Uncertainty Analysis and Software Verification

Uncertainty analyses are an important part of calibrations and testing. They allow researchers insight on how to reduce and mitigate errors in testing. Each device used in testing introduces error in a system, as well as other sources such as environmental conditions, electronics, analog to digital, and random errors. Each source is carefully examined to identify how much error it introduces to a system. These sources are then combined using various methods of uncertainty calculations. To verify and validate software, a manual calculation is required to ensure the software is performing as intended. Using Excel to verify the calculations, we can identify discrepancies within the software. The root of the sum of the squares uncertainty (RSS) is used to find the combined uncertainty of a device at one and two standard deviations of the mean. Calibrations on accelerometers are performed using a vibration system along with a back-toback reference accelerometer. The vibration system takes a reference point at 100Hz frequency at 10g amplitude. The sensitivities are collected at each dialed in frequency. The sensitivity of the device represents the electrical output of the UUT (mV, pC, etc.) per unit of acceleration (g). The full history of sensitivities of selected accelerometers are used to find the averaged, standard deviation, and uncertainty of the device at each frequency tested. The uncertainty calculations from excel and the software are then compared.

97 MATHEMATICS AND COMPUTING↗

Data Release Report for the Source Physics Experiment Phase II: Dry Alluvium Geology Experiments (DAG-1 through DAG-4), Nevada National Security Site

The Dry Alluvium Geology (DAG) project was Phase II of the Source Physics Experiment and consisted of a series of four chemical explosive tests conducted in the same source hole on the Nevada National Security Site. This hole is located at 37.1146°N and -116.0693°W, with a surface elevation of 1,285.2 meters (m) (4,216.5 feet [ft]) above sea level. The first test (DAG-1) was conducted on July 20, 2018, at 16:51:52.67838 Coordinated Universal Time (UTC). The explosive source for DAG-1 was nitromethane initiated by a small plastic-bonded explosive (PBX) charge, detonated at the depth of 385.0 m (1,263.2 ft) below ground surface. DAG-1 had a trinitrotoluene (TNT) equivalent yield of 0.908 metric tons (2,002 pounds [lbs]). DAG-2 was conducted on December 19, 2018, at 18:45:56.92115 UTC. This test was the largest in the series, with a TNT equivalent yield of 50.997 metric tons (112,429 lbs). The explosive source for DAG-2 was nitromethane initiated by a small PBX charge, detonated at the depth of 299.8 m (983.6 ft) below ground surface. DAG-3 was conducted on April 27, 2019, at 15:49:01.84183 UTC. The explosive source for this test was nitromethane initiated by a small PBX charge, detonated at the depth of 149.9 m (492.0 ft) below ground surface. DAG-3 had a TNT equivalent yield of 0.908 metric tons (2,002 lbs). The final DAG test (DAG-4) was conducted on June 22, 2019, at 21:06:19.87632 UTC. The explosive source for DAG-4 was nitromethane initiated by a small PBX charge, detonated at the depth of 51.6 m (169.3 ft) below ground surface. DAG-4 had a TNT equivalent yield of 10.357 metric tons (22,833 lbs). The four tests were recorded by an extensive set of instrumentation that included sensors both at near-field (less than 200 m) and far-field (200 m or greater) distances. The near-field instruments consisted of three-component (3C) accelerometers installed at various depths ranging from 51.6 to 385 m (169.3 to 1,263.1 ft) below ground surface in boreholes positioned around the source hole, and arrays of single-component and 3C accelerometers on the surface. The far-field network comprised a variety of seismic and acoustic sensors, including short-period geophones, broadband seismometers, and 3C accelerometers at distances of 200 m to 400 kilometers. In addition, the DAG-2, DAG-3, and DAG-4 explosions were recorded by a temporary array of 496 geophones arranged in a densely spaced grid pattern known as “Large N.” This report coincides with the release of these data for analysts and organizations that are not participants in this program. This report describes the four DAG tests and the various types of near-field, far-field, and other data that are available. Assembled data sets are accessible through: Incorporated Research Institutions for Seismology, Data Management Center 1408 NE 45th Street, Suite 201, Seattle, Washington 98105 USA. www.iris.washington.edu

58 GEOSCIENCES↗

EGS Collab Experiment 2: Continuous Active Source Seismic Monitoring (CASSM)

The dataset contains continuous active-source seismic monitoring (CASSM) data collected during EGS Collab Experiment 2, conducted from February to September 2022 at the Sanford Underground Research Facility in Lead, South Dakota. This experiment aimed to investigate enhanced geothermal systems through high-pressure fluid injections at depths of 1200-1500 meters. The seismic monitoring system included 16 three-component piezoelectric accelerometers and 24 hydrophones installed in boreholes around the injection zones, recording signals from piezoelectric seismic sources. Data were acquired using both continuous and triggered recording systems, with sampling rates of up to 100 kHz. The raw data are organized by timestamps and stored in .dat format, with accompanying log files. Calibration certificates for selected accelerometers are provided to aid in correcting sensor responses, though users are advised to consider possible effects of enclosures and installation on sensor performance. Users are strongly advised to consult the accompanying report, which outlines the experimental setup, data acquisition, sensor specifications, and recording systems.

15 GEOTHERMAL ENERGY↗

Low-Power, Flexible Sensor Arrays with Solderless Board-to-Board Connectors for Monitoring Soil Deformation and Temperature

Landslides are a global and frequent natural hazard, affecting many communities and infrastructure networks. Technological solutions are needed for long-term, large-scale condition monitoring of infrastructure earthworks or natural slopes. However, current instruments for slope stability monitoring are often costly, require a complex installation process and/or data processing schemes, or have poor resolution. Wireless sensor networks comprising low-power, low-cost sensors have been shown to be a crucial part of landslide early warning systems. Here, we present the development of a novel sensing approach that uses linear arrays of three-axis accelerometers for monitoring changes in sensor inclination, and thus the surrounding soil’s deformation. By combining these deformation measurements with depth-resolved temperature measurements, we can link our data to subsurface thermal–hydrological regimes where relevant. In this research, we present a configuration of cascaded I2C sensors that (i) have ultra-low power consumption and (ii) enable an adjustable probe length. From an electromechanical perspective, we developed a novel board-to-board connection method that enables narrow, semi-flexible sensor arrays and a streamlined assembly process. The low-cost connection method relies on a specific FR4 printed circuit board design that allows board-to-board press fitting without using electromechanical components or solder connections. The sensor assembly is placed in a thin, semi-flexible tube (inner diameter 6.35 mm) that is filled with an epoxy compound. The resulting sensor probe is connected to an AA-battery-powered data logger with wireless connectivity. We characterize the system’s electromechanical properties and investigate the accuracy of deformation measurements. Our experiments, performed with probes up to 1.8 m long, demonstrate long-term connector stability, as well as probe mechanical flexibility. Furthermore, our accuracy analysis indicates that deformation measurements can be performed with a 0.390 mm resolution and a 95% confidence interval of ±0.73 mm per meter of probe length. This research shows the suitability of low-cost accelerometer arrays for distributed soil stability monitoring. In comparison with emerging low-cost measurements of surface displacement, our approach provides depth-resolved deformation, which can inform about shallow sliding surfaces.

deformation monitoring↗

Robust and optimal alignment of high-dimensional data using maximum likelihood estimation through a random sample consensus framework

Abstract Correcting spatial orientations of groups of high-dimensional data sets such that they are all in a consistent coordinate system is often a time-consuming and error-prone process. Automation of this process can be accomplished by using Generalized Procrustes Analysis to estimate the relative orientations among a population of high-dimensional data sets. A least squares Procrustes solution is applied through a maximum likelihood estimation and random sample consensus framework for robustness. The likelihood model is comprised of a mixture distribution where inliers are modeled using t -distribution and outliers from a uniform distribution. Applications will focus on a synthetic data set that emulates triaxial acceleration data and also real shock data from a population of triaxial accelerometers. Outliers represent either non-rigid body responses, environmental noise, and/or sensor and data acquisition issues. The intended application for the methodology is to robustly automate the rotation of populations of experimentally collected triaxial accelerometer data sets to a single global coordinate system.

LOSAC↗

Structural response reconstruction using a system-equivalent singular vector basis

Here, this paper develops a novel method for reconstructing the full-field response of structural dynamic systems using sparse measurements. The singular value decomposition is applied to a frequency response matrix relating the structural response to physical loads, base motion, or modal loads. The left singular vectors form a non-physical reduced basis that can be used for response reconstruction with far fewer sensors than existing methods. The contributions of the singular vectors to measured response are termed singular-vector loads (SVLs) and are used in a regularized Bayesian framework to generate full-field response estimates and confidence intervals. The reconstruction framework is applicable to the estimation of single data records and power spectral densities from multiple records. Reconstruction is successfully performed in configurations where the number of SVLs to identify is less than, equal to, and greater than the number of sensors used for reconstruction. In a simulation featuring a seismically excited shear structure, SVL reconstruction significantly outperforms modal FRF-based reconstruction and successfully estimates full-field responses with as few as two uniaxial accelerometers. SVL reconstruction is further verified in a simulation featuring an acoustically excited cylinder. Finally, response reconstruction and uncertainty quantification are performed on an experimental structure with three shaker inputs and 27 triaxial accelerometer outputs.

42 ENGINEERING↗

Comparison of sleep parameters from wrist-worn ActiGraph and Actiwatch devices

Abstract Sleep and physical activity, two important health behaviors, are often studied independently using different accelerometer types and body locations. Understanding whether accelerometers designed for monitoring each behavior can provide similar sleep parameter estimates may help determine whether one device can be used to measure both behaviors. Three hundred and thirty one adults (70.7 ± 13.7 years) from the Baltimore Longitudinal Study of Aging wore the ActiGraph GT9X Link and the Actiwatch 2 simultaneously on the non-dominant wrist for 7.0 ± 1.6 nights. Total sleep time (TST), wake after sleep onset (WASO), sleep efficiency, number of wake bouts, mean wake bout length, and sleep fragmentation index (SFI) were extracted from ActiGraph using the Cole–Kripke algorithm and from Actiwatch using the software default algorithm. These parameters were compared using paired t-tests, Bland–Altman plots, and Deming regression models. Stratified analyses were performed by age, sex, and body mass index (BMI). Compared to the Actiwatch, the ActiGraph estimated comparable TST and sleep efficiency, but fewer wake bouts, longer WASO, longer wake bout length, and higher SFI (all p < .001). Both devices estimated similar 1-min and 1% differences between participants for TST and SFI (β = 0.99, 95% CI: 0.95, 1.03, and 0.91, 1.13, respectively), but not for other parameters. These differences varied by age, sex, and/or BMI. The ActiGraph and the Actiwatch provide comparable absolute and relative estimates of TST, but not other parameters. The discrepancies could result from device differences in movement collection and/or sleep scoring algorithms. Further comparison and calibration is required before these devices can be used interchangeably.

Liu, Fangyu (ORCID:0000000315541478)↗

Fast estimation of the look-elsewhere effect using Gaussian random fields

Abstract We discuss the use of Gaussian random fields to estimate the look-elsewhere effect correction. We show that Gaussian random fields can be used to model the null-hypothesis significance maps from a large set of statistical problems commonly encountered in physics, such as template matching and likelihood ratio tests. Some specific examples are searches for dark matter using pixel arrays, searches for astronomical transients, and searches for fast-radio bursts. Gaussian random fields can be sampled efficiently in the frequency domain, and the excursion probability can be fitted with these samples to extend any estimation of the look-elsewhere effect to lower p values. In addition, in cases where the Gaussian random field is stationary and the parameter space is Euclidean, the look-elsewhere effect correction can be computed analytically. We demonstrate these methods using two example template matching problems. Finally, we apply these methods to estimate the trial factor of a $$4^3$$ 4 3 accelerometer array for the detection of dark matter tracks in the Windchime project. When a global significance of $$3\sigma $$ 3 σ is required, the estimated trial factor for such an accelerometer array is $$10^{14}$$ 10 14 for a one-second search, and $$10^{22}$$ 10 22 for a 1-year search.

Qin, Juehang (ORCID:0000000182288949)↗

Criterion validity of wrist accelerometry for assessing energy intake via the intake-balance technique

Background: Intake-balance assessments measure energy intake (EI) by summing energy expenditure (EE) with concurrent change in energy storage (ΔES). Prior work has not examined the validity of such calculations when EE is estimated via open-source techniques for research-grade accelerometry devices. The purpose of this study was to test the criterion validity of accelerometry-based intake-balance methods for a wrist-worn ActiGraph device. Methods: Healthy adults (n = 24) completed two 14-day measurement periods while wearing an ActiGraph accelerometer on the non-dominant wrist. During each period, criterion values of EI were determined based on ΔES measured by dual X-ray absorptiometry and EE measured by doubly labeled water. A total of 11 prediction methods were tested, 8 derived from the accelerometer and 3 from non-accelerometry methods (e.g., diet recall; included for comparison). Group-level validity was assessed through mean bias, while individual-level validity was assessed through mean absolute error, mean absolute percentage error, and Bland–Altman analysis. Results: Mean bias for the three best accelerometry-based methods ranged from -167 to 124 kcal/day, versus -104 to 134 kcal/day for the non-accelerometry-based methods. The same three accelerometry-based methods had mean absolute error of 323–362 kcal/day and mean absolute percentage error of 18.1-19.3%, versus 353–464 kcal/day and 19.5-24.4% for the non-accelerometry-based methods. All 11 methods demonstrated systematic bias in the Bland–Altman analysis. Conclusions: Accelerometry-based intake-balance methods have promise for advancing EI assessment, but ongoing refinement is necessary. We provide an R package to facilitate implementation and refinement of accelerometry-based methods in future research (see paulhibbing.com/IntakeBalance).

60 APPLIED LIFE SCIENCES↗

Comprehensive Physical Activity Assessment During U.S. Army Basic Combat Training

Abstract Alemany, JA, Pierce, JR, Bornstein, DB, Grier, TL, Jones, BH, and Glover, SH. Comprehensive physical activity assessment during U.S. Army Basic Combat Training. J Strength Cond Res 36(12): 3505–3512, 2022—Physical activity (PA) volume, intensity, and qualitative contextual information regarding activity type and loads carried are limited during U.S. Army Basic Combat Training (BCT). The purpose of this study was to characterize daily (05:00–20:00 hours) PA during BCT using a comprehensive approach. During 2 10-week BCT cycles ( n = 40 trainees per cycle), pedometers, accelerometers, and direct observation were used to estimate daily step count, PA volume, and intensity. Physical activity intensity was categorized by metabolic equivalents (METs) such as “sedentary” (1–2 METs), “light” (2–3 METs), “moderate” (3–6 METs), or “vigorous” (≥6 METs). Daily PA data were analyzed longitudinally using linear mixed models, with significance set at p ≤ 0.05. The mean daily step count was 13,459 ± 4,376 steps, and the mean daily accelerometer-assessed PA volume and intensity were as follows: sedentary: 505 ± 98 minutes, light: 190 ± 78 minutes, moderate: 168 ± 51 minutes, and vigorous: 14 ± 14 minutes, with no differences between cycles for all measures ( p > 0.50). Cumulative time on feet (∼50%) and sitting (20–25%) accounted for most daily activity types during both cycles. Trainees, on average, carried between 3 and 9 kg, and ≥9 kg, for 60% and 10% of the monitored day, respectively. Basic Combat Training's physical demands are high, where trainees achieved 1.7 to 2.7 times greater daily ambulation and 6 times the recommended weekly moderate-to-vigorous PA compared with civilian counterparts and performed weight-bearing load carriage for nearly half of the day. Basic Combat Training-associated PA may increase injury risk among trainees unaccustomed to arduous PA and exercise. Implementing national PA policies to improve physical fitness and facilitate acclimatization to BCT's high physical demands could reduce public health burdens and military nonreadiness.

Sport Sciences↗

Ganged-PV System Evaluation

The following report contains data and data summaries collected for the SkySun LLC elevated Ganged PV arrays. These arrays were fabricated as a series of PV panels in various orientations, suspended by cables, at the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (SNL). Starting in February of 2021, Sandia personnel have collected power and accelerometer data for these arrays to assess design and operational efficacy of varying ganged- PV configurations. The purpose of this power data collection was to see how the various array orientations compare in power collection capability depending on the time of day, year, and the specific daily solar direct normal irradiance (DNI). The power data was collected as a measurement of the power output from the various series strings. The project team measured direct current (DC) voltage and current from the respective arrays. The accelerometer data was collected with the purpose of demonstrating potential destructive mode shapes that could take place with each of the arrays when exposed to high winds. This allowed the team to evaluate whether impacts with respect to specific array orientations using suspended cables is a safe design. All data collection was performed during calendar year 2021.

14 SOLAR ENERGY↗

Low-cost sensors and analytics for a digital factory

ORNL Manufacturing Demonstration Facility and Perisense worked on a low-cost solution for machining process monitoring to enable a digital factory. Enabling machine connectivity for digital factors is expensive for many small to medium manufacturers. The hypothesis for the research project is that a lowcost sensor suite, which can be retrofitted to a legacy machine tool or a new machine tool, can effectively provide real-time, in-situ sensing for manufacturing processes, which can enable improvements in process performance and efficiency. The Perisense sensor node was installed on the Haas TM1 machine with a current sensor and an accelerometer. Cutting tests were performed at different process parameters and sensor data was recorded. Results show a correlation of the current sensor to the spindle load. The accelerometer, mounted on the machine base, showed a correlation to the spindle speed as well as the spindle load. The sensor data can be used to monitor the machining process and provide insights on the machine spindle load utilization.

42 ENGINEERING↗

US HL-LHC Accelerator Upgrade Project: MQXFA11 shipping incident report

The truck transporting the MQXFA11 magnet from LBNL to BNL was involved in an accident on 7/20/22. It was rear ended by another truck. Drivers were not injured. The main hit took place on the right back corner. The truck with the MQXFA11 magnet was towed to a tow yard in Rockdale, IL (~50 min drive from Fermilab). Subsequently, it was moved on another truck and moved to Fermilab. Fermilab employees added 3 accelerometers on the crate before it was moved on the new truck and attended all loading/unloading operations at the tow yard and at FNAL. The magnet arrived at FNAL on July 28 th . Upon arrival a visual inspection was performed. Accelerometers were removed and shock data were analyzed. Electrical checkout and a metrology survey were carried out. Strain data were also collected from the fiber optics installed on two coils and compared with data obtained before shipment. This report presents a summary of results. More pictures and details can be found at: https://indico.fnal.gov/event/55698/

43 PARTICLE ACCELERATORS↗

Shooter Alarm System Final Report FY23

Lawrence Livermore National Laboratory (LLNL) is developing a multiphysics sensor package for automatic live arms fire detection for use in schools, houses of worship, hospi tals, etc. The goal is to have a package the size of a common smoke or CO2 detector with a price point of $50 or less which may be deployed throughout the aforementioned facilities. The commercial device will detect live gun fire with low probability of false alarm and auto matically alert first responders. A prototype board with four accelerometers, two infrared (IR) and two microphones has been developed and deployed at two experiments at LLNL’s Small Firearms Training Facility (SFTF). The device successfully and consistently measured signals on the accelerometer and acoustic channels. IR responses were measured depending upon the environment and sound source.

42 ENGINEERING↗

Extraction of Vibration Data with Imaging

To date, the primary sensing technology used to measure the vibration response has been accelerometers and strain gages mounted directly to the structure and using either wired or, more recently, wireless telemetry. Cost issues with these sensors and the associated data acquisition systems typically limit the numbers that are deployed on in situ structures. Although there are a few structures with larger sensing counts that in some cases exceed over 1000 sensors, more typical numbers range from ten to one hundred sensors resulting in low spatial resolution when they are applied to physically large systems. When one considers that nuclear power plant structures usually have complex geometries, material properties, connectivity and boundary conditions, it is clear these current approaches to vibration measurements can only provide limited information about a system’s dynamics response characteristics. As an alternative, many non-contact measurement technologies have emerged, including point wise measurement methods such as Global Positioning System (GPS), microwave interferometry, and laser Doppler vibrometry (LDV), as well as simultaneous full-field measurement methods such as electronic speckle pattern interferometry, holography interferometry, and muon tomography, some of which can provide high spatial resolution measurements. Among these methods, digital video imaging techniques have emerged as a feasible solution for full-field vibration measurements that provide significantly more detailed dynamic response information because every pixel becomes a measurement point. Furthermore, recent advances in image processing and computer vision algorithms have been successfully used to process video data for experimental and operational modal analysis. Such full-field measurements have the potential to significantly improve many current structural assessment procedures including system identification (modal parameter estimation), structural health monitoring, load reconstruction, model validation, and model updating. Furthermore, more recent full-field imaging techniques can be accomplished with relatively low-cost, commercially-available off-the-shelf cameras. However, these measurement procedures have other limitations that must be considered such as the ability to only measure visibly accessible points on a structure and a more limited dynamic range and bandwidth than can be achieved with accelerometers or strain gages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Earth-Centered, Earth-Fixed Inertial Navigation System & Error-State Kalman Filter Reference Manual

This is a self-contained reference document that derives the equations necessary to build a combined inertial navigation system and error-state Kalman filter. Coordinate transform, linear time invariant system, inertial sensing, and error-state Kalman filtering theory is built up from first principles. This theory is then leveraged to derive the system equations for two combined inertial navigation system and error-state Kalman filters: (1) a 15-state system modeling white-noise-integrating accelerometer and gyroscope biases, and (2) a 39-state system modeling static and first-order Gauss-Markov accelerometer and gyroscope biases, scale factor errors, and cross-axis sensitivity errors.

42 ENGINEERING↗

Comparative Analysis of Explosion Signals on Smartphones and Seismometers [Poster]

Seismoacoustic signatures from a chemical explosion was recorded on two seismometers and eight smartphone accelerometers at Idaho National Laboratory (INL). The captured waveform’s propagation and its time frequency representations are compared. The smartphone accelerometers were able to pick up a clear seismoacoustic explosion signal at within 1 km (150 m/kg 1/3 ) and a noisy signal up to 5.3 km (790 m/kg 1/3 ).

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Experimental Investigation of Steel-Borne Acoustic Pulses for Fault Pinpointing in Pipe-Type Cable Systems: A Scaled-Down Model Approach

Pipe-type cable systems, including high-pressure fluid-filled (HPFF) and high-pressure gas-filled cables, are widely used for underground high-voltage transmission. These systems consist of insulated conductor cables within steel pipes, filled with pressurized fluids or gases for insulation and cooling. Despite their reliability, faults can occur due to insulation degradation, thermal expansion, and environmental factors. As many circuits exceed their 40-year design life, efficient fault localization becomes crucial. Fault location involves prelocation and pinpointing. Therefore, a novel pinpointing approach for pipe-type cable systems is proposed, utilizing accelerometers mounted on a steel pipe to capture fault-induced acoustic signals and employing the time difference of arrival method to accurately pinpoint the location of the fault. The experimental investigations utilized a scaled-down HPFF pipe-type cable system setup, featuring a carbon steel pipe, high-frequency accelerometers, and both mechanical and capacitive discharge methods for generating acoustic pulses. The tests evaluated the propagation velocity, attenuation, and pinpointing accuracy with the pipe in various embedment conditions. The experimental results demonstrated accurate fault pinpointing in the centimeter range, even when the pipe was fully embedded, with the acoustic pulse velocities aligning closely with the theoretical values. These experimental investigation findings highlight the potential of this novel acoustic pinpointing technique to improve fault localization in underground systems, enhance grid reliability, and reduce outage duration. Further research is recommended to validate this approach in full-scale systems.

Moutassem, Zaki↗