Search NASA⌕ Search

SEARCH · Search NASA

Results for “Alpha Spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

GaAs Schottky Barrier Detectors for Alpha-Particle Spectrometry at Temperatures up to 120°C

GaAs Schottky barrier detectors for α particle spectrometry have been tested. Detectors had an input window area of 80 mm{sup 2} and a working barrier layer thickness of 40–50 μm. The energy resolution (FWHM) measured on 5.499 MeV α line of {sup 238}Pu source amounted to 17.5 keV at a generator peak width of 7.8 keV. In the measurements on a {sup 226}Ra source, detectors showed linear response and nearly 100% charge collection efficiency at reverse bias above 65 V for all energies of α particles emitted from the source. Tests for thermal stability showed that the proposed detectors can be used in alpha-spectrometry of radionuclides at temperatures up to 120°C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of actinide-fission product yields in Caliban and Prospero metallic core reactor fission neutron fields

In the 1970's and early 1980's, an experimental program was performed on the facilities of the CEA Valduc Research Center to measure several actinide-fission product yields. Experiments were, in particular, completed on the Caliban and Prospero metallic core reactors to study fission-neutron-induced reactions on {sup 233}U, {sup 235}U, and {sup 239}Pu. Thick actinide samples were irradiated and the number of nuclei of each fission product was determined by gamma spectrometry. Fission chambers were irradiated simultaneously to measure the numbers of fissions in thin deposits of the same actinides. The masses of the thick samples and the thin deposits were determined by mass spectrometry and alpha spectrometry. The results of these experiments will be fully presented in this paper for the first time. A description of the Caliban and Prospero reactors, their characteristics and performances, and explanations about the experimental approach will also be given in the article. A recent work has been completed to analyze and reinterpret these measurements and particularly to evaluate the associated uncertainties. In this context, calculations have also been carried out with the Monte Carlo transport code Tripoli-4, using the published benchmarked Caliban description and a three-dimensional model of Prospero, to determine the average neutron energy causing fission. Simulation results will be discussed in this paper. Finally, new fission yield measurements will be proposed on Caliban and Prospero reactors to strengthen the results of the first experiments. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of Uranium Measurements in Water by Various Methods - 13571

In December 2000, EPA amended its drinking water regulations for radionuclides by adding a Maximum Contaminant Level (MCL) for uranium (so called MCL Rule)[1] of 30 micrograms per liter (μg/L). The MCL Rule also included MCL goals of zero for uranium and other radionuclides. Many radioactively contaminated sites must test uranium in wastewater and groundwater to comply with the MCL rule as well as local publicly owned treatment works discharge limitations. This paper addresses the relative sensitivity, accuracy, precision, cost and comparability of two EPA-approved methods for detection of total uranium: inductively plasma/mass spectrometry (ICP-MS) and alpha spectrometry. Both methods are capable of measuring the individual uranium isotopes U-234, U- 235, and U-238 and both methods have been deemed acceptable by EPA. However, the U-238 is by far the primary contributor to the mass-based ICP-MS measurement, especially for naturally-occurring uranium, which contains 99.2745% U-238. An evaluation shall be performed relative to the regulatory requirement promulgated by EPA in December 2000. Data will be garnered from various client sample results measured by ALS Laboratory in Fort Collins, CO. Data shall include method detection limits (MDL), minimum detectable activities (MDA), means and trends in laboratory control sample results, performance evaluation data for all methods, and replicate results. In addition, a comparison will be made of sample analyses results obtained from both alpha spectrometry and the screening method Kinetic Phosphorescence Analysis (KPA) performed at the U.S. Army Corps of Engineers (USACE) FUSRAP Maywood Laboratory (UFML). Many uranium measurements occur in laboratories that only perform radiological analysis. This work is important because it shows that uranium can be measured in radiological as well as stable chemistry laboratories and it provides several criteria as a basis for comparison of two uranium test methods. This data will indicate which test method is the most accurate and most cost effective. This paper provides a benefit to Formerly Utilized Sites Remedial Action Program (FUSRAP) and other Department of Defense (DOD) programs that may be performing uranium measurements. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

241Am (n,gamma) isomer ratio measurement

The objective of this project is to improve the accuracy of the {sup 242}Cm/{sup 241}Am radiochemistry ratio. We have performed an activation experiment to measure the {sup 241}Am(n,{gamma}) cross section leading to either the ground state of {sup 242g}Am (t{sub 1/2} = 16 hr) which decays to {sup 242}Cm (t{sub 1/2} = 163 d) or the long-lived isomer {sup 242m}Am (t{sub 1/2} = 141 yr). This experiment will develop a new set of americium cross section evaluations that can be used with a measured {sup 242}Cm/{sup 241}Am radiochemical measurement for nuclear forensic purposes. This measurement is necessary to interpret the {sup 242}Cm/{sup 241}Am ratio because a good measurement of this neutron capture isomer ratio for {sup 241}Am does not exist. The targets were prepared in 2007 from {sup 241}Am purified from LANL stocks. Gold was added to the purified {sup 241}Am as an internal neutron fluence monitor. These targets were placed into a holder, packaged, and shipped to Forschungszentrum Karlsruhe, where they were irradiated at their Van de Graff facility in February 2008. One target was irradiated with {approx}25 keV quasimonoenergetic neutrons produced by the {sup 7}Li(p,n) reaction for 3 days and a second target was also irradiated for 3 days with {approx}500 keV neutrons. Because it will be necessary to separate the {sup 242}Cm from the {sup 241}Am in order to measure the amount of {sup 242}Cm by alpha spectrometry, research into methods for americium/curium separations were conducted concurrently. We found that anion exchange chromatography in methanol/nitric acid solutions produced good separations that could be completed in one day resulting in a sample with no residue. The samples were returned from Germany in July 2009 and were counted by gamma spectrometry. Chemical separations have commenced on the blank sample. Each sample will be spiked with {sup 244}Cm, dissolved and digested in nitric acid solutions. One third of each sample will be processed at a time. First, the gold will be removed by anion exchange chromatography. Then the {sup 242}Cm will be separated from the {sup 241}Am using the methanol/nitric acid anion exchange method. When a sufficient separation has been achieved, a deposit will be prepared and the {sup 242}Cm will be counted by alpha spectrometry. The purified {sup 241}Am fraction containing the long lived {sup 242m}Am will be allowed to decay into {sup 242}Cm for a period of {approx}6 months. After this time, the americium/curium separations will be repeated and the {sup 242}Cm that has grown in will be counted by alpha spectrometry. At the conclusion of the experiment, we will have cross section measurements for {sup 241}Am (n,{gamma}) {sup 242g}Am and {sup 241}Am (n,V) {sup 242m}Am at two energies.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

In-Field Alpha Spectrometer Development FY2022 Mid-Year Report

In response to needs identified by the International Atomic Energy Agency (IAEA), Idaho National Laboratory (INL) has developed an In-Field Alpha Spectrometer (IFAS) to allow IAEA safeguards inspectors to collect samples of uranium hexafluoride (UF 6 ) at processing facilities, to perform field assessments to verify uranium enrichment. For sample collection, the IFAS method uses Single-Use Destructive Assay (SUDA) samplers, developed at Pacific Northwest National Laboratory (PNNL), which contain thin zeolite coatings that trap UF6 gas and convert it to the safer, more stable form uranyl fluoride (as a dihydrate, UO 2 F 2 ·2H 2 O). For alpha spectrometry, the IFAS instrument employs a large area silicon semiconductor transducer to detect and record alpha particle energy-deposition events. Over the course of this project INL, PNNL, Oak Ridge National Laboratory worked to optimize the SUDA sample design for alpha spectrometry, to optimize processes for manufacturing, loading, and shipping SUDA samples, and to allow the measurement of loaded SUDA samples. In fiscal year (FY) 2022 INL has bene investigating the reproducibility and measurement precision of IFAS measurements and the associated determination of uranium enrichment.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Alpha spectrometric characterization of process-related particle size distributions from active particle sampling at the Los Alamos National Laboratory uranium foundry

Uranium particles within the respirable size range pose a significant hazard to the health and safety of workers. Significant differences in the deposition and incorporation patterns of aerosols within the respirable range can be identified and integrated into sophisticated health physics models. Data characterizing the uranium particle size distribution resulting from specific foundry-related processes are needed. Using personal air sampling cascade impactors, particles collected from several foundry processes were sorted by activity median aerodynamic diameter onto various Marple substrates. After an initial gravimetric assessment of each impactor stage, the substrates were analyzed by alpha spectrometry to determine the uranium content of each stage. Alpha spectrometry provides rapid nondestructive isotopic data that can distinguish process uranium from natural sources and the degree of uranium contribution to the total accumulated particle load. In addition, the particle size bins utilized by the impactors provide adequate resolution to determine if a process particle size distribution is: lognormal, bimodal, or trimodal. Data on process uranium particle size values and distributions facilitate the development of more sophisticated and accurate models for internal dosimetry, resulting in an improved understanding of foundry worker health and safety.

36 MATERIALS SCIENCE↗

Rapid method to determine Polonium-210 in urban matrices

A rapid technique for the determination of polonium-210 in urban matrices has been developed that can be used following a radiological event. Samples such as concrete, soil and granite are fused with sodium hydroxide to minimize polonium volatility during sample digestion and to achieve complete sample dissolution. Complete dissolution of samples is vital to ensure method ruggedness. Polonium is concentrated and separated from the sample matrix using an iron hydroxide precipitation and extraction chromatography and subsequently measured by alpha spectrometry following microprecipitation with bismuth phosphate. The chromatographic separation removes alpha emitting interferences and matrix constituents which can adversely impact the measurement via alpha spectrometry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rapid determination of 210 Po in water samples

A new rapid method for the determination of 210 Po in water samples has been developed at the Savannah River National Laboratory (SRNL) that can be used for emergency response or routine water analyses. If a radiological dispersive device (RDD) event or a radiological attack associated with drinking water supplies occurs, there will be an urgent need for rapid analyses of water samples, including drinking water, ground water and other water effluents. Current analytical methods for the assay of 210 Po in water samples have typically involved spontaneous auto-deposition of 210 Po onto silver or other metal disks followed by counting by alpha spectrometry. The auto-deposition times range from 90 minutes to 24 hours or more, at times with yields that may be less than desirable. If sample interferences are present, decreased yields and degraded alpha spectrums can occur due to unpredictable thickening in the deposited layer. Separation methods have focused on the use of Sr Resin, often in combination with 210 Pb analysis. A new rapid method for 210 Po in water samples has been developed at the Savannah River National Laboratory (SRNL) that utilizes a rapid calcium phosphate co-precipitation method, separation using DGA Resin (N,N,N,N-tetraoctyldiglycolamide extractant-coated resin, Eichrom Technologies or Triskem-International), followed by rapid microprecipitation of 210 Po using bismuth phosphate for counting by alpha spectrometry. This new method can be performed quickly with excellent removal of interferences, high chemical yields and very good alpha peak resolution, eliminating any potential problems with the alpha source preparation for emergency or routine samples. A rapid sequential separation method to separate 210 Po and actinide isotopes was also developed. This new approach, rapid separation with DGA Resin plus microprecipitation for alpha source preparation, is a significant advance in radiochemistry for the rapid determination of 210 Po.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Novel rapid oxidizing fusion method to determine Polonium-210 in air filters

A rapid method for the determination of polonium-210 in air filters has been created for use following a radiological event and for routine environmental monitoring. Air filter samples, including cellulose and glass fiber, are fused with a sodium or potassium nitrate/sodium hydroxide flux material. The alkaline matrix minimizes polonium volatility during sample digestion steps, while efficiently dissolving the air filter and inorganic matter implanted on the filter. The addition of nitrate to the flux destroys organic material which can decrease Polonium recovery during precipitation, extraction and source preparation steps. Polonium is concentrated and separated from the sample matrix using an iron hydroxide precipitation and extraction chromatography with DGA Resin. Polonium-210 is subsequently measured by alpha spectrometry following rapid microprecipitation with bismuth phosphate. The new method employs extraction chromatographic purification to remove alpha emitting interferences and sample matrix constituents which can interfere with 210 Po measurements using alpha spectrometry. The novel blend of sodium hydroxide and alkali metal nitrate digests the air filters quickly and effectively.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurement of Actinides in Molybdenum-99 Solution Analytical Procedure

This document is a companion report to a previous report, PNNL 24519, Measurement of Actinides in Molybdenum-99 Solution, A Brief Review of the Literature, August 2015. In this companion report, we report a fast, accurate, newly developed analytical method for measurement of trace alpha-emitting actinide elements in commercial high-activity molybdenum-99 solution. Molybdenum-99 is widely used to produce 99m Tc for medical imaging. Because it is used as a radiopharmaceutical, its purity must be proven to be extremely high, particularly for the alpha emitting actinides. The sample of 99 Mo solution is measured into a vessel (such as a polyethylene centrifuge tube) and acidified with dilute nitric acid. A gadolinium carrier is added (50 µg). Tracers and spikes are added as necessary. Then the solution is made strongly basic with ammonium hydroxide, which causes the gadolinium carrier to precipitate as hydrous Gd(OH) 3 . The precipitate of Gd(OH) 3 carries all of the actinide elements. The suspension of gadolinium hydroxide is then passed through a membrane filter to make a counting mount suitable for direct alpha spectrometry. The high-activity 99 Mo and 99m Tc pass through the membrane filter and are separated from the alpha emitters. The gadolinium hydroxide, carrying any trace actinide elements that might be present in the sample, forms a thin, uniform cake on the surface of the membrane filter. The filter cake is first washed with dilute ammonium hydroxide to push the last traces of molybdate through, then with water. The filter is then mounted on a stainless steel counting disk. Finally, the alpha emitting actinide elements are measured by alpha spectrometry.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Rapid fusion method for the determination of Pu, Np, and Am in large soil samples

A new rapid sodium hydroxide fusion method for the preparation of 10-20 g soil samples has been developed by the Savannah River National Laboratory (SRNL). The method enables lower detection limits for plutonium, neptunium, and americium in environmental soil samples. The method also significantly reduces sample processing time and acid fume generation compared to traditional soil digestion techniques using hydrofluoric acid. Ten gram soil aliquots can be ashed and fused using the new method in 1-2 hours, completely dissolving samples, including refractory particles. Pu, Np and Am are separated using stacked 2mL cartridges of TEVA and DGA Resin and measured using alpha spectrometry. The method can be adapted for measurement by inductively-coupled plasma mass spectrometry (ICP-MS). Two 10 g soil aliquots of fused soil may be combined prior to chromatographic separations to further improve detection limits. Total sample preparation time, including chromatographic separations and alpha spectrometry source preparation, is less than 8 hours.

54 ENVIRONMENTAL SCIENCES↗

DETERMINATION OF 237NP AND PU ISOTOPES IN LARGE SOIL SAMPLES BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

A new method for the determination of {sup 237}Np and Pu isotopes in large soil samples has been developed that provides enhanced uranium removal to facilitate assay by inductively coupled plasma mass spectrometry (ICP-MS). This method allows rapid preconcentration and separation of plutonium and neptunium in large soil samples for the measurement of {sup 237}Np and Pu isotopes by ICP-MS. {sup 238}U can interfere with {sup 239}Pu measurement by ICP-MS as {sup 238}UH{sup +} mass overlap and {sup 237}Np via {sup 238}U peak tailing. The method provides enhanced removal of uranium by separating Pu and Np initially on TEVA Resin, then transferring Pu to DGA resin for additional purification. The decontamination factor for removal of uranium from plutonium for this method is greater than 1 x 10{sup 6}. Alpha spectrometry can also be applied so that the shorter-lived {sup 238}Pu isotope can be measured successfully. {sup 239}Pu, {sup 242}Pu and {sup 237}Np were measured by ICP-MS, while {sup 236}Pu and {sup 238}Pu were measured by alpha spectrometry.

54 ENVIRONMENTAL SCIENCES↗

Rapid fusion method for determination of plutonium isotopes in large rice samples

A new rapid fusion method for the determination of plutonium in large rice samples has been developed at the Savannah River National Laboratory (Aiken, SC, USA) that can be used to determine very low levels of plutonium isotopes in rice. The recent accident at Fukushima Nuclear Power Plant in March, 2011 reinforces the need to have rapid, reliable radiochemical analyses for radionuclides in environmental and food samples. Public concern regarding foods, particularly foods such as rice in Japan, highlights the need for analytical techniques that will allow very large sample aliquots of rice to be used for analysis so that very low levels of plutonium isotopes may be detected. The new method to determine plutonium isotopes in large rice samples utilizes a furnace ashing step, a rapid sodium hydroxide fusion method, a lanthanum fluoride matrix removal step, and a column separation process with TEVA Resin cartridges. The method can be applied to rice sample aliquots as large as 5 kg. Plutonium isotopes can be determined using alpha spectrometry or inductively-coupled plasma mass spectrometry (ICP-MS). The method showed high chemical recoveries and effective removal of interferences. The rapid fusion technique is a rugged sample digestion method that ensures that any refractory plutonium particles are effectively digested. The MDA for a 5 kg rice sample using alpha spectrometry is 7E-5 mBq g{sup -1}. The method can easily be adapted for use by ICP-MS to allow detection of plutonium isotopic ratios.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Polonium–lead extractions to determine the best method for the quantification of clean lead used in low-background radiation detectors

Very sensitive detectors are used for low-background applications including the detection of environmental radioactivity, double-beta decay, and dark matter. In order to reduce the background noise enough to utilize the sensitivity of these detectors, lead with little or no alpha activity is required to form the shielding. In the past, antiquity lead shielding was used for low-background detectors because lead’s most prominent alpha-emitting isotope, 210Pb, has a short half-life. The microelectronics industry is also greatly affected by alpha activity in lead and solder, and has begun producing “clean” lead for purchase. To quantify how clean the available lead is, 210Pb and, during procedural experiments, a 209Po tracer must be physically or chemically removed from the bulk lead. A reliable procedure for chemical separations that does not use large volumes of ultra-high-purity chemicals has not yet been established. Lead was dissolved and a known amount of 209Po tracer was added. The samples were put through each of two new procedures. The first procedure was based on complete dissolution of the lead followed by a column separation. The second method investigates the utility of a pre-separation step using precipitation of the lead prior to column separation. The resulting solutions were run through strontium resin columns from Eichrom Inc., a United States Transuranium and Uranium Registries (USTUR) electrodeposition procedure, and scheduled to be alpha counted for a minimum of three days. Though neither of the tested procedures had acceptable logistics for large scale implementation, later alpha counting will show which procedure is more promising for further development

Miley, Sarah M↗

High sensitivity measurement of femtogram-level 238 Pu by thermal ionization mass spectrometry with correction of background 238 U

Low-concentration plutonium isotopic measurements provide a valuable fingerprint to identify possible material origins in the context of environmental contamination monitoring, environmental tracing, nuclear safeguards, nuclear forensics, and treaty monitoring. Thermal ionization mass spectrometry (TIMS) has long been recognized as one of the most sensitive techniques for plutonium isotopic measurement, but has not generally been utilized for 238 Pu determination, especially at low concentrations, due to an isobaric interference from 238 U, prevalent as background. Here, this work demonstrates a new analytical technique for correction of background 238 U from the 238 Pu counts collected during a TIMS analysis. The technique takes advantage of the higher ionization temperature of U relative to Pu and uses a 235 U tracer added after plutonium purification chemistry for 238 U semi-quantitative determination. This technique has been successfully applied to the determination of 238 Pu concentration and the 238 Pu/ 239 Pu ratio in sample types including single-isotope standards, isotopic certified reference materials, matrix-containing environmental reference materials, and simulated nuclear detonation debris. The results have been directly compared on a sample-by-sample basis to alpha spectrometry results. The detection limit by this new technique is 0.23 fg 238 Pu, which was previously unachievable by mass spectrometry and is possible in around 1 h of analysis time post-chemistry compared to weeks of required counting time by alpha spectrometry (at the same atom amount). We also present original, high precision data for Pu isotope concentrations in IAEA-384, Fangataufa Sediment, including 242 Pu results for the first time. The new technique allows measurement of a key isotope, 238 Pu, that was previously not measured in small environmental or nuclear forensics collections.

238Pu↗

Effects of the background electrolyte on Th(IV) sorption to muscovite mica

The adsorption of tetravalent thorium on the muscovite mica (001) basal plane was studied by X-ray crystal truncation rod (CTR), and resonant anomalous X-ray reflectivity (RAXR) measurements and alpha spectrometry in the presence of perchlorate background electrolytes LiClO 4 , NaClO 4 , and KClO 4 ([Th(IV)] = 0.1 mM, I = 0.1 M or 0.01 M, pH = 3.3 ± 0.3). RAXR data directly reveal a strong influence of the background electrolyte on the actinide sorption. No significant Th adsorption was observed in 0.1 M NaClO 4 , i.e., the Th coverage θ(Th), the number of Th per unit cell area of the muscovite surface (A UC = 46.72 Å 2 ), was ≤ 0.01 Th/A UC , whereas limited uptake (θ(Th) ~ 0.04 Th/A UC ) was detected at a lower ionic strength (I = 0.01 M). These results are in stark contrast to the behavior of Th in 0.1 M NaCl which showed a coverage of 0.4 Th/A UC (Schmidt et al., 2012a). Th uptake was also influenced by the electrolyte cation. Weak adsorption was observed in 0.1M KClO 4 (θ(Th) ~ 0.07 Th/AUC) similar to the results in NaClO 4 at lower ionic strength. In contrast, strong adsorption was found in 0.1 M LiClO 4 , with θ(Th) = 4.9 Th/A UC , a ~10-fold increase compared with that previously reported in NaCl. These differences are confirmed independently by ex situ alpha spectrometry, which shows no measurable Th coverage in 0.1 M NaClO 4 background in contrast to a large coverage of 1.6 Th/A UC in 0.1 M LiClO 4 . The CTR/RAXR analyses of Th-LiClO 4 show the sorption structure consisting of Th species that are broadly distributed, centered at heights of 4.1 Å and 29 Å distance from the interface. Neither the very large distribution height of the second species nor the high coverage can be explained with (hydrated) ionic adsorption, suggesting that the enhanced uptake is presumably due to the formation and sorption of Th nanoparticles.

interfacial reactivity↗

Deliverable for FαST project: Ln Resin based PLE

This memo describes the fabrication of a polymer ligand extractant based on Eichrom's LN-1 resin. This work has been in support of the Fast Alpha Spectrometry Tool (FαST) project. The first part of LANL's role in this project is to evaluate new extractants for use in polymer ligand extractants (PLEs). The first new extractant evaluated is Di(2-ethyl hexyl) phosphoric acid (HDEHP), which is an effective metal extractant. It has very efficient chelating properties for a wide variety of metal ions. HDEHP is an amphiphillic molecule with two long hydrocarbon chains and a polar end with a phosphoryl oxygen (P=O) and an acidic -OH group as shown in Figure 1. HDEHP has shown effectiveness in extracting lanthanides, selective actinides, and other trivalent elements. Several authors have reported that lanthanides and elements with +3 oxidation state have similar extraction behavior in nitric acid. The distribution ratio for lanthanides rapidly decreases at lower nitric concentration then start to increase at higher concentration as shown in. The trivalent americium, curium, and yttrium exhibit similar trend as trivalent lanthanides. This extraction trend can be also observed from hydrogen chloride solution. This work describes the use of this ligand in a PLE to extract plutonium from solution. Polymer ligand films were prepared by dissolving HDEHP ligands and polystyrene beads in THF. The solution was directly deposited onto a 40 mm diameter stainless steel substrate using an automated pipette. HDEHP based PLEs with direct stippling method are shown in Figure 2. The solution was air dried at room temperature overnight to ensure complete evaporation of THF. The plutonium tracer solution was prepared in 0.01, 0.1, 1, and 8M nitric solutions to study the effect of nitric concentration in plutonium extraction. 0.1667 Bq 239 Pu tracer solution was directly stippled on each PLE and was allowed to equilibrate for 3 hours before removing the solution. The plutonium activity of each sample was measured by direct alpha counting to quantify the plutonium recovery by HDEHP PLE. The alpha spectra from alpha spectroscopy are shown in Figure 3. 1:5, 1:10, and 1:20 PLEs had sharp peak with low tailing. 1:2 had an extremely long tail, which is a possible indication that a large amount of ligands caused the film to not form a smooth surface. Also, it can be noted that 1:2 ratio PLE surface was not as rigid as the other ratio PLEs and it was prone to scratching during sample handing. The resolution of alpha spectra was quantified by measuring Full Width at Half of the Maximum (FWHM) using Bortels equation. The tailing component of the peak was also measured along with FWHM. The peak resolutions and tailing measurements for 0.1M nitric solution samples are given in Table 1. The best resolution was achieved with 1:5 PLE and worst was given by 1:2 PLE. The plutonium recovery by HDEHP PLE was dependent on both nitric concentration and ligand to polymer ratio. 1:2 PLE consistently had the highest recovery followed by 1:5 as shown in Figure 4. It should be noted that 1:2 ratio PLEs consistently had long tailing and the ROI of the spectrum had to be increased to encompass total counts from the tracer. 1:10 and 1:20 PLEs had close to zero percent recovery in all nitric concentration except for 0.01M. The highest plutonium recovery was observed for 0.1M nitric acid. 1:5 PLE gave the best combination of alpha spectroscopy resolution and plutonium recovery. Radiography image of samples were generated to study the plutonium distribution on the PLE surface. Samples were placed on an imaging plate (Fujifilm BAS-TR 2025) for 24 hours and the plate was scanned using GE Typhoon FLA 7000 system. The radiography image in Figure 5 shows uneven distribution with hot spots along the edge and in the center of the samples. These hot spots may be the result of highly localized concentration of ligands or surface defects that were observed in SEM. This unevenness in distribution may cause inaccurate activity measurement by alpha spectroscopy due to a bias in the energy calibration. PLEs based on HDEHP have been evaluated. The concentration of ligand in polystyrene is critical in the performance of the PLE; both for extraction efficiency as well as for alpha spectrometry results. The optimal PLE using this ligand has a concentration of 1:5 ligand to polystyrene. Under laboratory conditions, this configuration can produce similar results to those obtained for DIPEX based PLEs from previous studies. The concentration is very important to the results obtained for this ligand. This PLE is a good candidate for use in later field studies. Our next report will detail the evaluation of PLEs utilizing crown ether ligands.

36 MATERIALS SCIENCE↗

Characterization of 235 U, 238 U and 239 Pu fission ionization chamber foils by α and γ -ray spectrometry

The masses of thin, electroplated deposits of 235 U, 238 U and 239 Pu on titanium backings have been determined to better than 1.3% precision by employing three complementary measurement techniques: $\alpha$ spectrometry, 2$\pi$ gas counting, and $\gamma$-ray spectrometry. A dedicated $\alpha$ spectrometer was designed and calibrated to allow for repeatable, high-precision measurements of the absolute $\alpha$ activity of a sample. The isotopic composition of the sample was determined by fitting the peaks in the $\alpha$ spectrum, a technique which was demonstrated to be generally consistent with mass spectrometry. Independently, the total activity of the deposits were measured in a 2$\pi$ gas flow proportional counter. A detailed study of the effects of $\alpha$ particle straggling in the actinide deposit and $\alpha$ particle recoil off the sample backing material was performed. The masses of these actinide deposits were also measured via $\gamma$-ray spectrometry. Here, we found that all three systematically independent techniques produced consistent results, and could be combined into a weighted average with further reduced uncertainty. The mass ratios of these actinide deposits were determined to better than 1% precision via $\alpha$ spectrometry, enabling high-precision fission cross section ratio measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗