Search NASASearch

SEARCH · Search NASA

Results for “Allan Variance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Rubidium and cesium frequency standards status and performance on the GPS program

The on-oribt operational performance of the frequency standards on the Global Positioning System (GPS) 1 to 10 NAVSTAR satellites are discussed. The history of the Rb frequency standards showing the improvements incorporated at various stages of the program and the corresponding results are presented. Also presented is the operational history of the NAVSTAR cesium frequency standards. The frequency standards configuration data presented covers the chronology of events from the concept validation satellites, NAVSTAR 1 to 10, starting in 1978 to the present, including the configurations of clocks to be used on the GPS Production Program. Data are presented showing the results of long-term laboratory testing of a production Rb frequency standard with the necessary data taken to calculate Delta F, drift, time error, and Allan variance.

Bethke, H.

Performance data of US Naval Observatory VLG-11 hydrogen masers since September, 1983

In 1983, two VLC-11 masers were delivered to the U.S. Naval Observatory by the Smithsonian Astrophysical Observatory. Last year the short-term stability of these masers was reported and the effect of this short-term stability on timekeeping performance was examined. Since the date of installation, 13 September 1983, data on the masers' long-term performance have been accumulated. The Allan variance, agma(tau), of the relative frequency between the masers reaches a minimum of about 4 parts in 10 to the 16th power at averaging times 5,000 seconds and rises at longer averaging times due, at least partly, to systematic frequency drift. The systematic frequency drifts, expressed in units of fractional frequency difference per day are discussed.

Vessot, R. F. C.

Maintenance of time and frequency in the Jet Propulsion Laboratory's Deep Space Network using the Global Positioning System

The Deep Space Network (DSN), managed by the Jet Propulsion Laboratory for NASA, must maintain time and frequency within specified limits in order to accurately track the spacecraft engaged in deep space exploration. Various methods are used to coordinate the clocks among the three tracking complexes. These methods include Loran-C, TV Line 10, Very Long Baseline Interferometry (VLBI), and the Global Positioning System (GPS). Calculations are made to obtain frequency offsets and Allan variances. These data are analyzed and used to monitor the performance of the hydrogen masers that provide the reference frequencies for the DSN Frequency and Timing System (DFT). Areas of discussion are: (1) a brief history of the GPS timing receivers in the DSN, (2) a description of the data and information flow, (3) data on the performance of the DSN master clocks and GPS measurement system, and (4) a description of hydrogen maser frequency steering using these data.

Clements, P. A.

Frequency stability review

Certain aspects of the description and measurement of oscillator stability are treated. Topics covered are time and frequency deviations, Allan variance, the zero-crossing counter measurement technique, frequency drift removal, and the three-cornered hat.

Greenhall, C. A.

The JPL trapped mercury ion frequency standard

In order to provide frequency standards for the Deep Space Network (DSN) which are more stable than present-day hydrogen masers, a research task was established under the Advanced Systems Program of the TDA to develop a Hg-199(+) trapped ion frequency standard. The first closed-loop operation of this kind is described. Mercury-199 ions are confined in an RF trap and are state-selected through the use of optical pumping with 194 nm UV light from a Hg-202 discharge lamp. Absorption of microwave radiation at the hyperfine frequency (40.5 GHz) is signaled by atomic fluorescence of the UV light. The frequency of a 40.5 GHz oscillator is locked to a 1.6 Hz wide atomic absorption line of the trapped ions. The measured Allan variance of this locked oscillator is currently gamma sub y (pi) = 4.4 x 10 to the minus 12th/square root of pi for 20 is less than pi is less than 320 seconds, which is better stability than the best commercial cesium standards by almost a factor of 2. This initial result was achieved without magnetic shielding and without regulation of ion number.

Prestage, J. D.

A digitally implemented phase-locked loop detection scheme for analysis of the phase and power stability of a calibration tone

A digital phase-locked loop (PLL) scheme is described which detects the phase and power of a high SNR calibration tone. The digital PLL is implemented in software directly from the given description. It was used to evaluate the stability of the Goldstone Deep Space Station open loop receivers for Radio Science. Included is a derivative of the Allan variance sensitivity of the PLL imposed by additive white Gaussian noise; a lower limit is placed on the carrier frequency.

Densmore, A. C.

Operating and environmental characteristics of Sigma Tau hydrogen masers used in the Very Long Baseline Array (VLBA)

Presented here are the results obtained from performance evaluation of a pair of Sigma Tau Standards Corporation Model VLBA-112 active hydrogen maser frequency standards. These masers were manufactured for the National Radio Astronomy Observatory (NRAO) for use on the Very Long Baseline Array (VLBA) project and were furnished to the Jet Propulsion Laboratory (JPL) for the purpose of these tests. Tests on the two masers were performed in the JPL Frequency Standards Laboratory (FSL) and included the characterization of output frequency stability versus environmental factors such as temperature, humidity, magnetic field, and barometric pressure. The performance tests also included the determination of phase noise and Allan variance using both FSL and Sigma Tau masers as references. All tests were conducted under controlled laboratory conditions, with only the desired environmental and operational parameters varied to determine sensitivity to external environment.

Tucker, T. K.

Effect of laser frequency noise on fiber-optic frequency reference distribution

The effect of the linewidth of a single longitude-mode laser on the frequency stability of a frequency reference transmitted over a single-mode optical fiber is analyzed. The interaction of the random laser frequency deviations with the dispersion of the optical fiber is considered to determine theoretically the effect on the Allan deviation (square root of the Allan variance) of the transmitted frequency reference. It is shown that the magnitude of this effect may determine the limit of the ultimate stability possible for frequency reference transmission on optical fiber, but is not a serious limitation to present system performance.

Logan, R. T., Jr.

Digital Doppler extraction demonstration with the advanced receiver

A digital Doppler extraction demonstration with the Advanced Receiver 2 (ARX 2) tracking Pioneer 10 and Voyager 2 is described. The measured results are compared with those of the Block 4 receiver that was operating in parallel with the ARX 2. It is shown that the ARX 2 outperforms the Block 4 receiver in terms of Allan variance of the Doppler residuals, the amount of which depends on the scenario of interest.

Hinedi, S.

Geodetic positioning of the Aerospace Electronics Research Lab (ERL) Osborne Time Transfer Receiver (TTR) using the GPS NAVSTAR Block I satellites

Aerospace has routinely processed the Osborne Time Transfer Receiver (TTR) data for the purpose of monitoring the performance of ground and GPS atomic clocks in near real-time with on-line residual displays and characterizing clock stability with Allan Variance calculations. Recently, Aerospace added the ability to estimate the TTR's location by differentially correcting the TTR's location in the WGS84 reference system. This new feature is exercised on a set of TTR clock phase data and Sub-meter accurate station location estimates of the TTR at the Aerospace Electronic Research Lab (ERL) are obtained.

Liu, Anthony S.

Frequency shifts in a rubidium frequency standard due to coupling to another standard

Highly reliable timing system, such as used on board satellites, may incorporate a hot standby atomic clock besides the active one. RF couplings between them may affect the performance of the active clock. The effect of such couplings between two rubidium atomic clocks was investigated, and it was found that they will add an oscillatory term to the Allan Variance of the active clock, degrading its frequency stability, and that under certain circumstances they may also shift the active clock's operating frequency. These two effects are discussed in detail, and the level of isolation required to render them negligible is established.

Jaduszliwer, Bernardo

A 492 GHz cooled Schottky receiver for radio-astronomy

We developed a 492 GHz cooled GaAs Schottky receiver driven by a solid state local oscillator with a DSB noise temperature of 550 K measured at the telescope. The receiver-bandwidth is approx. equal to 1.0 GHz. Quasi-optical mirrors focus the sky and local oscillator radiation into the mixer. Stability analysis via the Allan variance method shows that the total system including a 1 GHz bandwidth acousto-optical spectrometer built in Cologne allows integration times up to 100 sec per half switching cycle. We successfully used the receiver at the KOSMA 3 m telescope on Gornergrat (3150m) located in the central Swiss Alps near Zermatt during January-February 1992 for observations of the 492 GHz, (CI) (3)P1 to (3)P0 fine structure line in several galactic sources. These observations confirm that Gornergrat is an excellent winter submillimeter site in accordance with previous predictions based on the atmospheric opacity from KOSMA 345 GHz measurements.

Hernichel, J.

Recipes for degrees of freedom of frequency stability estimators

The Allan variance for an averaging time tau can be estimated either from all available phase samples or from a subgrid of samples with spacing tau. This paper gives a set of computational recipes that yield the variance of both estimators, with less than 2 percent error, for the five power-law components of the classical continuous-time clock noise model.

Greenhall, Charles A.

Measuring Frequency Instability Of A Large Antenna

Frequency instability of antenna under test determined from measurement of phase deviation between outputs of two antennas. Fiber-optic system used to minimize spurious component of frequency instability contributed by propagation of signal from reference antenna to Allan-variance-measuring instrument. Intended primarily to reveal contributions of wind and air-temperature effects on antenna and beam-waveguide structures to overall frequency instabilities of received signals. Technique simpler, less expensive, potentially capable of providing instability data in shorter measuring times, and more precise.

Otoshi, Tom Y.

Confidence of the three-point estimator of frequency drift

It was shown that a three-point second difference estimator is nearly optimal for estimating frequency drift in many common atomic oscillators. A formula for the uncertainty of this estimate as a function of the integration time and of the Allan variance associated with this integration time is derived.

Weiss, Marc A.

The effects of clock errors on timescale stability

The weighting scheme for the cesium clocks and hydrogen masers constituting the USNO timing ensemble is reexamined from an empirical standpoint of maximizing both frequency accuracy and timescale uniformity. The utility of a sliding-weight relation between the masers and the cesiums is reaffirmed, but improvement is found if one incorporates inverse Allan variances for sampling times of 12 and 6 hours for the cesiums and masers, respectively, with some dependence on clock model.

Breakiron, Lee A.

Noise Diode Stability Measurements Using a 4.3 GHz Laboratory Radiometer

The need for passive microwave radiometry using aperture synthesis and phased arrays for large apertures requiring more stability has generated several studies. The in-flight calibration and, therefore, the stability of such systems is an important design consideration. A 4.3 GHz laboratory radiometry operating in a balanced Dicke mode has been developed for making precise brightness (noise) temperature measurements. The stability of the noise diode source used in the noise-injection loop is of interest. A statistical Allan variance method to characterize the stability of the radiometer and the noise diode is presented in this paper. Noise measurements which demonstrate this approach are also included.

Scherner, M. J.

Time-Dependent Selection of an Optimal Set of Sources to Define a Stable Celestial Reference Frame

Temporal statistical position stability is required for VLBI sources to define a stable Celestial Reference Frame (CRF) and has been studied in many recent papers. This study analyzes the sources from the latest realization of the International Celestial Reference Frame (ICRF2) with the Allan variance, in addition to taking into account the apparent linear motions of the sources. Focusing on the 295 defining sources shows how they are a good compromise of different criteria, such as statistical stability and sky distribution, as well as having a sufficient number of sources, despite the fact that the most stable sources of the entire ICRF2 are mostly in the Northern Hemisphere. Nevertheless, the selection of a stable set is not unique: studying different solutions (GSF005a and AUG24 from GSFC and OPA from the Paris Observatory) over different time periods (1989.5 to 2009.5 and 1999.5 to 2009.5) leads to selections that can differ in up to 20% of the sources. Observing, recording, and network improvement are some of the causes, showing better stability for the CRF over the last decade than the last twenty years. But this may also be explained by the assumption of stationarity that is not necessarily right for some sources.

Le Bail, Karine