Search NASA⌕ Search

SEARCH · Search NASA

Results for “Airflow distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Small gas turbine combustor primary zone development

Designers of small gas turbine engines prefer a close-coupled compressor to turbine shafting arrangement, which in some designs necessitates the use of a small reverse-flow annular combustor. A design methodology for obtaining the maximum performance potential of these combustors is necessary. This paper describes an approach to optimize the design process and gain insight into primary zone performance through interactive theoretical analyses and experimental tests. Three candidate combustor designs are described which address the performance limiting problem areas associated with small annular combustors. Design methodology centers around understanding and controlling primary zone aerodynamics and the interaction of the distributed fuel with internal airflow patterns. Complete three-dimensional flow field analytical performance prediction procedures are presented and results compared with performance and emission measurements described by probes located at the exit of the primary zone. The effective use of analytical performance prediction methods in the design process is demonstrated.

Sullivan, R. E.↗

Throat stability-by pass systems to increase the stable airflow range of a Mach 2.5 inlet with 60-percent internal contraction

The results of an experimental investigation to increase the stable airflow range (without unstart) of a supersonic mixed-compression inlet are presented. Various stability bypass entrances were located on the cowl side of the inlet throat. The types of entrance were distributed porous (normal holes), forward-slanted slot, and distributed educated slots. A large stable airflow range was obtained for each entrance type if a constant pressure was maintained in the stability bypass plenum. The distributed porous entrance provided the largest stable airflow range. Inlet unstart angle of attack was unaffected by the entrances.

Mitchell, G. A.↗

Effect of air path heat losses at different locations in vapor compression-based clothes dryer: Quasi-steady modeling and design implications

Clothes drying is among the most power-intensive household end uses, and vapor compression-based clothes dryers offer substantial energy cost savings compared with conventional electric heater dryers. However, parasitic heat losses along the air path, that is, heat loss at the upstream of the drum, inside the drum, and at downstream of the drum, remain rarely quantified, but can strongly affect overall performance according to experiments. Here, this study enhances a vapor compression simulation model by integrating a validated drum model using a dimensionless heat-and-mass-transfer effectiveness correlation derived from 63 drying tests in the literature to form a quasi-steady dryer simulation model. The model is validated against laboratory measurements of a baseline dryer. The impact of heat losses is simulated at three locations and explored through 16 heat loss cases spanning two loads (2 and 5 kg), two airflow rates, and multiple loss distributions. For a 5 kg wet load, eliminating pre-drum and in-drum losses reduces total energy use by up to 34–35% and shortens drying time by 27–38% compared with the baseline. At a 2 kg wet load, introducing post-drum heat loss lowers energy costs by up to 23% and reduces operation time by up to 57% compared with the baseline. The results demonstrate that the impact of heat loss is location dependent. Vapor compression dryers should minimize pre-drum and in-drum losses while potentially exploiting post-drum heat dissipation to enhance the drying rate and energy cost savings.

Dryer↗

Enabling residential heating decarbonization through hydronic low-temperature thermal distribution using forced-air assistive devices

Space heating represents approximately one-tenth of the United States’ energy use and has a breadth of potential for emission reduction. An element of space heating, hydronic heat distribution methods, use water supply temperatures up to 82.2 °C (180 °F). However, this operating temperature can be incompatible with high-efficiency heat generation systems, which typically provide heating temperatures of up to 60 °C (140 °F). In this work, a low-cost retrofit solution is developed using experimentally validated computational tools by incorporating an airflow distributor that preferentially directs the airflow from a fan to enhance heat transfer over the finned-tube heat exchanger found in conventional baseboards. The same heat output of traditional baseboard heat distribution systems operating at higher water supply temperatures (71.1 – 82.2 °C) can also be achieved at lower temperatures (≤60 °C). Specifically, results indicate that the technology can produce more than a 46.7% improvement in the heat transfer output at temperatures as low as 60 °C (140 °F), effectively matching the same output range achieved by 71.1 – 82.2 °C (160–180 °F) water supply temperatures. An important benefit of this solution is that it utilizes the existing infrastructure as opposed to requiring the replacement of the entire distribution system. Additionally, this technology enables existing building infrastructure to be coupled with newer, high-efficiency heating systems such as condensing boilers, solar-thermal systems, and geothermal/air-to-water heat pumps that may produce lower water supply temperatures (60 °C). A geospatially resolved techno-economic and environmental analysis is completed and presented to further understand the equivalent carbon footprint of enabling higher efficiency heat generation systems with the improved efficiency heat distribution system disclosed. Using 2021 grid-average emission factors, an emission reduction of up to a 67.5% decrease (2658 kgCO 2 /yr) for a single-family home, depending on state and climate region, could be realized by replacing a traditional natural gas-fired boiler with an air-to-water heat pump coupled to the same high-temperature heat distribution system along with the low-cost retrofit solution. A complete CO 2 emission reduction of 6688 kgCO 2 /yr, depending on state and climate region, could be realized if all electricity is further renewably sourced. Thus, this study provides a possible pathway towards enabling the reduction of operational emissions in space heating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Metrics for Interzonal Dispersion Assessment of Airborne SARS-CoV-2 Within Office Buildings

High ventilation rate is increasingly considered as a mitigation strategy in the rapid spread of COVID-19 in existing buildings in addition to other options like UVGI and added filtration. However, this and other similar measures may also impact energy use and the efficiency of the buildings in which they are installed. Without concrete metrics, the impact of all these potential changes to the system cannot be properly assessed relative to the other impacts the measures might have, including additional energy use, added operation and maintenance costs, and reduced system life. Multizone airflow and contaminant transport simulations involving parameters such as infiltration rate, system configuration, and level of occupancy can provide critical information on relative risk distribution within a building. In this study, prototype airflow models are used to assess the degree to which ventilation-related measures can mitigate the spread of a virus like SARS-CoV-2 in a similar way that prototype energy models are used to study energy efficiency measures. A new detailed medium-sized office building prototype model is developed using the CONTAM software to represent contaminant transport in buildings like those modeled by the U.S. Department of Energy’s detailed medium office prototype model. The goal of this study is to generate a set of suitable metrics that will give a whole-building picture of airborne SARS-CoV-2 virus distributions across the different zones of the building under different parameters and scenarios.

DeGraw, Jason↗

Twenty-five years of aerodynamic research with infrared imaging

A review is presented of the commercial introduction of IR imaging systems in the midsixties that has opened the possibilities to visualize viscous interactions between a body and the surrounding airflow by mapping the surface temperature distributions on configurations of interest. The capability of IR imaging systems to produce in real-time thermograms, which can be interpreted both locally and globally, makes them useful for heat transfer and skin-friction aerodynamic studies. Attention is given to IR systems and data processing, supersonic and hypersonic studies, Space Shuttle flight experiments, subsonic and transonic studies, and propulsion studies.

Gartenberg, Ehud↗

A free-wake rotor analysis including ground effect

The objective of this work is to develop a computer program which analytically estimates the wake geometry, vorticity, and velocity distribution over a rotor and in the neighboring airflow for a variety of conditions in and out of ground effect. The resulting wake is used to provide an assessment of the blade loading distribution for various hover and low speed flight conditions. The computer program is based on a lifting line free wake model and provides stable solutions for a variety of steady state conditions, including ground effect and forward flight. The wake program was validated by comparing the computed wake geometry and experimental test data for two different rotors.

Saberi, H. A.↗

Experimental performance of the regenerator for the Chrysler upgraded automotive gas turbine engine

Automobile gas turbine engine regenerator performance was studied in a regenerator test facility that provided a satisfactory simulation of the actual engine operating environment but with independent control of airflow and gas flow. Velocity and temperature distributions were measured immediately downstream of both the core high-pressure-side outlet and the core low-pressure-side outlet. For the original engine housing, the regenerator temperature effectiveness was 1 to 2 percent higher than the design value, and the heat transfer effectiveness was 2 to 4 percent lower than the design value over the range of test conditions simulating 50 to 100 percent of gas generator speed. Recalculating the design values to account for seal leakage decreased the design heat transfer effectiveness to values consistent with those measured herein. A baffle installed in the engine housing high-pressure-side inlet provided more uniform velocities out of the regenerator but did not improve the effectiveness. A housing designed to provide more uniform axial flow to the regenerator was also tested. Although temperature uniformity was improved, the effectiveness values were not improved. Neither did 50-percent flow blockage (90 degree segment) applied to the high-pressure-side inlet change the effectiveness significantly.

Winter, J. M.↗

The experimental clean combustor program - Description and status

The experimental clean combustor program is a contract effort with primary objectives including the generation and demonstration of technology for development of advanced commercial CTOL aircraft engines with lower exhaust emissions than current aircraft, and the demonstration of this technology in full scale engines in 1976. The program is being conducted in three phases. These consist of screening of low pollutant combustors, refinement of the best combustors, and engine demonstration of the best combustors. Pollution goals are emission index values of 20 and 4 for carbon monoxide and unburned hydrocarbons respectively at engine idle conditions, and an oxides of nitrogen emission index level of 10 at engine takeoff conditions. Pollution reduction approaches which are being investigated include multiple burning zone combustors, investigations of improved fuel distribution, and preparation and the staging of combustor airflow.

Niedzwiecki, R. W.↗

Experimental evaluation of fuel preparation systems for an automotive gas turbine catalytic combustor

Spatial fuel distributions, degree of vaporization, pressure drop and air velocity profiles were measured. Three airblast injectors and an air-assist nozzle were tested. Air swirlers were used to improve the spatial fuel-air distribution. The work was done in a 12 cm tubular duct. Test conditions were: a pressure of 0.3 and 0.5 MPa, inlet air temperatures up to 800 K, air velocities of 10 20 m/s and fuel-air ratios up to 0.020. The fuel was Jet A. The best results were obtained with an airblast configuration that used multiple cones to provide high velocity air for atomization and also straightened the inlet airflow. With this configuration, uniform spatial fuel-air distributions were obtained with mixing lengths greater than 17.8 cm. In this length, vaporization of the fuel was 98.5 percent complete at an inlet air temperature of 700 K. The total pressure loss was 1.0 percent with a reference velocity of 20 m/s and 0.25 percent at 10m/s. The air velocity was uniform across the duct and no autoignition reactions were observed.

Tacina, R. R.↗

Application of the Analogy Between Water Flow with a Free Surface and Two-dimensional Compressible Gas Flow

The theory of hydraulic analogy, that is, the analogy between water flow with a free surface and two-dimensional compressible gas flow and the limitations and conditions of the analogy are discussed. A test run was made using the hydraulic analogy as applied to the flow about circular cylinders at various diameters at subsonic velocities extending to the super critical range. The apparatus and techniques used in this application are described and criticized. Reasonably satisfactory agreement of pressure distributions and flow fields existed between water and airflow about corresponding bodies. This agreement indicated the possibility of extending experimental compressibility research by new methods.

Orlin, W James↗

Experimental evaluation of fuel preparation systems for an automotive gas turbine catalytic combustor

Premixing-prevaporizing fuel systems were evaluated for use with a catalytic reactor for possible automotive gas turbine application. Spatial fuel-air distributions, degree of vaporization, pressure drop and air velocity profiles were measured. Three airblast injectors and an air-assist nozzle were tested. Air swirlers were used to improve the spatial fuel-air distribution. The work was done in a 12 cm tubular duct. Test conditions were: a pressure of 0.3 and 0.5 MPa, inlet air temperatures up to 800 K, air velocities of 10 and 20 m/s and fuel-air ratios up to 0.020. The fuel was Jet A. The best results were obtained with an air-blast configuration that used multiple cones to provide high velocity air for atomization and also straightened the inlet airflow. With this configuration, uniform spatial fuel-air distributions were obtained with mixing lengths greater than 17.8 cm. In this length, vaporization of the fuel was 98.5 percent complete at an inlet air temperature of 700 K. The total pressure loss was 1.0 percent with a reference velocity of 20 m/s and 0.25 percent at 10 m/s. The air velocity was uniform across the duct and no autoignition reactions were observed.

Tacina, R. R.↗

The response of stationary planetary waves to tropospheric forcing

The lower boundary forcing of airflow over topography, and the internal forcing that results from the geographical distribution of diabatic heating, are studied in light of a steady state, linear, quasi-geostrophic model of stationary waves on a sphere. The lower boundary vertical motions forced by airflow over topography depend on whether the horizontal deflection of airflow around topographic features is taken into account, the level of the wind profile at which flow over topography is assumed to take place, and the topographic data set that was used in the forcing formulation. The lower boundary forcing is taken to be given by the observed stationary planetary wave in lower boundary geopotential height, and the internal forcing is computed using the planetary wave propagation equation on the observed wave structure.

Alpert, J. C.↗

Venturi nozzle effects on fuel drop size and nitrogen oxide emissions

The effect of a venturi nozzle on the Sauter mean diameter of a water spray produced by a simplex pressure atomizing injector in a swirling airflow was determined. A Malvern particle and droplet size distribution analyzer, Type S.T. 1800, was used to measure D sub 32 of the water sprays. The water spray was studied at ambient temperature (293 K) and atmospheric pressure. The venturi reduced D sub 32 by an average of 30 percent when installed with a simplex injector and air swirler. The venturi primarily improved atomization of the injector spray by increasing relative air velocity. The small drop size enhanced vaporization and therefore decreased oxides of nitrogen in a combustor. The decrease in drop size provided by the addition of a venturi explains the results obtained in a previous small scale research combustor wherein NOx emission indices decreased as a result of this hardware modification.

Johnson, S. M.↗

Assessment and Mission Planning Capability For Quantitative Aerothermodynamic Flight Measurements Using Remote Imaging

High resolution calibrated infrared imagery of vehicles during hypervelocity atmospheric entry or sustained hypersonic cruise has the potential to provide flight data on the distribution of surface temperature and the state of the airflow over the vehicle. In the early 1980 s NASA sought to obtain high spatial resolution infrared imagery of the Shuttle during entry. Despite mission execution with a technically rigorous pre-planning capability, the single airborne optical system for this attempt was considered developmental and the scientific return was marginal. In 2005 the Space Shuttle Program again sponsored an effort to obtain imagery of the Orbiter. Imaging requirements were targeted towards Shuttle ascent; companion requirements for entry did not exist. The engineering community was allowed to define observation goals and incrementally demonstrate key elements of a quantitative spatially resolved measurement capability over a series of flights. These imaging opportunities were extremely beneficial and clearly demonstrated capability to capture infrared imagery with mature and operational assets of the US Navy and the Missile Defense Agency. While successful, the usefulness of the imagery was, from an engineering perspective, limited. These limitations were mainly associated with uncertainties regarding operational aspects of data acquisition. These uncertainties, in turn, came about because of limited pre-flight mission planning capability, a poor understanding of several factors including the infrared signature of the Shuttle, optical hardware limitations, atmospheric effects and detector response characteristics. Operational details of sensor configuration such as detector integration time and tracking system algorithms were carried out ad hoc (best practices) which led to low probability of target acquisition and detector saturation. Leveraging from the qualified success during Return-to-Flight, the NASA Engineering and Safety Center sponsored an assessment study focused on increasing the probability of returning spatially resolved scientific/engineering thermal imagery. This paper provides an overview of the assessment task and the systematic approach designed to establish confidence in the ability of existing assets to reliably acquire, track and return global quantitative surface temperatures of the Shuttle during entry. A discussion of capability demonstration in support of a potential Shuttle boundary layer transition flight test is presented. Successful demonstration of a quantitative, spatially resolved, global temperature measurement on the proposed Shuttle boundary layer transition flight test could lead to potential future applications with hypersonic flight test programs within the USAF and DARPA along with flight test opportunities supporting NASA s project Constellation.

Horvath, Thomas↗

Cast Glance Near Infrared Imaging Observations of the Space Shuttle During Hypersonic Re-Entry

High resolution calibrated infrared imagery of the Space Shuttle was obtained during hypervelocity atmospheric entries of the STS-119, STS-125 and STS128 missions and has provided information on the distribution of surface temperature and the state of the airflow over the windward surface of the Orbiter during descent. This data collect was initiated by NASA s Hypersonic Thermodynamic Infrared Measurements (HYTHIRM) team and incorporated the use of air- and land-based optical assets to image the Shuttle during atmospheric re-entry. The HYTHIRM objective is to develop and implement a set of mission planning tools designed to establish confidence in the ability of an existing optical asset to reliably acquire, track and return global quantitative surface temperatures of the Shuttle during entry. On Space Shuttle Discovery s STS-119 mission, NASA flew a specially modified thermal protection system tile and instrumentation package to monitor heating effects from boundary layer transition during re-entry. On STS-119, the windward airflow on the port wing was deliberately disrupted by a four-inch wide and quarter-inch tall protuberance built into the modified tile. In coordination with this flight experiment, a US Navy NP-3D Orion aircraft was flown 28 nautical miles below Discovery and remotely monitored surface temperature of the Orbiter at Mach 8.4 using a long-range infrared optical package referred to as Cast Glance. Approximately two months later, the same Navy Cast Glance aircraft successfully monitored the surface temperatures of the Orbiter Atlantis traveling at approximately Mach 14.3 during its return from the successful Hubble repair mission. In contrast to Discovery, Atlantis was not part of the Boundary Layer Transition (BLT) flight experiment, thus the vehicle was not configured with a protuberance on the port wing. In September 2009, Cast Glance was again successful in capturing infrared imagery and monitoring the surface temperatures on Discovery s next flight, STS-128. Again, NASA flew a specially modified thermal protection system tile and instrumentation package to monitor heating effects from boundary layer transition during re-entry. During this mission, Cast Glance was able to image laminar and turbulent flow phenomenology optimizing data collection for Mach 14.7. The purpose of this paper is to describe key elements associated with STS-119/125/128 mission planning and execution from the perspective of the Cast Glance flight crew that obtained the imagery. The paper will emphasize a human element of experience, expertise and adaptability seamlessly coupled with Cast Glance system and sensor technology required to manually collect the required imagery. Specific topics will include a near infrared (NIR) camera upgrade that was implemented just prior to the missions, how pre-flight radiance modeling was utilized to optimize the IR sensor configuration, communications, the development of aircraft test support positions based upon Shuttle trajectory information, support to contingencies such as Shuttle one orbit wave-offs/west coast diversions and then the Cast Glance perspective during an actual Shuttle imaging mission.

Tack, Steve↗