Search NASA⌕ Search

SEARCH · Search NASA

Results for “Alpha counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

40 records · Page 3

Prompt Gamma Analysis of ARIES Materials and Updates to the 2015 Calibration Equations

Prompt gamma (PG) analysis is a nondestructive, nuclear, elemental analysis technique that uses charged particle reactions to interrogate a sample, and elements present in the sample matrix are identified through the characteristic gamma-rays emitted from the product nuclei in alpha-p and alpha-n nuclear reactions. This technique has been applied to plutonium oxide packaged in over 4,000 individual 3013 containers, and the concentrations of certain light elements were determined from the integrated peak areas based on a calibration that was published previously. This report provides the results for a new population of 3013 containers packaged with oxide materials produced by the conversion of metal by Advanced Recovery and Integrated Extraction System (ARIES) project using the direct metal oxidation (DMO) process and muffle furnaces. New PG and analytical chemistry data collected since 2015 were added to the existing calibration data sets to refine the calibration parameters. Calibration equations were also developed for determining beryllium and fluorine at low concentrations in high-purity ARIES product oxides. The new fluorine calibration provides an order of magnitude greater sensitivity and results in an additional 1,408 containers in the original population identified as having fluorine as an impurity. Additionally, equations for calculating the lower limits of detection (LLDs) as a function of the actual counting time (live time) were obtained using WLS regression technique for samples in the calibration data set. This resulted in changes to the LLDs published previously.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of material isotopics and atom number ratio with α-particle spectroscopy for a NIFFTE fission Time Projection Chamber actinide target

In this work, we present the results of a measurement of isotopic concentrations and atomic number ratio of a double-sided actinide target using α-spectroscopy and mass spectrometry. The double-sided actinide target, with predominantly 239 Pu on one side and 235 U on the other, was used in the fission Time Projection Chamber (fissionTPC) for a measurement of the neutron-induced fission cross-section ratio between the two isotopes. The measured atomic number ratio is needed to extract an absolute measurement fission cross-section ratio. The 239 Pu/ 235 U atom number ratio was measured with a combination of mass spectrometry and α-spectroscopy with a planar silicon detector achieving uncertainties of less than 1%. Different strategies for estimating isotopic concentration from the α-spectrum are presented to demonstrate the potential of these methods for non-destructive target assay. We found that a combination of fitting spectra with constraints from mass spectrometry, and summing counts in a region of the spectrum provided the most consistent results with the lowest uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

Combining Planck and SPT Cluster Catalogs: Cosmological Analysis and Impact on the Planck Scaling Relation Calibration

We provide the first combined cosmological analysis of the South Pole Telescope (SPT) and Planck cluster catalogs. The aim is to provide an independent calibration for Planck scaling relations, exploiting the cosmological constraining power of the SPT-SZ cluster catalog and its dedicated weak lensing (WL) and X-ray follow-up observations. We build a new version of the Planck cluster likelihood. In the νΛ CDM scenario, focusing on the mass slope and mass bias of Planck scaling relations, we find ${\alpha }_{\mathrm{SZ}}={1.49}_{-0.10}^{+0.07}$ and ${\left(1-b\right)}_{\mathrm{SZ}}={0.69}_{-0.14}^{+0.07}$, respectively. The results for the mass slope show a ~4 σ departure from the self-similar evolution, α SZ ~ 1.8. This shift is mainly driven by the matter density value preferred by SPT data, Ωm = 0.30 ± 0.03, lower than the one obtained by Planck data alone, ${{\rm{\Omega }}}_{m}={0.37}_{-0.06}^{+0.02}$. The mass bias constraints are consistent both with outcomes of hydrodynamical simulations and external WL calibrations, (1 – b) ~ 0.8, and with results required by the Planck cosmic microwave background cosmology, (1 – b) ~ 0.6. From this analysis, we obtain a new catalog of Planck cluster masses M 500 . We estimate the ratio between the published Planck M SZ masses and our derived masses M 500 , as a "measured mass bias," ${\left(1-b\right)}_{M}$. We analyze the mass, redshift, and detection noise dependence of ${\left(1-b\right)}_{M}$, finding an increasing trend toward high redshift and low mass. These results mimic the effect of departure from self-similarity in cluster evolution, showing different dependencies for the low-mass, high-mass, low-z, and high-z regimes.

79 ASTRONOMY AND ASTROPHYSICS↗