At least 55 records · Page 3

Fuel Injector Design Optimization for an Annular Scramjet Geometry

A four-parameter, three-level, central composite experiment design has been used to optimize the configuration of an annular scramjet injector geometry using computational fluid dynamics. The computational fluid dynamic solutions played the role of computer experiments, and response surface methodology was used to capture the simulation results for mixing efficiency and total pressure recovery within the scramjet flowpath. An optimization procedure, based upon the response surface results of mixing efficiency, was used to compare the optimal design configuration against the target efficiency value of 92.5%. The results of three different optimization procedures are presented and all point to the need to look outside the current design space for different injector geometries that can meet or exceed the stated mixing efficiency target.

Steffen, Christopher J., Jr.↗

Effect of Axially Staged Fuel Introduction on Performance of One-quarter Sector of Annular Turbojet Combustor

The design principle of injecting liquid fuel at more than one axial station in an annual turbojet combustor was investigated. Fuel was injected into the combustor as much as 5 inches downstream of the primary fuel injectors. Many fuel-injection configurations were examined and the performance results are presented for 11 configurations that best demonstrate the trends in performance obtained. The performance investigations were made at a constant combustor-inlet pressure of 15 inches of mercury absolute and at air flows up to 70 percent higher than values typical of current design practice. At these higher air flows, staging the fuel introduction improved the combustion efficiency considerably over that obtained in the combustor when no fuel staging was employed. At air flows currently encountered in turbojet engines, fuel staging was of minor value. Radial temperature distribution seemed relatively unaffected by the location of fuel-injection stations.

COMBUSTION - EFFECT OF ENGINE OPERATING CONDITIONS↗

Altitude Performance of Annular Combustor Type Turbojet Engine with JFC-2 Fuel /james W. Useller, James L. Harp, Jr. and Zelmar Barson

An investigation was made comparing the performance of JFC-2 fuel and unleaded, clear gasoline in a 3000-pound-thrust turbojet engine. The JFC-2 fuel was a blend of percent diesel fuel and 25 percent aviation gasoline. Engine combustion efficiency was equal to that obtained with gasoline at rated engine speed and altitudes up to 35,000 feet, but at lower engine speeds or at higher altitudes the JFC-2 fuel gave lower combustion efficiency. No discernible difference was obtained in starting or low-speed combustiion blow-out characteristics of the two fuels. Turbine-discharge radial temperature profiles were nearly the same at altitudes up to 35,000 feet.

Useller, James W↗

Optical Diagnosis of Gas Turbine Combustors Being Conducted

Researchers at the NASA Glenn Research Center, in collaboration with industry, are reducing gas turbine engine emissions by studying visually the air-fuel interactions and combustion processes in combustors. This is especially critical for next generation engines that, in order to be more fuel-efficient, operate at higher temperatures and pressures than the current fleet engines. Optically based experiments were conducted in support of the Ultra-Efficient Engine Technology program in Glenn's unique, world-class, advanced subsonic combustion rig (ASCR) facility. The ASCR can supply air and jet fuel at the flow rates, temperatures, and pressures that simulate the conditions expected in the combustors of high-performance, civilian aircraft engines. In addition, this facility is large enough to support true sectors ("pie" slices of a full annular combustor). Sectors enable one to test true shapes rather than rectangular approximations of the actual hardware. Therefore, there is no compromise to actual engine geometry. A schematic drawing of the sector test stand is shown. The test hardware is mounted just upstream of the instrumentation section. The test stand can accommodate hardware up to 0.76-m diameter by 1.2-m long; thus sectors or small full annular combustors can be examined in this facility. Planar (two-dimensional) imaging using laser-induced fluorescence and Mie scattering, chemiluminescence, and video imagery were obtained for a variety of engine cycle conditions. The hardware tested was a double annular sector (two adjacent fuel injectors aligned radially) representing approximately 15 of a full annular combustor. An example of the two-dimensional data obtained for this configuration is also shown. The fluorescence data show the location of fuel and hydroxyl radical (OH) along the centerline of the fuel injectors. The chemiluminescence data show C2 within the total observable volume. The top row of this figure shows images obtained at an engine low-power condition, and the bottom row shows data from a higher power operating point. The data show distinctly the differences in flame structure between low-power and high-power engine conditions, in both location and amount of species produced (OH, C2) or consumed (fuel). The unique capability of the facility coupled with its optical accessibility helps to eliminate the need for high-pressure performance extrapolations. Tests such as described here have been used successfully to assess the performance of fuel-injection concepts and to modify those designs, if needed.

Hicks, Yolanda R.↗

Monte Carlo Perturbation Analysis of Fuel Temperature Variations in the MCNP Model of the Annular Core Research Reactor

The Annular Core Research Reactor (ACRR) Monte Carlo N-Particle (MCNP) model is used by ACRR reactor operators and experiment designers at Sandia National Laboratories for a variety of computational calculations ranging from reactor kinetics parameter estimates and safety analyses to experimental planning. To understand the dominant source of uncertainty within the MCNP model, perturbations in temperature were applied to individual ACRR MCNP fuel rods. Fuel rod temperatures were randomly sampled from a uniform distribution from operational temperatures to quantify temperature-related uncertainty effects. Stochastic mixing was used to blend the cross sections of the desired temperatures using the MCNP continuous and Thermal Neutron Scattering Treatment [S(α,β)] libraries in ENDF/B-VII.1. Furthermore, this uncertainty analysis produced a 640 row × 640 column correlation and covariance matrix of the neutron energy spectra. Positive covariance was produced around the 1-MeV region and the 0.2-eV region. Correlation was found in the thermal and fast energy regions, but no correlation was observed in the slowing-down energy region because interactions in this region are not dominated by fuel.

ACRR↗

Experimental combustor study program

Advanced combustor concepts are evaluated as a means of accommodating possible future broad specification fuels. The three advanced double annular combustor concepts consisted of (1) a concept employing high pressure drop fuel nozzles for improved atomization, (2) a concept with premixing tubes in the main stage, and (3) a concept with the pilot stage on the inside and the main stage on the sideout, which is the reverse of the other two concepts. All of the advanced concepts show promise for reduced sensitivity to fuel hydrogen content. Some hardware problems were encountered, but these problems could be quickly resolved if refinement tests were conducted. The design with the premixing main stage was selected for a parametric test because of its low NOx emissions level, carbon free dome, and very low dome temperatures which were essentially independent of fuel type. The other advanced designs also had low done temperatures. The premixing dome design liner temperatures exhibited less sensitivity to fuel type than did the base-line combustor, although more sensitivity than observed for concept 1. The inner liner hot spot and the observed smoke results for the premixing design suggest that the fuel-air mixture was not as uniform as desired.

Kasper, J. M.↗

Advanced Diagnostics for Megahertz Imaging of Mixing, Fuel Spray, and Combustion Processes for Rotating Detonation Combustors

Recent advancements in megahertz rate, high-power, burst-mode laser technology are leveraged to perform and explore imaging measurements that spatially and temporally resolve the mixing, combustion, and detonation flow field in two laboratory-scale rotating detonation combustors (RDCs). In a non-premixed annular RDC, multiple imaging diagnostics are explored to investigate gaseous and liquid injector behavior, the detonation wave structure, and the propellant refill. In one instance, OH planar laser-induced fluorescence (OH-PLIF) imaging is performed up to a 2 MHz repetition rate to track the combustion products and reaction zone locations. In the same annular RDC, a single liquid fuel jet is injected, and laser-based 355-nm imaging of the fuel spray is performed up to a 1 MHz repetition rate. For this configuration, the annular RDC is used as a detonation driver to impose periodic detonation waves to interact with the fuel spray. Moreover, in this annular RDC, a range of tracer-based laser imaging measurements are explored to time-resolve the unsteady oxidizer air recovery and refill process. In a non-premixed linear RDC, planar imaging measurements of the fuel mixing are performed up to a 200 kHz repetition rate using PLIF of a tracer in the fuel supply. The fuel mixing imaging helps explain the origin of the observed pre and post wave burning, detonation structure, and enables quantifying injector recovery timescales. This paper will provide a high-level broad survey of diagnostics applied in these RDCs, lessons learned, and interesting observations.

Combustion↗

Advanced Diagnostics For Megahertz Imaging Of Mixing, Fuel Spray, And Combustion Processes For Rotating Detonation Combustors

Recent advancements in megahertz rate, high-power, burst-mode laser technology are leveraged to perform and explore imaging measurements that spatially and temporally resolve the mixing, combustion, and detonation flow field in two laboratory-scale rotating detonation combustors (RDCs). In a non-premixed annular RDC, multiple imaging diagnostics are explored to investigate gaseous and liquid injector behavior, the detonation wave structure, and the propellant refill. In one instance, OH planar laser-induced fluorescence (OH-PLIF) imaging is performed up to a 2 MHz repetition rate to track the combustion products and reaction zone locations. In the same annular RDC, a single liquid fuel jet is injected, and laser-based 355-nm imaging of the fuel spray is performed up to a 1 MHz repetition rate. For this configuration, the annular RDC is used as a detonation driver to impose periodic detonation waves to interact with the fuel spray. Moreover, in this annular RDC, a range of tracer-based laser imaging measurements are explored to time-resolve the unsteady oxidizer air recovery and refill process. In a non-premixed linear RDC, planar imaging measurements of the fuel mixing are performed up to a 200 kHz repetition rate using PLIF of a tracer in the fuel supply. The fuel mixing imaging helps explain the origin of the observed pre and post wave burning, detonation structure, and enables quantifying injector recovery timescales. This paper will provide a high-level broad survey of diagnostics applied in these RDCs, lessons learned, and interesting observations.

Combustion↗

Analytical evaluation of the impact of broad specification fuels on high bypass turbofan engine combustors

Six conceptual combustor designs for the CF6-50 high bypass turbofan engine and six conceptual combustor designs for the NASA/GE E3 high bypass turbofan engine were analyzed to provide an assessment of the major problems anticipated in using broad specification fuels in these aircraft engine combustion systems. Each of the conceptual combustor designs, which are representative of both state-of-the-art and advanced state-of-the-art combustion systems, was analyzed to estimate combustor performance, durability, and pollutant emissions when using commercial Jet A aviation fuel and when using experimental referee board specification fuel. Results indicate that lean burning, low emissions double annular combustor concepts can accommodate a wide range of fuel properties without a serious deterioration of performance or durability. However, rich burning, single annular concepts would be less tolerant to a relaxation of fuel properties. As the fuel specifications are relaxed, autoignition delay time becomes much smaller which presents a serious design and development problem for premixing-prevaporizing combustion system concepts.

Taylor, J. R.↗

Nuclear characteristics of a fissioning uranium plasma test reactor with light-water cooling

An analytical study was performed to determine a design configuration for a cavity test reactor. Test section criteria were that an average flux of 10 to the 15th power neutrons/sq cm/sec (E less than or equal to 0.12 eV) be supplied to a 61-cm-diameter spherical cavity at 200-atm pressure. Design objectives were to minimize required driver power, to use existing fuel-element technology, and to obtain fuel-element life of 10 to 100 full-power hours. Parameter calculations were made on moderator region size and material, driver fuel arrangement, control system, and structure in order to determine a feasible configuration. Although not optimized, a configuration was selected which would meet design criteria. The driver fuel region was a cylindrical annular region, one element thick, of 33 MTR-type H2O-cooled elements (Al-U fuel plate configuration), each 101 cm long. The region between the spherical test cavity and the cylindrical driver fuel region was Be (10 vol. % H2O coolant) with a midplane dimension of 8 cm. Exterior to the driver fuel, the 25-cm-thick cylindrical and axial reflectors were also Be with 10 vol. % H2O coolant. The entire reactor was contained in a 10-cm-thick steel pressure vessel, and the 200-atm cavity pressure was equalized throughout the driver reactor. Fuel-element life was 50 hr at the required driver power of 200 MW. Reactor control would be achieved with rotating poison drums located in the cylindrical reflector region. A control range of about 18 percent delta k/k was required for reactor operation.

Whitmarsh, C. L., Jr.↗

Performance of a short combustor at high altitudes using hydrogen fuel

Performance characteristics of a 16-inch annular-type combustor installed in a full-scale engine using gaseous-hydrogen fuel were obtained at simulated altitudes from 66,000 to 86,000 feet at a flight Mach number of 0.8. Combustion efficiencies of 86 percent were obtained at 86,000 feet (combustor pressure, 420 lb/sq ft abs). Combustor blowout was not encountered during the investigation.

Sivo, Joseph N↗

Performance and emission characteristics of swirl-can combustors to near-stoichiometric fuel-air ratio

Emissions and performance characteristics were determined for two full annular swirl-can combustors operated to near stoichiometric fuel-air ratio. Test condition variations were as follows: combustor inlet-air temperatures, 589, 756, 839, and 894 K; reference velocities, 24 to 37 meters per second; inlet pressure, 62 newtons per square centimeter; and fuel-air ratios, 0.015 to 0.065. The combustor average exit temperature and combustor efficiency were calculated from the combustor exhaust gas composition. For fuel-air ratios greater than 0.04, the combustion efficiency decreased with increasing fuel-air ratios in a near-linear manner. Increasing the combustor inlet air temperature tended to offset this decrease. Maximum oxides of nitrogen emission indices occurred at intermediate fuel-air ratios and were dependent on combustor design. Carbon monoxide levels were extremely high and were the primary cause of poor combustion efficiency at the higher fuel-air ratios. Unburned hydrocarbons were low for all test conditions. For high fuel-air ratios SAE smoke numbers greater than 25 were produced, except at the highest inlet-air temperatures.

Diehl, L. A.↗

Correlation of combustor acoustic power levels inferred from internal fluctuating pressure measurements

Combustion chamber acoustic power levels inferred from internal fluctuating pressure measurements are correlated with operating conditions and chamber geometries over a wide range. The variables include considerations of chamber design (can, annular, and reverse-flow annular) and size, number of fuel nozzles, burner staging and fuel split, airflow and heat release rates, and chamber inlet pressure and temperature levels. The correlated data include those obtained with combustion component development rigs as well as engines.

Vonglahn, U. H.↗