Search NASA⌕ Search

SEARCH · Search NASA

Results for “Alternating minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Increasing the efficiency of a carbon dioxide refrigeration system using a pressure exchanger

Natural refrigerants such as carbon dioxide (R744) are gaining increased interest as industry searches for alternatives with minimal environmental impacts. However, R744-based systems have lower operating efficiencies as compared to hydrofluorocarbon-based systems, particularly in hot climates. Implementing pressure exchanger (PX) technology may enable R744 systems to operate over a broader range of operating temperatures. A PX consists of narrow longitudinal channels positioned radially around a rotating cylinder. High- and low-pressure fluids flow into the PX and exchange pressure, creating an intermediate-pressure flow. In this paper, the design of the PX will be discussed, and a model of the PX will be developed. Refrigeration system designs implementing the PX will be presented. It will be shown that the PX has the potential to boost the coefficient of performance (COP) of R744 systems by over 25% compared to standard transcritical R744 booster systems.

Fricke, Brian↗

Measuring solar reflectance - Part II: Review of practical methods

A companion article explored how solar reflectance varies with surface orientation and solar position, and found that clear sky air mass 1 global horizontal (AM1GH) solar reflectance is a preferred quantity for estimating solar heat gain. In this study we show that AM1GH solar reflectance R{sub g,0} can be accurately measured with a pyranometer, a solar spectrophotometer, or an updated edition of the Solar Spectrum Reflectometer (version 6). Of primary concern are errors that result from variations in the spectral and angular distributions of incident sunlight. Neglecting shadow, background and instrument errors, the conventional pyranometer technique can measure R{sub g,0} to within 0.01 for surface slopes up to 5:12 [23 ], and to within 0.02 for surface slopes up to 12:12 [45 ]. An alternative pyranometer method minimizes shadow errors and can be used to measure R{sub g,0} of a surface as small as 1 m in diameter. The accuracy with which it can measure R{sub g,0} is otherwise comparable to that of the conventional pyranometer technique. A solar spectrophotometer can be used to determine R{sub g,0}{sup *}, a solar reflectance computed by averaging solar spectral reflectance weighted with AM1GH solar spectral irradiance. Neglecting instrument errors, R{sub g,0}{sup *} matches R{sub g,0} to within 0.006. The air mass 1.5 solar reflectance measured with version 5 of the Solar Spectrum Reflectometer can differ from R{sub g,0}{sup *} by as much as 0.08, but the AM1GH output of version 6 of this instrument matches R{sub g,0}{sup *} to within about 0.01. (author)

14 SOLAR ENERGY↗

Aneurysm Sac Pressure Measurement with Minimally Invasive Implantable Pressure Sensors: An Alternative to Current Surveillance Regimes after EVAR?

Current protocols for surveillance after endovascular repair (EVAR) of abdominal aortic aneurysms are mostly based on costly and time-consuming imaging procedures and aim to detect adverse events such as graft migration, endoleaks or aneurysm sac enlargement. These imaging procedures are either associated with radiation exposure to the patients or may be harmful to the patient due to the use of iodine- or gadolinium-containing contrast agents. Furthermore the advantages of EVAR in the short term might be negated by the necessity for endograft surveillance over years. Thus, alternative modalities for follow-up are being investigated. One of these technologies provides pressure information directly from the aneurysm sac. This noninvasive, telemetric pressure sensing was tested in vitro as well as in first clinical trials and was able to identify successful aneurysm exclusion after EVAR. The telemetric pressure sensors showed a promising efficacy and accuracy in detecting type I and type III endoleaks and will help to clarify the clinical relevance of type II endoleaks. This article provides an overview of the in vitro sensors investigated as well as the first clinical trials and the sensors' potential to change the current endograft surveillance regimes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Applying an improved rapid impact assessment matrix method to strategic environmental assessment of urban planning in China

Strategic environmental assessment (SEA) has become an increasingly important decision-support tool for providing information on the environmental implications of a policy, plan, or program. The goal is to safeguard the environment and promote sustainable development at the strategic level. Despite major progress in implementing SEA practices internationally, developing countries, such as China, often lag behind in applying SEA methodology. Lack of available data and time constraints arising from tight schedules create problems. The rapid impact assessment matrix (RIAM) is a potential resource for breaking through such difficulties. Our analysis of RIAM applications suggested that it could become a tool for evaluating strategic alternatives because of its applicability in interdisciplinary settings, its transparency, and its short implementation timeframe. To make it more suitable for the SEA context, we have developed two major improvements to the conventional RIAM process: assignment of weights to assessment indicators and the development of an integrated environmental assessment score (IES). The improved RIAM process was employed in an SEA of the development plan for the Nansha District in Guangzhou, the capital city of Guangdong Province in China. It was used to assess five alternatives for development in Wanqingsha (WQS), a subunit of Nansha, where important ecological resources are located and where industrial development could impact the air quality in the neighboring Hong Kong Special Administrative Region (HKSAR). The evaluation identified WQS-A04 as the preferred alternative. This alternative involved a minimal amount of industrial development – 10% compared with the most intense development alternative – and included important wetland preservation plans. The assessment results have been incorporated into the officially approved development plan for Nansha. The improved RIAM methodology is well adapted to the technical aims of SEA and decision-making structures in China. It offers the potential for delivering timely and quality results to decision-making processes. To achieve the desired efficiency, it is recommended that an SEA procedure take into account findings acquired from an improved RIAM application at an early stage, then, at a later stage, results from more comprehensive assessments conducted using more sophisticated methods should be added, if time and data are available. - Highlights: • RIAM is a potential SEA tool due to its multidisciplinary setting and rapid process. • Weighting index and computing IES are raised for improving RIAM when applied to SEAs. • The improved RIAM boosts SEA effectiveness by timely responding to decision-making. • The improved RIAM is more suitable to an SEA bothered by tight time or data shortage. • The improved RIAM adapts to the technical aims of SEA and decision features in China.

54 ENVIRONMENTAL SCIENCES↗

BNNT-mediated irreversible electroporatio: its potential on cancer cells

Tissue ablation, i.e., the destruction of undesirable tissues, has become an important minimally invasive technique alternative to resection surgery for the treatment of tumours. Several methods for tissue ablation are based on thermal techniques using cold, e.g. cryosurgery [1] or heat, e.g. radiofrequency [2] or high-intensity focused ultrasound [3] or nanoparticle-mediated irradiation [4]. Alternatively, irreversible electroporation (IRE) has been proposed as non thermal technique for minimally invasive tissue ablation based on the use of electrical pulses. When the electric field is applied to a cell, a change in transmembrane potential is induced, which can cause biochemical and physiological changes of the cell. When the threshold value of the transmembrane potential is exceeded, the cell membrane becomes permeable, thus allowing entrance of molecules that otherwise cannot cross the membrane [5]. A further increase in the electric field intensity may cause irreversible membrane permeabilization and cell death. These pulses create irreversible defects (pores) in the cell membrane lipid bilayer, causing cell death through loss of cell homeostasis [6]. This is desirable in tumour ablation in order to produce large cell death, without the use of cytostatic drugs. A study of Davalos, Mir and Rubinsky showed that IRE can ablate substantial volumes of tissue without inducing a thermal effect and therefore serve as an independent and new tissue ablation modality; this opened the way to the use of IRE in surgery [7]. Their finding was subsequently confirmed in studies on cells [8], small animal models [9] and in large animal models in the liver [10] and the heart [11]. The most important finding in these papers is that irreversible electroporation produces precisely delineated ablation zones with cell scale resolution between ablated and non-ablated areas, without zones in which the extent of damage changes gradually as during thermal ablation. Furthermore, it is observed that irreversible electroporation affects only the membrane of living cells and spares the tissues scaffold. The work of Rubinsky et al.[10] was the first to highlight some of the essential clinical features of irreversible electroporation such as the ability to spare large blood vessels and bile ducts, rapid tissue regeneration because of the intact large blood vessels scaffolds, rapid activation of the immune system, no scarring and the potential ability to treat tumours near large blood vessels [12] .

60 APPLIED LIFE SCIENCES↗

A note on minimizing time assurance tests for repairable systems

We consider assurance testing for repairable systems when supplementary information is available in addition to the data collected in the assurance test. Here, the supplementary information is incorporated using a Bayesian inferential framework. Here we consider assurance testing for a homogeneous Poisson process. In this note we consider an alternative criterion that minimizes the test time while ensuring that the requirements on the producer's and consumer's risks are met. We illustrate the use of this alternative criterion with an example.

42 ENGINEERING↗

SU-F-18C-13: Low-Dose X-Ray CT Reconstruction Using a Hybrid First-Order Method

Purpose: To develop a novel reconstruction method for X-ray CT that can lead to accurate reconstruction at significantly reduced dose levels combining low X-ray incident intensity and few views of projection data. Methods: The noise nature of the projection data at low X-ray incident intensity was modeled and accounted by the weighted least-squares (WLS) criterion. The total variation (TV) penalty was used to mitigate artifacts caused by few views of data. The first order primal-dual (FOPD) algorithm was used to minimize TV in image domain, which avoided the difficulty of the non-smooth objective function. The TV penalized WLS reconstruction was achieved by alternated FOPD TV minimization and projection onto convex sets (POCS) for data fidelity constraints. The proposed FOPD-POCS method was evaluated using the FORBILD jaw phantom and the real cadaver head CT data. Results: The quantitative measures, root mean square error (RMSE) and contrast-to-noise ratio (CNR), demonstrate the superior denoising capability of WLS over LS-based TV iterative reconstruction. The improvement of RMSE (WLS vs. LS) is 15%∼21% and that of CNR is 17%∼72% when the incident counts per ray are ranged from 1×10{sup 5} to 1×10{sup 3}. In addition, the TV regularization can accurately reconstruct images from about 50 views of the jaw phantom. The FOPD-POCS reconstruction reveals more structural details and suffers fewer artifacts in both the phantom and real head images. The FOPD-POCS method also shows fast convergence at low X-ray incident intensity. Conclusion: The new hybrid FOPD-POCS method, based on TV penalized WLS, yields excellent image quality when the incident X-ray intensity is low and the projection views are limited. The reconstruction is computationally efficient since the FOPD minimization of TV is applied only in the image domain. The characteristics of FOPD-POCS can be exploited to significantly reduce radiation dose of X-ray CT without compromising accuracy for diagnosis or treatment planning.

60 APPLIED LIFE SCIENCES↗

Magnetic and Mechanical Design of a 15-T Large Aperture Dipole Magnet for Cable Testing

© 2019 IEEE. A large aperture Nb 3 Sn dipole is proposed to replace the magnet assembly of EDIPO, which was irreversibly damaged in 2016. The goal is to generate a background field of 15 T at 4.2 K in a clear aperture of approximately 100×150 mm 2 and over a uniform length of 1000 mm in order to test superconducting cables for both fusion and high-energy physics applications. The magnet features a block-type coil design wound with wide Rutherford cable (two alternative coil cross sections are considered) and supported by a mechanical structure based on keys-and-bladders technology. In the end regions, the coils tilt up (flare) through a hard-way bend of the cables to provide room for the test well, following a layout already adopted in the LBNL HD2 and CERN-CEA FRESCA2 magnets. The two considered coil design alternatives aim at minimizing the mechanical stress in the coil windings. One coil pack design makes the use of two double pancake coils per pole, whereas the other alternative features three double pancakes per pole. Both design options are presented focusing on the results of numerical computations carried out with finite-element models to investigate peak stresses in the coils during room-temperature pre-loading, cool down, and powering.

Sarasola, Xabier (ORCID:0000000324306939)↗

Making tensor factorizations robust to non-gaussian noise.

Tensors are multi-way arrays, and the CANDECOMP/PARAFAC (CP) tensor factorization has found application in many different domains. The CP model is typically fit using a least squares objective function, which is a maximum likelihood estimate under the assumption of independent and identically distributed (i.i.d.) Gaussian noise. We demonstrate that this loss function can be highly sensitive to non-Gaussian noise. Therefore, we propose a loss function based on the 1-norm because it can accommodate both Gaussian and grossly non-Gaussian perturbations. We also present an alternating majorization-minimization (MM) algorithm for fitting a CP model using our proposed loss function (CPAL1) and compare its performance to the workhorse algorithm for fitting CP models, CP alternating least squares (CPALS).

97 MATHEMATICS AND COMPUTING↗

Standard of Practice for the Endovascular Treatment of Thoracic Aortic Aneurysms and Type B Dissections

Thoracic endovascular aortic repair (TEVAR) represents a minimally invasive technique alternative to conventional open surgical reconstruction for the treatment of thoracic aortic pathologies. Rapid advances in endovascular technology and procedural breakthroughs have contributed to a dramatic transformation of the entire field of thoracic aortic surgery. TEVAR procedures can be challenging and, at times, extraordinarily difficult. They require seasoned endovascular experience and refined skills. Of all endovascular procedures, meticulous assessment of anatomy and preoperative procedure planning are absolutely paramount to produce optimal outcomes. These guidelines are intended for use in quality-improvement programs that assess the standard of care expected from all physicians who perform TEVAR procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Kinetic Consequences of Water on Catalytic Methane Pyrolysis

Hydrogen production from biomass and natural gas has emerged as a prominent research area in response to the growing demand for energy from alternative sources that minimize CO 2 emissions. In this study, we investigate the impact of water, which is present in and generated from biomass-derived streams, on carbon nanotube (CNT) growth and hydrogen production during methane decomposition using Ni–Mo/MgO as a catalyst. We reveal here that the role of water on CNT growth is highly complex; its effect depends on the stage of growth at which the water is incorporated. When water is introduced at the beginning of methane decomposition ( t = 0 h), methane conversion rates are negatively impacted. We hypothesize that water inhibits the significant phase changes the Ni–Mo/MgO catalyst undergoes during catalyst carburization. In contrast, the incorporation of a small percentage of water after a stabilization period ( t = 3 h) results in methane conversion rate enhancements that scale with the introduced water partial pressure as water selectively reacts with amorphous carbon deposits that lead to catalyst deactivation, thus prolonging the lifetime of some of the most active sites. Moreover, water incorporation after stabilization significantly reduces the apparent activation energy. Density Functional Theory (DFT) calculations reveal that water preferentially interacts with carbon fragments on the catalyst surface to remove carbon deposits with a barrier lower than that required for methane activation, further supporting its role in cleaning active sites on the catalyst surface. Characterization of the resulting carbon nanotubes reveals the formation of more graphitic materials produced in the presence of water, highlighting the impact of water on nanotube properties. These results provide clarity toward the many ways in which water, or cofeeding of biomass-derived materials, may impact catalytic methane pyrolysis rates.

carbon nanotubes↗

Technoeconomic and Life Cycle Analysis of an Integrated Fermentation and Microbial Electrochemical Process for Volatile Fatty Acid Production from Food Waste

Techno-economic analysis (TEA) and life cycle assessment (LCA) were conducted for an integrated system designed for the production of volatile fatty acid (VFA) from food waste. The TEA estimated a production cost of $\$$3.12/kg VFA, and the LCA predicted negative greenhouse gas (GHG) emissions of -0.4 kg CO 2 e/kg VFA, driven primarily by diverting organic waste from landfills and avoiding methane emissions while producing valuable chemical products. Hotspot analysis showed arrested methanogenesis (AM) fermentation as the largest contributor to costs (37%) and environmental burden (47%), driven by high sodium hydroxide (NaOH) consumption. Distillation and microbial electrosynthesis (MES) units were the next-largest environmental contributors (28% and 18%). Major cost drivers also included residuals management (biosolids and wastewater) and the equipment and operating costs for AM, MES, and sonication pretreatment units. Although the new integrated system is environmentally benign, its costs and environmental impacts can be further reduced by integrating alternative energy sources, minimizing chemical and energy inputs through process optimization, and improving efficiency. In conclusion, this work highlighted the viability of waste-derived VFA production and provided a clear, data-driven strategy to accelerate the commercialization of waste valorization technology.

Carboxylic Acid Production↗

Visualization of magnetic domains in sculpted three-dimensional cobalt nanospirals

In this work, we report on the direct visualization of magnetic structure in sculpted three- dimensional cobalt (Co) nanospirals with a wire diameter of 20 nm and outer spiral diameter of 115 nm and on the magnetic interactions between the nanospirals, using aberration-corrected Lorentz transmission electron microscopy. By analyzing the magnetic domains in three di- mensions at the nanoscale, we show that magnetic domain formation in the Co nanospirals is a result of the shape anisotropy dominating over the magnetocrystalline anisotropy of the system. We also show that the strong dipolar magnetic interactions between adjacent closely- packed nanospirals leads to their magnetization directions adopting alternating directions to minimize the total magnetostatic energy of the system. Deviations from such magnetization structure can only be explained by analyzing the complex three-dimensional structure of the nanospirals. These nanostructures possess an inherent chirality due to their growth conditions and are of significant importance as nanoscale building blocks in magneto-optical devices. Keywords: Nanomagnetic structure, Nanospiral, 3D nanomagnetism, 3D visualization, Lorentz transmission electron microscopy.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Optimizing the regularization in size-consistent second-order Brillouin-Wigner perturbation theory

Despite its simplicity and relatively low computational cost, second-order Møller-Plesset perturbation theory (MP2) is well-known to overbind noncovalent interactions between polarizable monomers and some organometallic bonds. In such situations, the pairwise-additive correlation energy expression in MP2 is inadequate. Although energy-gap dependent amplitude regularization can substantially improve the accuracy of conventional MP2 in these regimes, the same regularization parameter worsens the accuracy for small molecule thermochemistry and density-dependent properties. Recently, we proposed a repartitioning of Brillouin-Wigner perturbation theory that is size-consistent to second order (BW-s2), and a free parameter ($α$) was set to recover the exact dissociation limit of H 2 in a minimal basis set. Alternatively $α$ can be viewed as a regularization parameter, where each value of $α$ represents a valid variant of BW-s2, which we denote as BW-s2($α$). In this work, we semi-empirically optimize $α$ for noncovalent interactions, thermochemistry, alkane conformational energies, electronic response properties, and transition metal datasets, leading to improvements in accuracy relative to the ab initio parameterization of BW-s2 and MP2. We demonstrate that the optimal $α$ parameter ($α$ = 4) is more transferable across chemical problems than energy-gap-dependent regularization parameters. This is attributable to the fact that the BW-s2($α$) regularization strength depends on all of the information encoded in the t amplitudes rather than just orbital energy differences. While the computational scaling of BW-s2($α$) is iterative $\mathcal{O}$($N^5$), this effective and transferable approach to amplitude regularization is a promising route to incorporate higher-order correlation effects at second-order cost.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Landscape of Supersymmetric Particle Mass Hierarchies and their Signature Space at the CERN Large Hadron Collider

The minimal supersymmetric standard model with soft breaking has a large landscape of supersymmetric particle mass hierarchies. This number is reduced significantly in well-motivated scenarios such as minimal supergravity and alternatives. We carry out an analysis of the landscape for the first four lightest particles and identify at least 16 mass patterns, and provide benchmarks for each. We study the signature space for the patterns at the CERN Large Hadron Collider by analyzing the lepton+ (jet{>=}2) + missing P{sub T} signals with 0, 1, 2, and 3 leptons. Correlations in missing P{sub T} are also analyzed. It is found that even with 10 fb{sup -1} of data a significant discrimination among patterns emerges.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diamond channel-cut crystals for high-heat-load beam-multiplexing narrow-band X-ray monochromators

Next-generation high-brilliance X-ray photon sources call for new X-ray optics. Here we demonstrate the possibility of using monolithic diamond channel-cut crystals as high-heat-load beam-multiplexing narrow-band mechanically stable X-ray monochromators with high-power X-ray beams at cutting-edge high-repetition-rate X-ray free-electron laser (XFEL) facilities. The diamond channel-cut crystals fabricated and characterized in these studies are designed as two-bounce Bragg reflection monochromators directing 14.4 or 12.4 keV X-rays within a 15 meV bandwidth to 57 Fe or 45 Sc nuclear resonant scattering experiments, respectively. The crystal design allows out-of-band X-rays transmitted with minimal losses to alternative simultaneous experiments. Only ≲2% of the incident ∼100 W X-ray beam is absorbed in the 50 µm-thick first diamond crystal reflector, ensuring that the monochromator crystal is highly stable. Other X-ray optics applications of diamond channel-cut crystals are anticipated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

WE-G-207-03: Mask Guided Image Reconstruction (MGIR): A Novel Method for Ultra-Low-Dose 3D and Enhanced 4D Cone-Beam Computer-Tomography

Purpose: Recently, compressed sensing (CS) based iterative reconstruction (IR) method is receiving attentions to reconstruct high quality cone beam computed tomography (CBCT) images using sparsely sampled or noisy projections. The aim of this study is to develop a novel baseline algorithm called Mask Guided Image Reconstruction (MGIR), which can provide superior image quality for both low-dose 3DCBCT and 4DCBCT under single mathematical framework. Methods: In MGIR, the unknown CBCT volume was mathematically modeled as a combination of two regions where anatomical structures are 1) within the priori-defined mask and 2) outside the mask. Then we update each part of images alternatively thorough solving minimization problems based on CS type IR. For low-dose 3DCBCT, the former region is defined as the anatomically complex region where it is focused to preserve edge information while latter region is defined as contrast uniform, and hence aggressively updated to remove noise/artifact. In 4DCBCT, the regions are separated as the common static part and moving part. Then, static volume and moving volumes were updated with global and phase sorted projection respectively, to optimize the image quality of both moving and static part simultaneously. Results: Examination of MGIR algorithm showed that high quality of both low-dose 3DCBCT and 4DCBCT images can be reconstructed without compromising the image resolution and imaging dose or scanning time respectively. For low-dose 3DCBCT, a clinical viable and high resolution head-and-neck image can be obtained while cutting the dose by 83%. In 4DCBCT, excellent quality 4DCBCT images could be reconstructed while requiring no more projection data and imaging dose than a typical clinical 3DCBCT scan. Conclusion: The results shown that the image quality of MGIR was superior compared to other published CS based IR algorithms for both 4DCBCT and low-dose 3DCBCT. This makes our MGIR algorithm potentially useful in various on-line clinical applications. Provisional Patent: UF#15476; WGS Ref. No. U1198.70067US00.

60 APPLIED LIFE SCIENCES↗