Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

SLAC All Access: Vacuum Microwave Device Department

The Vacuum Microwave Device Department (VMDD) builds the devices that make SLAC's particle accelerators go. These devices, called klystrons, generate intense waves of microwave energy that rocket subatomic particles up to nearly the speed of light.

43 PARTICLE ACCELERATORS↗

Instrumentation for localized superconducting cavity diagnostics

Superconducting accelerator cavities are now routinely operated at levels approaching the theoretical limit of niobium. To achieve these operating levels more information than is available from the RF excitation signal is required to characterize and determine fixes for the sources of performance limitations. This information is obtained using diagnostic techniques which complement the analysis of the RF signal. In this paper we describe the operation and select results from three of these diagnostic techniques: the use of large scale thermometer arrays, second sound wave defect location and high precision cavity imaging with the Kyoto camera.

43 PARTICLE ACCELERATORS↗

Instrument Records And Plays Back Acceleration Signals

Small, battery-powered, hand-held instrument feeds power to accelerometer and records time-varying component of output for 15 seconds in analog form. No power needed to maintain content of memory; memory chip removed after recording and stored indefinitely. Recorded signal plays back at any time up to several years later. Principal advantages: compactness, portability, and low cost.

Bozeman, Richard J.↗

Miniature Ion-Mobility Spectrometer

The figure depicts a proposed miniature ion-mobility spectrometer that would be fabricated by micromachining. Unlike prior ion-mobility spectrometers, the proposed instrument would not be based on a time-of-flight principle and, consequently, would not have some of the disadvantageous characteristics of prior time-of-flight ion-mobility spectrometers. For example, one of these characteristics is the need for a bulky carrier-gas-feeding subsystem that includes a shutter gate to provide short pulses of gas in order to generate short pulses of ions. For another example, there is need for a complex device to generate pulses of ions from the pulses of gas and the device is capable of ionizing only a fraction of the incoming gas molecules; these characteristics preclude miniaturization. In contrast, the proposed instrument would not require a carrier-gas-feeding subsystem and would include a simple, highly compact device that would ionize all the molecules passing through it. The ionization device in the proposed instrument would be a 0.1-micron-thick dielectric membrane with metal electrodes on both sides. Small conical holes would be micromachined through the membrane and electrodes. An electric potential of the order of a volt applied between the membrane electrodes would give rise to an electric field of the order of several megavolts per meter in the submicron gap between the electrodes. An electric field of this magnitude would be sufficient to ionize all the molecules that enter the holes. Ionization (but not avalanche arcing) would occur because the distance between the ionizing electrodes would be less than the mean free path of gas molecules at the operating pressure of instrument. An accelerating grid would be located inside the instrument, downstream from the ionizing membrane. The electric potential applied to this grid would be negative relative to the potential on the inside electrode of the ionizing membrane and would be of a magnitude sufficient to generate a moderate electric field. Positive ions leaving the membrane holes would be accelerated in this electric field. The resulting flux of ions away from the ionization membrane would create a partial vacuum that would draw more of the gas medium through the membrane. The figure depicts a filter electrode and detector electrodes located along the sides of a drift tube downstream from the accelerator electrode. These electrodes would apply a transverse AC electric field superimposed on a ramped DC electric field. The AC field would effect differential transverse dispersal of ions. At a given instant of time, the trajectories of most of the ions would be bent toward the electrodes, causing most of the ions to collide with the electrodes and thereby become neutralized. The DC field would partly counteract the dispersive effect of the AC field, straightening the trajectories of a selected species of ions; the selection would vary with the magnitude of the applied DC field. The straightening of the trajectories of the selected ions would enable them to pass into the region between the detector electrodes. Depending on the polarity of the voltage applied to the detector electrodes, the electric field between the detector electrodes would draw the selected ions to one of these electrodes. Hence, the current collected by one of the detector electrodes would be a measure of the abundance of ions of the selected species. The ramping of the filter- electrode DC voltage would sweep the selection of ions through the spectrum of ionic species.

Hartley, Frank T.↗

SNOWMASS2021 (AF7): Sub-scale models and infrastructure for accelerator magnet development

The LHC is undoubtfully the most important instrument the HEP community has on its disposal and is widely considered an amazing technological achievement. At the core of this instrument lay accelerator magnets based on NbTi technology – a technology well developed and widely used in the commercial sector too. Yet, a decade after the accelerator started it still did not reach its design collision energy of 14 TeV and it operated for years well below it. The reason for this is simple – magnet training (even though only a subset of the magnets is mostly affected).

43 PARTICLE ACCELERATORS↗

Numerical modeling of a proton spin-flipping system in the spin transparency mode at an integer spin resonance in JINR's Nuclotron

In this paper we propose a lattice insertion for the Nuclotron ring called a “spin navigator” that can adjust any direction of the proton polarization in the orbital plane using weak solenoids. The polarization control is realized in the spin transparency mode at the energy of 108 MeV, which corresponds to the integer spin resonance γ G = 2. The requirements on the navigator solenoid fields are specified considering the criteria for stability of the spin motion during any manipulation of the polarization direction in an experiment. Additionally, this paper presents the results of numerical modeling of the proton spin dynamics in the Nuclotron ring operated in the spin transparency mode. The verified spin navigator is aimed at an experimental study of a spin-flipping system using the Nuclotron ring. The results are relevant to the NICA (JINR), EIC (BNL) and COSY (FZJ) facilities where the spin transparency mode can be applied for polarization control.

47 OTHER INSTRUMENTATION↗

Instrument automatically selects peak acceleration signal from several accelerometers

Solid state circuit selects the highest of several ac accelerometer signals and gates this signal to an output amplifier, preserving all the frequency information in the peak signal. If the amplitudes of the accelerometer signals change with time, the circuit will continually switch to the highest signal, rejecting the smaller signals.

Chapman, C. P.↗

OARE and SAMS on STS-94/MSL-1

Four microgravity acceleration measurement instruments were included on MSL-1 to measure the accelerations and vibrations to which science experiments were exposed during their operation on the mission. The data were processed and presented to the principal investigators in a variety of formats to aid their assessment of the microgravity environment during their experiment operations. Two accelerometer systems managed by the NASA Lewis Research Center (LeRC) supported the MSL-1 mission: the Orbital Acceleration Research Experiment (OARE), and the Space Acceleration Measurement System (SAMS). In addition, the Microgravity Measurement Assembly (MMA) and the Quasi- Steady Acceleration Measurement (QSAM) system, both sponsored by the Microgravity Research Division, collected acceleration data as a part of the MSL-1 mission. The NIMA was funded and designed by the European Space Agency in the Netherlands (ESA/ESTEC), and the QSAM system was funded and designed by the German Space Agency (DLR). The Principal Investigator Microgravity Services (PIMS) project at the NASA Lewis Research Center (LeRC) supports Principal Investigators (PIs) of the Microgravity science community as they evaluate the effects of acceleration on their experiments. PIMS primary responsibility is to support NASA-sponsored investigators in the area of acceleration data analysis and interpretation. A mission summary report was prepared and published by PIMS in order to furnish interested experiment investigators with a guide for evaluating the acceleration environment during the MSL-1 mission.

Moskowitz, Milton↗

Demonstration of a real-time interferometer as a bunch-length monitor in a high-current electron beam accelerator

A real-time interferometer (RTI) has been developed to monitor the bunch length of an electron beam in an accelerator. The RTI employs spatial autocorrelation, reflective optics, and a fast response pyro-detector array to obtain a real-time autocorrelation trace of the coherent radiation from an electron beam thus providing the possibility of online bunch-length diagnostics. A complete RTI system has been commissioned at the A0 photoinjector facility to measure sub-mm bunches at 13 MeV. Bunch length variation (FWHM) between 0.8 ps ({approx}0.24 mm) and 1.5 ps ({approx}0.45 mm) has been measured and compared with a Martin-Puplett interferometer and a streak camera. The comparisons show that RTI is a viable, complementary bunch length diagnostic for sub-mm electron bunches.

43 PARTICLE ACCELERATORS↗

Suppression of Longitudinal Coupled-Bunch Instabilities at the KEK-PF

A bunch-by-bunch feedback system has been developed to suppress longitudinal coupled-bunch instabilities at the KEK-PF. A longitudinal kicker based on a DAFNE-type overdamped cavity has been designed and installed in the ring, and a general purpose signal processor, called iGp, has been developed by the collaboration of the KEK, SLAC, and INFN-LNF. The entire feedback loop has been closed by the end of June 2007, and the feedback system has successfully suppressed the longitudinal dipole-mode instabilities up to 430 mA.

43 PARTICLE ACCELERATORS↗

Space experiments with particle accelerators: SEPAC

The SEPAC instruments consist of an electron accelerator, a plasma accelerator, a neutral gas (N2) release device, particle and field diagnostic instruments, and a low light level television system. These instruments are used to accomplish multiple experiments: to study beam-particle interactions and other plasma processes; as probes to investigate magnetospheric processes; and as perturbation devices to study energy coupling mechanisms in the magnetosphere, ionosphere, and upper atmosphere.

Roberts, B.↗

Update of Earthquake Strong-Motion Instrumentation at Lawrence Livermore National Laboratory

Following the January 1980 earthquake that was felt at Lawrence Livermore National Laboratory (LLNL), a network of strong-motion accelerographs was installed at LLNL. Prior to the 1980 earthquake, there were no accelerographs installed. The ground motion from the 1980 earthquake was estimated from USGS instruments around the Laboratory to be between 0.2 – 0.3 g horizontal peak ground acceleration. These instruments were located at the Veterans Hospital, 5 miles southwest of LLNL, and in San Ramon, about 12 miles west of LLNL. In 2011, the Department of Energy (DOE) requested to know the status of our seismic instruments. We conducted a survey of our instrumentation systems and responded to DOE in a letter. During this survey, it was found that the recorders in Buildings 111 and 332 were not operational. The instruments on Nova had been removed, and only three of the 10 NIF instruments installed in 2005 were operational (two were damaged and five had been removed from operation at the request of the program). After the survey, it was clear that the site seismic instrumentation had degraded substantially and would benefit from an overhaul and more attention to ongoing maintenance. LLNL management decided to update the LLNL seismic instrumentation system. The updated system is documented in this report.

42 ENGINEERING↗

The Linac Extension Area at the Advanced Photon Source

The Linac Extension Area has been developed into a beamline area for testing accelerator components and techniques. Beginning commissioning activities in February 2023, we have delivered the first electron beam to the Linac Extension Area at the Advanced Photon Source at 425 MeV. In the present work, we summarise the principal accelerator components and review safety controls of the Linac Extension Area.

47 OTHER INSTRUMENTATION↗

Software Architecture for Next Generation Beam Position Monitors at Fermilab

The Fermilab Accelerator Division / Instrumentation Department develops Beam Position Monitor (BPM) systems in-house to support its sprawling accelerator complex. Two new BPM systems have been deployed and another upgraded over the last two years. These systems are based on a combination of VME and Gigabit Ethernet connected hardware and a common Linux-based embedded software platform with modular components. The architecture of this software platform and the considerations for adapting to future machines or upgrade projects will be described.

43 PARTICLE ACCELERATORS↗

Feasibility of miniaturized instrumentation of the inflatable sphere for temperature, pressure and acceleration measurement

The feasibility of instrumenting the inflatable passive sphere (presently used to provide upper atmosphere density measurements) with miniaturized thermistors, pressure transducers, and accelerometers was analyzed. Data from the sensors must be transmitted by an onboard telemetry system to a ground receiving station. To assure a sufficiently slow fall velocity for the sphere the additional mass of the sensor and telemetry hardware must be less than 100 grams. Other constraints that must be satisfied by the sensor and telemetry systems include the ability to withstand a 150 g launch acceleration, the ability to function in both high and low temperature and pressure environments and be sufficiently small to be packaged within the body of a 3.81 cm diameter dart. A differential transducer that will measure the difference between ambient and internal sphere pressures is recommended. The application of each type of measurement relative to its ability to monitor sphere malfunction and to provide additional meteorological data is considered.

Luers, J. K.↗

Beam Diagnostics for FACET

FACET, the Facility for Advanced Accelerator and Experimental Tests, is a new facility being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration beginning in summer 2011. The nominal FACET parameters are 23GeV, 3nC electron bunches compressed to about 20 {micro}m long and focussed to about 10 {micro}m wide. Characterization of the beam-plasma interaction requires complete knowledge of the incoming beam parameters on a pulse-to-pulse basis. FACET diagnostics include Beam Position Monitors, Toroidal current monitors, X-ray and Cerenkov based energy spectrometers, optical transition radiation (OTR) profile monitors and coherent transition radiation (CTR) bunch length measurement systems. The compliment of beam diagnostics and their expected performance are reviewed. Beam diagnostic measurements not only provide valuable insights to the running and tuning of the accelerator but also are crucial for the PWFA experiments in particular. Beam diagnostic devices are being set up at FACET and will be ready for beam commissioning in summer 2011.

43 PARTICLE ACCELERATORS↗

Reactor design and integration with product detection to accelerate screening of electrocatalysts for carbon dioxide reduction

Identifying new catalyst materials for complex reactions such as the electrochemical reduction of CO 2 poses substantial instrumentation challenges due to the need to integrate reactor control with electrochemical and analytical instrumentation. Performing accelerated screening to enable exploration of a broad span of catalyst materials poses additional challenges due to the long time scales associated with accumulation of reaction products and the detection of the reaction products with traditional separation-based analytical methods. The catalyst screening techniques that have been reported for combinatorial studies of (photo)electrocatalysts do not meet the needs of CO 2 reduction catalyst research, prompting our development of a new electrochemical cell design and its integration to gas and liquid chromatography instruments. To enable rapid chromatography measurements while maintaining sensitivity to minor products, the electrochemical cell features low electrolyte and head space volumes compared to the catalyst surface area. Additionally, the cell is operated as a batch reactor with electrolyte recirculation to rapidly concentrate reaction products, which serves the present needs for rapidly detecting minor products and has additional implications for enabling product separations in industrial CO 2 electrolysis systems. To maintain near-saturation of CO 2 in aqueous electrolytes, we employ electrolyte nebulization through a CO 2 -rich headspace, achieving similar gas-liquid equilibration as vigorous CO 2 bubbling but without gas flow. The instrument is demonstrated with a series of electrochemical experiments on an Au-Pd combinatorial library, revealing non-monotonic variations in product distribution with respect to catalyst composition. The highly integrated analytical electrochemistry system is engineered to enable automation for rapid catalyst screening as well as deployment for a broad range of electrochemical reactions where product distribution is critical to the assessment of catalyst performance.

47 OTHER INSTRUMENTATION↗