiral absorption of 0.87 and a maximum CD in absorption of around 0.60. By adjusting the geometric parameters of the unit cell structure of the metasurface, the chiral absorption peak can be shifted to different wavelengths. Due to the strong chiroptical response, the thermal analysis of the designed chiral metasurface absorber further shows the large temperature difference between the left-handed and right-handed circularly polarized light. The demonstrated results can be utilized in various applications such as molecular detection, mid-infrared filter, thermal emission, and chiral imaging.

42 ENGINEERING↗

Effect of Nuclear Data Covariances on Integral Experiment Design with Sensitivity and Uncertainty Analysis

Washington River Protection Solutions (WRPS) uses MCNP6.2 and the Whisper code for criticality safety analyses of the Hanford Tank Farm. Together the codes derive baseline upper subcritical limits (USLs) for the waste models using experimental benchmarks. Whisper returns higher USLs, i.e. , has less of a conservative penalty, when the neutronic similarity of the experimental benchmarks to the application is high. Unfortunately, few critical benchmarks have high similarity to the Hanford tanks. The waste in the tanks is highly dilute in plutonium and contains large masses of weakly neutron-absorbing elements like iron and manganese. Experimental benchmarks typically have low sensitivity to these absorbers because they are present as structural materials. Lacking similar benchmarks, new Thermal Epithermal eXperiment (TEX) configurations with high Pu content and interstitial iron absorbers have been designed for the criticality safety validation. The features of the design have been iterated upon to maximize the similarity between the experiment and different Hanford waste models. The similarity is quantified with sensitivity analysis and uncertainty quantification using the representativity coefficient, or c k . The representativity calculation requires nuclear data covariances, which may differ between nuclear data libraries and between library versions. Because of these variations, the optimal design may depend on the nuclear data covariances library. A scenario can be envisioned where an experiment is designed, and c k is maximized, with one set of covariance data. However, when the covariance data is changed, say from ENDF/B-VII.1 to ENDF/B-VIII.0, and the benchmark is used in a criticality safety evaluation, the experiment becomes suboptimal with respect to c k . In this paper, we present how the optimal design of the new TEX experiments varied depending on the nuclear data covariances used to calculate c k . We compare ENDF/B-VII.1 and ENDF/B-VIII.0, as if the library had been updated since the design of the experiment. Additionally, we use JEFF3.3 to simulate if the covariance data of a different library had been used. The results show that the covariances do have an important effect on the designs, less so for thermal systems (where the data are more consistent between evaluations) and more so for epithermal systems where more differences exist.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Perfect absorption in GaAs metasurfaces near the bandgap edge

Perfect optical absorption occurs in a metasurface that supports two degenerate and critically-coupled modes of opposite symmetry. The challenge in designing a perfectly absorbing metasurface for a desired wavelength and material stems from the fact that satisfying these conditions requires multi-dimensional optimization often with parameters affecting optical resonances in non-trivial ways. This problem comes to the fore in semiconductor metasurfaces operating near the bandgap wavelength, where intrinsic material absorption varies significantly. Here we devise and demonstrate a systematic process by which one can achieve perfect absorption in GaAs metasurfaces for a desired wavelength at different levels of intrinsic material absorption, eliminating the need for trial and error in the design process. Using this method, we show that perfect absorption can be achieved not only at wavelengths where GaAs exhibits high absorption, but also at wavelengths near the bandgap edge. In this region, absorption is enhanced by over one order of magnitude compared a layer of unstructured GaAs of the same thickness.

Hale, L. L. (ORCID:0000000176544272)↗

Conceptual Design and Analysis of In-Vessel Components for the Materials Plasma Exposure eXperiment (MPEX)

The materials plasma exposure experiment (MPEX) is a linear plasma divertor simulator currently undergoing conceptual design. The facility will expose material samples to steady-state plasma fluxes to examine plasma–material interactions (PMIs) that are expected in the next generation of fusion devices. The plasmas will be generated by a helicon source, with electron and ion heating sources of up to 800 kW possible. The peak heat fluxes of the target are expected to be up to 10 MW/m 2 . The facility will be capable of handling low-activation neutron-irradiated samples in order to examine the multivariate effects of neutron damage and plasma fluence. Neutron-irradiated samples are planned to be roughly of 10-mm diameter; however, plasma-facing components up to 60×600 mm can be accommodated. The steady-state nature of the device will require the magnetic confinement of the plasma to be achieved with superconducting magnets, with a maximum on-axis field of 2.5 T. In addition, since MPEX will be a steady-state device, in-vessel components need to be water cooled. The primary in-vessel components will be the target, the dump plate, the limiter, the skimmers, and the microwave absorber. The conceptual design of these components is presented here, including analyses that confirm that the designs are adequate to meet the requirements of MPEX operation.

Lumsdaine, Arnold↗

Design of a Molten Salt Flow Cell for Combined Absorbance and Laser-Induced Breakdown Spectroscopy for Online Measurements

A novel flow cell allowing for multiple optical spectroscopy measurements on flowing molten salts was designed, and demonstrative calibrations of impurities in aqueous samples were performed. Online compositional measurements of molten salts are of high interest to monitor the state of relevant solar and nuclear systems. Here, the Spectroscopic Configuration for Optical Real-Time Characterization of High-Temperature (SCORCH) fluids cell was designed to meet this need by providing optical access to a high-temperature molten salt sample stream without physical contact between the sample and window materials. Laser-induced breakdown spectroscopy (LIBS) was utilized to quantify Li, Cr, Fe, Ni, Sr, and Pr at concentrations ranging nominally from 0 to 315 mmol L −1 . Laser power, frequency, and plasma position were optimized to mitigate challenges associated with sample splashing. Univariate calibration models were built with R 2 > 0.98, percent root mean square error of cross-validation (%RMSECV) as low as 2.7%, and limits of quantification (LOQs) down to 4.1 mmol L −1 . Simultaneously, absorbance calibrations were developed for the applicable analytes (Cr, Ni, and Pr) using Beer’s law with a pathlength of 4.41 ± 0.10 mm. These models provide excellent quantification performance with R 2 > 0.999, %RMSECV as low as 0.6%, and LODs down to 0.08 mmol L −1 . Although these calibrations were performed for each spectroscopic technique separately, the two methods may be combined in the future through multivariate modeling and sensor fusion to provide more robust models with the benefits of both techniques (e.g., absorbance: oxidation state concentrations, LIBS: elemental concentration). Additionally, optimized spectrometers may be deployed to enhance sensitivity.

absorbance spectroscopy↗

TEM Characterization of Neutron Irradiated HfAl3-Al Composite Specimens

Particles comprised of a thermal neutron absorbing material (HfAl3) are dispersed in a metal matrix material with high thermal conductivity (aluminum) to conduct the heat generated by neutron capture away from the fuel and materials. This metal matrix composite is very promising for use as a conduction-cooled neutron absorber and has the potential to be useful as a shroud or heat sink for testing advanced fast reactor fuels and materials in an existing thermal reactor. To design and optimize the absorber block system for advanced reactor designs, fundamental understanding of the irradiation effect on material properties is necessary. This dataset contains TEM characterization results of neutron irradiated HfAl3-Al composite specimens. It is focused on the irradiation induced defects (dislocation lines and loops) characterization using the on-zone axis bright field STEM technique. This data was collected using a FEI Tecnai G2 F30 S/TEM at the Microscopy and Characterization Suite (MaCS), Center for Advanced Energy Studies (CAES).

Guillen, Donna↗

TEM Characterization of Neutron Irradiated HfAl3-Al Composite Specimens

Particles comprised of a thermal neutron absorbing material (HfAl3) are dispersed in a metal matrix material with high thermal conductivity (aluminum) to conduct the heat generated by neutron capture away from the fuel and materials. This metal matrix composite is very promising for use as a conduction-cooled neutron absorber and has the potential to be useful as a shroud or heat sink for testing advanced fast reactor fuels and materials in an existing thermal reactor. To design and optimize the absorber block system for advanced reactor designs, fundamental understanding of the irradiation effect on material properties is necessary. This dataset contains TEM characterization results of neutron irradiated HfAl3-Al composite specimens. It is focused on the irradiation induced defects (dislocation lines and loops) characterization using the on-zone axis bright field STEM technique. This data was collected using a FEI Tecnai G2 F30 S/TEM at the Microscopy and Characterization Suite (MaCS), Center for Advanced Energy Studies (CAES).

Guillen, Donna↗

Optimizing Ammonia Separation via Reactive Absorption for Sustainable Ammonia Synthesis

Metal halide salts such as magnesium chloride have been shown to be promising candidates for ammonia storage materials for energy storage and agriculture applications due to their ability to incorporate several moles of ammonia per mole of salt. Ammonia exiting a synthesis reactor can be separated from nitrogen and hydrogen by absorption into magnesium chloride. Such an absorption can be more complete and hotter than separation via ammonia condensation, the current standard in the Haber–Bosch process. Here, we discuss the optimal conditions for the cyclic uptake and release of ammonia from the supported magnesium chloride absorbents. An automated system was designed for measuring the nonequilibrium working capacity of the absorbent, as well as the impact of important operating conditions such as absorption and desorption temperature, pressure, and desorption time. Measurements of absorption and desorption kinetics provide insight into the mechanisms involved. The temperatures and pressures during absorption and desorption were designed to use minimal energy input to maximize the uptake and release of ammonia within a reasonable amount of time. In a laboratory-scale bed, absorption has a small unused bed length, so it is largely independent of mass transfer; it is dominated by how fast ammonia is fed to the bed. Yet, desorption is restricted both by the speed of heating the bed and by diffusion out of the absorbent. These measurements provide guidelines for ammonia separations and cycling sorbent materials on a larger scale.

10 SYNTHETIC FUELS↗

Final Design for Additional Thermal/Epithermal eXperiments (TEX) with Sodium Chloride Absorbers to Provide Validation Benchmarks for TerraPower

The first set of Thermal/Epithermal eXperiments (TEX) with chlorine absorbers (TEX-Cl) were executed in Q4FY24 and are in the process of being benchmarked for the ICSBEP. TEX-Cl builds upon the TEX-HEU baseline cases that were published in the 2022 International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. TEX-HEU, like TEX-Pu, was designed to be modular to allow for the incorporation of various absorbers and reflectors to test nuclear data and application case needs. For example, TEX-HEU with hafnium (TEX-Hf) utilizes hafnium plates as both absorbers and reflectors, depending on the tested configuration. A second set of chlorine experiments, dubbed More TEX-Cl, are laid out in this report to meet the needs of TerraPower for chlorine validation for their Molten Chloride Fast Reactor (MCFR) systems. TerraPower’s Molten Chloride Reactor Experiment (MCRE) and MCFR are fast molten salt reactors that utilize sodium chloride (NaCl) salt eutectics as the fuel and coolant. The MCRE eutectic is a mixture of NaCl and uranium trichloride (UCl 3 ). An abundant need for chlorine absorption validation has been expressed by multiple members of the community, including Y-12 (whose needs were addressed with the first set of experiments), LANL (whose needs were addressed with the Chlorine Worth Study (CWS)), TerraPower, institute de radioprotection et de sûreté nucléaire (IRSN), Savannah River Nuclear Solutions (SNRS), and others. Of the members who have expressed interest in this validation, most are interested in the fast neutron energy region, where the 35 Cl(n,p) reaction is most prominent. New 35 Cl(n,p) differential cross section measurements performed by LANL at LANCSE show substantial changes to the cross sections (Figure 1) and may be validated through these experiments as some configurations are optimally sensitive to this cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hafnium Absorber Latching Mechanism Redesign

The poster entails the known problems and updated design solutions for the hafnium absorber latching mechanism. The hafnium absorber latching mechanism is a part of the safety rod system located within ATR's core. The latching mechanism's primary function was to attach hafnium absorbers to the safety rod drive system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A MEMS dynamic mechanical analyzer for in situ viscoelastic characterization of 3D printed nanostructures

Cellular metamaterial structures with sub-micron features have shown the ability to become excellent energy absorbing materials for impact mitigation due to the enhanced mechanical properties of materials at the nanoscale. However, in order to optimize the design of these energy absorbing metamaterial structures we need to be able to measure the dynamic properties of the sub-micron features such as storage and loss moduli and the loss factor. Therefore, at scale testing is required to capture the scale, temperature, and strain rate dependent material properties of these nanoscale materials. This study presents the design, fabrication, and calibration of a MEMS-based dynamic mechanical analyzer (DMA) that can be directly integrated with the two photon lithography (TPL) process commonly used to fabricate metamaterial structures with nanoscale features. The MEMS-based DMA consists of a chevron style thermal actuator used to generate a tensile load on the structure and two differential capacitive sensors on each side of the structure used to measure load and displacement. This design demonstrated 1.5 ± 0.75 nm displacement resolution and 104 ± 52 nN load resolution, respectively. Dynamic mechanical analysis was successfully conducted on a single nanowire feature printed between the load and displacement stages of the MEMS device with testing frequencies ranging between 0.01–10 Hz and testing temperatures ranging between 22 °C–47 °C. These initial tests on an exemplar TPL part demonstrate that the printed nanowire behaves as a viscoelastic material wherein the transition from glassy to viscous behavior has already set in at the room temperature.

42 ENGINEERING↗

Property optimized energy absorber for automotive bumpers utilizing multi-material and structural design strategies

This study proposes a novel design for automotive bumper using optimized lattice structures and multi-materials to balance low-speed collision and high-speed pedestrian impact performance. Different blends of 20 % carbon fiber-reinforced acrylonitrile butadiene styrene with thermoplastic polyurethane were used to tailor material properties. The energy absorber features lattice structures with customized mechanical responses, created by varying the incline angle θ from 0 to 180°. We conducted 576 finite element simulations on a half-scale model to optimize energy absorption and stiffness, leading to 66 optimized designs that met both low-speed and high-speed impact criteria. Two sub-scale optimized energy absorbers with different peak forces—both meeting low-speed impact requirements—were 3D printed and validated through drop-weight testing. The one with lower peak stress demonstrated a more compliant response, exhibiting approximately 90 % lower initial peak force and an increase in energy absorption of around 33 % (from 24 J to 32 J). Compared to the baseline triangular lattice, the optimized absorber increased energy absorption by 68 % from (19 J to 32 J) and reduced peak stress by 70 %. It also showed near-complete recovery with minimal fractures, making it suitable for repeated use. This design improves safety while offering a lightweight, durable, and cost-effective bumper system.

36 MATERIALS SCIENCE↗