Search NASA⌕ Search

SEARCH · Search NASA

Results for “Alaska Natives”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

38 records · Page 3

Polymer Retention Evaluation in a Heavy Oil Sand for a Polymer Flooding Application on Alaska’s North Slope

For a polymer flooding field trial in a heavy oil reservoir on Alaska’s North Slope, polymer retention is a key parameter. Because of the economic impact of retention, this parameter was extensively studied using field core material and conditions. Several important findings were noted. Polymer retention based on effluent viscosity measurements can be overestimated unless the correct (non-linear) relation between polymer concentration and viscosity is used. Polymer degradation (either mechanical or oxidative) can also lead viscosity-based measurements to overestimate retention. Inaccessible pore volume (IAPV) can be overestimated if insufficient brine is flushed through the sand between polymer banks. Around 100 pore volumes (PV) of brine may be needed to displace mobile polymer to approach a true residual resistance factor and properly measure IAPV. Even for a sand pack with kwsor = 20 mD, IAPV was zero for HPAM with molecular weight (Mw) of 18 million g/mol. Fine-grain particles (<20 μm) strongly impacted polymer retention values. Native NB#1 sand with a significant component of particles <20 μm exhibited 290 μg/g, while the same sand exhibited 28 μg/g after these small particles were removed. Polymer retention did not necessarily correlate with mineral composition. The NB#1, NB#3, and OA sands had similar elemental and clay compositions, but the NB#1 sand exhibited ~10 times higher retention than the NB#3 sand. Polymer retention did not necessarily correlate with permeability. NB#1 sand exhibited much higher retention than OA sand, even though NB#1 sand was twice as permeable as OA sand. No evidence of chromatographic separation of HPAM molecular weights was found in our experiments. Although retention tended to be greater without a residual oil saturation (than at Sor), the effect was not strong. Aging a core (with high oil saturation) at 60°C reduced HPAM retention by a factor of two. As expected, under similar conditions, polymer retention was greater for a higher Mw HPAM (18 million g/mol) than for a lower Mw HPAM (10-12 million g/mol). In many cases with high polymer retention values (e.g., 240 μg/g), polymer arrival at the end of the core was relatively quick, but achieving the injected concentration occurred gradually over many pore volumes. This effect was not due chromatographic separation of polymer molecular weights. Results from modeling of this behavior was consistent with concentrationdependent polymer retention. The form assumed for the retention function in a simulator can have an important impact on the timing and magnitude of the oil response from a polymer flood. Field-based observations can underestimate polymer retention, depending on when the tracer and polymer concentrations were measured and the assumptions made about reservoir heterogeneity.

Wang, Dongmei↗

Akiachak Energy Efficiency Retrofit Project

The goal of the project is to reduce the overall energy use of the Akiachak Native Community (ANC) by implementing energy efficiency measures in five high-use Tribal buildings. This project will have the following outcomes: Projected annual energy savings of $17,369; projected annual reduction in fuel oil #1 of 1,200 gallons and electricity of 17,751 kWh; annual reduction in carbon dioxide emissions of approximately 60,340 pounds/year. ANC will install energy efficiency measures in the Laundry, Tribal Indian Reorganization Act (IRA) Office, Clinic, Daycare, and Police Station. ANC obtained energy audits on these buildings in 2018, and this project will implement high-payback recommendations such as replacing lighting with LEDs, installing setback thermostats and occupancy sensors, replacing furnaces with more efficient models, replacing the circulation pumps with variable speed ones, air tightening, and adding insulation. Buildings will see energy cost reductions from 15% to 40%. These retrofits will help build ANC’s long-term vision for sustainable energy usage and address the first goal of the Tribal IRA Council’s Energy Efficiency and Conservation Strategy, to “create and maintain functionally appropriate, sustainable, accessible, high quality tribal infrastructure and facilities.” ANC intends to replicate this project by using the resulting energy savings to address audit recommendations in other buildings as well as to demonstrate the value of energy efficiency to community members. Other outcomes will include an increase in community resiliency, reduced dependence on outside shipments of fuel oil, training for maintenance staff, and no-touch control of building appliances to reduce transmission of diseases such as COVID-19.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗