Search NASA⌕ Search

SEARCH · Search NASA

Results for “Active cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Photonic Refrigeration from Time-Modulated Thermal Emission

We develop theoretical and computational formalisms to describe thermal radiation from temporally modulated systems. We demonstrate that such a modulation results in a photon-based active cooling mechanism. This mechanism has a high thermodynamic performance that can approach the Carnot limit. Our work points to exciting new avenues in active, time-modulated control of thermal emission for cooling and energy harvesting applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Performance evaluation of a dynamic wall integrated with active insulation and thermal energy storage systems

Thermal energy storage systems in buildings can store cooling/heating energy during non-peak load hours or when renewable energy sources are available for later use when demanded. Using the building envelope as a thermal battery can help to shave the peak load, reduce the burden in electric grids, and enhance the occupant's thermal comfort. Sensible energy storage on wall systems such as thermally activated building systems can provide an active thermal storage strategy. However, most of the stored energy is used through passive means directed by the thermal lag, which can impede the on-demand release of the stored energy. Integrating active insulation systems with building thermal storage systems can increase the flexibility of charging and discharging time and duration. In this study, a wall system equipped with an active insulation system and thermally activated storage system was designed, and its performance on active cooling energy contribution was studied. The performances of energy storage (charging), release (discharging) of the thermal energy storage energy, and the active insulation system were studied separately and together as an integrated system. Results showed that the thermal properties of the thermal energy storage core material and the pipe spacing of both embedded pipes in the thermal energy storage and hydronic pipes used in the active insulation system affected the wall performance the most out of all the tested wall system parameters. During discharging, the heat flux into the wall was as high as 81.92 W/m 2 . This active insulation system's dynamic R-value varied between less than 1ft 2 •°F•h/BTU (0.18 m 2 •K/W) to 98% of the equally thick foam insulation's R-value.

25 ENERGY STORAGE↗

Effect of Cathode Cooling in Three-Dimensional Simulations of an Atmospheric Pressure Glow Discharge

The Atmospheric Pressure Glow Discharge (APGD) is a relatively simple and versatile plasma source used in a wide range of applications. Active cooling of the cathode can effectively mitigate instabilities, leading to glow-to-arc transitions. This study investigates the effect of varying the degree of cathode cooling in APGD with a planar cathode in helium. The plasma flow model incorporates mass conservation, chemical species transport, momentum conservation, conservation of thermal energy of heavy species and of electrons, and electrostatics. The model is applied to time-dependent simulations through a three-dimensional computational domain describing the whole discharge, without geometric symmetry or steady-state assumptions. Simulations of an experimentally characterized APGD explore the effects of electric current and cathode cooling—ranging from thermally insulated to extreme convective cooling. Results show the formation of an annular region with high electric field over the cathode surface under conditions of high current and low cooling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modular Coaxial Power Converter for High-Density Integration into Medium-Voltage Cables

This work proposes to combine the functionality benefits of power electronics with the power density benefits of medium-voltage cables to create a streamlined, high-density power electronics solution that seamlessly integrates with medium-voltage cables. Located at the ends of a medium- or high-voltage line, the proposed converter uses a cascade of coaxial power conversion cells to gradually step down the voltage, and excels in high step-down applications. By mimicking the coaxial geometry of medium-voltage cables, the converter preserves the axisymmetric electric field of the cable which, when combined with a solid insulating dielectric, provides a voltage scaling advantage over conventional planar and PCB-based converter solutions. Similar to medium voltage cables, the converter is fully passively cooled. A passive cooling strategy allows for combined installation with existing medium voltage cable systems without the added cost, maintenance needs, infrastructure, and reliability concerns associated with active cooling systems. The scalability of the modular structure in combination with the integration benefits provide a flexible power electronics system that can adapt to the evolving demands of the grid.

coaxial power conversion cells↗

Report on Year-4 of Water NSTF Matrix Testing: Facility Maintenance and Accident Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental validation of an organic rankine-vapor compression cooling cycle using low GWP refrigerant R1234ze(E)

There is a significant global opportunity to capture and utilize low grade waste heat to reduce fossil fuel consumption, greenhouse gas emissions, and improve energy efficiency across a wide range of industries. In this work, an advanced type of thermally activated cooling system, an organic Rankine-vapor compression cycle (ORVC) with novel heat integration strategies, was designed and tested at a relevant scale for industrial waste heat recovery (300 kW th cooling capacity). The ORVC linked an organic Rankine power cycle and a vapor compression cooling cycle using a turbine and compressor that shared a single shaft. The ORVC test facility absorbed waste heat from a liquid stream at 91 °C to simulate engine coolant in diesel generator sets, rejected heat to a glycol stream at 30 °C, and generated chilled water at 7 °C. A cooling capacity of 264 kW ± 3.5 kW was experimentally validated with a COP of 0.56 ± 0.01 during steady-state operation at the design temperatures. The thermal efficiency, accounting for pump work, of the Rankine cycle was 7.7% ± 0.22% and the COP of the vapor compression cycle was 5.25 ± 0.09. The centrifugal turbo-compressor operated at 31.5 kRPM ± 0.3 kRPM, with a turbine and compressor isentropic efficiencies of 76.7% ± 0.90% and 84.8% ± 0.54%, respectively, with near-perfect power transmission between these components. The pressure drop in the piping and heat exchangers were significantly larger than expected which had a detrimental impact on the performance of the ORVC. In addition, the condenser on the cooling cycle could not deliver the subcooling as specified from the design point modeling. Furthermore, the results from the sensitivity analysis showed that the higher condenser glycol outlet temperature had the largest impact on performance, which is consistent with other analytical models in the literature. When the ORVC simulations were updated with experimental values for isentropic efficiencies of the turbomachinery, the thermal COP was 0.66 which represents an estimate of the predicted performance if test facility limitations are overcome.

30 DIRECT ENERGY CONVERSION↗

Design And Control of Thermal Storage for Ventilative Cooling in Multifamily Buildings (Final Report)

The concept of natural ventilation is to provide a heat sink for cooling the building during the occupancy periods at night and improve indoor thermal comfort during the daytime without or with minimal need for mechanical cooling. Commonly, natural ventilation through the window or mechanical circulation of the air through the ventilation ducts are two key methods used to achieve night ventilation. Due to the increasing electric need for space heating and cooling, renewable energies combined with energy storage systems are receiving attention worldwide nowadays. When designed and controlled properly, this strategy can reduce energy use for cooling, reduce the size of mechanical cooling equipment, reduce peak electrical demand for cooling, and better enable demand flexibility for mechanical cooling equipment. In some cases, ventilative cooling can eliminate the need for mechanical cooling altogether. For these reasons, California’s Building Energy Efficiency Standards have recently added prescriptive requirements that all new single-family residences (in most California climates) must include ventilative cooling systems (aka: “whole house fans”). However, the current standards do not address multifamily buildings because market-available ventilative cooling products are designed for single-family residences and are physically incompatible with many multifamily building archetypes. The results from the study show that the combination of thermal energy storage on building walls along with nighttime ventilation cooling assisted with nighttime ventilation can save total building energy usage by up to 9% and peak load by 16% in moderate climate zones. The controlled nighttime ventilation cooling (activate ventilation only when outdoor conditions are favorable) can also provide total electricity savings of up to 5% and 7% in hot and cold climates, respectively. In the case of moderate climates, kitchen exhaust-assisted nighttime ventilation cooling can eliminate the need for cooling during overnight hours. This can also significantly assist in reducing carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Waste Control Specialists Technical Review Team Report

1. Modeling of Drum 68660 and the WCS Drums: A calibrated model of Los Alamos National Laboratory (LANL) Drum 68660 indicates that pressurization of the drum by restriction of drum venting could have led to the thermal runaway reaction at the Waste Isolation Pilot Plant (WIPP) in 2014, supporting the hypothesis that the contents of the drum were not fundamentally different from the overall remediated nitrate salt (RNS) waste stream. 2. Nitric Acid Reactions and Aging of the Waste: The stability of the WCS RNS waste with respect to autocatalytic thermal runaway due to nitric acid chemistry should increase over time as the nitric acid is depleted from chemical reactions in the drum. However, this cannot be confirmed because of the lack of long-term experimental data on the impact of aging on the reactivity of RNS waste. The calibrated model indicates that the waste drums retain most of their reactive components, metal nitrate salts and sWheat Scoop ® , even after eight years. 3. Pressure Effects and Runaway Reactions: The calibrated model indicates that if the drums and standard waste boxes (SWBs) are not allowed to pressurize during transport or storage and they are stored at historical WIPP repository temperatures, then an autocatalytic thermal runaway event is not expected to occur. Since the cause of Drum 68660 pressurization is not known, decision makers are not able to tailor mitigating strategies to the initiating event. Consequently, mitigating strategies must consider all feasible internal and external events that could lead to the pressurization of the drums. 4. Temperature Effects and Runaway Reactions: Temperature also has a strong influence on the stability of the waste. The calibrated model indicates that cooling the drums or SWBs can reduce the possibility of autocatalytic thermal runaway reactions. Simulations suggest that for a drum with a plugged vent, the probability of thermal runaway may be reduced or eliminated if wastes are maintained at or below 43 °F through active cooling measures from the initiation of transport until emplacement at WIPP.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fluidized Bed Gasification For Conversion of Biomass and Waste Materials to Renewable Hydrogen

This project was undertaken in order to study the potential for hydrogen production, at low cost, from mixtures of biomass and municipal solid waste (MSW). This approach allows for the production of hydrogen with a very low fossil carbon burden, while taking advantage of tipping fees (associated with MSW) to improved process economics. The team sourced three primary feedstocks (wood, MSW, and waste plastics) and characterized them comprehensively using established techniques with a long track record in the field of gasification. All three primary feedstocks were highly reactive and lost most of their mass during initial devolatilization. The production of tars, including heavy tars, was quite high, and was most problematic in the case of the MSW and Waste Plastics feedstocks. Little practical difference was identified between the MSW and Waste Plastics materials, and the addition of bed-forming materials (dolomite and brown alumina) to the feedstocks was found to reduce production of tars during devolatilization under thermogravimetric analysis and/or Fischer Assay conditions. A series of four tests in a lab-scale bubbling-fluidized-bed gasifier, at 50 psig of pressure and about 825 C, confirmed these findings. Pellet feedstocks, broken into fragments, were used for these tests, and pellets comprised of 50% MSW and 50% biomass were found to be the best option in terms of fossil carbon burden, economic potential, and gasification characteristics. Tests were then undertaken in a pilot-scale gasifier facility based on the GTI U-Gas fluidized-bed gasification technology. The feedstock handling train of the 20 TPD U-Gas pilot-scale gasifier located in Des Plaines, IL, was operated under simulated gasification conditions, and the 50/50 pellets were found to be very robust and unproblematic. An improved design for the forward end of the feedstock injection screw of the gasifier was developed and installed. The design approach was based on improved passive cooling of the front-most shroud at the end of the screw, since this approach was found in comprehensive modeling studies to be more than sufficient to accomplish the project objectives associated with this phase of the work, while also avoiding thermal gradients that could have caused heat-stress-induced damage to the refractory around the feedstock inlet if an active cooling approach had been applied. Careful technoeconomic analysis (TEA) of two possible 1000 TPD facilities was carried out. The TEA of conversion of MSW with corn stover in one case, and MSW with woody feedstock in the other case, showed that both had the potential to provide hydrogen at about $1/kg (minimum selling price, 2018 dollar basis). Of the two TEA cases, the one that was based on the conversion of wood in the southeastern USA was found to have slightly better economic potential. The other TEA case was based on a real location in Nebraska and called for corn stover feedstock conversion along with MSW. An underserved communities outreach program plan was developed in cooperation with personnel from the Nebraska Public Power District.

08 HYDROGEN↗

Active and passive cooling approaches for a Southern California residential community

This study assesses cooling strategies in a low-income community in Southern California that lacks air conditioning and struggles with heat and air pollution. We used an urban building energy model and an electric distribution system model to evaluate active and passive cooling measures. The most effective space cooling measures were high-performance air-source heat pumps, cool coatings, window films, and harnessing the space cooling effect from heat pump water heaters. The results show that combining heat pump water heaters with window films and cool coatings reduces heat index hazard hours within buildings by 95 % to 99 % but increases total energy costs (equipment costs plus changes in utility bills) by 20 % to 60 % where the higher end includes building electrical upgrades. These measures also led to increased space heater use during colder months to avoid overcooling. Replacing conventional heaters with air source heat pumps eliminated unsafe indoor temperatures and reduced total energy use, but increased cost by 125 % to 150 %. In total, using heat pumps for space and water heating could reduce primary energy use by up to 57 %. The higher cost of active and passive cooling measures can be mitigated by existing and emerging incentive programs, especially those that support heat pumps. Electric distribution upgrades to support community electrification are estimated to increase utility costs by $\$$25 to $\$$40 per ratepayer per year. The results underscore the potential and challenges of adapting building infrastructure in communities at risk from climate and environmental stressors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Microstructure Alignment Effects from Engineered Cooling during Additive Manufacturing of Alnico Magnets from Prealloyed Powder

Alnico is a rare-earth free; permanent magnet (PM) which maintains its saturation magnetization while at temperatures up to 550°C but lacks the coercivity and energy product needed for a wide range of demanding applications. With an optimal set of processing and manufacturing techniques, Alnico could replace Dy-free Nd-Fe-B magnets in certain applications if the microstructure is textured in a $\langle$001$\rangle$ direction. Additive manufacturing (AM) of near-net-shape magnets may provide such texture. To investigate the possibility, directed-energy deposition (DED) in conjunction with an actively cooled substrate was used to build samples with a compositionally modified, gas-atomized, Alnico 8 alloy. The resulting samples were solutionized and quenched, followed by magnetic annealing and a heat treatment. Magnetic properties and microstructures are compared to previous work.

36 MATERIALS SCIENCE↗

High average current HVDC electron gun for EIC hadron cooling

A critical R&D initiative for the Electron Ion Collider (EIC) involves the design of an electron gun capable of gen erating a high average current and high-brightness electron beam for the hadron cooler. This is essential to preserve hadron beam quality and achieve the collider’s luminosity target of 1 × 10 34 s −1 cm −2 . For an energy recovery linac (ERL)-based hadron cooler, the gun must deliver a high average current of 98.5 mA, a normalized transverse emittance of less than 2 mm−mrad, and a bunch charge of up to 2.5 nC. This proceeding outlines the high-voltage design of a DC gun operating at 500 kV, with conditioning capability up to 600 kV. The design incorporates several unique fea tures, including the use of inverted ceramic at this voltage level, active cooling for the cathode, and large single-crystal multi-alkali cathodes grown on a silicon carbide substrate. High-brightness electron sources are also pivotal for other ad vanced applications, such as high-intensity gamma sources, future 𝑒 + 𝑒 − colliders, and ultra-deep UV sources for the semiconductor industry. Additionally, this paper provides an overview of the hadron cooling approaches planned or proposed for the EIC.

43 PARTICLE ACCELERATORS↗

Evaluation of Second Target Station Target Streaming for the Preliminary Design of the Target Assembly

This report documents the analysis of dose rate fields from a combination of two sources stemming from the target system of the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS) Second Target Station (STS). This analysis supports the target drive components’ lifetime estimates and conventional facilities’ preliminary design. The two sources detailed in this report are the radiation generated by the proton beam incident on the target and the activated cooling water in the pipes at the top of the target assembly. The analysis considers the STS target system in operational configuration, with all shielding in place. The dose rate fields are calculated in the target drive room and through the target drive room ceiling. This report calculates the thickness necessary for the target drive room’s high-density concrete ceiling to meet the 0.25 mrem/hr dose limit requirement in the high bay directly above the target drive room. In addition to sizing the target drive room ceiling, this report includes details of the dose field surrounding the target drive assembly to estimate the deposited dose in the target drive assembly components resulting from both streaming and decay of activated water. Prompt neutrons and gammas generated by the proton beam incident on the target primarily stream along the gaps between the target assembly and core vessel shielding. Because the models and analysis detailed in this report are based on the STS preliminary design, future analysis is needed to support the STS final design.

43 PARTICLE ACCELERATORS↗

Stable heat and particle flux detachment with efficient particle exhaust in the island divertor of Wendelstein 7-X

The island divertor concept is an innovative and promising idea to handle heat and particle exhaust in stellarators. At the Wendelstein 7-X (W7-X) stellarator, this divertor concept plays a central role in the device mission to demonstrate reactor relevant plasma confinement for steady-state time scales of up to 30 minutes in the high-performance campaign (OP2) starting in 2022. During the recently concluded first campaign with the inertially cooled island divertor, a large step in the experimental qualification of this divertor concept has been made. In discharges heated with electron cylotron resonance heating of 5-6 MW, central densities in the range of 0.7-1.2 × 10 20 m -3 have been reached in combination with full divertor heat flux detachment. Also, significant neutral gas pressures and neutral compression ratios were shown for the first time in combination with reduced divertor particle flux. The divertor heat loads drop by an order of magnitude from >5 MW m -2 to below 0.5 MW m-2 with increasing density, and substantial compression of neutrals reaching neutral pressure in the sub-divertor volume of >6.0 × 10 -4 mbar was seen. These elevated neutral pressure levels can be obtained and maintained with an up to 80% reduction of the particle fluxes onto the divertor target tiles. This discharge scenario was held stably detached for up to 28 seconds, which is equivalent to several hundred energy confinement times τ E and longer than the time scales for current relaxation. No impurity accumulation was seen at constant Z eff ≈ 1.5 and the stored energy stayed constant at levels of W dia >600 kJ. The level of neutral pressure and compression reached in this scenario extrapolates well to the steady-state particle exhaust requirements for high-performance steady-state operation in OP2, in which the fully actively cooled high-heat-flux divertor will be available. Finally, an overview of this recently discovered divertor regime is given and the status of the physics understanding based on modeling of these regimes with the EMC3-EIRENE code is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solid State Quantum Refrigeration Superconducting, Absorption and Measurement Based (Final Technical Report)

During this DOE grant, DE-SC0017890, in place for the past six years, all proposed research was carried out and published in peer-reviewed papers, as well as other projects that emerged during the research. In that effort the research team accomplished all proposed research, as well as many closely related research projects discovered and conceived of during the grant. These works included “Efficient Quantum Measurement Engines”, a work published in Physical Review Letters, giving a theory of quantum measurement-based engines, which uses quantum measurement as a resource. These engines are designed to efficiently convert energy from the stochastic quantum measurement process into useful work. Further publications include “Experimental Realization of a Quantum Dot Energy Harvester”, a joint theory and experimental work in collaboration with the group of Charles Smith in Cambridge, UK, as well as long time theoretical collaborators, Rafael Sánchez and Björn Sothmann. This work, featured as an Editor’s Suggestion in Physical Review Letters, realized an earlier theoretical proposal of ours, whereby two resonant tunneling quantum dots are connected to a central electronic cavity that is heated by a hot energy source. We also published “Superconducting Quantum Refrigerator: Breaking and Rejoining Cooper Pairs with Magnetic Field Cycles” a work done in collaboration with experimentalist Francesco Giazotto from ENS Pisa, Italy, which also resulted in a patent. This paper, published in Phys. Rev. Applied, advanced the concept of a cyclic fridge based on the normal/superconducting phase transition together with layered materials separated by tunnel junctions. We also completed the proposed research on a heat transistor, publishing “Thermal transistor and thermometer based on Coulomb-coupled conductors”, carried out as a collaboration between my group and theorists Splettstoesser (Lund U., Sweden), Sothmann (U. Duisburg-Essen, Germany), and Sánchez (U. Autónoma de Madrid, Spain). We carried out an analysis of a quantum coupled to a quantum point contact as a sensitive thermometer and heat transistor. We found the optimal statistical estimator for the temperature and compared it with experiments on the same type of devices. We also investigated autonomous quantum absorption refrigerators using quantum dots to cool by using a very hot thermal reservoir to drive heat between two other reservoirs. In the article “Quantifying the quantum heat contribution from a driven superconducting circuit”, we demonstrated that for a driven superconducting circuit, we showed heat flow provided by a hot source to the qubit can be switched on and off by varying external parameters, the frequency and the intensity of the driving. In the work “Stochastic thermodynamic cycles of a mesoscopic thermoelectric engine”, we reconsidered the autonomous thermoelectric heat engine in terms of underlying cycles. Rather than periodic behavior, the cycles were stochastic in nature. Nevertheless, by undertaking a graph theoretical analysis of the elementary transport processed, great quantitative and qualitative insight could be found. We also considered the quantum measurement process and showed that a quantum version of Maxwell’s demon could be related to the work extraction of a quantum system, closely related to arrow-of-time measures for quantum measurement, as described in our article “Thermodynamics of quantum measurement and Maxwell's demon's arrow of time”. This work was selected in Phys. Rev. A as an Editor’s Suggestion. A recent preprint titled “Cyclic Superconducting Quantum Refrigerators Using Guided Fluxon Propagation” accomplished an important piece of this grant: to propose a new kind of quantum refrigerator using the dynamics of fluxons in a type II superconductor. This invention envisioned a race-track type geometry where fluxons are confined. By applying a gradient of magnetic field together with electric current in a Corbino geometry, the circulating fluxons can actively cool a cold reservoir, realizing a new type of cyclic superconducting refrigerator. We also investigated the possibility of thermal control from different points of view. The application of quantum measurement to the system gives a new kind of control on the system of interest – we have pioneered this approach and shown that measurement can boost the thermal power of quantum engines as described in “Continuous measurement boosted adiabatic quantum thermal machines”. The ability to have heat flows on demand is an outstanding challenge, and we have provided new solutions to this problem in Thermal control across a chain of electronic nanocavities” for a chain of electron cavities using gating voltage control. The control methods using qubit/qubit coupling to create absorption fridges at their most fundamental level have also been developed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Plasma–surface interaction in the stellarator W7-X: conclusions drawn from operation with graphite plasma-facing components

W7-X completed its plasma operation in hydrogen with island divertor and inertially cooled test divertor unit (TDU) made of graphite. A substantial set of plasma-facing components (PFCs), including in particular marker target elements, were extracted from the W7-X vessel and analysed post-mortem. The analysis provided key information about underlying plasma–surface interactions (PSI) processes, namely erosion, transport, and deposition as well as fuel retention in the graphite components. The net carbon (C) erosion and deposition distribution on the horizontal target (HT) and vertical target (VT) plates were quantified and related to the plasma time in standard divertor configuration with edge transform ι = 5/5, the dominant magnetic configuration of the two operational phases (OP) with TDU. The operation resulted in integrated high net C erosion rate of 2.8 mg s -1 in OP1.2B over 4809 plasma seconds. Boronisations reduced the net erosion on the HT by about a factor 5.4 with respect to OP1.2A owing to the suppression of oxygen (O). In the case of the VT, high peak net C erosion of 11μm at the strike line was measured during OP1.2B which converts to 2.5 nm s -1 or 1.4 mg s -1 when related to the exposed area of the target plate and the operational time in standard divertor configuration. PSI modelling with ERO2.0 and WallDYN-3D is applied in an interpretative manner and reproduces the net C erosion and deposition pattern at the target plates determined by different post-mortem analysis techniques. This includes also the 13 C tracer deposition from the last experiment of OP1.2B with local 13 CH 4 injection through a magnetic island in one half module. The experimental findings are used to predict the C erosion, transport, and deposition in the next campaigns aiming in long-pulse operation up to 1800 s and utilising the actively cooled carbon-fibre composite (CFC) divertor currently being installed. The CFC divertor has the same geometrical design as the TDU and extrapolation depends mainly on the applied plasma boundary. Extrapolation from campaign averaged information obtained in OP1.2B reveals a net erosion of 7.6 g per 1800 s for a typical W7-X attached divertor plasma in hydrogen.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Controlling substrate temperature with infrared heating to improve mechanical properties of large-scale printed parts

Additively manufactured parts made with polymer extrusion techniques can be 50-75% weaker in the z-direction (across layers) than in the x- and y-directions. This has been attributed to poor mobility of polymer chains and a low degree of entanglement across a cold deposition interface. This is particularly a challenge when printing large-scale parts, such as with the Big Area Additive Manufacturing (BAAM) system, because layer times can exceed several minutes. The current work presents a method for controlling the temperature of the substrate material on the BAAM just prior to deposition using infrared heating lamps. Additionally, long layer times were simulated by actively cooling the material following deposition of each layer. The effect of substrate temperature on the z-direction mechanical properties of 20% carbon fiber reinforced acrylonitrile butadiene styrene (ABS) was measured for an initial temperature ranging from 50 °C to 150 °C and a preheated temperature ranging from 150 °C to 220 °C. Infrared preheating proved to be very effective when applied to substrates that had cooled considerably, almost doubling the tensile strength and increasing the fracture toughness by a factor of 7x.

36 MATERIALS SCIENCE↗

Facets of hydro power and future trends in a Nordic Context

Hydropower technologies bolster high penetration of variable renewable energies (VREs) in the net zero emissions scenarios. Nevertheless, there are various challenges to meeting the ambitious goal, such as stability, reliability, resiliency, security, lack of reactive power, voltage support and inertia, large-scale storage deployment and coordination, interconnectedness, demand-side response, higher thermal cycles with increased start/stops, and inadequate Levelized Cost of Energy (LCOE) for system-wise VRE integration and profitability. This survey conducts a bottom-up analysis to unveil the opportunities to utilize hydropower facilities and disentangle the nested problem for intertwining design features, control algorithms, operation, optimization approaches, incentives, services, and market mechanisms using a three-pillar framework perspective: grid owners, power producers, and machine designers. The survey identified emerging trends in real-time and capacity markets, flexible power systems, and enhanced grid capabilities, including advanced voltage support and updated grid codes. These developments present significant opportunities for hydropower, such as achieving super-flexibility through hybridization, expanded reactive power capabilities, and advanced operational modes like a synchronous condenser and power adequator functionalities. These opportunities require novel design philosophies — including new winding, stator, and rotor configurations, optimized ventilation, and active cooling systems — to enhance performance under stressed grid and climate conditions. Finally, integrating climate and energy models for multi-basin optimization with finer spatial and temporal granularity enhances the planning accuracy for water management of hydropower while addressing environmental challenges. The review delivers helpful prospective suggestions and tools that would serve researchers, power engineers, and stakeholders in making decisions about hydropower technologies and services in 2050 and beyond.

13 HYDRO ENERGY↗