A new approach to micro-arcsecond astrometry with SIM allowing early mission narrow angle measurements of compelling astronomical targets
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The attitude of a spacecraft is determined by specifying independent parameters which relate the spacecraft axes to an inertial coordinate system. Sensors which measure angles between spin axis and other vectors directed to objects or fields external to the spacecraft are discussed. For the spin-stabilized spacecraft considered, the spin axis is constant over at least an orbit, but separate solutions based on sensor angle measurements are different due to propagation of errors. Sensor-angle solution methods are described which minimize the propagated errors by making use of least squares techniques over many sensor angle measurements and by solving explicitly (in closed form) for the spin axis coordinates. These methods are compared with star observation solutions to determine if satisfactory accuracy is obtained by each method.
The measurement of local flow angle is critical in many fluid-dynamic applications, including the aerodynamic flight testing of new aircraft and flight systems. Flight researchers at NASA Dryden Flight Research Center have recently developed, flight-tested, and patented the force-based flow-angle probe (FLAP), a novel, force-based instrument for the measurement of local flow direction. Containing no moving parts, the FLAP may provide greater simplicity, improved accuracy, and increased measurement access, relative to conventional moving vane-type flow-angle probes. Forces in the FLAP can be measured by various techniques, including those that involve conventional strain gauges (based on electrical resistance) and those that involve more advanced strain gauges (based on optical fibers). A correlation is used to convert force-measurement data to the local flow angle. The use of fiber optics will enable the construction of a miniature FLAP, leading to the possibility of flow measurement in very small or confined regions. This may also enable the tufting of a surface with miniature FLAPs, capable of quantitative flow-angle measurements, similar to attaching yarn tufts for qualitative measurements. The prototype FLAP was a small, aerodynamically shaped, low-aspect-ratio fin about 2 in. (approximately equal to 5 cm) long, 1 in. (approximately equal to 2.5 cm) wide, and 0.125 in. (approximately equal to 0.3 cm) thick (see Figure 1). The prototype FLAP included simple electrical-resistance strain gauges for measuring forces. Four strain gauges were mounted on the FLAP; two on the upper surface and two on the lower surface. The gauges were connected to form a full Wheatstone bridge, configured as a bending bridge. In preparation for a flight test, the prototype FLAP was mounted on the airdata boom of a flight-test fixture (FTF) on the NASA Dryden F-15B flight research airplane.
The extension of Hoover's (1971) technique to the case of dihedral-angle measurement is described. Dihedral angles are often determined by interferometry on thermally grooved grain boundaries to obtain information on relative interfacial energies. In the technique considered the measured angles approach the true angles as the tilt angle approaches 90 deg. It is pointed out that the scanning electron microscopy method provides a means of seeing the real root of a groove at a lateral magnification which is higher than that obtainable with interferometry.
This paper describes the development of a two-camera, video imaging system for the determination of three-dimensional spatial coordinates from stereo images. This system successfully measured angle of attack at several span-wise locations for large-scale parafoils tested in the NASA Ames 80- by 120-Foot Wind Tunnel. Measurement uncertainty for angle of attack was less than 0.6 deg. The stereo ranging system was the primary source for angle of attack measurements since inclinometers sewn into the fabric ribs of the parafoils had unknown angle offsets acquired during installation. This paper includes discussions of the basic theory and operation of the stereo ranging system, system measurement uncertainty, experimental set-up, calibration results, and test results. Planned improvements and enhancements to the system are also discussed.
Two instrumentation systems are used to measure scatter angle: intensity scatterometer makes small angle measurements on order of 10 arc-minutes; amplitude scatterometer, which uses interferometric principle, measures smaller angles on order of 10 arc-seconds. Both scatterometers use laser sources and can measure into ultraviolet (0.325 micron) wavelengths.
Weld angle is measured to the nearest arc minute and offset to one thousandth of an inch by an instrument designed to use a reference plane at two locations on a test coupon. A special table for computation has been prepared for use with the instrument.
Vacuum optical bench and precision measurement of angles
Sextant sighting performance in measuring angle between stationary simulated star and stationary blinking light
Navigator performance using hand held sextant to measure angle between moving flashing light and simulated star - space navigation
Modified sine bar device measures small angles with enough accuracy to calibrate precision optical autocollimators. The sine bar is a massive bar of steel supported by two cylindrical rods at one end and one at the other.
Optoelectronic shaft-angle encoder measures angle of rotation of shaft with high precision while minimizing effects of eccentricity and other misalignments. Grooves on disk serve as reference marks to locate reading heads and measure increments of rotation of disk. Shaft-angle encoder, resembling optical compact-disk drive, includes two tracking heads illuminating grooves on disk and measures reflections from them.
Various research activities are reported in the following areas: (1) improving and testing probes; (2) theoretical studies of probe motion; and (3) improving research facilities. It is concluded that a satisfactory solution to the problem of measuring angle of attack of helicopter blades may be found in the near future.
A digital pitch and roll monitor was developed that will provide an easy measurement of angle in two axes simultaneously to an accuracy of approximately 0.005 degree. This system provides advantages over any other commercially available angle-measuring device in that an inexperienced operator can obtain quick reliable measurements. The system utilizes three mutually perpendicular accelerometers, mounted on an inclinometer base, and the intelligent signal conditioning equipment needed to convert the output of these sensors to pitch and roll. The two-axis inclinometer consists of three mutually perpendicular accelerometers mounted on an inclinometer base, three digital multimeters to provide power to the accelerometers and digitize their output, a computer to calculate the angles, and a printer to provide hardcopy output.
The results of a laboratory evaluation of electrolytic tilt sensors as potential candidates for measuring model attitude or angle of attack in wind tunnel tests are presented. The performance of eight electrolytic tilt sensors was compared with that of typical servo accelerometers used for angle-of-attack measurements. The areas evaluated included linearity, hysteresis, repeatability, temperature characteristics, roll-on-pitch interaction, sensitivity to lead-wire resistance, step response time, and rectification. Among the sensors being evaluated, the Spectron model RG-37 electrolytic tilt sensors have the highest overall accuracy in terms of linearity, hysteresis, repeatability, temperature sensitivity, and roll sensitivity. A comparison of the sensors with the servo accelerometers revealed that the accuracy of the RG-37 sensors was on the average about one order of magnitude worse. Even though a comparison indicates that the cost of each tilt sensor is about one-third the cost of each servo accelerometer, the sensors are considered unsuitable for angle-of-attack measurements. However, the potential exists for other applications such as wind tunnel wall-attitude measurements where the errors resulting from roll interaction, vibration, and response time are less and sensor temperature can be controlled.