Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ambient Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Investigation of turbulent diffusion in the extreme lower atmosphere

Turbulent diffusion in the extreme lower layer of the atmosphere (up to 5 m) has been investigated. Turbulent flow was simulated under dry, stable and calm conditions by means of a 3.04 m diameter fan installed at a field site situated on flat grassland. The ambient wind was continuously monitored by means of a cup anemometer placed outside the wake, and the temperature distribution was measured by four thermometers placed on an 18 m tower, also outside the wake. Balloons and red smoke were used to visualize the wake flow and investigate the predominant sizes of turbulent eddies and their streamwise behavior. The mean and turbulent velocities along the turbulence line were measured using an array of hot-wire anomometers. Results provide substantial verification of a recently proposed model (Koper and Sadeh, 1975; Koper et al., 1978) relating the Lagrangian to the Eulerian turbulent velocity autocorrelation. In this model the Lagrangian autocorrelation is given by a domain integral over a set of ordinary Eulerian autocorrelations acquired simultaneously at all points within the flow field in question, which is viewed as a turbulence 'box'.

Koper, C. A., Jr.↗

Integrated-Optic Oxygen Sensors

Compact optical oxygen sensors with self-calibration capabilities are undergoing development. A sensor of this type features a single-chip, integrated-optic design implemented by photolithographic fabrication of optical waveguides in a photosensitive porous glass. The porosity serves as both a matrix for retention of an oxygen-sensitive fluorescent indicator chemical and a medium for diffusion of oxygen to the chemical from the ambient air to be monitored. Each sensor includes at least one such waveguide exposed to the atmosphere and at least one covered with metal for isolation from the atmosphere. The covered one serves as a reference channel. In operation, the concentration of oxygen is deduced from the intensity and lifetime of the fluorescence in the exposed channel, with the help of calibration data acquired via the reference channel. Because the sensory chemical is placed directly in and throughout the cross section of the light path, approximately 99 percent of the light in the waveguide is available for interaction with the chemical, in contradistinction to only about 1 percent of the light in an optical sensor that utilizes evanescentwave coupling. Hence, a sensor of this type is significantly more sensitive.

Mendoza, Edgar A.↗

Long term monitoring of methane in the atmosphere by multiplex gas chromatography

Methane is of interest in the study of the Earth's atmosphere because of its implication in the future global warming of the surface. This warming is produced by the absorption of infrared energy by trace gases. It has been estimated that in the next 40 to 50 years, methane could contribute 20 to 25 pct. as much atmospheric warming as that expected from carbon dioxide increases. Studies to examine sources, sinks, and cycles of methane will require analytical methods capable of continuous unattended measurement with temporal resolution of an hour or less for weeks at a time. Gas chromatography (GC) is one of the most practical methods available to conduct the analysis of air, but limitations in this technique still exist which can be alleviated with multiplex GC (MGC). MGC is a technique where many samples are pseudo-randomly introduced to the chromatograph without regard to the length of time required for an analysis. The resulting data must then be reduced using computational methods such as cross correlation. In the technique reported, a tube packed with silver oxide was used at the inlet of the GC column to create concentration pulses of methane in a sample stream of air. By using only one carrier, i.e., ambient air, an effective and accurate method to monitor the variations in concentration of methane in the atmosphere over long periods of time was developed. Methane in ambient air was monitored for an eight day period and an interesting temporal variability was found. This work has shown the utility of a relatively simple MGC for the analysis of a real environmental sample.

Valentin, Jose R.↗

Recommendations for Using Noise Monitors to Estimate Noise Exposure During X-59 Community Tests

A low fidelity simulation approach is used to explore how to place and use noise monitors during X-59 QueSST community tests, where people’s annoyance to the noise produced by the X-59 aircraft will be gathered. Several recommendations are provided including: 1) the desired number of sparsely spaced noise monitor sites within the survey area, 2) whether to group and average measurements across multiple noise monitors located at a site, 3) what spacing should be used if grouped noise monitors are used, 4) an approach to mitigate ambient noise contamination at the measurement sites, 5) a method to combine empirical and predicted dose estimates to provide a single dose estimate for respondents, and 6) assessing how changes in turbulence intensity and array configuration affect dose uncertainty. To make these recommendations, the error that is expected when fitting contrived, smoothly varying sonic boom “reference exposure surfaces” is studied when a spatially sparse and scattered set of samples is used as responses for the fit. The reference exposure surfaces mimic the sonic boom exposure at ground level that might be expected in the X-59 survey area in the absence of atmospheric turbulence, ambient noise, and other localized effects. The spatial extent of these surfaces varies and is representative of the different survey area sizes that might be expected during future X-59 community overflight tests. These contrived reference surfaces are sampled, and those reference samples are then perturbed to mimic atmospheric turbulence, ambient noise and other localized effects that might affect noise monitor measurements within overflown communities. Two different surface fitting methods are investigated when fitting these perturbed samples to approximate the reference surface. The first method uses interpolation between the perturbed data at the scattered sites to compute the fit. The second method fits a polynomial surface model to the perturbed data using ordinary least squares regression analysis. For both fitting methods, the root mean square fit error is computed from the pointwise difference between the fit surface and the reference surface as the count and configuration of the sites is varied while also averaging the error across many different realizations of both the smooth variation of the reference exposure surface and the random, localized perturbations at the sample sites. Different site configurations are compared using this error statistic to make the recommendations noted above. Additionally, the two fitting approaches (interpolation vs linear regression) are compared based on the fit error observed in these simulations. These analyses, comparisons, and recommendations should inform future decisions on the noise monitor placement and the methods used to analyze the noise monitor data that is collected during X-59 community overflights.

sonic boom↗

A Network of Field-Calibrated Low-Cost Sensor Measurements of PM2.5 in Lomé, Togo, Over One to Two Years

Air pollution is a leading cause of global premature mortality and is especially prevalent in many low- and middle-income countries (LMICs). In sub-Saharan Africa, preliminary monitoring networks, satellite retrievals of air-quality-relevant species, and air quality models show ambient fine particulate matter (PM 2.5 ) concentrations that far exceed the World Health Organization guidelines, yet many areas remain largely unmonitored and understudied. Deploying a network of five low-cost PurpleAir PM 2.5 monitors over 2 years (2019–2021), we present the first multiyear ambient air pollution monitoring data results from Lomé, Togo, a major West African coastal city with a population of about 1.4 million people. The full-study time period network-wide mean measured daily PM 2.5 concentration is 23.5 μ g m –3 m –3 . The strong regional influence of the dry and dusty Harmattan wind increases the local average PM 2.5 concentration by up to 58% during December through February, but the diurnal and weekly trends in PM 2.5 are largely controlled by local influences. At all sites, more than 87% of measured days exceeded the new WHO Daily PM 2.5 guidelines; these first measurements highlight the need for air quality improvement in a rapidly growing urban metropolis.

air pollution↗

Design considerations in the creation and maintenance of electrostatic cleanliness for solar electrically propelled spacecraft

Charge build-up on spacecraft surfaces and resulting zones of electrostatic contamination have been examined for electrically active and electrically passive spacecraft with both conducting and dielectric surface materials, illuminated and nonilluminated surface conditions, and for both inclusion and neglect of free charge effects from photocurrents and ambient space plasma particles. Techniques for measurement and reduction of electrostatic contamination zone extent have been developed for spacecraft with charge release capability. Indicated limitations for contamination cleanup are about 1 volt potential variation from spacecraft to ambient plasma. Bandwidths of electrostatic monitoring and clamping devices extend to several hundred kilohertz for both DC and 'broadband' AC electrostatic cleanliness.

Sellen, J. M., Jr.↗

Detection of biogenic CO production above vascular cell cultures using a near-room-temperature QC-DFB laser

We report the first application of pulsed, near-room-temperature quantum cascade laser technology to the continuous detection of biogenic CO production rates above viable cultures of vascular smooth muscle cells. A computer-controlled sequence of measurements over a 9-h period was obtained, resulting in a minimum detectable CO production of 20 ppb in a 1-m optical path above a standard cell-culture flask. Data-processing procedures for real-time monitoring of both biogenic and ambient atmospheric CO concentrations are described.

NASA Discipline Life Sciences Technologies↗

Evaluation of a hydrogen chloride detector for environmental monitoring

The paper describes a hydrogen chloride detector designed to monitor concentrations of hydrogen chloride gas in the ambient environment. The detector was developed for NASA for use in launch vehicle effluent monitoring. The detector operates on chemiluminescence principles with a lower detection limit of less than 5 x 10 to the -3rd ppm (by volume). The hydrogen chloride in the air sample reacts with a bromide-bromate coating in the inlet tube of the instrument producing bromine. Bromine is then quantitated by chemiluminescent oxidation of luminol. The visible light generated in the chemiluminescent reaction is proportional to the hydrogen chloride concentration of the sampled airstream. The detector is most suited to laboratory or field studies where hydrogen chloride is the dominant pollutant, as compared to the interfering species. Interferences include strong acids, acid-forming gases, and halogen gases. Of the interferences investigated the most serious in these groups are hydrochloric and sulfuric acid, sulfur dioxide, and chlorine, respectively. The detector has been in use since 1974 and has been found to be highly portable, rugged, and stable under extreme environmental conditions.

Gregory, G. L.↗

Development and Performance of a Filter Radiometer Monitor System for Integrating Sphere Sources

The NASA Goddard Space Flight Center (GSFC) Radiometric Calibration Laboratory (RCL) maintains several large integrating sphere sources covering the visible to the shortwave infrared wavelength range. Two critical, functional requirements of an integrating sphere source are short and long-term operational stability and repeatability. Monitoring the source is essential in determining the origin of systemic errors, thus increasing confidence in source performance and quantifying repeatability. If monitor data falls outside the established parameters, this could be an indication that the source requires maintenance or re-calibration against the National Institute of Science and Technology (NIST) irradiance standard. The GSFC RCL has developed a Filter Radiometer Monitoring System (FRMS) to continuously monitor the performance of its integrating sphere calibration sources in the 400 to 2400nm region. Sphere output change mechanisms include lamp aging, coating (e.g. BaSO4) deterioration, and ambient water vapor level. The Filter Radiometer Monitor System (FRMS) wavelength bands are selected to quantify changes caused by these mechanisms. The FRMS design and operation are presented, as well as data from monitoring four of the RCL s integrating sphere sources.

Ding, Leibo↗

Methods and Piezoelectric Imbedded Sensors for Damage Detection in Composite Plates Under Ambient and Cryogenic Conditions

New methods for structural health monitoring are being assessed, especially in high-performance, extreme environment, safety-critical applications. One such application is for composite cryogenic fuel tanks. The work presented here attempts to characterize and investigate the feasibility of using imbedded piezoelectric sensors to detect cracks and delaminations under cryogenic and ambient conditions. A variety of damage detection methods and different Sensors are employed in the different composite plate samples to aid in determining an optimal algorithm, sensor placement strategy, and type of imbedded sensor to use. Variations of frequency, impedance measurements, and pulse echoing techniques of the sensors are employed and compared. Statistical and analytic techniques are then used to determine which method is most desirable for a specific type of damage. These results are furthermore compared with previous work using externally mounted sensors. Results and optimized methods from this work can then be incorporated into a larger composite structure to validate and assess its structural health. This could prove to be important in the development and qualification of any 2" generation reusable launch vehicle using composites as a structural element.

Engberg, Robert↗

ANITA Air Monitoring on the International Space Station: Results Compared to Other Measurements

ANITA (Analysing Interferometer for Ambient Air) is a flight experiment precursor for a permanent continuous air quality monitoring system on the ISS (International Space Station). For the safety of the crew, ANITA can detect and quantify quasi-online and simultaneously 33 gas compounds in the air with ppm or sub-ppm detection limits. The autonomous measurement system is based on FTIR (Fourier Transform Infra-Red spectroscopy). The system represents a versatile air quality monitor, allowing for the first time the detection and monitoring of trace gas dynamics in a spacecraft atmosphere. ANITA operated on the ISS from September 2007 to August 2008. This paper summarizes the results of ANITA s air analyses with emphasis on comparisons to other measurements. The main basis of comparison is NASA s set of grab samples taken onboard the ISS and analysed on ground applying various GC-based (Gas Chromatography) systems.

Honne, A.↗

Definition of air quality measurements for monitoring space shuttle launches

A description of a recommended air quality monitoring network to characterize the impact on ambient air quality in the Kennedy Space Center (KSC) (area) of space shuttle launch operations is given. Analysis of ground cloud processes and prevalent meteorological conditions indicates that transient HCl depositions can be a cause for concern. The system designed to monitor HCl employs an extensive network of inexpensive detectors combined with a central analysis device. An acid rain network is also recommended. A quantitative measure of projected minimal long-term impact involves the limited monitoring of NOx and particulates. All recommended monitoring is confined ti KSC property.

Thorpe, R. D.↗

Preliminary analysis of an extensive one year survey of trace elements and compounds in the suspended particulate matter in Cleveland, Ohio

Beginning in 1971 a cooperative program has been carried on by the City of Cleveland Division of Air Pollution Control and NASA Lewis Research Center to study the trace element and compound concentrations in the ambient suspended particulate matter in Cleveland Ohio as a function of source, monitoring location and meteorological conditions. The major objectives were to determine the ambient concentration levels at representative urban sites and to develop a technique using trace element and compound data in conjunction with meteorological conditions to identify specific pollution sources which could be developed into a practical system that could be readily utilized by an enforcement agency.

King, R. B.↗

NASA Tech Briefs, July 2011

Topics covered include: 1) Collaborative Clustering for Sensor Networks; 2) Teleoperated Marsupial Mobile Sensor Platform Pair for Telepresence Insertion Into Challenging Structures; 3) Automated Verification of Spatial Resolution in Remotely Sensed Imagery; 4) Electrical Connector Mechanical Seating Sensor; 5) In Situ Aerosol Detector; 6) Multi-Parameter Aerosol Scattering Sensor; 7) MOSFET Switching Circuit Protects Shape Memory Alloy Actuators; 8) Optimized FPGA Implementation of Multi-Rate FIR Filters Through Thread Decomposition; 9) Circuit for Communication Over Power Lines; 10) High-Efficiency Ka-Band Waveguide Two-Way Asymmetric Power Combiner; 11) 10-100 Gbps Offload NIC for WAN, NLR, and Grid Computing; 12) Pulsed Laser System to Simulate Effects of Cosmic Rays in Semiconductor Devices; 13) Flight Planning in the Cloud; 14) MPS Editor; 15) Object-Oriented Multi Disciplinary Design, Analysis, and Optimization Tool; 16) Cryogenic-Compatible Winchester Connector Mount and Retaining System for Composite Tubes; 17) Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy; 18) Planar Rotary Piezoelectric Motor Using Ultrasonic Horns; 19) Self-Rupturing Hermetic Valve; 20) Explosive Bolt Dual-Initiated from One Side; 21) Dampers for Stationary Labyrinth Seals; 22) Two-Arm Flexible Thermal Strap; 23) Carbon Dioxide Removal via Passive Thermal Approaches; 24) Polymer Electrolyte-Based Ambient Temperature Oxygen Microsensors for Environmental Monitoring; 25) Pressure Shell Approach to Integrated Environmental Protection; 26) Image Quality Indicator for Infrared Inspections; 27) Micro-Slit Collimators for X-Ray/Gamma-Ray Imaging; 28) Scatterometer-Calibrated Stability Verification Method; 29) Test Port for Fiber-Optic-Coupled Laser Altimeter; 30) Phase Retrieval System for Assessing Diamond Turning and Optical Surface Defects; 31) Laser Oscillator Incorporating a Wedged Polarization Rotator and a Porro Prism as Cavity Mirror; 32) Generic, Extensible, Configurable Push-Pull Framework for Large-Scale Science Missions; 33) Dynamic Loads Generation for Multi-Point Vibration Excitation Problems; 34) Optimal Control via Self-Generated Stochasticity; 35) Space-Time Localization of Plasma Turbulence Using Multiple Spacecraft Radio Links; 36) Surface Contact Model for Comets and Asteroids; 37) Dust Mitigation Vehicle; 38) Optical Coating Performance for Heat Reflectors of the JWST-ISIM Electronic Component; 39) SpaceCube Demonstration Platform; 40) Aperture Mask for Unambiguous Parity Determination in Long Wavelength Imagers; 41) Spaceflight Ka-Band High-Rate Radiation-Hard Modulator; 42) Enabling Disabled Persons to Gain Access to Digital Media; 43) Cytometer on a Chip; 44) Principles, Techniques, and Applications of Tissue Microfluidics; and 45) Two-Stage Winch for Kites and Tethered Balloons or Blimps.

Source record↗

Environmental stability of intercalated graphite fibers

Graphite fibers intercalated with bromine, iodine monochloride, ferric chloride, and cupric chloride were subjected to stability tests under four environments which are encountered by engineering materials in the aerospace industry: ambient laboratory conditions, as would be experienced during handling operations and terrestrial applications; high vacuum, as would be experienced in space applications; high humidity, as would be experienced in marine applications; and high temperature, as would be experienced in some processing steps and applications. Monitoring the resistance of the fibers at ambient laboratory conditions revealed that only the ferric chloride intercalated fibers were unstable, due to absorption of water from the air. All four types of intercalated fibers were unstable, due to absorption of water from the air. All four types of intercalated fibers were stable for long periods under high vacuum. Ferric chloride, cupric chloride, and iodine monochloride intercalated fibers were sensitive to high humidity conditions. All intercalated fibers began to degrade above 250 C. The order of their thermal stability, from lowest to highest, was cupric chloride, iodine monochloride, bromine, and ferric chloride. Of the four types of intercalated fibers tested, the bromine intercalated fibers appear to have the most potential for application, based on environmental stability.

Gaier, J. R.↗

Environmental stability of intercalated graphite fibers

Graphite fibers intercalated with bromine, iodine monochloride, ferric chloride, and cupric chloride were subjected to stability tests under four environments which are encountered by engineering materials in the aerospace industry: ambient laboratory conditions, as would be experienced during handling operations and terrestrial applications; high vacuum, as would be experienced in space applications; high humidity, as would be experienced in marine applications; and high temperature, as would be experienced in some processing steps and applications. Monitoring the resistance of the fibers at ambient laboratory conditions revealed that only the ferric chloride intercalated fibers were unstable, due to absorption of water from the air. All four types of intercalated fibers were unstable, due to absorption of water from the air. All four types of intercalated fibers were stable for long periods under high vacuum. Ferric chloride, cupric chloride, and iodine monochloride intercalated fibers were sensitive to high humidity conditions. All intercalated fibers began to degrade above 250 C. The order of their thermal stability, from lowest to highest, was cupric chloride, iodine monochloride, bromine, and ferric chloride. Of the four types of intercalated fibers tested, the bromine intercalated fibers appear to have the most potential for application, based on environmental stability.

Gaier, J. R.↗

Evaluation of HAN-TEAN Stabilizers using Microcalorimetry

HAN-TEAN (hydroxylammonium nitrate - triethanolammonium nitrate - in water) is being considered for various propellant applications. This propellant has advantages in terms of insensitivity to impact and fire, low vapor pressure and environmentally benign reaction products. One office concerns with HAN-TEAN is its stability and shelf-life, especially when contaminated with trace metals. Stabilizer systems, consisting of anti-oxidants and/or chealating agents were investigated for their ability to control the decomposition of HAN-TEAN. Isothermal microcalorimetry, an ultrasensitive heat measurement technique, was used to monitor the decomposition of HANTEAN at near ambient temperatures. Isothermal microcalorimetry measures the heat flow from a reaction vessel into a surrounding heat sink. Microcalorimetry is approximately 1,000 times more sensitive than accelerating rate calorimetry (ARC) or differential scanning calorimetry (DSC) for measuring heat flow. Samples of HAN-TEAN containing the stabilizers were spiked with 50 ppm iron and the heat evolution monitored for a period of at least 30 days. Ten stabilizer combinations were tested and the rates of HAN-TEAN decomposition were lowered by 74 to 95 percent in the presence of iron.

Hornung, Steven D.↗