Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ankle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Splanchnic Compression Improves the Efficacy of Compression Stockings to Prevent Orthostatic Intolerance

Purpose: Post-spaceflight orthostatic intolerance (OI) is observed in 20-30% of astronauts. Previous data from our laboratory suggests that this is largely a result of decreased venous return. Currently, NASA astronauts wear an anti-gravity suit (AGS) which consists of inflatable air bladders over the calves, thighs and abdomen, typically pressurized from 26 to 78 mmHg. We recently determined that, thigh-high graded compression stockings (JOBST , 55 mmHg at ankle, 6 mmHg at top of thigh) were effective, though to a lesser degree than the AGS. The purpose of this study was to evaluate the addition of splanchnic compression to prevent orthostatic intolerance. Methods: Ten healthy volunteers (6M, 4F) participated in three 80 head-up tilts on separate days while (1) normovolemic (2) hypovolemic w/ breast-high compression stockings (BS)(JOBST(R), 55 mmHg at the ankle, 6 mmHg at top of thigh, 12 mmHg over abdomen) (3) hypovolemic w/o stockings. Hypovolemia was induced by IV infusion of furosemide (0.5 mg/kg) and 48 hrs of a low salt diet to simulate plasma volume loss following space flight. Hypovolemic testing occurred 24 and 48 hrs after furosemide. One-way repeated measures ANOVA, with Bonferroni corrections, was used to test for differences in blood pressure and heart rate responses to head-up tilt, stand times were compared using a Kaplan-Meyer survival analysis. Results: BS were effective in preventing OI and presyncope in hypovolemic test subjects ( p = 0.015). BS prevented the decrease in systolic blood pressure seen during tilt in normovolemia (p < 0.001) and hypovolemia w/o countermeasure (p = 0.005). BS also prevented the decrease in diastolic blood pressure seen during tilt in normovolemia (p = 0.006) and hypovolemia w/o countermeasure (p = 0.041). Hypovolemia w/o countermeasure showed a higher tilt-induced heart rate increase (p = 0.022) than seen in normovolemia; heart rate while wearing BS was not different than normovolemia (p = 0.353). Conclusion: BS may be an effective countermeasure to post-space flight OI. The addition of splanchnic compression is more effective than the previous thigh-high garments. These stockings are readily available, inexpensive, and can be worn for days following landing as astronauts re-adapt to Earth gravity.

Platts, Steven H.↗

Gender Differences in Isokinetic Strength after 60 and 90 d Bed Rest

Recent reports suggest that changes in muscle strength following disuse may differ between males and females. PURPOSE: To examine potential gender differences in strength changes following 60 and 90 d of experimental bed rest. METHODS: Isokinetic extensor and flexor strength of the knee (60deg and 180deg/s, concentric only), ankle (30deg/s, concentric and eccentric), and trunk (60deg/s, concentric only) were measured following 60 d (males: n=4, 34.5+/-9.6 y; females: n=4, 35.5+/-8.2 y) and 90 d (males: n=10, 31.4+/-4.8 y; females: n=5, 37.6+/-9.9 y) of 6-degree head-down-tilt bed rest (BR; N=23). Subjects were fed a controlled diet (55%/15%/ 30%, CHO/PRO/FAT) that maintained body weight within 3% of the weight recorded on Day 3 of bed rest. After a familiarization session, testing was conducted 6 d before BR and 2 d after BR completion. Peak torque and total work were calculated for the tests performed. To allow us to combine data from both 60- and 90-d subjects, we used a mixed-model statistical analysis in which time and gender were fixed effects and bed rest duration was a random effect. Log-transformations of strength measures were utilized when necessary in order to meet statistical assumptions. RESULTS: Main effects were seen for both time and gender (p<0.05), showing decreased strength in response to bed rest for both males and females, and males stronger than females for most strength measures. Only one interaction effect was observed: females exhibited a greater loss of trunk extensor peak torque at 60 d versus pre-BR, relative to males (p=0.004). CONCLUSION: Sixty and 90 d of BR induced significant losses in isokinetic muscle strength of the locomotor and postural muscles of the knee, ankle, and trunk. Although males were stronger than females for most of the strength measures that we examined, only changes in trunk extensor peak torque were greater for females than males at day 60 of bed rest

English, K. L.↗

Development of an Integrated Countermeasure Device for Use in Long-Duration Space Flight

Prolonged weightlessness is associated with declines in musculoskeletal, cardiovascular, and sensorimotor health. Consequently, in-flight countermeasures are required to preserve astronaut health. We developed and tested a novel exercise countermeasure device (CCD) for use in spaceflight with the aim of preserving musculoskeletal and cardiovascular health along with an incorporated balance-training component. Additionally, the CCD features a compact footprint, and a low power requirement. Methods: After design and development of the CCD, we carried out a training study to test its ability to improve cardiovascular and muscular fitness in healthy volunteers. Fourteen male and female subjects (41.4+/-9.0 years, 69.5+/-15.4Kg) completed 12 weeks (3 sessions per week) of concurrent strength and endurance training on the CCD. Subjects were tested at baseline and after 12 weeks for 1-repetition max leg press strength (1RM), peak oxygen consumption (VO2peak), and isokinetic joint torque (ISO) at the hip, knee, and ankle. Additionally, we evaluated subjects after 6 weeks of training for changes in VO2peak and 1RM. Results: VO2peak and 1RM improved after 6-weeks, with additional improvements after 12 weeks (1.95+/-0.5, 2.28+/-0.5, 2.47+/-0.6 LY/min and 131.2+/-63.9,182.8+/-75.0, 207.0+/-75.0 Kg) for baseline, 6 weeks, and 12 weeks respectively. ISO for hip adduction, adduction, and ankle plantar flexion improved after 12 weeks of training (70.3+/-39.5, 76.8+/-39.2 and 55.7+/-21.7 N-m vs. 86.1+/-37.3, 85.1+/-34.3 and 62.1+/-26.4 N-m respectively). No changes were observed for ISO during hip flexion, knee extension, or knee flexion. Conclusions: The CCD is effective at improving cardiovascular fitness and isotonic leg strength in healthy adults. Further, the improvement in hip adductor and abductor torque provides support that the CCD may provide additional protection for the preservation of bone health at the hip.

Streeper, Tim↗

Using Tests Designed to Measure Individual Sensorimotor Subsystem Perfomance to Predict Locomotor Adaptability

Astronauts experience sensorimotor disturbances during the initial exposure to microgravity and during the readapation phase following a return to a gravitational environment. These alterations may lead to disruption in the ability to perform mission critical functions during and after these gravitational transitions. Astronauts show significant inter-subject variation in adaptive capability following gravitational transitions. The way each individual's brain synthesizes the available visual, vestibular and somatosensory information is likely the basis for much of the variation. Identifying the presence of biases in each person's use of information available from these sensorimotor subsystems and relating it to their ability to adapt to a novel locomotor task will allow us to customize a training program designed to enhance sensorimotor adaptability. Eight tests are being used to measure sensorimotor subsystem performance. Three of these use measures of body sway to characterize balance during varying sensorimotor challenges. The effect of vision is assessed by repeating conditions with eyes open and eyes closed. Standing on foam, or on a support surface that pitches to maintain a constant ankle angle provide somatosensory challenges. Information from the vestibular system is isolated when vision is removed and the support surface is compromised, and it is challenged when the tasks are done while the head is in motion. The integration and dominance of visual information is assessed in three additional tests. The Rod & Frame Test measures the degree to which a subject's perception of the visual vertical is affected by the orientation of a tilted frame in the periphery. Locomotor visual dependence is determined by assessing how much an oscillating virtual visual world affects a treadmill-walking subject. In the third of the visual manipulation tests, subjects walk an obstacle course while wearing up-down reversing prisms. The two remaining tests include direct measures of knee and ankle proprioception and a functional movement assessment that screens for movement restrictions and asymmetries. To assess each subject's locomotor adaptability subjects walk for twenty minutes on a treadmill that oscillates laterally at 0.3 Hz. Throughout the test metabolic cost provides a measure of exertion and step frequency provides a measure of stability. Additionally, at four points during the perturbation period, reaction time tests are used to probe changes in the amount of mental effort being used to perform the task. As with the adaptive capability observed in astronauts during gravitational transitions, our data shows significant variability between subjects. To aid in the analysis of the results, custom software tools have been developed to enhance in the visualization of the large number of output variables. Preliminary analyses of the data collected to date do not show a strong relationship between adaptability and any single predictor variable. Analysis continues to identify a multifactorial predictor outcome "signature" that do inform us of locomotor adaptability.

Peters, B. T.↗

Influence of Load Profile on Biomechanics of the Squat and Deadlift

Long duration space travel will expose astronauts to extended periods of reduced gravity. Since gravity is not present to assist loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to counteract the effect reduced gravity has on the body. Astronauts will exercise on a flywheel based device on the second Orion Exploration Mission (EM2). The effect that the flywheel load profile has on biomechanics is unknown when compared to free weights or a simulated free weight profile. The purpose of this evaluation is to compare the differences in lower body kinematics and kinetics between the flywheel and free weight profile. Test subjects were instrumented with reflective markers for motion capture data collection while exercising on the Device for Aerobic and Resistive Training (DART) prototype developed by TDA Research, Inc. of Wheat Ridge, CO. Exercises performed were either the squat while wearing a harness or deadlift while grasping a T-bar, both of which interfaced with the DART through a rope cable. The DART, a motorized device controlled via software, is capable of producing different load profiles. Profiles include simulated free weights with adjustable eccentric overload capability and flywheel. Test variables included the applied device load and the load profile, both set through the DART software interface. Motion capture data was collected with a 12 camera system (Smart-DX, BTS Bioengineering, Brooklyn, NY). Bilateral ground reaction force data were collected with force plates (P6000, BTS Bioengineering). DART cable force was recorded through an internal load cell. Data was collected from a total of four test subjects. The three repetition maximum was determined for each test subject for both squat and deadlift. High, medium and low loads were determined based on this maximum. The test subject performed five repetitions of each exercise at each load and each test trial was repeated twice. Cadence was controlled during exercising. Biomechanical data were used to drive the models utilizing the OpenSim software platform. Subject specific models were scaled to match the anthropometrics of the test subjects and used to estimate the peak joint angle, joint range of motion, the peak joint moment and the joint moment impulse of the lower extremity joints and the lumbar joint.These are preliminary results because the data analysis is ongoing. There was a lot of inter-subject variability, however, in general, there was a greater peak lumbar flexion angle for the flywheel squat exercise. There was a trend towards a greater range of motion at the hip for the squat exercise with free weight. There was also a greater hip extension, lumbar extension and ankle plantar flexion impulse moment during the squat exercise with free weight. During the deadlift exercise, the peak knee flexion angle and peak knee extension moment were greater when using the free weight profile. For deadlift, the hip extension, lumbar extension and ankle plantar flexion impulse moment tended to be greater with the free weight profile. Overall, the kinematic and kinetic outcomes for the flywheel profile were either statistically the same as free weight profile in many cases, significantly reduced in a few cases, and rarely higher.

Bioengineering↗

Development of an Inertial Sensor-based Methodology for Spacesuited Geology Task Assessments during Simulated Lunar Extravehicular Activities

Lunar surface exploration during Artemis missions will require the specific skill set of geology sampling. Apollo astronauts had extensive training and used specialized tools to collect lunar rocks, core samples, pebbles, sand, and dust. The inflexibility of the pressurized Apollo spacesuits forced sampling to be taken at a standstill posture. However, new exploration spacesuits are expected to incorporate advanced materials and joint bearings, allowing for greater mobility and a wider range of functional postures. Thus, science and exploration during Artemis missions will likely involve a variety of standing, squatting, and kneeling postures. In preparation for future lunar exploration missions, NASA provides geologic training to astronauts and other mission personnel. This professional training with a spacesuit in simulated lunar environments will enhance performance and reduce risk of injury to astronauts on the lunar surface. However, anecdotally, untrained or newly trained people wearing prototype planetary spacesuits have been observed to performing motions differently than a trained geologist would when conducting the same geology sampling tasks. Therefore, a tool for evaluating geology postures at extravehicular activity (EVA) training facilities becomes required. In this paper, we introduce a novel inertial measurement unit (IMU)-based method of geology task assessments in spacesuited conditions during simulated lunar EVAs. As a case study, two subjects (one geologist and one non-geologist) participated and donned the Mark III prototype planetary spacesuit during offloading with the spreader bar gimbal in NASA’s Active Response Gravity Offload System (ARGOS). For automated geology task assessments, the spacesuit was instrumented with three wireless IMUs (APDM Opal, OR, USA): one on the chest and one each on the left and right ankle bearings. Then subjects performed geology tasks using various tools (rake, trench, hammer chisel, scoop, and drive tube) for 45 minutes each. The chest IMU measured the torso tilt angle in the sagittal plane. We used an ensemble learning method with the ankle IMUs to discriminate between standing and kneeling activities. IMU data were processed using custom MATLAB (Mathworks, MA, USA) software. In our case study, the developed method was able to discriminate differences in standing and kneeling activity levels between subjects who were all highly experienced with spacesuited testing. Our preliminary data showed one subject maintained the constant and lower range of the upper body tilt angle while both standing and kneeling, while the other subject showed more variation of the upper body tilt angle and preferred bending the upper body rather than changing from standing to kneeling posture and vice versa. While geology experience may be a factor, these results need further investigation as suit sizing and ARGOS offloading configurations have been proven to have a significant influence on suited ARGOS tasks. Also, more subjects will be needed to complete these tasks for validation. IMU-based geology task assessments can provide useful information for geology training programs. Additionally, our IMU-based posture analysis can provide new insights into how to evaluate spacesuited geology task characteristics of astronauts during simulated lunar EVAs.

Kyoung Jae Kim↗

Circadian rhythms in Macaca mulatta monkeys during Bion 11 flight

Circadian rhythms of primate brain temperature, head and ankle skin temperature, motor activity, and heart rate were studied during spaceflight and on the ground. In space, the circadian rhythms of all the parameters were synchronized with diurnal Zeitgebers. However, in space the brain temperature rhythm showed a significantly more delayed phase angle, which may be ascribed to an increase of the endogenous circadian period.

Non-NASA Center↗

A model describing vestibular detection of body sway motion.

An experimental technique was developed which facilitated the formulation of a quantitative model describing vestibular detection of body sway motion in a postural response mode. All cues, except vestibular ones, which gave a subject an indication that he was beginning to sway, were eliminated using a specially designed two-degree-of-freedom platform; body sway was then induced and resulting compensatory responses at the ankle joints measured. Hybrid simulation compared the experimental results with models of the semicircular canals and utricular otolith receptors. Dynamic characteristics of the resulting canal model compared closely with characteristics of models which describe eye movement and subjective responses to body rotational motions. The average threshold level, in the postural response mode, however, was considerably lower. Analysis indicated that the otoliths probably play no role in the initial detection of body sway motion.

Nashner, L. M.↗

Further observations on the relationship of EMG and muscle force

Human skeletal muscle may be regarded as an electro-mechanical transducer. Its physiological input is a neural signal originating at the alpha motoneurons in the spinal cord and its output is force and muscle contraction, these both being dependent on the external load. Some experimental data taken during voluntary efforts around the ankle joint and by direct electrical stimulation of the nerve are described. Some of these experiments are simulated by an analog model, the input of which is recorded physiological soleus muscle EMG. The output is simulated foot torque. Limitations of a linear model and effect of some nonlinearities are discussed.

Agarwal, G. C.↗

Effects of low frequency vibration of a limb

Low frequency oscillations were applied on the ankle joint in plantarflexion/dorsiflexion rotation using a torque motor. The torque, the angular rotation and the evoked electromyogram from the gastronemius soleus and the anterior tibial muscles were recorded. Significant nonlinearities were observed in the angular rotation from 8 to 12 Hz. The following methods are used for data analysis: (1) Two cycle averaged response; (2) Fourier transform; and (3) Fourier analysis at the driving frequency. Important observations are: (1) resonance near 6 to 8 Hz; (2) slowly increasing amplitudes of oscillation near resonance; (3) self sustaining oscillations after the motor is turned off, particularly in the fatigued limb; and (4) distortion of angular rotation during which there are spontaneous recurrences of oscillation at the driving frequency.

Agarwal, G. C.↗

Development of restraint material and tucked fabric joints

A study was conducted to evaluate and select a suitable restraint material for the exterior of space suits pressurized to 4.0 PSID for normal operations, and to develop and improve tucked fabric joints for motions associated with the human shoulder, elbow, knee, waist, hip, ankle, and wrist. The many attributes of the end items are summarized to include structural integrity, simplicity, low maintenance, lightweight, high durability, low elongation, full range mobility, long life, and resistance to degradation in the operational environment.

Mcmullen, J. M.↗

Walking boot assembly

A walking boot assembly particularly suited for use with a positively pressurized spacesuit is presented. A bootie adapted to be secured to the foot of a wearer, an hermetically sealed boot for receiving the bootie having a walking sole, an inner sole, and an upper portion adapted to be attached to an ankle joint of a spacesuit, are also described.

Vykukal, H. C.↗

Load compensating reactions to perturbations at wrist joint in normal man

The electromyographic responses to step torque loads were studied in flexors and extensors at the human wrist. Based on temporal bursting patterns and functional behavior, the response was divided into four temporal components. Two early components, the myotatic (30-60 ms) late myotatic (60-120 ms) appears to be reflex response. The third postmyotatic component (120-200 ms) appear to be a triggered reaction, preceeding the fourth, stabilizing component (200-400 ms). A comparison of response at the wrist with similar data at the ankle provides the basis for a generalized classification of the response in various muscles to torque step perturbations.

Jaeger, R. J.↗

Non-steady State Effects in EHL

A number of lubricated machine elements are subjected to cyclic variations of load and speed, particularly in reciprocating machinery. It is well known that squeeze-film action plays an important role in preserving satisfactory lubricating films in many cases in which the entraining velocities fall to zero during each cycle, as in the reciprocating seal and synovial joints. The essential features of combined 'entraining' and 'normal' motion are described for both hydrodynamic and elastohydrodynamic conditions. It is shown that very small squeeze-film velocities (W), or order (h(sub o)/l)U, can lead to substantial hydrodynamic action. A brief review of previous studies of squeeze-film lubrication between spheres or cylinders and a plane is followed by reference to a recent analysis of ankle joint lubrication. It is then shown that elastohydrodynamic lubrication might be encountered in the conjunction between a piston ring and cylinder liner and that in such cases combined entraining and squeeze-film action is important. Analysis of a 2-stroke Diesel engine shows that variations in squeeze-film velocity throughout the conjunction, associated with time rates of change of elastic deformation, must be considered in a full elastohydrodynamic lubrication analysis.

Duncan Dowson↗

Glucocorticoid sensitivity, disuse, and the regulation of muscle mass

A new noninvasive immobilization procedure to be used on rats has been developed to study immobilization-induced muscle hypersensitivity to normal glucocorticoid concentration, subsequent muscle atrophy, and atrophy recovery. The immobilization procedure involves encasing the hind limb in a light-weight plasticlike cast (10 percent the usual plaster weight), completely resistant to animal gnawing. The effects of right-angle immobilization of the ankle on the slow fiber soleus, and the fast fiber extensor digitorum longus, resemble the effects of weightlessness. The increased concentration of glucocorticoid receptor sites in immobilized and denervated muscle is discussed, along with the chronic loss of muscle mass that occurs in practically all dystrophies. It is concluded that lack of mechanical work in a zero gravity environment is a major cause of glucocorticoid hypersensitivity in the body's musculature.

Almon, R. R.↗

The cosmic ray spectrum above 10(17) eV

The final analysis of the data obtained by the Sydney University Giant Airshower Recorder (SUGAR) is presented. The data has been reanalysed to take into account the effects of afterpulsing in the photomultiplier tubes. Event data was used to produce a spectrum of equivalent vertical muon number and from this a model dependent primary energy spectrum was obtained. These spectra show good evidence for the Ankle: a flattening at 10(19) eV. There is no sign of the cut-off which would be expected from the effects of the universal black body radiation.

Winn, M. M.↗

M.I.T./Canadian vestibular experiments on the Spacelab-1 mission. V - Postural responses following exposure to weightlessness

The four science crewmembers of Spacelab-1 were tested for postural control before and after a 10 day mission in weightlessness. Previous reports have shown changes in astronaut postural behavior following a return to earth's 1-g field. This study was designed to identify changes in EMG latency and amplitudes that might explain the instabilities observed post-flight. Erect posture was tested having the subject stand on a pneumatically driven posture platform which pitched rapidly and unexpectedly about the ankles causing dorsi- and plantarflexion. Electromyographic (EMG) activity from the tibialis anterior and the gastrocnemius-soleus muscles was measured during eyes open and eyes closed trials. The early (pre 500 ms) EMG response characteristics (latency, amplitude) in response to a disturbance in the posture of the subject were apparently unchanged by the 10 days of weightlessness. However, the late (post 500 ms) response showed higher amplitudes than was found pre-flight. General postural control was quantitatively measured pre- and post-flight by a 'sharpened Romberg Rails test'. This test showed decrements in standing stability with eyes closed for several days post-flight.

Kenyon, R. V.↗

Proposal for a zero-gravity toilet facility for the space station

This proposed toilet facility has a straightforward design. It has few moving parts and is easily maintained. Air and water flow provide sanitary movement of the waste. The toilet's chambers are coated with Teflon which, along with the water flow, makes it self-cleaning. An added disinfectant called Betadiene kills any bacteria that may form on the chamber walls. The chair is contoured to take into account the neutral body position and the necessary strain position for defecation. Restraints at the ankles, knees, and midsection hold the body in the chair. The waste is stored in discs of Gortex material which are inside a replaceable storage chamber. This chamber can be removed, capped and stored until eventual return to earth.

Fleri, Edgar L., Jr.↗