Ultrasonic emission method enables testing of adhesive bonds

Detection of acoustic energy emitted by adhesive bonds subjected to tensile stresses at frequencies above sixteen kilocycles per second is used as a method for determining bond strength. This method is used in measuring adhesive bond strengths on metal honeycomb core panels.

Frank, L.↗

Sample Holder for Cryogenic Adhesive Shear Test

Five samples tested in one cooldown. Holder mounted in testing machine. Submerged in cryogenic liquid held in cryostat. Movable crosshead of testing machine moves gradually downward. Samples placed under tension, one after another, starting with top one; each sample fails in turn before next is stressed.

Ledbetter, F. E.↗

Tunable, Bacterio-Instructive Scaffolds Made from Functional Graphenic Materials

The balance of bacterial populations in the human body is critical for human health. Researchers have aimed to control bacterial populations using antibiotic substrates. However, antibiotic materials that non-selectively kill bacteria can compromise health by eliminating beneficial bacteria, which leaves the body vulnerable to colonization by harmful pathogens. Due to their chemical tunablity and unique surface properties, graphene oxide (GO)-based materials – termed “functional graphenic materials” (FGMs) – have been previously designed to be antibacterial but have the capacity to actively adhere and instruct probiotics to maintain human health. Numerous studies have demonstrated that negatively and positively charged surfaces influence bacterial adhesion through electrostatic interactions with the negatively charged bacterial surface. We found that tuning the surface charge of FGMs provides an avenue to control bacterial attachment without compromising vitality. Using E. coli as a model organism for gram-negative bacteria, we demonstrate that negatively charged Claisen graphene (CG), a reduced and carboxylated FGM, is bacterio-repellent through electrostatic repulsion with the bacterial surface. Though positively charged poly-L-lysine (PLL) is antibacterial when free in solution by inserting into the bacterial cell wall, here, we found that covalent conjugation of PLL to CG (giving PLLn-G) masks the antimicrobial activity of PLL by restricting polypeptide mobility. This allows the immobilized positive charge of the PLLn-Gs to be leveraged for E. coli adhesion through electrostatic attraction. We identified the magnitude of positive charge of the PLLn-G conjugates, which is modulated by the length of the PLL peptide, as an important parameter to tune the balance between the opposing forces of bacterial adhesion and proliferation. We also tested adhesion of gram-positive B. subtilis to these FGMs and found that the effect of FGM charge is less pronounced. B. subtilis adheres nondiscriminatory to all FGMs, regardless of charge, but adhesion is scarce and localized. Overall, this work demonstrates that FGMs can be tuned to selectively control bacterial response, paving the way for future development of FGM-based biomaterials as bacterio-instructive scaffolds through careful design of FGM surface chemistry.

Eckhart, Karoline E.↗

Adhesion Performance of Solid Film Lubricants on Substrates Cleaned With Environmentally Compliant Cleaners

Solid film adhesion testing was used to determine the effect different environmentally compliant cleaners have on the adhesion properties of solid film lubricants used for several NASA programs. In an action to remove ozone depleting chemicals from aerospace processes, a replacement cleaner must be identified that does not affect the adhesion of solid film lubricants used on flight critical NASA hardware. ASTM D251083 Standard Test Method for Adhesion of Solid Film Lubricants was used to evaluate the cleaners. Two different lubricants - Inlox 88 and Boosterlube - were tested using various commercially available cleaners. Inlox 88 is produced by E/M Corporation and is a liquid oxygen compatible lubricant used in the Space Shuttle Main Engine, and Boosterlube is a new lubricant being implemented for use on the Space Shuttle Solid Rocket Booster. These lubricants were selected because of their specific use on flight critical NASA components. Results of this testing are presented in the paper.

Hall, P. B.↗

Abrasive tip treatment for use on compressor blades

A co-spray process was used which simultaneously but separately introduces abrasive grits and metal matrix powder into the plasma stream and entraps the abrasive grits within a molten matrix to form an abrasive coating as the matrix material solidifies on test specimen surfaces. Spray trials were conducted to optimize spray parameter settings for the various matrix/grit combinations before actual spraying of the test specimens. Rub, erosion, and bond adhesion tests were conducted on the coated specimens in the as-sprayed condition as well as on coated specimens that were aged for 100 hours at a temperature of 866K (1100 F). Microscopic examinations were performed to determine the coating abrasive-particle content, the size and shape of the adhesive particles in the coating, and the extent of compositional or morphological changes resulting from the aging process. A nickel chromium/aluminum composite with No. 150 size (0.002 to 0.005 inch) silicon carbide grits was selected as the best matrix/abrasive combination of the candidates surveyed for coating compressor blade tips.

Pedersen, H. C.↗

Cohesive and adhesive degradation in PET-based photovoltaic backsheets subjected to ultraviolet accelerated weathering

Delamination between layers in photovoltaic (PV) backsheets is often reported in the literature, causing voids that can collect moisture, diminish module backside heat dissipation, and reduce the backsheet’s effectiveness as a physical barrier. While backsheets with weathering-resistant fluoropolymer outer layers have traditionally been used in modules, more recent backsheets using non-fluoropolymer outer layers, such as polyethylene terephthalate (PET), have been developed. These backsheets have shown signs of premature degradation, and their adhesion degradation, in particular, has not been widely studied. In the present work, the single cantilever beam (SCB) adhesion test was used to quantify the adhesion energy in two commercially available PET-based backsheets. To study the effect of minor changes in formulation, the backsheets were obtained from same manufacturer and product line but during different years. To study the effect of environmental variables on adhesion degradation, the backsheets were subjected to artificial weathering at controlled temperature, humidity, and ultraviolet (UV) radiation in an indoor weathering chamber, and the adhesion energy was quantified at several intervals of exposure time. Layering structure, composition, and adhesion failure mode were compared between the backsheets, using Raman and infrared spectroscopy and thermogravimetric analysis. The results show a large difference in initial (unexposed) adhesion energy between the backsheets, despite very similar structures and compositions. Following exposure, adhesion energy dropped significantly, primarily due to thermo-hydrolytic degradation of the polyurethane (PU)-based adhesive layers. Significant UV-induced adhesion degradation of the PET outer layer surface was also observed. The study represents an important step in understanding adhesion degradation in PET-based backsheets, suggesting ways in which adhesion integrity – and, correspondingly, module service life – can be improved.

14 SOLAR ENERGY↗

Development of Quality Control Methods for Robust and Reliable Sensor Design

The successful adoption of additive manufacturing for the rapid prototyping of printed sensors requires the establishment of quantifiable metrics that can interrogate device performance. One measure of performance is the adhesion strength between the substrate and sensor interface, which is critical since the strength of this interface can dictate the accuracy and reliability of the printed sensor. In this work, a non-contact laser-induced spallation technique was used to quantify the adhesion of silver prints on an aluminum alloy substrate. The laser-based method was compared to a standardized pull-off adhesion test, which provided baseline measurements of adhesion strength. The sintering conditions were shown to play an important role in the film-substrate adhesion strength, as well as the cohesion and ductility of the film itself. The methods and results described in this work supports the establishment of process control steps that are necessary for verifying the reliability of printed devices prior to its deployment in critical experiments.

36 MATERIALS SCIENCE↗

Adhesion Capabilities of Permanent Foaming Fixatives

DOE-EM have identified an operational requirement for a fixative that can immobilize and/or encapsulate residual contamination in 3D void volumes (pipes, gloveboxes, waste containers, etc.) during D and D activities. Failure to safely and effectively immobilize residual contamination can: Put workers at risk; Contaminate the public and environment; Drive up costs. Commercial-off-the-shelf (COTS) polyurethane (PU) foams is one possible solution and is currently being investigated by Savannah River National Lab (SRNL). Adhesion testing will dictate how well PU foams will adhere and immobilize residual contamination onto a substrate. Results can provide a performance criteria for Section 5 of ASTM E3191: Standard Specification for Permanent Foaming Fixatives Used to Mitigate Spread of Radioactive Contamination. Initial mechanical testing showed intumescent rigid PU foams were best in class (tensile, compression, TGA/DSC) Application of intumescent rigid PU foam in pipe scenario with 'contamination' showed excellent adhesion capabilities as long as foam had contact with pipe. The foam, however, was not able to penetrate 'contamination' but created pockets where the contamination interacted with the substrate. Pretreatment options of pipe were considered to produce better immobilization capabilities. Pretreatment options included COTS products like baking spray, rubber cement, and soap. Foam was still able to immobilize on a global sense, but not a local sense. Essentially acted as a mechanical plug. A tensile tester (MTS Criterion Series 43) was utilized to evaluate the tensile adhesion strength of 6 COTS PU foams. ASTM D1623: Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics. Procedures: PU foams were cured between two smooth 2'' x 2'' 304 stainless steel coupons with hinges glued on plates for gripping support. Parameters Used: Pull rate of 0.1 in/min. Calculations: Tensile adhesion strength, elongation, and ImageJ analysis of how PU foam is left on substrate. Outcome: The PU foam with the best adhesion capabilities would be downselected for further evaluation to be used as a permanent foaming fixative. The rigid PU foams had the best adhesion capabilities with the R1 foam having a max load of 236 N. One of the I-R2 samples reached almost 450 N and another sample reached 2500 N before slipping. The other intumescent foam, I-F4, had the most coverage on the stainless steel coupon's surface from the ImageJ results (61.43% surface coverage). The intumescent foam, I-R2, will be the foam of choice for future testing due its fire retardant and adhesion capabilities. Future directions: Conduct the following experiment in a pipe scenario with the down-selected PU foam. Procedures: PU foam will be cured between in a 304 stainless steel pipe (ID: 4'', OD: 4.5'', Height: 4''). Parameters Used: Compression testing results will be referenced to determine if foam's adhesion strength would be greater its compression strength as its being compressed. Calculations: Compression strength, shear stress, total time elapsed. Conduct further adhesion testing with the down-selected PU foam (I-R2) to be treated as a permanent foaming fixative (PFF). Determine the minimum contact the PFF should have with the substrate for adequate results. Evaluate if PFF's adhesion capabilities is time dependent (3.1.5 of ASTM E3911). Subject PFF to seismic stressors addressed in Safety Basis of Interim Operation documents (SBIO) to further evaluate adhesion capabilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Measurement of Shear Strain in Impact Ice Using a Modified Lap Joint Test and Digital Image Correlation

The results of ice adhesion testing efforts are typically quantified using the maximum shear stress sustained at the interface before the ice detaches from the underlying substrate. While this singular value can be useful for understanding the role icing wind tunnel conditions and substrate surface properties have on the strength of the ice-substrate interface, it does not capture the mechanical behavior of the ice during an experiment. To better understand the deformation of the ice sample and ice-substrate interface during testing, digital image correlation was applied to the lap-joint shear test methodology utilized at NASA Glenn Research Center. Preparation of the sample surface for digital image correlation, initial parsing of the correlation data, and the time synchronization of data from multiple sources are discussed. Using the directional components of deformation measured via digital image correlation, a novel approach to calculating the interfacial shear strain is presented. Results from analyzing several impact ice samples consistently reveals a non-linear response in the ice during mechanical loading which occurs prior to sample delamination, a behavior not observable in the force and displacement data gathered from the testing apparatus. Both the full and small angle forms of the engineering shear strain are evaluated, with the full shear strain form providing considerably lower noise levels. The transition of sample response from near the interface to the bulk behavior of the ice under shear loading is discussed with results from several samples being presented.

Ice adhesion↗

The Measurement of Shear Strain in Impact Ice Using a Modified Lap Joint Test and Digital Image Correlation

The results of ice adhesion testing efforts are typically quantified using the maximum shear stress sustained at the interface before the ice detaches from the underlying substrate. While this singular value can be useful for understanding the role icing wind tunnel conditions and substrate surface properties have on the strength of the ice-substrate interface, it does not capture the mechanical behavior of the ice during an experiment. To better understand the deformation of the ice sample and ice-substrate interface during testing, digital image correlation was applied to the lap-joint shear test methodology utilized at NASA Glenn Research Center. Preparation of the sample surface for digital image correlation, initial parsing of the correlation data, and the time synchronization of data from multiple sources are discussed. Using the directional components of deformation measured via digital image correlation, a novel approach to calculating the interfacial shear strain is presented. Results from analyzing several impact ice samples consistently reveals a non-linear response in the ice during mechanical loading which occurs prior to sample delamination, a behavior not observable in the force and displacement data gathered from the testing apparatus. Both the full and small angle forms of the engineering shear strain are evaluated, with the full shear strain form providing considerably lower noise levels. The transition of sample response from near the interface to the bulk behavior of the ice under shear loading is discussed with results from several samples being presented.

: Ice Adhesion, Digital Image Correlation, Experim↗

Checking Nickel Plate For Porosity

Porosity test goes for free ride with cryogenic adhesion test. Frosted areas marked so pores found after frost disappears. Plating stylus used for local repair of nickel layer.

Roberts, Michael D.↗

Method and Apparatus for the Quantification of Particulate Adhesion Forces on Various Substrates

Mitigation strategies for lunar dust adhesion have typically been limited to qualitative analysis. This technical memorandum describes the generation and operation of an adhesion testing device capable of quantitative assessment of adhesion forces between particulates and substrates. An aerosolization technique is described to coat a surface with a monolayer of particulates. Agitation of this surface, via sonication, causes particles to dislodge and be gravitationally fed into an optical particle counter. Experimentally determined adhesion force values are compared to forces calculated from van der Waals interactions and are used to calculate the work of adhesion using Johnson-Kendall-Roberts (JKR) theory. Preliminary results indicate that a reduction in surface energy and available surface area, through topographical modification, improve mitigation of particulate adhesion.

Wohl, Christopher J.↗

Anti-Fog Coatings For Spacesuit Helmets

A permanent and robust anti-fog coating was developed that is applied to the interior of polycarbonate spacesuit helmets. The coating is a mechanically resilient and permanent superhydrophilic (SHPL) layer produced by a two-step process consisting of a plasma processing pre-etch followed by the deposition of an optically transparent Diamond Like Carbon (DLC) coating to achieve an anti-fog, SHPL-DLC layer with Water Contact Angle (WCA) < 10°. The all-dry vacuum process consists of an oxygen plasma etching to engineer the surface of the polycarbonate, creating a well-controlled nanotextured morphology, which is key to the superhydrophilic properties, followed by vacuum deposited Plasma Enhanced Chemical Vapor Deposition (PECVD) DLC coating with high surface energy. The process is carried out at low temperatures compatible with polycarbonate materials and the two steps are performed back-to-back without breaking vacuum between steps. The process is readily scalable and compatible with large scale production volumes. The SHPL-DLC coating was tested for > 200 hours exposure using a breath simulator with no detrimental effect on the coating performance. The coating was also tested for exposure to cleaning fluids, IPA chemical exposure, adhesion testing per ASTM D3359, and abrasion resistance per MIL-E-12397 with no detrimental effects.

Spacesuit↗