Search NASA⌕ Search

SEARCH · Search NASA

Results for “Absorption spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Kramers–Kronig relation in attosecond transient absorption spectroscopy

The Kramers–Kronig relation (KKR) has a wide range of applications in extreme ultraviolet (XUV) and x-ray spectroscopy. However, the validity of KKR for many of these applications has not been systematically studied, while it is known to require careful attention in nonlinear and pump–probe experiments in optical domain spectroscopy. Here, we study the validity of KKR in XUV attosecond transient absorption spectroscopy pump–probe measurements both experimentally and theoretically using argon Fano resonances as a case study. Experiments are enabled by a phase-resolved method dubbed Complex Attosecond Transient-absorption Spectroscopy (CATS). Although the estimations based on the rotating-wave approximation suggest that KKR violation could be expected in the studied case, our results validate KKR and provide a solid basis for its application in a broad range of attosecond spectroscopy experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray absorption spectroscopy measurements of radiatively ionized argon gas

X-ray absorption spectroscopy is a diagnostic tool that can characterize the temperature and ionization state of a plasma. This technique requires experiments to characterize the platform, careful data calibration, and comparison with atomic models to understand the plasma parameters. We performed ionizing radiation wave experiments at the OMEGA Laser Facility that used an ∼ 80 eV X-ray source to heat an Argon (Ar) gas cell at fill pressures of 3 atm. To diagnose the Ar plasma, we used a capsule backlighter offset 10 mm from the gas cell, to produce X-rays that were absorbed by the ionized Ar gas. The absorption analysis was calibrated using the significant line structure in the backlighter spectrum, which served as independent energy fiducials enabling definitive measurements of a 50-eV shift in the energy of the Ar K-edge due to ionization. We compare the measured absorption spectra to two independent atomic models, PrismSPECT and SCRAM, and show that the observed K-edge shift in the heated gas is consistent with ionization up to Ar 4+ and temperatures of 10 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Open-source electrochemical cell for in situ X-ray absorption spectroscopy in transmission and fluorescence modes

X-ray spectroscopy is a valuable technique for the study of many materials systems. Characterizing reactions in situ and operando can reveal complex reaction kinetics, which is crucial to understanding active site composition and reaction mechanisms. In this project, the design, fabrication and testing of an open-source and easy-to-fabricate electrochemical cell for in situ electrochemistry compatible with X-ray absorption spectroscopy in both transmission and fluorescence modes are accomplished via windows with large opening angles on both the upstream and downstream sides of the cell. Using a hobbyist computer numerical control machine and free 3D CAD software, anyone can make a reliable electrochemical cell using this design. Onion-like carbon nanoparticles, with a 1:3 iron-to-cobalt ratio, were drop-coated onto carbon paper for testing in situ X-ray absorption spectroscopy. Cyclic voltammetry of the carbon paper showed the expected behavior, with no increased ohmic drop, even in sandwiched cells. Chronoamperometry was used to apply 0.4 V versus reversible hydrogen electrode, with and without 15 min of oxygen purging to ensure that the electrochemical cell does not provide any artefacts due to gas purging. The XANES and EXAFS spectra showed no differences with and without oxygen, as expected at 0.4 V, without any artefacts due to gas purging. The development of this open-source electrochemical cell design allows for improved collection of in situ X-ray absorption spectroscopy data and enables researchers to perform both transmission and fluorescence simultaneously. It additionally addresses key practical considerations including gas purging, reduced ionic resistance and leak prevention.

08 HYDROGEN↗

Recommendations to standardize reporting, execution, and interpretation of X-ray Absorption Spectroscopy measurements

In July of 2022, a National Science Foundation (NSF)- and US Department of Energy (DOE)-sponsored workshop was held on the topic of rigor and reproducibility (R&R) in thermal, heterogeneous catalysis. As a result of the workshop, a report has been published entitled "Addressing Rigor and Reproducibility in Thermal, Heterogeneous Catalysis"[1]. This manuscript summarizes one section of the report: "Recommendations for catalyst characterization by X-ray absorption spectroscopy". Here, the section focuses exclusively on X-ray absorption spectroscopy (XAS) and is narrowly focused on recommendations for the collection and interpretation of XAS data for routine experiments. Therefore, one should not expect a detailed guide for each different experiment that one may perform nor are the recommendations designed to be overly prescriptive. However, the report is designed to draw attention to key pitfalls and common problems in the collection, reporting, analysis and interpretation of XAS studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Flat Analyzer Polycapillary Spectrometer for X-ray Absorption Spectroscopy of Dilute Transition Metals at X-ray-Free Electron Lasers

X-ray absorption spectroscopy (XAS) coupled with highly intense pulses from an X-ray-free electron laser (XFEL) can be used to track ultrafast chemical dynamics. Nonetheless, measurements for dilute samples (≤1 mM) have been exceptionally challenging, as scattering background signals dominate over the sample’s X-ray fluorescence. We show that femtosecond time-resolved XAS measurements of sub-millimolar transition metal solutions are now possible at the Linac Coherent Light Source (LCLS) using a high-throughput polycapillary XAS spectrometer, designed, developed, and commissioned at LCLS and the Stanford Synchrotron Radiation Lightsource (SSRL). The instrument integrates three polycapillary optics that collect and collimate X-ray fluorescence emitted from the interaction point with a high solid angle. X-ray collimated fluorescence is then selectively diffracted by coupled graphite analyzer crystals. As a result, the contribution of scattered photons is suppressed. Experiments at the Pt L 3 -edge on 0.1 mM aqueous K 2 PtCl 6 (delivered via a 100 μm liquid jet) were successfully performed in the laser pump X-ray probe configuration at the LCLS XCS and XPP instruments. We report the transient spectra of hexachloroplatinate within the first 10 ps after a 266 nm photoexcitation. We observed a short-lived reduced intermediate (≈2 ps). The polycapillary X-ray spectrometer at LCLS now enables the efficient study of the dynamics of ultradilute transition metals in solution. This capability opens the door to investigating plasmonic systems, photocatalysts, enzymes, and other scarce and dilute samples.

LCLS↗

Space Launch System Base Heating Test: Tunable Diode Laser Absorption Spectroscopy

This paper describes the Tunable Diode Laser Absorption Spectroscopy (TDLAS) measurement of several water transitions that were interrogated during a hot-fire testing of the Space Launch Systems (SLS) sub-scale vehicle installed in LENS II. The temperature of the recirculating gas flow over the base plate was found to increase with altitude and is consistent with CFD results. It was also observed that the gas above the base plate has significant velocity along the optical path of the sensor at the higher altitudes. The line-by-line analysis of the H2O absorption features must include the effects of the Doppler shift phenomena particularly at high altitude. The TDLAS experimental measurements and the analysis procedure which incorporates the velocity dependent flow will be described.

Parker, Ron↗

Space Launch System Base Heating Test: Tunable Diode Laser Absorption Spectroscopy

This paper describes the Tunable Diode Laser Absorption Spectroscopy (TDLAS) measurement of several water transitions that were interrogated during a hot-fire testing of the Space Launch Systems (SLS) sub-scale vehicle installed in LENS II. The temperature of the recirculating gas flow over the base plate was found to increase with altitude and is consistent with CFD results. It was also observed that the gas above the base plate has significant velocity along the optical path of the sensor at the higher altitudes. The line-by-line analysis of the H2O absorption features must include the effects of the Doppler shift phenomena particularly at high altitude. The TDLAS experimental measurements and the analysis procedure which incorporates the velocity dependent flow will be described.

Parker, Ron↗

Detection limits for laser absorption spectroscopy of Li in laser ablation plumes

A high-sensitivity laser absorption spectroscopy (LAS) method is demonstrated for rapid and non-contact analysis of Li in solids. Glass samples with Li concentrations ranging from 1-500 ppm by mass are ablated in 5 Torr air, and time-resolved Li atomic absorption is measured using a tunable laser near 671 nm. Significant improvements in analytical performance over prior laser-induced breakdown techniques are demonstrated. Here, a single-shot limit of detection (LOD) of 180 ppb is shown for fixed wavelength operation, improving to 6 ppb with averaging over 1000 ablation shots (100 s acquisition time). Isotope-resolved Li absorption spectra are measured with a 17 ppb LOD in 40 s. Methods for optimizing LOD based on noise/averaging properties of LAS experiments in LA plumes are discussed.

(020.3260) Isotope shifts↗

Asynchronous x-ray multiprobe data acquisition for x-ray transient absorption spectroscopy

Laser pump X-ray Transient Absorption (XTA) spectroscopy offers unique insights into photochemical and photophysical phenomena. X-ray Multiprobe data acquisition (XMP DAQ) is a technique that acquires XTA spectra at thousands of pump-probe time delays in a single measurement, producing highly self-consistent XTA spectral dynamics. In this work, we report two new XTA data acquisition techniques that leverage the high performance of XMP DAQ in combination with High Repetition Rate (HRR) laser excitation: HRR-XMP and Asynchronous X-ray Multiprobe (AXMP). HRR-XMP uses a laser repetition rate up to 200 times higher than previous implementations of XMP DAQ and proportionally increases the data collection efficiency at each time delay. This allows HRR-XMP to acquire more high-quality XTA data in less time. AXMP uses a frequency mismatch between the laser and x-ray pulses to acquire XTA data at a flexibly defined set of pump-probe time delays with a spacing down to a few picoseconds. AXMP introduces a novel pump-probe synchronization concept that acquires data in clusters of time delays. Further, the temporally inhomogeneous distribution of acquired data improves the attainable signal statistics at early times, making the AXMP synchronization concept useful for measuring sub-nanosecond dynamics with photon-starved techniques like XTA. In this paper, we demonstrate HRR-XMP and AXMP by measuring the laser-induced spectral dynamics of dilute aqueous solutions of Fe(CN) 6 4₋ and [Fe II (bpy) 3 ] 2+ (bpy: 2,2'-bipyridine), respectively.

47 OTHER INSTRUMENTATION↗

A Portable Nitrogen Dioxide Instrument Using Cavity-Enhanced Absorption Spectroscopy

The Portable (2.7 kg) Cavity-enhanced Absorption of Nitrogen Dioxide (PCAND) instrument for measuring in situ nitrogen dioxide (NO2) was developed using incoherent, broadband cavity-enhanced absorption spectroscopy (IBBCEAS). An LED light source centered at 408 nm was coupled to a cavity 15 cm in length, achieving an effective optical pathlength of ~520 m. Our precision was measured as 94 pptv (1 s). To date, we have flown this instrument on 3 balloon and 1 UAV test flights. This instrument records data to an SD card and outputs data (via an RS232 port) to external devices including a commercial radiosonde (iMet) for real-time data downlink.

TROPOMI↗

The Coordination Behaviour of Cu I Photosensitizers Bearing Multidentate Ligands Investigated by X-ray Absorption Spectroscopy

A systematic series of four novel homo- and heteroleptic CuI photosensitizers based on tetradentate 1,10-phenanthroline ligands of the type X^N^N^X containing two additional donor moieties in the 2,9-position (X=SMe or OMe) were designed. Their solid-state structures were assessed by X-ray diffraction. Cyclic voltammetry, UV-vis absorption, emission and X-ray absorption spectroscopy were then used to determine their electrochemical, photophysical and structural features in solution. Following, time-resolved X-ray absorption spectroscopy in the picosecond time scale, coupled with time-dependent density functional theory calculations, provided in-depth information on the excited state electron configurations. For the first time, a significant shortening of the Cu–X distance and a change in the coordination mode to a pentacoordinated geometry is shown in the excited states of the two homoleptic complexes. These findings are important with respect to a precise understanding of the excited state structures and a further stabilization of this type of photosensitizers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing Distinctive Redox Mechanism in Ni-Rich Cathode Via Real-Time Quick X-Ray Absorption Spectroscopy

X-ray radiation damage on the measuring system has been a critical issue regularly for a long-time exposure to X-ray beam during the in operando characterizations, which is particularly severe when the applied X-ray energy is near the absorption edges (M, L, K, etc.) of the interest element. Here, to minimize the negative effects raised by beam radiation, we employ quick X-ray absorption spectroscopy (QXAS) to study the electrochemical reaction mechanism of a Ni-rich layered structure cathode for lithium-ion batteries. With the advanced QXAS technique, the electronic structure and local coordination environment of the transition metals (TMs) are monitored in-operando with limited radiation damage. Compared to the conventional step-mode X-ray absorption spectroscopy, the QXAS can provide more reliable oxidation state change and more detailed local structure evolutions surrounding TMs (Ni and Co) in Ni-rich layered oxides. By leveraging these advantages of QXAS, we demonstrated that the Ni dominates the electrochemical process with the Co being almost electrochemically inactive. Reversible Ni ions movement between TMs sites and Li sites is also revealed by the time-resolved QXAS technique.

25 ENERGY STORAGE↗

Ground electronic state description of thiourea coordination in homoleptic Zn 2+ , Ni 2+ and Co 2+ complexes using sulfur K -edge X-ray absorption spectroscopy

Sulfur K-edge X-ray absorption spectroscopy (XAS) was employed to experimentally characterize the coordinative bond between the thiourea (TU) or thiocarbamide ligand and transition metal (TM) ions Zn 2+ , Co 2+ and Ni 2+ in distorted tetrahedral and octahedral homoleptic coordination environments. Comparisons of XAS spectra of the free TU ligand and [Zn(TU) 4 ] 2+ , [Co(TU) 4 ] 2+ and [Ni(TU) 6 ] 2+ complexes clearly identify spectral features unique to TM 2+ –S(TU) bonding. Quantitative analysis of pre-edge intensities describes the covalency of Ni 2+ —S(TU) and Co 2+ —S(TU) bonding to be at most 21% and 9% as expressed by the S 3p contributions per TM 3d electron hole. Using relevant Ni 2+ complexes with dithiocarbamate and thioether ligands, we evaluated the empirical S 1s → 3p transition dipole integrals developed for S-donor ligands and their dependence on heteroatom substitutions. With the aid of density functional theory-based ground electronic state calculations, we found evidence for the need of using a transition dipole that is dependent on the presence of conjugated heteroatom (N) substitution in these S-donor ligands.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Source noise suppression in attosecond transient absorption spectroscopy by edge-pixel referencing

Attosecond transient absorption spectroscopy (ATAS) is used to observe photoexcited dynamics with outstanding time resolution. The main experimental challenge of this technique is that high-harmonic generation sources show significant instabilities, resulting in sub-par sensitivity when compared to other techniques. This paper proposes edge-pixel referencing as a means to suppress this noise. Two approaches are introduced: the first is deterministic and uses a correlation analysis, while the second relies on singular value decomposition. Each method is demonstrated and quantified on a noisy measurement taken on WS 2 and results in a fivefold increase in sensitivity. The combination of the two methods ensures the fidelity of the procedure and can be implemented on live data collection but also on existing datasets. The results show that edge-referencing methods bring the sensitivity of ATAS near the detector noise floor. An implementation of the post-processing code is provided to the reader.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Insight into the Chemistry of PETN Under Shock Compression Through Ultrafast Broadband Mid-Infrared Absorption Spectroscopy

In this study, thin films of pentaerythritol tetranitrate (PETN) were shock compressed using the laser driven shock apparatus at Los Alamos National Laboratory (LANL). Two spectroscopic probes were available to this apparatus: visible white light transient absorption spectroscopy (VIS) from 400 to 700 nm and mid-infrared transient absorption spectroscopy (MIR) from 1150 to 3800 cm –1 . Important PETN vibrational modes are the symmetric and antisymmetric NO 2 stretches at 1280 and 1650 cm –1 , respectively, as well as CH stretches at ~2900 cm –1 . Shock strength was varied from approximately 3 to 55 GPa to span from the chemically unreactive regime to the regime in which fast chemical reaction took place on the 250 ps time scale of the measurements. VIS and MIR results suggest irreversible chemistry was induced in PETN at pressures above 30 GPa. At lower shock pressures, the spectroscopy showed minimal changes attributable to pressure induced effects. Under the higher-pressure reactive conditions, the frequency region at the antisymmetric NO 2 stretch mode had a significantly increased absorption while the region around the symmetric NO 2 stretch did not. No observable increased absorption occurred in the higher frequency regions where CH-, NH-, and OH- bond absorptions would be observed. A broad absorption appeared on the shoulder at the red-edge of the CO 2 vibrational band around 2200 cm –1 . In addition to the experiments, reactive molecular dynamics were carried out under equivalent shock conditions to correlate the evolution of the infrared spectrum to molecular processes. The simulations show results consistent to experiments up to 30 GPa but suggest that NO and NO 2 related features provided the strongest contributions to the shocked infrared changes. Proposed mechanisms for shocked PETN chemistry are analyzed as consistent or inconsistent with the data presented here. Our experimental data suggests C≡O or N 2 O bond formation, nitrite formation, and absence of significant hydroxyl or amine concentrations in the initial chemistry steps in PETN shocked above 30 GPa.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-resolved x-ray absorption spectroscopy probe in ultrafast surface chemistry

To celebrate the scientific achievement of Jo Stöhr, I present here a personal account of the use of x-ray absorption spectroscopy to probe dynamics on surfaces using x-ray lasers. In particular, I will review the investigation of ultrafast processes in adsorbates on surfaces using an optical pump and an x-ray absorption spectroscopy probe. Here, it is shown that it is possible to gain insight into the effects of electronic excitations in metals on adsorbates as well as laser-induced vibrational motions. Furthermore, the ultrafast optical pump allows the detection of the CO precursor state in the desorption channel, species close to the transition state in CO oxidation, and the transient HCO intermediate during CO hydrogenation on Ru(0001).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bridging the Gap between the X-ray Absorption Spectroscopy and the Computational Catalysis Communities in Heterogeneous Catalysis: A Perspective on the Current and Future Research Directions

X-ray absorption spectroscopy (XAS) [extended X-ray absorption fine structure (EXAFS) and X-ray absorption near-edge structure (XANES)] is a key technique within the heterogeneous catalysis community to probe the structure and properties of the active site(s) for a diverse range of catalytic materials. Furthermore, the interpretation of the raw experimental data to derive an atomistic picture of the catalyst requires modeling and analysis; the EXAFS data are compared to a model, and a goodness of fit parameter is used to judge the best fit. This EXAFS modeling can often be nontrivial and time-consuming; overcoming or improving these limitations remains a central challenge for the community. Considering these limitations, this Perspective highlights how recent developments in analysis software, increased availability of reliable computational models, and application of data science tools can be used to improve the speed, accuracy, and reliability of EXAFS interpretation. In particular, we emphasize the advantages of combining theory and EXAFS as a unified technique that should be treated as a standard (when applicable) to identify catalytic sites and not two separate complementary methods. Building on the recent trends in the computational catalysis community, we also present a community-driven approach to adopt FAIR Guiding Principles for the collection, analysis, dissemination, and storage of XAS data. Written with both the experimental and theory audience in mind, we provide a unified roadmap to foster collaborations between the two communities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗