Capacitive Position Sensor For Accelerometer

Capacitive position sensor measures displacement of proof mass in prototype accelerometer described in "Single-Crystal Springs for Accelerometers" (NPO-18795). Sensor is ultrasensitive, miniature device operating at ultra-high frequency and described in more detail in "Ultra-High-Frequency Capacitive Displacement Sensor," (NPO-18675). Advances in design and fabrication of prototype accelerometer also applicable to magnetometers and other sensors in which sensed quantities measured in terms of deflections of small springs.

Vanzandt, Thomas R.↗

Single-Crystal Springs For Accelerometers

Thermal noise reduced, enabling use of smaller proof masses. Spring-and-mass accelerometers in which springs made of single-crystal material being developed. In spring-and-mass accelerometer, proof mass attached to one end of spring, and acceleration of object at other end of spring measured in terms of deflection of spring, provided frequency spectrum of acceleration lies well below resonant frequency of spring-and-proof-mass system. Use of single-crystal spring materials instead of such polycrystalline spring materials as ordinary metals makes possible to construct highly sensitive accelerometers (including seismometers) with small proof masses.

Vanzandt, Thomas R.↗

Accelerometer Method and Apparatus for Integral Display and Control Functions

Method and apparatus for detecting mechanical vibrations and outputting a signal in response thereto. Art accelerometer package having integral display and control functions is suitable for mounting upon the machinery to be monitored. Display circuitry provides signals to a bar graph display which may be used to monitor machine conditions over a period of time. Control switches may be set which correspond to elements in the bar graph to provide an alert if vibration signals increase in amplitude over a selected trip point. The circuitry is shock mounted within the accelerometer housing. The method provides for outputting a broadband analog accelerometer signal, integrating this signal to produce a velocity signal, integrating and calibrating the velocity signal before application to a display driver, and selecting a trip point at which a digitally compatible output signal is generated.

Bozeman, Richard J., Jr.↗

Accelerometer Data Analysis and Presentation Techniques

The NASA Lewis Research Center's Principal Investigator Microgravity Services project analyzes Orbital Acceleration Research Experiment and Space Acceleration Measurement System data for principal investigators of microgravity experiments. Principal investigators need a thorough understanding of data analysis techniques so that they can request appropriate analyses to best interpret accelerometer data. Accelerometer data sampling and filtering is introduced along with the related topics of resolution and aliasing. Specific information about the Orbital Acceleration Research Experiment and Space Acceleration Measurement System data sampling and filtering is given. Time domain data analysis techniques are discussed and example environment interpretations are made using plots of acceleration versus time, interval average acceleration versus time, interval root-mean-square acceleration versus time, trimmean acceleration versus time, quasi-steady three dimensional histograms, and prediction of quasi-steady levels at different locations. An introduction to Fourier transform theory and windowing is provided along with specific analysis techniques and data interpretations. The frequency domain analyses discussed are power spectral density versus frequency, cumulative root-mean-square acceleration versus frequency, root-mean-square acceleration versus frequency, one-third octave band root-mean-square acceleration versus frequency, and power spectral density versus frequency versus time (spectrogram). Instructions for accessing NASA Lewis Research Center accelerometer data and related information using the internet are provided.

Rogers, Melissa J. B.↗

Accelerometer Method and Apparatus for Integral Display and Control Functions

Method and apparatus for detecting mechanical vibrations and outputting a signal in response thereto is discussed. An accelerometer package having integral display and control functions is suitable for mounting upon the machinery to be monitored. Display circuitry provides signals to a bar graph display which may be used to monitor machine conditions over a period of time. Control switches may be set which correspond to elements in the bar graph to provide an alert if vibration signals increase in amplitude over a selected trip point. The circuitry is shock mounted within the accelerometer housing. The method provides for outputting a broadband analog accelerometer signal, integrating this signal to produce a velocity signal, integrating and calibrating the velocity signal before application to a display driver, and selecting a trip point at which a digitally compatible output signal is generated.

Bozeman, Richard J., Jr.↗

Terrestrial Applications of a Nano-g Accelerometer

The ultra-sensitive accelerometer, developed for NASA to monitor the microgravity environments of Space Shuttle, five orbiters and Space Station, needed to measure accelerations up to 10 mg with an absolute accuracy of 10 nano-g (10(exp -8)g) for at least two orbits (10(exp 4) seconds) to resolve accelerations associated with orbital drag. Also, the accelerometers needed to have less than 10(exp -9) F.S. off-axis sensitivity; to be thermally and magnetically inert; to be immune to quiescent shock, and to have an in-situ calibration capability. Multi-axis compact seismometers, designs that have twelve decades of dynamic range will be described. Density profilometers, precision gradiometers, gyros and vibration isolation designs and applications will be discussed. Finally, examples of transformations of the accelerometer into sensitive anemometers and imaging spectrometers will be presented.

Hartley, Frank T.↗

NASA Ultra-Sensitive Miniature Accelerometer

Using micro-machined silicon technology, an ultra-sensitive miniature acce.,rometer can be constructed which meets the requirements for microgravity experiments in the space environment.Such an accelerometer will have a full scale sensitivity of 1C2 g a resolution of lC8 g, low cross axis sensitivity, and low temperature sensitivity. Mass of the device is approximately five grams and its footprint is 2 cm x 2 cm. Innovative features of the accelerometer, which are patented, are: electrostatic caging to withstand handling shock up to 150 g, in-situ calibration, in situ performance characterization, and both static and dynamic compensation. The transducer operates on a force balance principle wherein the displacement of the proof mass is monitored by measuring tunneling electron current flow between a conductive tip, and a fixed platen. The four major parts of the accelerometer are tip die, incorporating the tunneling tip and four field plates for controlling pitch and roll of the proof mass; two proof mass dies, attached to the surrounding frame by sets of four leg" springs; and a force plate die. The four parts are fuse-bonded into a complete assembly. External electrical connections are made at bond pads on the front surface of the force plate die. Materials and processes used in the construction of the transducer are compatible with volume production.

Zavracky, Paul M.↗

An all-silicon single-wafer micro-g accelerometer with a combined surface and bulk micromachining process

This paper reports an all-silicon fully symmetrical z-axis micro-g accelerometer that is fabricated on a single-silicon wafer using a combined surface and bulk fabrication process. The microaccelerometer has high device sensitivity, low noise, and low/controllable damping that are the key factors for attaining micro g and sub-micro g resolution in capacitive accelerometers. The microfabrication process produces a large proof mass by using the whole wafer thickness and a large sense capacitance by utilizing a thin sacrificial layer. The sense/feedback electrodes are formed by a deposited 2-3 microns polysilicon film with embedded 25-35 microns-thick vertical stiffeners. These electrodes, while thin, are made very stiff by the thick embedded stiffeners so that force rebalancing of the proof mass becomes possible. The polysilicon electrodes are patterned to create damping holes. The microaccelerometers are batch-fabricated, packaged, and tested successfully. A device with a 2-mm x 1-mm proof mass and a full bridge support has a measured sensitivity of 2 pF/g. The measured sensitivity of a 4-mm x 1-mm accelerometer with a cantilever support is 19.4 pF/g. The calculated noise floor of these devices at atmosphere are 0.23 micro g/sqrt(Hz) and 0.16 micro g/sqrt(Hz), respectively.

Non-NASA Center↗

Dual Accelerometer Usage Strategy for Onboard Space Navigation

This work introduces a dual accelerometer usage strategy for onboard space navigation. In the proposed algorithm the accelerometer is used to propagate the state when its value exceeds a threshold and it is used to estimate its errors otherwise. Numerical examples and comparison to other accelerometer usage schemes are presented to validate the proposed approach.

Zanetti, Renato↗

Self Diagnostic Accelerometer for Mission Critical Health Monitoring of Aircraft and Spacecraft Engines

A self diagnostic accelerometer system has been shown to be sensitive to multiple failure modes of charge mode accelerometers. These failures include sensor structural damage, an electrical open circuit and most importantly sensor detachment. In this paper, experimental work that was performed to determine the capabilities of a self diagnostic accelerometer system while operating in the presence of various levels of mechanical noise, emulating real world conditions, is presented. The results show that the system can successfully conduct a self diagnostic routine under these conditions.

Lekki, John↗

Self Diagnostic Accelerometer Field Programmable Gate Array (SDA FPGA)

A self-diagnostic accelerometer (SDA) field programmable gate array (FPGA) may be capable of real time or near-real time diagnostic processing to determine potential accelerometer issues during flight or other mission critical operational situations. The SDA FPGA may determine accelerometer structural health and an attachment condition using an electronics system that is smaller, more energy efficient, and more cost effective than previous diagnostic tools. Advantages of the system may include diagnosing sensors automatically, immediately, actively (i.e., confirming the fault), and consistently, without the influence of a human operator. Customizable SDA algorithms may be adjusted to the specific needs of the sensor/environment.

Tokars, Roger P.↗

NASA Ultra-Sensitive Miniature Accelerometer

Using micro-machined silicon technology, an ultra-sensitive miniature accelerometer can be constructed which meets the requirements for microgravity experiments in the space environment. Such an accelerometer will have a full scale sensitivity of 10 -2 g, a resolution of 10 -8 g, low cross-axis sensitivity, and low temperature sensitivity. Mass of the device is approximately five grams and its footprint is 2 cm x 2 cm.

miniature↗

Improvements to Calibration Modeling of a Tri-Axial Accelerometer Using Response Surface Methods

Aerodynamic ground test facilities require precision attitude measurements to support fundamental research and aerodynamic vehicle characterization. Accelerometers are used as one solution for measuring test article attitude. Several wind-tunnel facilities experience elevated temperatures during sustained testing of approximately 38°C (100°F) and extremes up to 149°C (300°F). Accelerometer thermal corrections are required to maintain attitude measurement accuracy during elevated temperature tunnel conditions. This manuscript details characterization of non-linear and thermal effects of the Mini/MEMs Tri-Axis Sensor System (MTASS) developed at NASA. Non-linear effects are characterized using a two-axis index head, and temperature effects are characterized using a metallic cube in a thermal chamber. The results show a significant decrease in back-computed residuals for room temperature and elevated temperatures experiments.

Accelerometer↗

Improvements to Calibration Modeling of a Tri-Axial Accelerometer Using Response Surface Methods

Aerodynamic ground test facilities require precision attitude measurements to support fundamental research and aerodynamic vehicle characterization. Accelerometers are used as one solution for measuring test article attitude. Several wind-tunnel facilities experience elevated temperatures during sustained testing of approximately 38°C (100°F) and extremes up to 149°C (300°F). Accelerometer thermal corrections are required to maintain attitude measurement accuracy during elevated temperature tunnel conditions. This manuscript details characterization of non-linear and thermal effects of the Mini/MEMs Tri-Axis Sensor System (MTASS) developed at NASA. Non-linear effects are characterized using a two-axis index head, and temperature effects are characterized using a metallic cube in a thermal chamber. The results show a significant decrease in back-computed residuals for room temperature and elevated temperatures experiments.

Accelerometer↗

Simple device produces accelerometer calibration pulse

Shock-impulse exciter produces a remote checkout of the amplitude calibration and frequency response of a piezoelectric vibration accelerometer. The exciter employs a bimetal spring to apply a mechanical acceleration pulse of a known amplitude and frequency to the accelerometer.

Source record↗

Miniature servo accelerometer is force- balanced

Miniature servo accelerometer measures unusually small forces of torques. The pendulous mass of the accelerometer is suspended by fused quartz torsion fibers in an electromagnetically force- balanced environment. It is used in gravity surveys for exploring mineral deposits.

Johnston, A. R.↗

Damping technique gives accelerometer flat frequency response

Piezoelectric accelerometer uses a viscous damping technique to achieve a flat frequency response over a wide frequency range in high acoustic environments. This eliminates the electrical overload on associated electronics and loss of useful data caused by oscillations of the accelerometer.

Wing, T.↗

Rectilinear accelerometer possesses self- calibration feature

Rectilinear accelerometer operates from an ac source with a phase-sensitive ac voltage output proportional to the applied accelerations. The unit includes an independent circuit for self-test which provides a sensor output simulating an acceleration applied to the sensitive axis of the accelerometer.

Henderson, R. B.↗