Search NASA⌕ Search

SEARCH · Search NASA

Results for “AmBe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

High performance data acquisition, identification, and monitoring for active magnetic bearings

Future active magnetic bearing systems (AMB) must feature easier on-site tuning, higher stiffness and damping, better robustness with respect to undesirable vibrations in housing and foundation, and enhanced monitoring and identification abilities. To get closer to these goals we developed a fast parallel link from the digitally controlled AMB to Matlab, which is used on a host computer for data processing, identification, and controller layout. This enables the magnetic bearing to take its frequency responses without using any additional measurement equipment. These measurements can be used for AMB identification.

Herzog, Raoul↗

Fabrication and Evaluation of Graphite Fiber-Reinforced Polyimide Composite Tube Forms Using Modified Resin Transfer Molding

The techniques necessary for the fabrication of a complex three-dimensional tubular form using a PMR-type resin have been developed to allow for the construction of several tubes with good physical and mechanical properties. Employing established resin transfer molding practices, the relatively non-hazardous AMB-21 in acetone formulation was used to successfully impregnate four layers of AS4 braided graphite fiber preform previously loaded around an aluminum cylindrical core in an enclosed mold cavity. Using heat and vacuum, the solvent was evaporated to form a prepreg followed by a partial imidization and removal of condensation products. The aluminum core was replaced by a silicone rubber bladder and the cure cycle continued to the final stage of 550 F with a bladder internal pressure of 200 lbs/sq in while simultaneously applying a strong vacuum to the prepreg for removal of any additional imidization products. A combination of several modifications to the standard resin transfer molding methodology enabled the mold to 'breathe', allowing the imidization products a pathway for escape. AMB-21 resin was chosen because of the carcinogenic nature of the primary commercial polyimide PMR-15. The AMB-21 resin was formulated using commercially available monomers or monomer precursors and dissolved in a mixture of methyl alcohol and acetone. The viscosity of the resulting monomer solution was checked by use of a Brookfield rheometer and adjusted by adding acetone to an easily pumpable viscosity of about 600 cP. In addition, several types of chromatographic and thermal analyses were of the braids, and excess handling of the preforms broke some of the microscopic fibers, needlessly decreasing the strength of the finished part. In addition, three dimensional braided preforms with fibers along the length of the tube will be significantly stronger in tension than the braided preforms used in this study.

Exum, Daniel B.↗

Low-Cost Production of Composite Bushings for Jet Engine Applications

The objectives of this research program were to reduce the manufacturing costs of variable stator vane bushings by 1) eliminating the expensive carbon fiber braiding operation, 2) replacing the batch mode impregnation, B-stage, and cutting operations with a continuous process, and 3) reducing the molding cycle and machining operations with injection molding to achieve near-net shapes. Braided bushings were successfully fabricated with both AMB-17XLD and AMB-TPD resin systems. The composite bushings achieved high glass transition temperature after post-cure (+300 C) and comparable weight loss to the PNM-15 bushings. ANM-17XLD bushings made with "batch-mode" molding compound (at 0.5 in. fiber length) achieved a +300 lb-force flange break strength which was superior to the continuous braided-fiber reinforced bushing. The non-MDA resin technology developed in this contract appears attractive for bushing applications that do not exceed a 300 C use temperature. Two thermoplastic polyimide resins were synthesized in order to generate injection molding compound powders. Excellent processing results were obtained at injection temperatures in excess of 300 C. Micro-tensile specimens were produced from each resin type and the Tg measurements (by TMA) for these samples were equivalent to AURUM(R). Thermal Gravimetric Analysis (TGA) conducted at 10 C/min showed that the non-MDA AMB-type polyimide thermoplastics had comparable weight loss to PMR-15 up to 500 C.

Gray, Robert A.↗

Effects of Growth Hormone/IGF-I and Exercise on Unloaded Bones

Growth hormone (GH) and insulin-like growth factor-I (IGF-I) in combination with exercise prevent muscle atrophy induced by unloading in the tail-suspension rat model for space flight (Gosselink et al, FASEB J 1994). This study evaluated the effects of these treatments on bone. Hypophysectomized rats were suspended (S) and treated with 1mg/kg/day CH plus IGF-I (H) or vehicle (Sal) daily by injection and exercised (Ex) by 3 climbs up a 1m ladder carrying a load equal to 30% the initial body weight (BW) 3x/day for 10 days. Tibial epiphysis (Epi) widths were measured by micrometry and femoral Bone Mineral Content (fBMC) in excised femurs by DEXA (Lunar DPX-L). Serum calcium (Ca) and phosphorus (Pi) were measured by COBAS Autoanalyzer (Roche Diag.). Ambulatory (Amb)-H treated rats showed growth rates of 6.6+-0.9 g/day, similar to S-H-Ex and higher than S-H (3.210.6, p less than 0.05) and S-Sal (-0.711.0, p less than 0.05). Epi widths were 10% lower in S-Sal, and S-Sal-Ex, and increased 100% in all H groups. fBMC was less in S than Amb, only when all S groups are compared to both Amb groups (p less than 0.03). H treatment increased fBMC (p less than 0.05) but reduced fBMC/100g BW in all H groups (p less than 0.001). The reduced density of H bone cannot be attributed to low circulating Ca. and Pi since they were higher in H than Sal (p less than 0.001). H treatment for 10 days in doses sufficient to support normal growth in BW failed to produce normal Epi widths or fBMC, even when combined with exercise. The suspension effect observed in Epi widths was not corrected by H or Ex alone, but was improved by H plus a This regimen. although effective in preventing muscle atrophy, failed to return bone measures, Epi widths and fBMC, to normal.

Harper, J. S.↗

Pharmacokinetics of Intranasal Scopolamine Gel Formation During Antiorthostatic Bedrest - A Microgravity Analog

Space Motion sickness (SMS) is an age old problem for astronauts on both short and long duration space flights. Scopolamine (SCOP) is the most frequently used drug for the treatment of motion sickness (MS) which is currently available in transdermal patch and tablet dosage forms. These formulations of SCOP are ineffective for the treatment of SMS. Intranasal dosage forms are noninvasive with rapid absorption and enhanced bioavailability thus allowing precise and reduced dosing options in addition to offering rescue and treatment options. As such, an intranasal gel dosage formulation of scopolamine (INSCOP) was developed and Pharmacokinetics (PK) and bioavailability were determined under IND guidelines. The present clinical trial compares PK and bioavailability of INSCOP in 12 normal, healthy subjects (6 male/ 6 female) during ambulation (AMB) and antiorthostatic bedrest (ABR) used as a ground-based microgravity analog. Subjects received 0.2 and 0.4 mg doses of INSCOP during AMB and ABR in a four-way crossover design. Results indicated no difference between AMB and ABR in PK parameters after 0.2 mg dose. Clearance (Cls) decreased with a concomitant increase in maximum concentration and area under concentration versus time curve (AUC) during ABR after the 0.4 mg dose. This difference in AUC and Cls at the higher but not the lower dose during ABR may suggest that ABR may affect metabolism and/or clearance at higher doses of INSCOP. These results indicate that dosing adjustment may be required for treatment of SMS with INSCOP in space.

Lakshmi, Putcha↗

Pharmacokinetics of Intranasal Scopolamine Gel Formulation During Antiorthostatic Bed Rest, a Microgravity Analog

Statement of Purpose, Innovation or Hypothesis: Space Motion sickness (SMS) is a long-standing problem for astronauts on both short and long duration space flights. Scopolamine (SCOP) is frequently used for the treatment of motion sickness (MS), and is available as transdermal patch and tablet dosage forms. These formulations of SCOP are ineffective for the treatment of SMS. Intranasal dosage forms are noninvasive with rapid absorption and enhanced bioavailability, thus allowing precise and reduced dosing in addition to offering rescue and treatment options. An intranasal gel dosage formulation of scopolamine (INSCOP) was developed and pharmacokinetics (PK) and bioavailability were determined in clinical trials with human subjects under IND guidelines.Description of Methods and Materials: The present clinical trial compares PK and bioavailability of INSCOP in 12 normal, healthy subjects (6 male/ 6 female) during ambulation (AMB) and antiorthostaticbed rest (ABR) used as a ground-based microgravity analog. Subjects received 0.2 mg and 0.4 mg doses of INSCOP during AMB and ABR in a 4-way crossover design.Data and Results: Results indicated no difference between AMB and ABR in PK parameters after 0.2 mg dose, Clearance (Cls) decreased with a concomitant increase in maximum concentration and area under concentration-versus-time curve (AUC) during ABR after the 0.4 mg dose.Interpretation, Conclusion or Significance: The difference in AUC and Cls at the higher (0.4 mg) but not the lower dose (0.2 mg) during ABR suggests that ABR may affect metabolism and/or clearance of INSCOP at higher doses . These results indicate that dosing adjustment may be required for treatment of SMS with INSCOP in space.

Singh, Rajendra P.↗

Probabilistic Assessment of Hypobaric Decompression Sickness Treatment Success

The Hypobaric Decompression Sickness (DCS) Treatment Model links a decrease in computed bubble volume from increased pressure (DeltaP), increased oxygen (O2) partial pressure, and passage of time during treatment to the probability of symptom resolution [P(symptom resolution)]. The decrease in offending volume is realized in 2 stages: a) during compression via Boyle's Law and b) during subsequent dissolution of the gas phase via the O2 window. We established an empirical model for the P(symptom resolution) while accounting for multiple symptoms within subjects. The data consisted of 154 cases of hypobaric DCS symptoms along with ancillary information from tests on 56 men and 18 women. Our best estimated model is P(symptom resolution) = 1 / (1+exp(-(ln(Delta P) - 1.510 + 0.795×AMB - 0.00308×Ts) / 0.478)), where (DeltaP) is pressure difference (psid), AMB = 1 if ambulation took place during part of the altitude exposure, otherwise AMB = 0; and where Ts is the elapsed time in mins from start of the altitude exposure to recognition of a DCS symptom. To apply this model in future scenarios, values of DeltaP as inputs to the model would be calculated from the Tissue Bubble Dynamics Model based on the effective treatment pressure: (DeltaP) = P2 - P1 | = P1×V1/V2 - P1, where V1 is the computed volume of a spherical bubble in a unit volume of tissue at low pressure P1 and V2 is computed volume after a change to a higher pressure P2. If 100% ground level O2 (GLO) was breathed in place of air, then V2 continues to decrease through time at P2 at a faster rate. This calculated value of (DeltaP then represents the effective treatment pressure at any point in time. Simulation of a "pain-only" symptom at 203 min into an ambulatory extravehicular activity (EVA) at 4.3 psia on Mars resulted in a P(symptom resolution) of 0.49 (0.36 to 0.62 95% confidence intervals) on immediate return to 8.2 psia in the Multi-Mission Space Exploration Vehicle. The P(symptom resolution) increased to near certainty (0.99) after 2 hrs of GLO at 8.2 psia or with less certainty on immediate pressurization to 14.7 psia [0.90 (0.83 - 0.95)]. Given the low probability of DCS during EVA and the prompt treatment of a symptom with guidance from the model, it is likely that the symptom and gas phase will resolve with minimum resources and minimal impact on astronaut health, safety, and productivity.

Conkin, Johnny↗

Evaluation of Non-Nuclear Techniques for Well Logging (Final Report)

The focus of this study is the understanding of the technical obstacles that hinder the replacement of and the disadvantages from the loss of extensive interpretation experience based on data accumulated with AmBe. Enhanced acoustic and electromagnetic sensing methods in combination with non-isotope-based well logging techniques have the potential to complement and/or replace existing isotope-based techniques, providing the opportunity to reduce oil industry dependence on isotopic sources such as AmBe.

58 GEOSCIENCES↗

Restoration and Modification of Magnetosome Biosynthesis by Internal Gene Acquisition in a Magnetotactic Bacterium

We report that the Integration of a large-sized DNA fragment into a chromosome is an important strategy for characterization of cellular functions in microorganisms. Magnetotactic bacteria synthesize intracellular organelles comprising membrane-bound single crystalline magnetite, also referred to as magnetosomes. Magnetosomes have gained interest in both scientific and engineering sectors as they can be utilized as a material for biomedical and nanotechnological applications. Although genetic engineering of magnetosome biosynthesis mechanism has been investigated, the current method requires cumbersome gene preparation processes. Here, the chromosomal integration of a plasmid containing ≈27 magnetosome genes (≈26 kbp region) in a non-magnetic mutant of Magnetospirillum magneticum AMB-1 using a broad-host-range plasmid is shown. The genome sequencing of gene-complemented strains reveals the chromosomal integration of the plasmid with magnetosome genes at a specific site, most likely by catalysis of an endogenous transposase. Magnetosome production is successfully enhanced by integrating a variation of magnetosome gene operons in the chromosome. This chromosomal integration mechanism will allow the design of functional magnetosomes de novo and M. magneticum AMB-1 may be used as a chassis for the designed magnetosome production.

59 BASIC BIOLOGICAL SCIENCES↗

Bacteria as Bio-Template for 3D Carbon Nanotube Architectures

It is one of the most important needs to develop renewable, scalable and multifunctional methods for the fabrication of 3D carbon architectures. Even though a lot of methods have been developed to create porous and mechanically stable 3D scaffolds, the fabrication and control over the synthesis of such architectures still remain a challenge. Here, we used Magnetospirillum magneticum (AMB-1) bacteria as a bio-template to fabricate light-weight 3D solid structure of carbon nanotubes (CNTs) with interconnected porosity. The resulting porous scaffold showed good mechanical stability and large surface area because of the excellent pore interconnection and high porosity. Steered molecular dynamics simulations were used to quantify the interactions between nanotubes and AMB-1 via the cell surface protein MSP-1 and flagellin. Furthermore, the 3D CNTs-AMB1 nanocomposite scaffold is further demonstrated as a potential substrate for electrodes in supercapacitor applications.

42 ENGINEERING↗

Introduction, Investigation, and Experimental Validation of a Novel Passive Neutron Spectrometer

Unfolding neutron energy spectra are instrumental for determining personal health effects and calculating dose received. This area of study is heavily researched, and Lawrence Livermore National Laboratory (LLNL) is investigating a passive neutron spectrometer for the purpose of acquiring the information needed to determine personnel dose in the event of a criticality accident. A part of this investigation is presented in this article through the examination of four experimental detector responses (DRs). These four DRs were acquired in the presence of 252 Cf, AmBe, GODIVA, and National Ignition Facility (NIF) neutron sources. An algorithm developed at LLNL was used to unfold the neutron fluence from each of the four DRs, and subsequently, fluence-to-dose conversion factors provided by the American National Standards Institute were used to calculate dose. Additionally, a multistep unfolding process was developed and employed to calculate the effects of both direct (from the source) and indirect (from room return) neutrons. The average error when unfolding the direct DR was less than 8%. The dose from 252 Cf was predicted with only 8% error. The multistep approach allowed for the identification of the low-energy neutrons in the 252 Cf, AmBe, and NIF DRs.

Nuclear Criticality Safety Program (NCSP)↗

Cooling and Timing Tests of the ATLAS Fast TracKer VME Boards

The Fast TracKer (FTK) is an ATLAS trigger upgrade built for full-event, low-latency, high-rate tracking. The FTK core, made of 9U VME boards, performs the most demanding computational task. The associative memory board (AMB) serial link processor and the auxiliary card (AUX), plugged on the front and back sides of the same VME slot, constitute the processing unit (PU), which finds tracks using hits from eight layers of the inner detector. The PU works in pipeline with the second stage board (SSB), which finds 12-layer tracks by adding extra hits to the identified tracks. In the designed configuration, 16 PUs and four SSBs are installed in a VME crate. The high power consumption of the AMB, AUX, and SSB (respectively, of about 250, 70, and 160 W per board) required the development of a custom cooling system. Even though the expected power consumption for each VME crate of the FTK system is high compared with a common VME setup, the 8 FTK core crates will use ≈60 kW, which is just a fraction of the power and the space needed for a CPU farm performing the same task. We report on the integration of 32 PUs and eight SSBs inside the FTK system, on the infrastructures needed to run and cool them, and on the tests performed to verify the system processing rate and the temperature stability at a safe value.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PlanHab * : hypoxia does not worsen the impairment of skeletal muscle oxidative function induced by bed rest alone

Key points Superposition of hypoxia on 21 day bed rest did not worsen the impairment of skeletal muscle oxidative function induced by bed rest alone. A significant impairment of maximal oxidative performance was identified downstream of cardiovascular O 2 delivery, involving both the intramuscular matching between O 2 supply and utilization and mitochondrial respiration. These chronic adaptations appear to be relevant in terms of exposure to spaceflights and reduced gravity habitats (Moon or Mars), as characterized by low gravity and hypoxia, in patients with chronic diseases characterized by hypomobility/immobility and hypoxia, as well as in ageing. Abstract Skeletal muscle oxidative function was evaluated in 11 healthy males (mean ± SD age 27 ± 5 years) prior to (baseline data collection, BDC) and following a 21 day horizontal bed rest (BR), carried out in normoxia ( = 133 mmHg; N‐BR) and hypoxia ( = 90 mmHg; H‐BR). H‐BR was aimed at simulating reduced gravity habitats. The effects of a 21 day hypoxic ambulatory confinement ( = 90 mmHg; H‐AMB) were also assessed. Pulmonary O 2 uptake ( ), vastus lateralis fractional O 2 extraction (changes in deoxygenated haemoglobin + myoglobin concentration, Δ[deoxy(Hb + Mb)]; near‐infrared spectroscopy) and femoral artery blood flow (ultrasound Doppler) were evaluated during incremental one‐leg knee‐extension exercise (reduced constraints to cardiovascular O 2 delivery) carried out to voluntary exhaustion in a normoxic environment. Mitochondrial respiration was evaluated ex vivo by high‐resolution respirometry in permeabilized vastus lateralis fibres. decreased ( P < 0.05) after N‐BR (0.98 ± 0.13 L min −1 ) and H‐BR (0.96 ± 0.17 L min −1 ) vs . BDC (1.05 ± 0.14 L min −1 ). In the presence of a decreased (by ∼6–8%) thigh muscle volume, normalized per unit of muscle mass was not affected by both interventions. Δ[deoxy(Hb + Mb)] peak decreased ( P < 0.05) after N‐BR (65 ± 13% of limb ischaemia) and H‐BR (62 ± 12%) vs . BDC (73 ± 13%). H‐AMB did not alter or Δ[deoxy(Hb + Mb)] peak . An overshoot of Δ[deoxy(Hb + Mb)] was evident during the first minute of unloaded exercise after N‐BR and H‐BR. Arterial blood flow to the lower limb during both unloaded and peak knee extension was not affected by any intervention. Maximal ADP‐stimulated mitochondrial respiration decreased ( P < 0.05) after all interventions vs . control. In 21 day N‐BR, a significant impairment of oxidative metabolism occurred downstream of cardiovascular O 2 delivery, affecting both mitochondrial respiration and presumably the intramuscular matching between O 2 supply and utilization. Superposition of H on BR did not worsen the impairment induced by BR alone.

Salvadego, Desy↗

Summary of Alpha-Neutron Sources in GADRAS

A common source of neutrons for calibration and testing is alpha-neutron material, named for the alpha-neutron nuclear reaction that occurs within. This material contains a long-lived alpha-emitter and a lighter target element. When the alpha particle from the emitter is absorbed by the target, neutrons and gamma rays are released. Gamma Detector Response and Analysis Software (GADRAS) includes built-in alpha-neutron source definitions for AcC, AmB, AmBe, AmF, AmLi, CmC, and PuC. In addition, GADRAS users may create their own alpha-neutron sources by placing valid alpha-emitters and target elements in materials within their one-dimensional models (1DModel). GADRAS has the ability to use pre-built alpha-neutron sources for plotting or as trace-sources in 1D models. In addition, if any material (existing or user-defined) specified in a 1D model contains both an alpha emitter in conjunction with a target nuclide, or there is an interface between such materials, then the appropriate neutron-emission rate from the alpha-neutron reaction will be computed. The gamma-emissions from these sources are also computed, but are limited to a subset of nine target nuclides. If a user has experimental data to contribute to the alpha-neutron gamma emission database, it may be added directly or submitted to the GADRAS developers for inclusion. The gadras.exe.config file will be replaced when GADRAS updates are installed, so sending the information to the GADRAS developers is the preferred method for updating the database. This is also preferable because it enables other users to benefit from your efforts.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detailed Characterization of Nuclear Recoil Pulse Shape Discrimination in the DarkSide-50 Direct Dark Matter Experiment

While evidence of non-baryonic dark matter has been accumulating for decades, its exact nature continues to remain a mystery. Weakly Interacting Massive Particles (WIMPs) are a well motivated candidate which appear in certain extensions of the Standard Model, independently of dark matter theory. If such particles exist, they should occasionally interact with particles of normal matter, producing a signal which may be detected. The DarkSide-50 direct dark matter experiment aims to detect the energy of recoiling argon atoms due to the elastic scattering of postulated WIMPs. In order to make such a discovery, a clear understanding of both the background and signal region is essential. This understanding requires a careful study of the detector's response to radioactive sources, which in turn requires such sources may be safely introduced into or near the detector volume and reliably removed. The CALibration Insertaion System (CALIS) was designed and built for this purpose in a j oint effort between Fermi National Laboratory and the University of Hawaii. This work describes the design and testing of CALIS, its installation and commissioning at the Laboratori Nazionali del Gran Sasso (LNGS) and the multiple calibration campaigns which have successfully employed it. As nuclear recoils produced by WIMPs are indistinguishable from those produced by neutrons, radiogenic neutrons are both the most dangerous class of background and a vital calibration source for the study of the potential WIMP signal. Prior to the calibration of DarkSide-50 with radioactive neutron sources, the acceptance region was determined by the extrapolation of nuclear recoil data from a separate, dedicated experiment, ScENE, which measured the distribution of the pulse shape discrimination parameter, $f_{90}$, for nuclear recoils of known energies. This work demonstrates the validity of the extrapolation of ScENE values to DarkSide-50, by direct comparison of the $f_{90}$ distributio n of nuclear recoils from ScENE and an AmBe calibration sour! ce. The combined acceptance as defined by ScENE and the \textit{in-situ} AmBe calibration were used to establish the best WIMP exclusion limit on an argon target. Unfortunately, radioactive sources used for the calibration of DarkSide-50 are universally accompanied by gamma decays, which obscure the low energy region where most WIMP interactions are expected to occur and seem to make continuing dependence on an external measurement such as ScENE inevitable. However, this work presents a novel method of nuclear recoil calibration employing event selection, unique to the design of DarkSide-50, which produces a nearly pure sample of nuclear recoils. Further, it describes the execution of a neutron calibration campaign, from planning to analysis, which yielded a valuable data set for defining the acceptance region. Together with the event selection techniques, this allows for the definition of the acceptance region independent of ScENE values. Two analytical models of the $f_{90 }$ distribution are described and their results for nuclear recoils are compared. Finally, a detailed study of integrated noise in nuclear and electron recoil

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fluid and electrolyte shifts in women during +Gz acceleration after 15 days' bed rest

Experiments were conducted on twelve women aged 23-34 yr - a bed rest (BR) group of eight subjects and an ambulatory (AMB) group of four subjects - to determine the effect of bed rest on shifts in plasma volume, electrolytes, and erythrocyte volume during +Gz acceleration on a centrifuge. The BR group underwent the +Gz acceleration during a two-week ambulatory control period, after 15 days of a 17-day BR period, and on the third day of ambulatory recovery. The AMB group underwent the same experimental procedures, but continued their normal daily routine during the BR period without additional prescribed physical exercise. Major conclusions are that (1) the higher the mean control tolerance, the greater the tolerance decline after BR; (2) relative confinement and reduced activity contribute as much to reduction in tolerance as does the horizontal body position during BR; (3) BR deconditioning has no effect on the erythrocyte volume during +3.0 Gz; and (4) about one-half the loss in tolerance after BR can be attributed to plasma volume and electrolyte shifts.

Greenleaf, J. E.↗

Detailed Performance Calculations: Portland State Group, Appendix F

For the Portland State University FAGE instrument, laser induced OH is calculated from (OH) laser = Cl(03)amb(H2O)amb. The dominant noise sources are the photon-counting fluctuations associated with the OH signal and the fluorescence background as well as concentration fluctuations in OH and in the species causing the background. Baric filtering and temporal filtering suppress the background by factors of 10 each.

Source record↗

Two-phase flows and heat transfer within systems with ambient pressure above the thermodynamic critical pressure

In systems where the design inlet and outlet pressures P sub amb are maintained above the thermodynamic critical pressure P sub c, it is often assumed that heat and mass transfer are governed by single-phase relations and that two-phase flows cannot occur. This simple rule of thumb is adequate in many low-power designs but is inadequate for high-performance turbomachines, boilers, and other systems where two-phase regions can exist even though P sub amb P sub c. Heat and mass transfer and rotordynamic-fluid-mechanic restoring forces depend on momentum differences, and those for a two-phase zone can differ significantly from those for a single-phase zone. By using a laminar, variable-property bearing code and a rotating boiler code, pressure and temperature surfaces were determined that illustrate nesting of a two-phase region within a supercritical pressure region. The method of corresponding states is applied to bearings with reasonable rapport.

Hendricks, R. C.↗