Search NASA⌕ Search

SEARCH · Search NASA

Results for “Adhesion Mitigation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Experimental evaluation of direct current magnetron sputtered and high-power impulse magnetron sputtered Cr coatings on SiC for light water reactor applications

Two types of physical vapor deposition Cr coatings were deposited on chemical vapor deposited SiC coupons using conventional direct current magnetron sputtering (DCMS) and high-power impulse magnetron sputtering (HiPIMS) to mitigate the corrosion of SiC, an advanced fuel and structural material in light water nuclear reactor cores. Coating microstructure was characterized using scanning electron microscopy and scanning transmission election microscopy. X-ray diffraction analysis was conducted for phase identification and qualitative analysis of residual stresses. The mechanical integrity of the coatings was evaluated using scratch testing, micro-indentation, and nano-indentation tests. Additionally, the microstructure of the DCMS coating consisted of fine columnar grains with nanoscale intercolumnar channels, while the HiPIMS microstructure was denser and free of any columnar defects. The DCMS coating showed a small tensile residual stress, while the HiPIMS coating was under compressive stress. Both types of coatings showed good mechanical integrity in terms of ductility and adhesion to the substrate. Corrosion performance of the coatings was assessed with a 30-day high temperature water autoclave test. Both types of coatings formed a protective Cr 2 O 3 surface layer 20-30 nm thick during the autoclave test. In the DCMS coating, the columnar defects provided permeation pathways for water penetration resulting in oxide formation in the intercolumnar regions in the interior of the coating. Overall, both types of Cr coatings offer promise for the mitigation of hydrothermal corrosion of SiC in light water reactor operating environments.

36 MATERIALS SCIENCE↗

High pressure effects on EBC systems in high temperature environments

Environmental barrier coatings (EBCs) are designed to protect SiCfiber/SiCmatrix ceramic matrix composites (CMCs) in turbine engines by mitigating wear in high-temperature water vapor environments. The failure of EBCs is frequently attributed to the accelerated oxidation of the silicon bond coating layer when exposed to high-temperature steam, leading to the formation of a thickened thermally grown oxide (TGO). TGO growth increases interfacial stress, weakens adhesion, and results in coating spallation. Understanding the impact of high-temperature oxidation of EBC systems is essential for developing accurate lifespan models for turbine components, although pressurized oxidation testing is extremely sparse in the open literature. In this work, oxidation tests were performed on rare earth silicate EBCs coated onto SiC substrates under increased pressure conditions. The coated specimens were tested at 1100°C, 1200°C, and 1300°C at both 1 atm and 10 atm total pressure in steam environments. Subsequent characterization focused on the microstructural evolution of the EBC/Si/SiC system. The experimental findings indicated that TGO behavior is dependent on high-pressure conditions, with elevated pressure leading to an increase in oxide scale thickness and modifications in its morphology.

Ardrey, Kristyn [ORNL] (ORCID:0000000184407796)↗

Reduction of Methane Leaks through Corrosion Mitigation Pre-treatments for Pipelines with Field Applied Coatings

Corrosion of buried, coated steel pipelines transporting natural gas is a significant source of methane emissions, from pipeline venting required for maintenance and repairs and from pipeline leaks and incidents. Corrosion of steel under field applied coatings is an important safety concern for the pipeline industry. This project investigates the application of a field applied alloy over girth welds to mitigate external corrosion of buried coated steel pipelines. Various metallic coating options were considered, which were required to meet several criteria: (1) it must resist corrosion under open-circuit or mild cathodic protection conditions, (2) it must protect the substrate steel, and (3) it must not negatively affect the adhesion of the field coating. Finite element models and lab testing were performed of alloy coating compositions to identify promising alloy types underneath disbonded coatings. Polarization curves of coating alloys were generated to provide the boundary conditions for the COMSOL model to compute potential and current distributions around coated areas. Sacrificial and corrosion-resistant metal alloy coatings were evaluated and optimized using corrosion modeling and laboratory electrochemical testing, where aluminum alloy 5356 (5% Mg) and steel alloy B9 (9% Cr) were selected. Corrosion test coupons were designed and fabricated using thermal spray aluminum 5356 and welded B9 steel overlays on API 5L grade X42 line pipe steel. The corrosion test coupons, with simulated pipe coating damage, were tested in a laboratory soil box and a field pipeline site in Texas for 3-months. Corrosion test coupons were then tested for 6-months at field pipeline sites in Texas and Tennessee to quantify corrosion rates and performance of the aluminum and steel alloys under polyethylene tape and 2-part epoxy coatings, various coating holidays, and with and without cathodic protection.

03 NATURAL GAS↗

Scale-Up and Modeling Efforts Using an Omniphobic Surface Treatment for Mitigating Solids Deposition

Abstract Gas hydrates, waxes and asphaltenes represent some of the most significant flow assurance challenges, especially in subsea lines, where treatment options can be limited. Currently, complete avoidance is the primary strategy for hydrate management, while chemical or mechanical flushing/pigging may be utilized for other solids. Each system must also be treated with individualized solutions, as there have been no proved one-size-fits-all technologies demonstrated to date. As an alternative to constant chemical injection or thermodynamic controls such as insulation or heating, a robust omniphobic surface treatment material has been developed which has been shown in previous studies to significantly reduce the adhesion of flow assurance solids, resulting in lower risk for deposition and plugging of gas hydrates, waxes, and asphaltenes. As part of a Department of Energy study, laboratory scale tests were performed on a variety of apparatuses ranging from micromechanical force (micron scale) to laboratory flow loop testing (meter scale). While the results from these tests have been promising, there can be some disconnects between lab-scale observations and field-scale testing. Several factors can result in discrepancies between small-scale bench-top studies and deployment-scale efforts. These include flow conditions (Reynolds number, flow regime), chemistry (synthetic vs. crude oils, gas composition, and additives), physical differences (pipeline material, size, and geometry), etc. This work will describe the actions taken to better understand the deployment and performance of a material such as this omniphobic surface treatment in field scenarios, and to build confidence for deployment in a production scenario. These efforts include modeling field production scenarios using models developed from lab observations, application of the material to field-scale equipment to better understand application challenges, and expanded survivability and longevity testing. Understanding the bridge between laboratory testing and full-scale deployment allows for better technique and risk mitigation for field scale testing.

03 NATURAL GAS↗

Evaluating steam oxidation kinetics of environmental barrier coatings

Environmental barrier coatings (EBCs) are a commercially proven means of protecting SiC-based materials in gas turbine environments. However, there are little specific data in the literature on the impact of coatings like Yb 2 Si 2 O 7 on preventing accelerated SiO 2 growth in the presence of H 2 O. Quantification of reduced rates are necessary for evaluating and comparing EBC effectiveness and incorporation of silica growth rates into future EBC lifetime models. In this study, baseline kinetics of silica formation on bare Si and chemically vapor deposited (CVD) SiC in the 1250–1425 °C range were obtained via 100 h isothermal exposures in dry air and steam environments utilizing a SiC reaction tube to mitigate specimen volatility. An Arrhenius plot of the resulting rates was constructed, representing baseline minimum and maximum rates for Si and SiC oxidation at ambient pressure. Various EBC systems on CVD SiC substrates including air plasma sprayed (APS) EBCs with and without a Si bond coating and with surface roughening to enhance Yb 2 Si 2 O 7 adhesion were subjected to 1-h furnace cycle testing in air with 90vol%H 2 O at 1250–1350°C for up to 500 cycles. After exposure, silica formation rates were measured and compared to the baseline rates to assess EBC effectiveness, where EBC effectiveness is gauged as the propensity to reduce underlying rates of silica formation. With a Si bond coating, a ~180 µm Yb 2 Si 2 O 7 (YbDS) top coating reduced rates over the entire 1250°-1350°C range. Without a Si bond coating, ~60 µm (YbDS) coatings deposited directly onto CVD SiC exhibited poor adhesion, and had to be deposited onto substrates with enhanced roughness at 1350°C. Finally, while exhibiting good adhesion at 1350°C, overall the single layer YbDS coating exhibited a decreasing effectiveness from 1250° to 1350°C.

36 MATERIALS SCIENCE↗

Corrosion Mitigation and Increased Discharge Capacity in Aqueous Processed Thick Cathodes using Phosphoric Acid Additives

Aqueous processed cathodes for lithium-ion batteries are favorable for both cost and environmental reasons; however, these electrodes still face significant problems with increasing areal capacities (i.e. thickness). Highly basic slurry conditions (pH in excess of 12) corrode the current collector surface and evolve hydrogen gas. Consequently, bubbling at the electrode interface causes substantial damage to the dried electrode. As the loading of these electrodes is increased, damage becomes severe and results in lack of adhesion and cohesion. Here introduction of phosphoric acid to combat the rise in pH and suppress the corrosion at the current collector surface is investigated. Phosphoric acid was added in increments of 0.5, 1.0, and 1.5 wt% and the subsequent effects on slurry rheology, particle size, adhesion, and electrochemical cycling were investigated. A technique is reported for obtaining thick (6-8 mAh/cm2) cathodes that exhibit reduced surface cracking and improved rate performance as compared to control samples.

Kukay, Alexander↗

Environmental barrier coatings on SiC without a silicon bond coating: oxidation resistance, failure modes, and future improvements

Environmental barrier coatings (EBCs) are used to mitigate chemical reactions between SiC ceramic matrix composite (CMC) components and the H 2 O in combustion gas in turbine hot sections. CMCs are currently temperature-limited by the Si-bond coating, which melts at ~ 1414 °C. This work explores EBCs where the bond coating was removed to achieve higher operating temperatures. Various versions of enhanced roughness SiC were utilized to improve EBC adhesion to the substrates prior to 1 h furnace cycle testing in steam at 1250–1425 °C. The enhanced SiC roughness resulted in short coating lifetimes as the roughness was oxidized away with SiO 2 formation. Further, isothermal furnace exposures at 1400–1600 °C showed Yb 2 Si 2 O 7 /Yb 2 SiO 5 EBC microstructural changes, resulting in premature debonding from the substrates. Finally, this work provides baseline requirements for the development of both next-generation EBCs and bond coating strategies to overcome the current limitation of the Si-bond coating melting temperature.

36 MATERIALS SCIENCE↗

Self Assembled Monolayers for Passivated Contacts

Passivated contacts mitigate defects typically encountered due metallization of solar cells. We deposit amorphous silicon (a-Si:H) on an oxidized silicon wafer via PECVD and anneal at high temperature to crystallize into polysilicon passivated contact. One drawback is the absorption of the polysilicon between grid fingers, so removal of this material is desirable to maximize Jsc. Alternatively, interdigitated back contact cells rely on a gap between n- and p- fingers, which is commonly etched to ensure electronic isolation. We utilize a self assembled monolayer (SAM) using hexamethyldisilazane (HMDS) as a precursor to pattern and etch amorphous silicon (a-Si:H) and polysilicon without the need for photoresist. Ultraviolet light exposure oxidizes the HMDS by photocleaving the organic groups [1] of the SAM leaving a patterned SiO2. Directly soaking this in TMAH will eventually etch the SAM and the silicon, where the SiO2 serves as an etch mask. Inversely, a dilute HF dip selectively etches this SiO2 and the SAM remains. A subsequent soak in TMAH selectively etches the underlying silicon, where the SAM serves as an etch mask. Importantly, we find that the SAM can remain intact for metallization, where we measure 10 mO-cm2 specific contact resistivity on n-type polysilicon.

passivation↗

Understanding the role of water-soluble guar gum binder in reducing capacity fading and voltage decay of Li-rich cathode for Li-ion batteries

The practical application of high-capacity Li-rich cathode materials is hindered by capacity fading and voltage decay. The capacity fading and voltage decay could be effectively overcome by using water-soluble guar gum (GG) binder instead of traditional polyvinylidene fluoride (PVDF). However, the specific role of the GG binder is not clear yet, though the GG binder can significantly improve the electrochemical performance of Li-rich cathode. To understand the effect of GG binder on the morphology, microstructure of electrode and electrode/electrolyte interfaces, ex-situ scanning electron microscope (SEM), transmission electron microscope (TEM), X-ray adsorption near edge spectroscopy (XANES), in-situ electrochemical impedance spectroscopy (EIS) were applied to comparatively study the charge-discharge processes of Li-rich Li 1.2 Ni 0.2 Mn 0.6 O 2 cathode when using GG and PVDF as binders. The results indicate that the GG binder can prevent electrode crack and active material loss, ascribing to the strong mechanical adhesion of GG binder with active material particles and current collector. It has found that the GG binder can also induce the formation of a uniform layer on Li 1.2 Ni 0.2 Mn 0.6 O 2 particles’ surface. As a consequence, both the electrolyte decomposition and the electrode corrosion were significantly inhibited. The strong chelation between Mn 2+ and polar OH group restrain Mn ion dissolution, which contributes to surface structural transformation mitigation. Here, our study reveals the role of water-soluble GG binder in reducing capacity fading and voltage decay of Li-rich material and is of great importance in design functional binders for high-performance Li-rich electrodes.

25 ENERGY STORAGE↗

Development of Nanocomposite Coatings for Future Large-Scale Time Projection Chambers

In the context of this award we tested the performance of thin high-resistivity coatings for their potential usage as field shaping systems in future large scale xenon Time Projection Chambers (TPC). A successful implementation of such thin coatings would likely simplify the design of potential future detectors, allowing to overcome some of the challenges observed with traditional systems constituted by massive discrete electrodes. We studied a wide range of materials and characterized their optical and electrical performances as functions of temperature and wavelength. The measurement campaign indicated that uniform coatings covering the full PTFE substrate (usually used as reflector in LXe TPCs) impact too severely on the light collection performance of such detectors when used with deep UV light. Despite tuning the composition and thicknesses of nanocomposite coatings, we were not able to identify a single coating, properly working at LXe temperature, that would simultaneously fulfill the resistance and optical requirements. Following the risk mitigation strategy identified in the proposal we moved the focus of the R&D to identify proper materials that, when coated with grid-like patterns on PTFE, would not alter meaningfully its optical properties (with respect to bare PTFE panels) but would still serve as effective field shaping systems, properly containing the drift field in TPC detectors. Among the various materials we identified germanium as the most promising one, providing a good adhesion to PTFE and the proper range of sheet resistivity. The Ge-patterned coating tested within a small scale LXe TPC showed good performance as a field shape system and, as desired, did not reduce the detector light yield. These results are encouraging and such technology should further be investigated as a potential alternative to more traditional field shaping electrodes. Incidentally, in the context of this R&D, we stumbled upon an unexpected behavior suggesting that some of the treatments performed on the PTFE panels, in preparation of the coatings, meaningfully boosted the PTFE reflectivity. The most probable candidate is the O2 plasma cleaning procedure. This hypothesis will be tested in the near future by operating the small scale TPC at UChicago first with regular PTFE panels and then with panels bombarded with O2 plasma (but no coatings). This finding, if confirmed, might open up the possibility of further boosting UV light collection in future large detectors by performing such a treatment on the PTFE surfaces.

36 MATERIALS SCIENCE↗

Advanced Anti-Fouling Coatings to Improve the Efficiency of Coal Power Plants

As the total cost of carbon to generate energy has become a global concern, operators are increasingly looking at all parts of the generation cycle to find areas where efficiency gains may be found. It has been long identified that fouling of heat exchangers is a persistent cause of up to 2.5% of global CO 2 emissions. Unfortunately, practice has also demonstrated that unless a powerful economic driver exists to encourage preemptive mitigation of fouling, there will always be a strong tendency for operators to minimize any form of intervention due to high costs and challenges in scheduling downtime. The objective of this proposed research effort was to demonstrate how existing power plants could lower their carbon emissions and significantly improve heat transfer efficiency using new surface treatment materials to control fouling in a variety of heat exchange equipment. The surface treatment material which was optimized and deployed in this effort is now known commercially as HeatX. It is a low-surface energy, water- and oil-repellent, abrasion resistant material which can be applied in-situ to a wide variety of previously worn/used/in-service substrates. Once applied, it provides a barrier against corrosion, scale deposit formation, and biofilm adhesion on the circulating water-containing tube-side. Alternatively, if applied to the tube exterior, the non-wetting nature of the surface was demonstrated to promote dropwise condensation, subsequently lowering condenser backpressure and increasing overall plant efficiency. As part of this cooperative effort, the Department of Energy’s support was crucial to de-risk and demonstrate the concept of HeatX, while validating both the performance and economic benefit in multiple pilot field studies. The HeatX material properties were optimized in this effort for full field applicability to heat exchangers and condensers, and Oceanit developed the necessary procedures and protocols to provide enough material to support extended length, multi-year demonstrations in the power generation, desalination, and refining industries, making this technology broadly applicable and ready for commercial transition. Field deployment case studies at thermal power plants have shown that the HeatX treatment can provide economic savings of up to $15,000 per day for an operator based on avoiding maintenance costs and lowering fuel usage. The complete mitigation of fouling effects can increase the efficiency of equipment by up to 7%, in a field where gains of 0.5% are generally seen as operationally significant. The HeatX treatment has also demonstrated exceptional lifetime and compatibility with a wide variety of seawater and hydrocarbon environments, further increasing both the return on investment and the effective emission reduction. Such efficiency improvements correlate to massive carbon savings. For every 1 GW of capacity, operators can see carbon emissions reductions of 300,000 tons of CO 2 per year. When looking at the bigger picture, improved condenser function across the U.S. has the potential to prevent 221.3 million tons of CO 2 emissions, equivalent to the sequestration capacity of 129 million acres of forest. If applied on a global scale, 1.26 billion metric tons of CO 2 could be averted from the atmosphere, the same amount of carbon sequestrated by 1.5 billion acres of forest annually or 262,000 wind turbines operating annually. As businesses across multiple industries take a more active role in focusing on environmental, social, and governance (ESG) solutions as part of their core business operations, HeatX will be an attractive technology for commercial investment.

01 COAL, LIGNITE, AND PEAT↗

A multi-material platform for imaging of single cell-cell junctions under tensile load fabricated with two-photon polymerization

We previously reported a single-cell adhesion micro tensile tester (SCAμTT) fabricated from IP-S photoresin with two-photon polymerization (TPP) for investigating the mechanics of a single cell-cell junction under defined tensile loading. A major limitation of the platform is the autofluorescence of IP-S, the photoresin for TPP fabrication, which significantly increases background signal and makes fluorescent imaging of stretched cells difficult. In this study, we report the design and fabrication of a new SCAμTT platform that mitigates autofluorescence and demonstrate its capability in imaging a single cell pair as its mutual junction is stretched. By employing a two-material design using IP-S and IP-Visio, a photoresin with reduced autofluorescence, we show a significant reduction in autofluorescence of the platform. Further, by integrating apertures onto the substrate with a gold coating, the influence of autofluorescence on imaging is almost completely mitigated. With this new platform, we demonstrate the ability to image a pair of epithelial cells as they are stretched up to 250% strain, allowing us to observe junction rupture and F-actin retraction while simultaneously recording the accumulation of over 800 kPa of stress in the junction. In conclusion, the platform and methodology presented here can potentially enable detailed investigation of the mechanics of and mechanotransduction in cell-cell junctions and improve the design of other TPP platforms in mechanobiology applications.

Autofluorescence↗

Enabling aqueous processing for LiNi 0.80 Co 0.15 Al 0.05 O 2 (NCA)-based lithium-ion battery cathodes using polyacrylic acid

Replacing N-methyl-2-pyrrolidone (NMP) with water in the production of lithium-ion battery cathodes is critical to realizing process cost savings and improved worker safety. LiNi 0.80 Co 0.15 Al 0.05 O 2 (NCA) is a poor fit for aqueous processing due to destructive Al current collector corrosion resulting from highly basic slurries and detrimental surface reconstruction reactions that occur in water. In this study, polyacrylic acid (PAA, MW = 450,000 g·mol -1 ) is examined as a corrosion-mitigating and surface-stabilizing agent. Adding PAA to an aqueous NCA slurry can provide a stable pH (4.0–8.5) for at least 4 h, since the carboxyl groups from PAA dissociate and increase the proton concentration in the slurry. Further, these groups can also adsorb to the surface of NCA particles and provide electrostatic stability from active material particle agglomeration, as revealed by zeta potential measurements. Minor cracking does occur at the electrode surface; this cracking likely caused poorer adhesion to the Al current collector in the aqueous-processed film when compared to the NMP-processed baseline. Electrochemically, the leached Li does cause a lower initial capacity for the aqueous-processed cathode, though the capacity retention of the aqueous-processed cathode is better than the baseline. The cracks in the coating led to a rise in charge transfer resistance that hindered rate capability above 1C.

25 ENERGY STORAGE↗

Corrosion-Resistant Coatings for Mitigation and Repair of Spent Nuclear Fuel Dry Storage Canisters

This report summarizes the results of a literature survey on coatings and surface treatments that are used to provide corrosion protection for exposed metal surfaces. The coatings are discussed in the context of being used on stainless steel spent nuclear fuel (SNF) dry storage canisters for potential prevention or repair of corrosion and stress corrosion cracking. The report summarizes the properties of different coating classes, including the mechanisms of protection, their physical properties, and modes of degradation (thermal, chemical, radiological). Also discussed are the current standard technologies for application of the coatings, including necessary surface pretreatments (degreasing, rust removal, grinding) and their effects on coating adhesion and performance. The coatings are also classified according their possible use for in situ repair; ex situ repair, requiring removal from the overpack; and ex situ prevention, or application prior to fuel loading to provide corrosion protection over the lifetime of the canister.

36 MATERIALS SCIENCE↗

Investigation of the Mechanical Degradation of Zinc-Based Cold Spray Coatings for Steel Pipelines

Internal corrosion in wet natural gas is a big challenge in the oil and gas industry due to corrosive constituents such as carbon dioxide (CO2), hydrogen sulfide (H2S), other forms of sulfur, and water in the gas stream. To mitigate internal corrosion, zinc-based cold spray coatings were designed for use in natural gas pipelines to increase the lifespan of the pipeline network. However, one of the requirements in designing internal coatings is the resistance of the coatings to mechanical forces applied on the pipeline's internal wall during pigging operations. These forces are primarily compressive and shear/friction forces. This study examines material properties that must be considered when evaluating mechanical considerations. To determine the viability of the developed coatings with respect to the shear/friction forces, the shear adhesion and wear resistance of the materials have been evaluated. Shear adhesion testing was performed with modified clevises to determine the shear stress required to cause adhesion failure at the coating/substrate interface. Scanning electron microscopy was utilized to characterize the interfaces after failure. Wear testing was performed on coatings and pipeline materials utilizing pin-on-drum testing. These tests display the stress limitations and wear that the coatings can tolerate from pigging.

mechanical degradation↗

Endogenous Retroviral Elements Generate Pathologic Neutrophils in Pulmonary Arterial Hypertension

Rationale: The role of neutrophils and their extracellular vesicles (EVs) in the pathogenesis of pulmonary arterial hypertension is unclear. Objectives: To relate functional abnormalities in pulmonary arterial hypertension neutrophils and their EVs to mechanisms uncovered by proteomic and transcriptomic profiling. Methods: Production of elastase, release of extracellular traps, adhesion, and migration were assessed in neutrophils from patients with pulmonary arterial hypertension and control subjects. Proteomic analyses were applied to explain functional perturbations, and transcriptomic data were used to find underlying mechanisms. CD66b-specific neutrophil EVs were isolated from plasma of patients with pulmonary arterial hypertension, and we determined whether they produce pulmonary hypertension in mice. Measurements and Main Results: Neutrophils from patients with pulmonary arterial hypertension produce and release increased neutrophil elastase, associated with enhanced extracellular traps. They exhibit reduced migration and increased adhesion attributed to elevated β1-integrin and vinculin identified by proteomic analysis and previously linked to an antiviral response. This was substantiated by a transcriptomic IFN signature that we related to an increase in human endogenous retrovirus K envelope protein. Transfection of human endogenous retrovirus K envelope in a neutrophil cell line (HL-60) increases neutrophil elastase and IFN genes, whereas vinculin is increased by human endogenous retrovirus K deoxyuridine triphosphate diphosphatase that is elevated in patient plasma. Neutrophil EVs from patient plasma contain increased neutrophil elastase and human endogenous retrovirus K envelope and induce pulmonary hypertension in mice, mitigated by elafin, an elastase inhibitor. Conclusions: Elevated human endogenous retroviral elements and elastase link a neutrophil innate immune response to pulmonary arterial hypertension.

60 APPLIED LIFE SCIENCES↗

Cold Spray Deposition of 304L Stainless Steel to Mitigate Chloride-Induced Stress Corrosion Cracking in Canisters for Used Nuclear Fuel Storage

A feasibility study of the cold spray deposition process of 304L stainless steel on 304L stainless steel substrates as a mitigation method for chloride-induced stress corrosion cracking (CISCC) has been investigated under various substrate conditions. The study is aimed at the application of this technology to mitigate CISCC that may potentially occur in or nearthe fusion welded regions of stainless steel canisters in Dry Cask Storage System (DCSS) for used nuclear fuels. Spherical gas-atomized 304L stainless steel powder, in the size range of 25 µm to 44 µm, was used as a feedstock powder for the cold spray process. The powder was deposited on four types of 304L substrates with various surface conditions: as-polished, oxidized, cold-rolled, plates with prototypical CISCC. The effects of cold spray parameters on quality of cold spray coatings were investigated. Thickness, porosity, and phases in the as-deposited materials were evaluated using scanning electron microscopy (SEM) and X-ray diffraction (XRD), and correlated with microhardness and adhesion strength measured via micro-indentation and ASTM C633 pulling test, respectively. XRD analysis of the coatings was also conducted to examine the effects of cold spray condition on residual stress state in the coating. Detailed cross-sectional examination of coating/substrate interfaces was performed with transmission electron microscopy (TEM) equipped with energy dispersive spectroscopy (EDS). Dense and continuous coatings with good adhesion strength and hardness were produced for the various substrate conditions by adjusting cold spray parameters. The results demonstrate that cold spray stainless steel coating is a viable option to provide a physical barrier against CISCC in fusion weld regions of stainless steel in corrosive chloride salt-bearing environments.

Dry Cask Storage Systems, cold spray, 304L stainle↗

Interfacial pressure improves calendar aging of lithium metal anodes

Lithium (Li) metal is a promising anode because its theoretical specific capacity is approximately ten times larger than graphite. However, Li anodes suffer from long-term capacity fade due to Li stranding (becoming electronically disconnected) and electrolyte decomposition. Applied interfacial pressure has been shown to improve Li anode cycling, likely due to reincorporating stranded or “dead” Li into the anode. Calendar aging can also lead to Li capacity loss due to electrolyte decomposition/Li corrosion and the formation of stranded Li. Some research suggests that calendar aging during cycling results in reversible capacity losses due to Li stranding and reconnection. We here investigate the effect of applied interfacial pressure on Li anode calendar aging during cycling with incorporated rest steps in a localized high-concentration electrolyte (LHCE) to understand if pressure can mitigate stranded Li formation during rest by manipulating the Li morphology. Pouch cells exhibit more stable cycling and denser Li deposits between 10 kPa and 1,000 kPa of applied pressure compared to no applied pressure. Despite drops in CE during periodic rest cycles, the average cumulative lost capacity and average coulombic efficiency (CE) of cells over 50 cycles show that cells aged with incorporated rest steps perform similarly to cells cycled without added rests. This similar average CE suggests that dead Li is largely responsible for drops in CE during rest rather than irreversible Li corrosion and that the dead Li can be reconnected in subsequent cycling. The addition of a lithiophilic ZnO coating to the Cu working electrode increases the adhesion and coverage of Li deposits at low pressures and improves CE during the first cycle.

25 ENERGY STORAGE↗