Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ankle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Dynamic analysis of astronaut motions in microgravity: Applications for Extravehicular Activity (EVA)

Simulations of astronaut motions during extravehicular activity (EVA) tasks were performed using computational multibody dynamics methods. The application of computational dynamic simulation to EVA was prompted by the realization that physical microgravity simulators have inherent limitations: viscosity in neutral buoyancy tanks; friction in air bearing floors; short duration for parabolic aircraft; and inertia and friction in suspension mechanisms. These limitations can mask critical dynamic effects that later cause problems during actual EVA's performed in space. Methods of formulating dynamic equations of motion for multibody systems are discussed with emphasis on Kane's method, which forms the basis of the simulations presented herein. Formulation of the equations of motion for a two degree of freedom arm is presented as an explicit example. The four basic steps in creating the computational simulations were: system description, in which the geometry, mass properties, and interconnection of system bodies are input to the computer; equation formulation based on the system description; inverse kinematics, in which the angles, velocities, and accelerations of joints are calculated for prescribed motion of the endpoint (hand) of the arm; and inverse dynamics, in which joint torques are calculated for a prescribed motion. A graphical animation and data plotting program, EVADS (EVA Dynamics Simulation), was developed and used to analyze the results of the simulations that were performed on a Silicon Graphics Indigo2 computer. EVA tasks involving manipulation of the Spartan 204 free flying astronomy payload, as performed during Space Shuttle mission STS-63 (February 1995), served as the subject for two dynamic simulations. An EVA crewmember was modeled as a seven segment system with an eighth segment representing the massive payload attached to the hand. For both simulations, the initial configuration of the lower body (trunk, upper leg, and lower leg) was a neutral microgravity posture. In the first simulation, the payload was manipulated around a circular trajectory of 0.15 m radius in 10 seconds. It was found that the wrist joint theoretically exceeded its ulnal deviation limit by as much as 49. 8 deg and was required to exert torques as high as 26 N-m to accomplish the task, well in excess of the wrist physiological limit of 12 N-m. The largest torque in the first simulation, 52 N-m, occurred in the ankle joint. To avoid these problems, the second simulation placed the arm in a more comfortable initial position and the radius and speed of the circular trajectory were reduced by half. As a result, the joint angles and torques were reduced to values well within their physiological limits. In particular, the maximum wrist torque for the second simulation was only 3 N-m and the maximum ankle torque was only 6 N-m.

Newman, Dava J.↗

Adaptive response of slow and fast skeletal muscle in the monkey to spaceflight

Experiments were designed to determine the effects of the absence of weight support on hindlimb muscles of the monkey: an ankle flexor (tibialis anterior, TA), two ankle extensors (medical gastrocnemius, MG and soleus, SOL), and a knee extensor (vastus lateralis, VL). These experiments will be performed as part of the BION mission. The original project proposed to assess the effects of weightlessness in adult Rhesus monkeys which were to be flown on the Space Shuttle as part of SLS-3. Feasibility studies were carried out and a series of experiments were performed at NASA/Ames Research Center to assess the effects of a 21-day restraint period in the ESOP on muscle properties. The results of these studies are summarized.

Bodine-Fowler, Sue↗

Characteristics and Preliminary Observations of the Influence of Electromyostimulation on the Size and Function of Human Skeletal Muscle During 30 Days of Simulated Microgravity

During 30 days (d) of bedrest, the practicality of using Elec- troMyoStimulation (EMS) as a deterrent to atrophy and strength loss of lower limb musculature was examined. An EMS system was developed that provided variable but quantifiable levels of EMS, and measured torque. The dominant log of three male subjects was stimulated twice daily in a 3-d on/1-d off cycle during bedrest. The non-dominant leg of each subject acted as a control. A stimulator, using a 0.3 ms monophasic 60 Hz pulse waveform, activated muscle tissue for 4 s. The output waveform from the stimulator was sequenced to the Knee Extensors (KE), Knee Flex- ors (KF), Ankle Extensors (AE), and Ankle Flexors (AF), and caused three isometric contractions of each muscle group per minute. Subject tolerance determined EMS Intensity. Each muscle group received four 5-min bouts of EMS each session with a 10 -min rest between bouts. EMS and torque levels for each muscle action were recorded directly an a computer. Overall average EMS Intensity was 197, 197, 195, and 188 mA for the KE, KF, AF, and AE, respectively. Overall average torque development for these muscle groups was 70, 16, 12, and 27 Nm, respectively. EMS intensity doubled during the study, and average torque increased 2.5 times. Average maximum torque throughout a session reached 54% of maximal voluntary for the KE and 29% for the KF. Reductions in leg volume, muscle compartment size, cross-sectional area of slow and fast-twitch fibers, strength, and aerobic enzyme activities, and increased log compliance were attenuated in the legs which received EMS during bedrest. These results indicate that similar EMS levels induce different torques among different muscle groups and that repeated exposure to EMS increases tolerance and torque development. Longer orien- tation periods, therefore, may enhance its effectiveness. Our preliminary data suggest that the efficacy of EMS as an effective countermeasure for muscle atrophy and strength loss during long duration space travel warrants further investigation.

Duvoisin, Marc R.↗

Head-Down Tilt with Balanced Traction as a Model for Simulating Spinal Acclimation to Microgravity

Astronauts experience total body height increases of 4 to 7 cm in microgravity. Thus, stretching of the spinal cord, nerve roots, and muscular and ligamentous tissues may be responsible for the hyperreflexia, back pain, and muscular atrophy associated with exposure to microgravity. Axial compression of the spine makes 6 deg. head-down tilt (HDT) an unsuitable model for spinal acclimation to microgravity. However, this axial compression may be counteracted by balanced traction consisting of 10% body weight (sin 6 deg. = 0.1) applied to the legs. Six healthy male subjects underwent 3 days each of 60 HDT with balanced traction and horizontal bed rest (HBR), with a 2 week recovery period between treatments. Total body and spine length, lumbar disc height, back pain, erector spinae intramuscular pressure, and ankle joint torque were measured before, during and after each treatment. Total body and spine (processes of L5 - C7) lengths increased significantly more during HDT with balanced traction (22 +/- 8 mm and 25 +/- 8 mm, respectively) than during HBR (16 +/- 4 mm and 14 +/- 9 mm, respectively). Back and leg pain were significantly greater during HDT with balanced traction than during HBR. The distance between the lower end plate of L4 and the upper endplate of S1, as measured by sonography, increased significantly in both treatments to the same degree (2.9 +/- 1.9 mm, HDT with balanced traction; 3.3 +/- 1.5 mm, HBR). Intramuscular pressure of the erector spinae muscles and maximal ankle joint torque were unaltered with both models. While neither model increased height to the magnitude observed in microgravity, HDT with balanced traction may be a better model for simulating the body lengthening and back pain experienced in microgravity.

Ballard, R. E.↗

Sensorimotor adaptations to microgravity in humans

Motor function is altered by microgravity, but little detail is available as to what these changes are and how changes in the individual components of the sensorimotor system affect the control of movement. Further, there is little information on whether the changes in motor performance reflect immediate or chronic adaptations to changing gravitational environments. To determine the effects of microgravity on the neural control properties of selected motor pools, four male astronauts from the NASA STS-78 mission performed motor tasks requiring the maintenance of either ankle dorsiflexor or plantarflexor torque. Torques of 10 or 50% of a maximal voluntary contraction (MVC) were requested of the subjects during 10 degrees peak-to-peak sinusoidal movements at 0.5 Hz. When 10% MVC of the plantarflexors was requested, the actual torques generated in-flight were similar to pre-flight values. Post-flight torques were higher than pre- and in-flight torques. The actual torques when 50% MVC was requested were higher in- and post-flight than pre-flight. Soleus (Sol) electromyographic (EMG) amplitudes during plantarflexion were higher in-flight than pre- or post-flight for both the 10 and 50% MVC tasks. No differences in medial gastrocnemius (MG) EMG amplitudes were observed for either the 10 or 50% MVC tasks. The EMG amplitudes of the tibialis anterior (TA), an antagonist to plantarflexion, were higher in- and post-flight than pre-flight for the 50% MVC task. During the dorsiflexion tasks, the torques generated in both the 10 and 50% MVC tasks did not differ pre-, in- and post-flight. TA EMG amplitudes were significantly higher in- than pre-flight for both the 10 or 50% MVC tasks, and remained elevated post-flight for the 50% MVC test. Both the Sol and MG EMG amplitudes were significantly higher in-flight than either pre- or post-flight for both the 10 and 50% MVC tests. These data suggest that the most consistent response to space flight was an elevation in the level of contractions of agonists and antagonists when attempting to maintain constant torques at a given level of MVC. Also, the chronic levels of EMG activity in selected ankle flexor and extensor muscles during space flight and during routine activities on Earth were recorded. Compared with pre- and post-flight values, there was a marked increase in the total EMG activity of the TA and the Sol and no change in the MG EMG activity in-flight. These data indicate that space flight, as occurs on shuttle missions, is a model of elevated activation of both flexor and extensor muscles, probably reflecting the effects of programmed work schedules in flight rather than a direct effect of microgravity.

NASA Experiment Number 284036↗

Emergence of postural patterns as a function of vision and translation frequency

Emergence of postural patterns as a function of vision and translation frequency. We examined the frequency characteristics of human postural coordination and the role of visual information in this coordination. Eight healthy adults maintained balance in stance during sinusoidal support surface translations (12 cm peak to peak) in the anterior-posterior direction at six different frequencies. Changes in kinematic and dynamic measures revealed that both sensory and biomechanical constraints limit postural coordination patterns as a function of translation frequency. At slow frequencies (0.1 and 0.25 Hz), subjects ride the platform (with the eyes open or closed). For fast frequencies (1.0 and 1.25 Hz) with the eyes open, subjects fix their head and upper trunk in space. With the eyes closed, large-amplitude, slow-sway motion of the head and trunk occurred for fast frequencies above 0.5 Hz. Visual information stabilized posture by reducing the variability of the head's position in space and the position of the center of mass (CoM) within the support surface defined by the feet for all but the slowest translation frequencies. When subjects rode the platform, there was little oscillatory joint motion, with muscle activity limited mostly to the ankles. To support the head fixed in space and slow-sway postural patterns, subjects produced stable interjoint hip and ankle joint coordination patterns. This increase in joint motion of the lower body dissipated the energy input by fast translation frequencies and facilitated the control of upper body motion. CoM amplitude decreased with increasing translation frequency, whereas the center of pressure amplitude increased with increasing translation frequency. Our results suggest that visual information was important to maintaining a fixed position of the head and trunk in space, whereas proprioceptive information was sufficient to produce stable coordinative patterns between the support surface and legs. The CNS organizes postural patterns in this balance task as a function of available sensory information, biomechanical constraints, and translation frequency.

NASA Discipline Neuroscience↗

A new animal model for modulating myosin isoform expression by altered mechanical activity

The purpose of this study was to develop a new rodent model that is capable of delineating the importance of mechanical loading on myosin heavy chain (MHC) isoform expression of the plantar and dorsi flexor muscles of the ankle. The essential components of this system include 1) stimulating electrodes that are chronically implanted into a muscle, allowing for the control of the activation pattern of the target muscle(s); 2) a training apparatus that translates the moment of the ankle into a linear force; and 3) a computer-controlled Cambridge 310 ergometer. The isovelocity profile of the ergometer ensured that the medial gastrocnemius (MG) produced forces that were > 90% of maximal isometric force (Po), and the eccentric contractions of the tibialis anterior (TA) were typically 120% of Po. Both the concentric and eccentric training programs produced statistically significant increases in the muscle mass of the MG (approximately 15%) and TA (approximately 7%) as well as a decrease in myofibrillar adenosinetriphosphatase activity. Both the white and red regions of the MG and TA exhibited significant increases in the relative content of the type IIa MHC and concomitant decreases in type IIb MHC expression. Although the red regions of the MG and red TA contained approximately 10% type I MHC, the training programs did not affect this isoform. It appears that when a fast-twitch muscle is stimulated at a high frequency (100 Hz) and required to contract either concentrically or eccentrically under high loading conditions, the expression of the type IIa MHC isoform will be upregulated, whereas that of the type IIb MHC will be concomitantly downregulated.

NASA Discipline Musculoskeletal↗

Kinematic Characteristics of the Posture Corrective Responses After 6 Hours Exposure to Support Withdrawal Environment

Posture disorders are an inevitable consequence of exposure to microgravity . However, the role of different sensorimotor and sensory factors on postural function at different stages of the exposure to microgravity still remains unknown. The results obtained in a 6 hr dry immersion (DI) study where chest pushes served as a pre- and post-immersion perturbation, and DI was used as an analog of microgravity suggest that in addition to vestibular contributions, postural control may be related to a reduction of support loading and consequent decline of the tone of anti-gravitational muscles. Analysis of postural video data in response to chest pushes obtained before and after DI indicate that the structure of corrective responses was modified so that postural perturbations from threshold to moderate pushes showed a significant rise in the amplitude of ankle and knee angular displacement. With push intensity near the submaximal level, equilibrium was maintained by the elimination of excessive degrees of freedom; as manifested by the restriction of the hip joints mobility when coupled with a reduction of the knee and ankle displacement. These results suggest that DI increases the sensitivity of the posture control system by making posture control more rigid reflecting a change of the weight bearing receptors.

Sayenko D.↗

Twins Bed Rest Project: LBNP/Exercise Minimizes Changes in Lean Leg Mass, Strength and Endurance

Decreases in muscle strength and endurance frequently are observed in non-weightbearing conditions such as bed rest (BR), spaceflight or limb immobilization. Purpose: Ow purpose was to determine if supine treadmill exercise against simulated gravity, by application of lower body negative pressure (LBNP), prevents loss of lean leg mass, strength and endurance during 30 d of 6deg head-down bed rest (BR). Methods: Fifteen pairs of monozygous twins (8 male, 7 female pairs; 26+/-4 yrs; 170+/-12 cm; 62.6+/-11.3 kg; mean+/-SD) were subjects in the present study. One sibling of each pair of twins was randomly assigned to either an exercise (EX) or non-exercise (CON) group. The EX twin walked/jogged on a vertical treadmill within LBNP chamber 6 d/wk using a 40-min interval exercise protocol at 40-80% of pre-BR VO(sub 2peak). LBNP was adjusted individually for each subject such that footward force was between 1.0 and 1.2 times body weight (-53+/-5 mmHg LBNP). The CON twin performed no exercise during BR. Subjects performed isokinetic knee (60 and 120deg/s) and ankle (60deg/s) testing to assess strength and endurance (End) before and after BR. They also had their lean leg mass (L(sub mass)) evaluated by DEXA before and after BR. Results: Changes in peak torque (T(sub pk)) were smaller for flexion (flex) than for extension (ext) after BR and did not differ between groups. The CON group had larger decreases (P<0.05) in L(sub mass), knee and ankle ext T(sub pk), and knee ext End.

Amorim, Fabiano T.↗

Splanchnic Compression Improves the Efficacy of Compression Stockings to Prevent Orthostatic Intolerance

Purpose: Post-spaceflight orthostatic intolerance (OI) is observed in 20-30% of astronauts. Previous data from our laboratory suggests that this is largely a result of decreased venous return. Currently, NASA astronauts wear an anti-gravity suit (AGS) which consists of inflatable air bladders over the calves, thighs and abdomen, typically pressurized from 26 to 78 mmHg. We recently determined that, thigh-high graded compression stockings (JOBST , 55 mmHg at ankle, 6 mmHg at top of thigh) were effective, though to a lesser degree than the AGS. The purpose of this study was to evaluate the addition of splanchnic compression to prevent orthostatic intolerance. Methods: Ten healthy volunteers (6M, 4F) participated in three 80 head-up tilts on separate days while (1) normovolemic (2) hypovolemic w/ breast-high compression stockings (BS)(JOBST(R), 55 mmHg at the ankle, 6 mmHg at top of thigh, 12 mmHg over abdomen) (3) hypovolemic w/o stockings. Hypovolemia was induced by IV infusion of furosemide (0.5 mg/kg) and 48 hrs of a low salt diet to simulate plasma volume loss following space flight. Hypovolemic testing occurred 24 and 48 hrs after furosemide. One-way repeated measures ANOVA, with Bonferroni corrections, was used to test for differences in blood pressure and heart rate responses to head-up tilt, stand times were compared using a Kaplan-Meyer survival analysis. Results: BS were effective in preventing OI and presyncope in hypovolemic test subjects ( p = 0.015). BS prevented the decrease in systolic blood pressure seen during tilt in normovolemia (p < 0.001) and hypovolemia w/o countermeasure (p = 0.005). BS also prevented the decrease in diastolic blood pressure seen during tilt in normovolemia (p = 0.006) and hypovolemia w/o countermeasure (p = 0.041). Hypovolemia w/o countermeasure showed a higher tilt-induced heart rate increase (p = 0.022) than seen in normovolemia; heart rate while wearing BS was not different than normovolemia (p = 0.353). Conclusion: BS may be an effective countermeasure to post-space flight OI. The addition of splanchnic compression is more effective than the previous thigh-high garments. These stockings are readily available, inexpensive, and can be worn for days following landing as astronauts re-adapt to Earth gravity.

Platts, Steven H.↗

Gender Differences in Isokinetic Strength after 60 and 90 d Bed Rest

Recent reports suggest that changes in muscle strength following disuse may differ between males and females. PURPOSE: To examine potential gender differences in strength changes following 60 and 90 d of experimental bed rest. METHODS: Isokinetic extensor and flexor strength of the knee (60deg and 180deg/s, concentric only), ankle (30deg/s, concentric and eccentric), and trunk (60deg/s, concentric only) were measured following 60 d (males: n=4, 34.5+/-9.6 y; females: n=4, 35.5+/-8.2 y) and 90 d (males: n=10, 31.4+/-4.8 y; females: n=5, 37.6+/-9.9 y) of 6-degree head-down-tilt bed rest (BR; N=23). Subjects were fed a controlled diet (55%/15%/ 30%, CHO/PRO/FAT) that maintained body weight within 3% of the weight recorded on Day 3 of bed rest. After a familiarization session, testing was conducted 6 d before BR and 2 d after BR completion. Peak torque and total work were calculated for the tests performed. To allow us to combine data from both 60- and 90-d subjects, we used a mixed-model statistical analysis in which time and gender were fixed effects and bed rest duration was a random effect. Log-transformations of strength measures were utilized when necessary in order to meet statistical assumptions. RESULTS: Main effects were seen for both time and gender (p<0.05), showing decreased strength in response to bed rest for both males and females, and males stronger than females for most strength measures. Only one interaction effect was observed: females exhibited a greater loss of trunk extensor peak torque at 60 d versus pre-BR, relative to males (p=0.004). CONCLUSION: Sixty and 90 d of BR induced significant losses in isokinetic muscle strength of the locomotor and postural muscles of the knee, ankle, and trunk. Although males were stronger than females for most of the strength measures that we examined, only changes in trunk extensor peak torque were greater for females than males at day 60 of bed rest

English, K. L.↗

Development of an Integrated Countermeasure Device for Use in Long-Duration Space Flight

Prolonged weightlessness is associated with declines in musculoskeletal, cardiovascular, and sensorimotor health. Consequently, in-flight countermeasures are required to preserve astronaut health. We developed and tested a novel exercise countermeasure device (CCD) for use in spaceflight with the aim of preserving musculoskeletal and cardiovascular health along with an incorporated balance-training component. Additionally, the CCD features a compact footprint, and a low power requirement. Methods: After design and development of the CCD, we carried out a training study to test its ability to improve cardiovascular and muscular fitness in healthy volunteers. Fourteen male and female subjects (41.4+/-9.0 years, 69.5+/-15.4Kg) completed 12 weeks (3 sessions per week) of concurrent strength and endurance training on the CCD. Subjects were tested at baseline and after 12 weeks for 1-repetition max leg press strength (1RM), peak oxygen consumption (VO2peak), and isokinetic joint torque (ISO) at the hip, knee, and ankle. Additionally, we evaluated subjects after 6 weeks of training for changes in VO2peak and 1RM. Results: VO2peak and 1RM improved after 6-weeks, with additional improvements after 12 weeks (1.95+/-0.5, 2.28+/-0.5, 2.47+/-0.6 LY/min and 131.2+/-63.9,182.8+/-75.0, 207.0+/-75.0 Kg) for baseline, 6 weeks, and 12 weeks respectively. ISO for hip adduction, adduction, and ankle plantar flexion improved after 12 weeks of training (70.3+/-39.5, 76.8+/-39.2 and 55.7+/-21.7 N-m vs. 86.1+/-37.3, 85.1+/-34.3 and 62.1+/-26.4 N-m respectively). No changes were observed for ISO during hip flexion, knee extension, or knee flexion. Conclusions: The CCD is effective at improving cardiovascular fitness and isotonic leg strength in healthy adults. Further, the improvement in hip adductor and abductor torque provides support that the CCD may provide additional protection for the preservation of bone health at the hip.

Streeper, Tim↗

Using Tests Designed to Measure Individual Sensorimotor Subsystem Perfomance to Predict Locomotor Adaptability

Astronauts experience sensorimotor disturbances during the initial exposure to microgravity and during the readapation phase following a return to a gravitational environment. These alterations may lead to disruption in the ability to perform mission critical functions during and after these gravitational transitions. Astronauts show significant inter-subject variation in adaptive capability following gravitational transitions. The way each individual's brain synthesizes the available visual, vestibular and somatosensory information is likely the basis for much of the variation. Identifying the presence of biases in each person's use of information available from these sensorimotor subsystems and relating it to their ability to adapt to a novel locomotor task will allow us to customize a training program designed to enhance sensorimotor adaptability. Eight tests are being used to measure sensorimotor subsystem performance. Three of these use measures of body sway to characterize balance during varying sensorimotor challenges. The effect of vision is assessed by repeating conditions with eyes open and eyes closed. Standing on foam, or on a support surface that pitches to maintain a constant ankle angle provide somatosensory challenges. Information from the vestibular system is isolated when vision is removed and the support surface is compromised, and it is challenged when the tasks are done while the head is in motion. The integration and dominance of visual information is assessed in three additional tests. The Rod & Frame Test measures the degree to which a subject's perception of the visual vertical is affected by the orientation of a tilted frame in the periphery. Locomotor visual dependence is determined by assessing how much an oscillating virtual visual world affects a treadmill-walking subject. In the third of the visual manipulation tests, subjects walk an obstacle course while wearing up-down reversing prisms. The two remaining tests include direct measures of knee and ankle proprioception and a functional movement assessment that screens for movement restrictions and asymmetries. To assess each subject's locomotor adaptability subjects walk for twenty minutes on a treadmill that oscillates laterally at 0.3 Hz. Throughout the test metabolic cost provides a measure of exertion and step frequency provides a measure of stability. Additionally, at four points during the perturbation period, reaction time tests are used to probe changes in the amount of mental effort being used to perform the task. As with the adaptive capability observed in astronauts during gravitational transitions, our data shows significant variability between subjects. To aid in the analysis of the results, custom software tools have been developed to enhance in the visualization of the large number of output variables. Preliminary analyses of the data collected to date do not show a strong relationship between adaptability and any single predictor variable. Analysis continues to identify a multifactorial predictor outcome "signature" that do inform us of locomotor adaptability.

Peters, B. T.↗

Influence of Load Profile on Biomechanics of the Squat and Deadlift

Long duration space travel will expose astronauts to extended periods of reduced gravity. Since gravity is not present to assist loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to counteract the effect reduced gravity has on the body. Astronauts will exercise on a flywheel based device on the second Orion Exploration Mission (EM2). The effect that the flywheel load profile has on biomechanics is unknown when compared to free weights or a simulated free weight profile. The purpose of this evaluation is to compare the differences in lower body kinematics and kinetics between the flywheel and free weight profile. Test subjects were instrumented with reflective markers for motion capture data collection while exercising on the Device for Aerobic and Resistive Training (DART) prototype developed by TDA Research, Inc. of Wheat Ridge, CO. Exercises performed were either the squat while wearing a harness or deadlift while grasping a T-bar, both of which interfaced with the DART through a rope cable. The DART, a motorized device controlled via software, is capable of producing different load profiles. Profiles include simulated free weights with adjustable eccentric overload capability and flywheel. Test variables included the applied device load and the load profile, both set through the DART software interface. Motion capture data was collected with a 12 camera system (Smart-DX, BTS Bioengineering, Brooklyn, NY). Bilateral ground reaction force data were collected with force plates (P6000, BTS Bioengineering). DART cable force was recorded through an internal load cell. Data was collected from a total of four test subjects. The three repetition maximum was determined for each test subject for both squat and deadlift. High, medium and low loads were determined based on this maximum. The test subject performed five repetitions of each exercise at each load and each test trial was repeated twice. Cadence was controlled during exercising. Biomechanical data were used to drive the models utilizing the OpenSim software platform. Subject specific models were scaled to match the anthropometrics of the test subjects and used to estimate the peak joint angle, joint range of motion, the peak joint moment and the joint moment impulse of the lower extremity joints and the lumbar joint.These are preliminary results because the data analysis is ongoing. There was a lot of inter-subject variability, however, in general, there was a greater peak lumbar flexion angle for the flywheel squat exercise. There was a trend towards a greater range of motion at the hip for the squat exercise with free weight. There was also a greater hip extension, lumbar extension and ankle plantar flexion impulse moment during the squat exercise with free weight. During the deadlift exercise, the peak knee flexion angle and peak knee extension moment were greater when using the free weight profile. For deadlift, the hip extension, lumbar extension and ankle plantar flexion impulse moment tended to be greater with the free weight profile. Overall, the kinematic and kinetic outcomes for the flywheel profile were either statistically the same as free weight profile in many cases, significantly reduced in a few cases, and rarely higher.

Bioengineering↗

Development of an Inertial Sensor-based Methodology for Spacesuited Geology Task Assessments during Simulated Lunar Extravehicular Activities

Lunar surface exploration during Artemis missions will require the specific skill set of geology sampling. Apollo astronauts had extensive training and used specialized tools to collect lunar rocks, core samples, pebbles, sand, and dust. The inflexibility of the pressurized Apollo spacesuits forced sampling to be taken at a standstill posture. However, new exploration spacesuits are expected to incorporate advanced materials and joint bearings, allowing for greater mobility and a wider range of functional postures. Thus, science and exploration during Artemis missions will likely involve a variety of standing, squatting, and kneeling postures. In preparation for future lunar exploration missions, NASA provides geologic training to astronauts and other mission personnel. This professional training with a spacesuit in simulated lunar environments will enhance performance and reduce risk of injury to astronauts on the lunar surface. However, anecdotally, untrained or newly trained people wearing prototype planetary spacesuits have been observed to performing motions differently than a trained geologist would when conducting the same geology sampling tasks. Therefore, a tool for evaluating geology postures at extravehicular activity (EVA) training facilities becomes required. In this paper, we introduce a novel inertial measurement unit (IMU)-based method of geology task assessments in spacesuited conditions during simulated lunar EVAs. As a case study, two subjects (one geologist and one non-geologist) participated and donned the Mark III prototype planetary spacesuit during offloading with the spreader bar gimbal in NASA’s Active Response Gravity Offload System (ARGOS). For automated geology task assessments, the spacesuit was instrumented with three wireless IMUs (APDM Opal, OR, USA): one on the chest and one each on the left and right ankle bearings. Then subjects performed geology tasks using various tools (rake, trench, hammer chisel, scoop, and drive tube) for 45 minutes each. The chest IMU measured the torso tilt angle in the sagittal plane. We used an ensemble learning method with the ankle IMUs to discriminate between standing and kneeling activities. IMU data were processed using custom MATLAB (Mathworks, MA, USA) software. In our case study, the developed method was able to discriminate differences in standing and kneeling activity levels between subjects who were all highly experienced with spacesuited testing. Our preliminary data showed one subject maintained the constant and lower range of the upper body tilt angle while both standing and kneeling, while the other subject showed more variation of the upper body tilt angle and preferred bending the upper body rather than changing from standing to kneeling posture and vice versa. While geology experience may be a factor, these results need further investigation as suit sizing and ARGOS offloading configurations have been proven to have a significant influence on suited ARGOS tasks. Also, more subjects will be needed to complete these tasks for validation. IMU-based geology task assessments can provide useful information for geology training programs. Additionally, our IMU-based posture analysis can provide new insights into how to evaluate spacesuited geology task characteristics of astronauts during simulated lunar EVAs.

Kyoung Jae Kim↗

Circadian rhythms in Macaca mulatta monkeys during Bion 11 flight

Circadian rhythms of primate brain temperature, head and ankle skin temperature, motor activity, and heart rate were studied during spaceflight and on the ground. In space, the circadian rhythms of all the parameters were synchronized with diurnal Zeitgebers. However, in space the brain temperature rhythm showed a significantly more delayed phase angle, which may be ascribed to an increase of the endogenous circadian period.

Non-NASA Center↗

Mechanical loading prediction through accelerometry data during walking and running

ABSTRACT Currently, there is no way to assess mechanical loading variables such as peak ground reaction forces (pGRF) and peak loading rate (pLR) in clinical settings. The purpose of this study was to develop accelerometry‐based equations to predict both pGRF and pLR during walking and running. One hundred and thirty one subjects (79 females; 76.9 ± 19.6 kg) walked and ran at different speeds (2–14 km·h −1 ) on a force plate–instrumented treadmill while wearing accelerometers at their ankle, lower back and hip. Regression equations were developed to predict pGRF and pLR from accelerometry data. Leave‐one‐out cross‐validation was used to calculate prediction accuracy and Bland–Altman plots. Our pGRF prediction equation was compared with a reference equation previously published. Body mass and peak acceleration were included for pGRF prediction and body mass and peak acceleration rate for pLR prediction. All pGRF equation coefficients of determination were above 0.96, and a good agreement between actual and predicted pGRF was observed, with a mean absolute percent error (MAPE) below 7.3%. Accuracy indices from our equations were better than previously developed equations. All pLR prediction equations presented a lower accuracy compared to those developed to predict pGRF. Walking and running pGRF can be predicted with high accuracy by accelerometry‐based equations, representing an easy way to determine mechanical loading in free‐living conditions. The pLR prediction equations yielded a somewhat lower prediction accuracy compared with the pGRF equations.

Veras, Lucas↗

Impact of the magnetic horizon on the interpretation of the Pierre Auger Observatory spectrum and composition data

The flux of ultra-high energy cosmic rays reaching Earth above the ankle energy (5 EeV) can be described as a mixture of nuclei injected by extragalactic sources with very hard spectra and a low rigidity cutoff.Extragalactic magnetic fields existing between the Earth and the closest sources can affect the observed CR spectrum by reducing the flux of low-rigidity particles reaching Earth. We perform a combined fit of the spectrum and distributions of depth of shower maximum measured with the Pierre Auger Observatory including the effect of this magnetic horizon in the propagation of UHECRs in the intergalactic space.We find that, within a specific range of the various experimental and phenomenological systematics, the magnetic horizon effect can be relevant for turbulent magnetic field strengths in the local neighbourhood in which the closest sources lieof order B$_{rms}$ ≃ (50–100) nG (20 Mpc/d$_{s}$)( 100 kpc/L$_{coh}$)$^{1/2}$, with d$_{s}$ the typical intersource separation and L$_{coh}$ the magnetic field coherence length. When this is the case,the inferred slope of the source spectrum becomes softer and can be closer to the expectations of diffusive shock acceleration, i.e., ∝ E$^{-2}$.An additional cosmic-ray population with higher source density and softer spectra, presumably also extragalactic and dominating the cosmic-ray flux at EeV energies, is also required to reproduce the overall spectrum and composition results for all energies down to 0.6 EeV.

79 ASTRONOMY AND ASTROPHYSICS↗