Search NASA⌕ Search

SEARCH · Search NASA

Results for “Argon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Metastable argon dynamics in a pulsed microplasma at 43 GHz

Short pulses of millimeter wave (MMW) radiation at 43 GHz create microplasma within a photonic crystal for pressures from 40 to 600 Torr (1.3 × 10 3 –8.0 × 10 4 Pa). Gas breakdown occurs within a photonic crystal, which acts as an electromagnetic resonator to create a strong initial electric field. The time response of the argon metastable density is experimentally determined during the pulse and in the afterglow using laser absorption. The metastable density overshoots the steady-state condition at the beginning of the pulse and during the afterglow. Modeling is presented to understand these observations. The overproduction of argon 1s5 at the beginning of each pulse is due to a concurrent overshoot in the MMW electric field within the photonic crystal. This field overheats the plasma electrons and enhances the production of excited states. The burst of argon metastables observed in the afterglow is due to the pooled energy of the plasma stored in electrons, ions, and excited states of argon. As a result, understanding metastable production is an important intermediate step to ionization and is also critical in the study of diode-pumped rare gas lasers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Xenon doping of liquid argon in ProtoDUNE single phase

The Deep Underground Neutrino Experiment (DUNE) will be the next generation long-baseline neutrino experiment. The far detector is designed as a complex of four LAr-TPC (Liquid Argon Time Projection Chamber) modules with 17 kt of liquid argon each. The development and validation of the first far detector technology is pursued through ProtoDUNE Single Phase (ProtoDUNE-SP), a 770 t LAr-TPC at CERN Neutrino Platform. Crucial in DUNE is the photon detection system that will ensure the trigger of non-beam events — proton decay, supernova neutrino burst and BSM searches — and will improve the timing and calorimetry for neutrino beam events. Doping liquid argon with xenon is a known technique to shift the light emitted by argon (128 nm) to a longer wavelength (178 nm) to ease its detection. The largest xenon doping test ever performed in a LAr-TPC was carried out in ProtoDUNE-SP. From February to May 2020, a gradually increasing amount of xenon was injected to also compensate for the light loss due to air contamination. The response of such a large TPC has been studied using the ProtoDUNE-SP Photon Detection System (PDS) and a dedicated setup installed before the run. With the first it was possible to study the light collection efficiency with respect to the track position, while with the second it was possible to distinguish the xenon light (178 nm) from the LAr light (128 nm). The light shifting mechanism proved to be highly efficient even at small xenon concentrations (<20 ppm in mass) furthermore it allowed recovering the light quenched by pollutants. The light collection improved far from the detection plane, enhancing the photon detector response uniformity along the drift direction and confirming a longer Rayleigh scattering length for 178 nm photons, with respect to 128 nm ones. The charge collection by the TPC was monitored proving that xenon up to 20 ppm does not impact its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel liquid argon purity monitor based on 207 Bi

A novel liquid argon purity monitor based on a 207 Bi radioactive source, emitting monochromatic internal-conversion electrons, is presented. This new monitor allows for a very precise and fast measurement of the electronegative impurities concentration in liquid argon. It can be operated continuously in liquid argon TPC experiments without interfering with the main detector operation. Different drift lengths can be assembled for the proposed device, to assess a large range of liquid argon purities while minimizing systematic uncertainties. Two prototypes have been built and successfully operated in dedicated test stands. The results and performance are reported.

double-phase↗

Measurement of isotopic separation of argon with the prototype of the cryogenic distillation plant Aria for dark matter searches

The Aria cryogenic distillation plant, located in Sardinia, Italy, is a key component of the DarkSide-20k experimental program for WIMP dark matter searches at the INFN Laboratori Nazionali del Gran Sasso, Italy. Aria is designed to purify the argon, extracted from underground wells in Colorado, USA, and used as the DarkSide-20k target material, to detector-grade quality. In this paper, we report the first measurement of argon isotopic separation by distillation with the 26 m tall Aria prototype. We discuss the measurement of the operating parameters of the column and the observation of the simultaneous separation of the three stable argon isotopes: ${}^{36}\hbox {Ar}$, ${}^{38}\textrm{Ar}$, and ${}^{40}\textrm{Ar}$. We also provide a detailed comparison of the experimental results with commercial process simulation software. This measurement of isotopic separation of argon is a significant achievement for the project, building on the success of the initial demonstration of isotopic separation of nitrogen using the same equipment in 2019.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Measurement of Differential Charged Current Quasielastic-like $\nu_\mu$–Argon Scattering Cross Sections In Kinematic Imbalance Variables With The MicroBooNE Detector

We report the first measurement of flux-integrated multi-differential cross sections for charged-current events with muon neutrinos scattering on argon with solely a muon and a single proton in the final state as a function of kinematic imbalance variables. The measurement was carried out using the Booster Neutrino Beam at Fermi National Accelerator Laboratory within the MicroBooNE Liquid Argon Time Projection Chamber detector with an exposure of 6.79 × 10 20 protons on target. Events were selected to enhance the contribution of charged-current mesonless interactions with one proton detected in the final state. The data discussed here are reported in terms of multidifferential cross sections in kinematic imbalance variables, which are generally sensitive to nuclear effects. The double-differential results in these variables can provide an excellent handle to disentagle specific nuclear aspects not easily isolated via single differential cross sections. Our results pave a path towards identifying regions of the phase-space where future interaction modeling development and Monte Carlo neutrino generator tuning efforts should concentrate. EVENT SELECTION Neutrino oscillation measurements aim to extract neutrino mixing angles, mass differences, the value of the chargeparity violating phase in the lepton sector, and to search for new physics beyond the Standard Model [1, 2]. For that to be achieved, an unprecedented understanding of neutrino-argon interactions is of utmost importance since a growing number of neutrino oscillation experiments employ Liquid Argon Time Projector Chamber (LArTPC) neutrino detectors [3–6]. The accuracy to which these experiments can extract neutrino oscillation parameters requires a good understanding of the neutrino energy. Experimentally, this energy is deduced from the measured kinetic energies of particles that are emitted following the neutrino interaction in the detector. The kinematic properties of such finalstate particles reflect complex dynamics due to nuclear and initial-state effects of the interaction [7]. However, certain categories of nuclear effects can be isolated by variables built specifically to characterize the degeneracy between such effects [8–10]. This note reports cross sections in kinematic variables sensitive to nuclear effects using events with one detected muon with momentum 0.1 < pµ < 1.2 GeV/c, and exactly one proton with 0.3 < pp < 1 GeV/c. This signal definition includes events with any number of protons below 300 MeV/c, neutrons at any momenta, and charged pions with momentum lower than 70 MeV/c. This choice is guided by the fact that their experimental signature of correlated muon-proton pairs is fairly straightforward to reconstruct [11–22]. Such events primarily originate from chargedcurrent (CC) neutrino-nucleon quasielastic (QE) scattering interactions where the neutrino removes a single intact nucleon from the nucleus without producing any additional particles. This definition can also include contributions from interactions that lead to the production of additional particles that are absent from the final state due to nuclear effects, such as pion absorption, or have momenta that are below the experimental detection threshold.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ensuring High-Purity Liquid Argon for the LBNF FDC: Collaborative Cryogenics Research Between UNICAMP and Fermilab

Ensuring High-Purity Liquid Argon for the LBNF FDC: Collaborative Cryogenics Research Between UNICAMP and Fermilab R. Doubnik1, M. Adamowski1, F. de M. Blaszczyk1, A. Hahn1, D. Montanari1, R. Mrowca1, Z. West1, C. Adriano2, T. P.M. Alegre2, D. Correia2, A. A. B. Machado2, E. Segreto2, R. G. Gonçalves3, E. M. Assaf6, J. M. Assaf3, D. Cardoso3, M. B. Fontes4, H. Da Motta4, D. Noriler5, P. J. G. Pagliuso2. 1 Fermi National Accelerator Laboratory, PO Box 500, Batavia IL 60510, United States. 2 “Gleb Wataghin” Institute of Physics, UNICAMP, Campinas-SP, 13083-859, Brazil. 3 CPqMAE - Research Center on Advanced Materials and Energy, Federal University of São Carlos (UFSCar), São Carlos, 13565-905, Brazil. 4 The Brazilian Center for Research in Physics (CBPF), Rio de Janeiro-RJ, 22290-180, Brazil. 5 School of Chemical Engineering, UNICAMP, Campinas-SP, 13083-859, Brazil. 6 São Carlos Institute of Chemistry, University of São Paulo, São Carlos-SP, 13566-590, Brazil. Email: rdoubnik@fnal.gov Abstract. The Long-Baseline Neutrino Facility (LBNF) located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, hosts the Deep Underground Neutrino Experiment (DUNE). This experiment employs cryostats containing nearly 70,000 metric tons of high-purity liquid argon (LAr). Ensuring LAr purity is critical for achieving the required electron lifetime, which directly impacts the experiment’s signal-to-noise ratio. The Horizontal Drift (HD) detector demands an electron lifetime exceeding 3 ms within its 3.5 m drift, equivalent to less than 100 parts-per-trillion (ppt) Oxygen contamination, while the Vertical Drift (VD) detector requires over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen contamination. To mitigate Nitrogen (N2) quenching of scintillation light, N2 contamination must remain below 1 ppm, as higher levels can result in up to a 20 % loss of light. The Brazil State University of Campinas (UNICAMP) significantly contributes to LBNF FDC through the development of argon purification and regeneration systems for HD and VD cryostats. UNICAMP designed and constructed the Purification Liquid Argon Cryostat (PuLArC), a small-scale test facility holding approximately 90 liters of LAr. Tests using PuLArC demonstrated that 1.2 kg of Li-FAU zeolite could reduce N₂ contamination from 20-50 ppm to 0.1-1.0 ppm within 1-2 hours. Tests at Fermilab’s Iceberg cryostat (2,596 liters) confirmed scalability, with 3 kg of Li-FAU reducing N₂ contamination from ~5 ppm to <1 ppm over 96 hours cycles without active circulation. This presentation will detail the research methods, test setups, and results, showcasing the potential of Li-FAU as an alternative to Molecular Sieve 4A for large-scale LAr systems. This advancement enhances DUNE's precision and demonstrates the impact of international collaboration on cryogenic research.

Doubnik, Roza [Fermilab]↗

Advancing Detector R&D for High-Pressure Gaseous Argon TPCs in Precision Neutrino Physics

High-pressure gaseous argon time projection chambers (HPgTPCs) represent an emerging detector paradigm for neutrino physics, combining increased target density with the intrinsic tracking and low thresholds of gaseous detectors. This approach enables detailed reconstruction of exclusive final states, improved particle identification, and sensitivity to low-energy and rare processes — capabilities that are increasingly central to precision oscillation measurements and searches for beyond-the-Standard-Model signatures. This abstract presents an overview of ongoing detector R&D toward high-pressure gaseous argon TPC operation, with emphasis on micro-pattern gas detector (MPGD) charge amplification in argon-based mixtures. We report experimental characterization of triple-GEM structures at pressures relevant for neutrino applications, including studies of multiplication factor scaling, stability, and operational voltage envelopes across gas admixtures. Measurements performed at the TOAD and GORG test stands at Fermilab help define viable amplification and electronics noise regimes in conditions where higher density imposes stricter constraints on signal formation. These results provide essential input to the optimization of high-pressure gaseous argon detectors for future neutrino experiments, including near-detector concepts such as ND-GAr in DUNE Phase II near detector upgrade. More broadly, this program shows how dedicated detector R&D can expand the precision frontier in neutrino physics by enabling complementary reconstruction capabilities beyond conventional detectors.

McConnell, Brenna [Indiana U.] (ORCID:000900041138↗

Hadron-argon cross-section measurements in ProtoDUNE-SP

The single-phase liquid argon ProtoDUNE detector (ProtoDUNE-SP) is located at CERN’s neutrino platform facility and serves as a prototype to validate the technology for the 10-kton fiducial mass liquid argon detectors for the DUNE experiment. ProtoDUNE-SP was exposed to a variety of test-beam particles (electrons, muons, pions, kaons, and protons) towards the end of 2018 collecting data in a broad range of momenta, from 0.3 - 7 GeV/c. The results will improve the understanding of final-state interactions in neutrino-argon cross-sections. The progress of the analyses towards the cross-section measurements on argon from the test-beam data collected at protoDUNE-SP will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Measurement of the Flux-Averaged Differential Charged-Current Electron-Neutrino and Antineutrino Cross Section on Argon with the MicroBooNE Detector

The MicroBooNE experiment uses a liquid argon time projection chamber (LArTPC) located at Fermilab, Chicago. MicroBooNE is able to detect neutrinos from two accelerators: on-axis from the Booster Neutrino Beam (BNB) and off-axis from the Neutrinos at the Main Injector (NuMI). While one of the primary objectives of the MicroBooNE experiment is to search for short-baseline neutrino oscillations using the BNB, it also has a rich program of R\&D, neutrino-argon cross section measurements and beyond the standard model searches. This thesis presents a detailed study of the off-axis neutrino flux from the NuMI beam at MicroBooNE as well as measurements of the charged current flux-averaged total and differential electron neutrino and antineutrino cross section on argon using this beam. The data used in these measurements was taken during the first year of MicroBooNE running while the NuMI beam was in forward horn current mode. These are the first high statistics measurement s of ele ctron neutrino argon interactions and include the first measurement of this cross section as a function of the outgoing electron energy and with full angular coverage. The measurement is compared to the GENIE and NuWro generators and shows consistency with both.

Mistry, Krishan Jitesh↗

Comparing generator predictions of transverse kinematic imbalance in neutrino-argon scattering

The largest uncertainties in estimating neutrino-nucleus interaction cross sections lie in the incomplete understanding of nuclear effects. A powerful tool to study nuclear effects is Transverse Kinematic Imbalance. This paper presents the first detailed comparison of the predictions of multiple event generators for distributions associated with Transverse Kinematic Imbalance for neutrino interactions on argon. Predictions for muon neutrinos interacting with an argon target are obtained using four standard neutrino event generation tools (GENIE, NuWro, GiBUU and NEUT). Example opportunities for discrimination between nuclear models leveraging future measurements are highlighted. The predictions shown in this paper are motivated by studying muon neutrinos from the Fermilab Booster Neutrino Beam interacting at the location of the MicroBooNE liquid argon time projection chamber, but the methods directly apply to other accelerator-based liquid argon neutrino experiments such as SBND, ICARUS and DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling impurity concentrations in liquid argon detectors

Impurities in noble liquid detectors used for neutrino and dark matter experiments can significantly impact the quality of data. We present an experimentally verified model for describing the dynamics of impurity distributions in liquid argon (LAr) detectors. The model considers sources, sinks, and transport of impurities within and between the gas and liquid argon phases. Measurements of oxygen concentrations in a 20-L LAr multi-purpose test stand are compared to calculations made with this model to show that an accurate description of the concentrations under various operational conditions can be obtained. A result of this analysis is a determination of Henry’s coefficient for oxygen in LAr. Additionally, these calculations also show that some processes have small effects on the impurity dynamics and excluding them yields a solution as a sum of two exponential terms. This solution provides a simple way to extract Henry’s coefficient with negligible approximation error. It is applied to the data and the Henry’s coefficient for oxygen in LAr is obtained as 0.84 +0.09 -0.05 , consistent with literature results. Finally, based on the analysis of the data with the model, we further suggest that, for a large liquid argon detector, barriers to flow (“baffles”) installed in the gas phase to restrict flow can help reduce the ultimate impurity concentration in the LAr.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spatial profile of argon (1s 5 ) metastables in an electron beam generated plasma

Electron beams with an applied magnetic field generate a secondary cold plasma with a selective chemical composition, featuring low-energy ions and metastable species in the discharge periphery, ideal for low-damage plasma treatment of material substrates. In this work, we studied the plasma generated by an e-beam using a 4 kV voltage in a pure argon gas environment under a magnetic field of 150 G and in the pressure range of 25–90 mTorr. We measured the absolute spatial density profile of argon (1 s 5 ) metastables in an electron beam generated plasma by laser-induced fluorescence and found it to be of the order of 10 16 m −3 . The electron temperature and the electron density measured by a Langmuir probe were of the order of 10 16 m −3 and less than an eV respectively. Electron-impact quenching was identified as a significant loss mechanism for the Ar(1s 5 ) state, leading to the saturation of the metastable density at higher pressures. Outside the primary ionization region, the spatial distribution of argon metastables followed a linear diffusion profile, indicating negligible additional production in those regions.

EEDF↗

Novel Liquid Argon Time-Projection Chamber Readouts

Liquid argon time-projection chambers (LArTPCs) have become a prominent tool for experiments in particle physics. Recent years have yielded significant advances in the techniques used to capture the signals generated by these cryogenic detectors. This article summarizes these novel developments for detection of ionization electrons and scintillation photons in LArTPCs. New methods to capture ionization signals address the challenges of scaling traditional techniques to the large scales necessary for future experiments. Pixelated readouts improve signal fidelity and expand the applicability of LArTPCs to higher-rate environments. Methods that leverage amplification in argon enable measurements in the keV regime and below. Techniques to enhance collection of argon scintillation photons improve calorimetry and expand the physics program for very large detectors. Future efforts aim to demonstrate systems for the combined detection of both electrons and photons.

43 PARTICLE ACCELERATORS↗

Mitigating the allergenicity of peanut allergen Ara h 1 by cold atmospheric pressure argon plasma jet

Abstract BACKGROUND Peanut allergy is recognized as a major food allergy that triggers severe and even fatal symptoms. Avoidance of peanuts in the diet is the main option for current safety management. Processing techniques reducing peanut allergenicity are required to develop other options. Cold plasma is currently considered as a novel non‐thermal approach to alter protein structure and has the potential to alleviate immunoreactivity of protein allergen. RESULTS The application of a cold argon plasma jet to peanut protein extract could reduce the amount of a 64 kDa protein band corresponding to a major peanut allergen Ara h 1 using sodium dodecyl sulfate–polyacrylamide gel electrophoresis, but the overall protein size distribution did not change significantly. A decrease in peanut protein solubility was a possible cause that led to the loss of protein content in the soluble fraction. Immunoblotting and enzyme‐linked immunosorbent assay elucidated that the immunoreactivity of Ara h 1 was significantly decreased with the time treated with plasma. Ara h 1 antigenicity reduced by 38% after five scans (approximately 3 min) of cold argon plasma jet treatment, and the reduction was up to 66% after approximately 15 min of treatment. CONCLUSION The results indicate that cold argon plasma jet treatment could be a suitable platform for alleviating the immunoreactivity of peanut protein. This work demonstrates an efficient, compact, and rapid platform for mitigating the allergenicity of peanuts, and shows great potential for the plasma platform as a non‐thermal technique in the food industry. © 2023 Society of Chemical Industry.

Hsu, Fu‐Chiun↗

Prospects for exploring non-standard neutrino properties with argon-based CEvNS experiments

Coherent elastic neutrino-nucleus scattering (CEvNS) provides a powerful frame-work for testing the Standard Model (SM) and searching for new physics at low energies. In this work, we examine the prospects for argon-based CEvNS experiments at stopped-pion sources to perform precision measurements of weak interactions and probe non-standard neutrino properties. Our study focused on the CENNS-10 and CENNS-750 detectors at the Spallation Neutron Source at Oak Ridge National Laboratory, the Coherent Captain Mills (CCM) detector at Los Alamos National Laboratory, and the proposed PIP2-BD detector at Fermilab’s Facility for Dark Matter Discovery (F2D2). Using realistic neutrino fluxes and detector configurations corresponding to these facilities, we evaluate event rates and sensitivities to a range of observables. Within the SM, argon-based CEvNS detectors enable precision tests of electroweak parameters, including the weak mixing angle, at momentum transfers well below the electroweak scale. We also investigate the sensitivity of these experiments to neutrino electromagnetic properties, such as the magnetic moment and effective charge radius, as well as to possible non-standard neutrino interactions with quarks. Together, these studies highlight the potential of argon-based CEvNS experiments as a clean and versatile platform for precision exploration of non-standard neutrino properties.

Carey, Sam [Wayne State U.] (ORCID:000900029607531↗

Fracture behavior of a melt-infiltration-processed SiC/Si composite at 900°C in argon, air, and steam

The fracture behavior of a melt-infiltration-processed SiC/Si composite, used to mimic the matrices of industrial fiber-reinforced ceramic composites, was examined in different atmospheres and temperatures. Specimens tested in four-point bending at 900 °C in oxygen-gettered argon, dry air, or steam-rich atmospheres exhibited higher average fracture strengths than specimens tested at 25°C. Higher mean fracture strength values were obtained for specimens tested in dry air or in a steam-rich atmosphere at 900°C than for specimens tested in high-purity, oxygen-gettered argon at this temperature. The increased fracture strengths obtained in air and in steam-rich atmospheres coincided with increased specimen oxidation and apparent oxide filling and blunting of flaws in these composites. Further, a transition in the location of catastrophic failure, from sites of preexisting damage created by Vickers indentations for tests in argon to other locations for tests in air or steam-rich atmospheres, was also consistent with such apparent oxide filling/blunting of indentation-induced flaws.

36 MATERIALS SCIENCE↗

Measurement of three-dimensional inclusive muon-neutrino charged-current cross sections on argon with the MicroBooNE detector

We report the measurement of the triple-differential cross section d 3 σ/dE vis d cos(θ μ )dP μ for inclusive muon-neutrino charged-current scattering on argon. This measurement utilizes data from 6.4 x 10 20 protons on target of exposure collected using the MicroBooNE liquid argon time projection chamber located along the Fermilab Booster Neutrino Beam with a mean neutrino energy of approximately 0.8 GeV. The mapping from reconstructed kinematics to truth quantities is validated within uncertainties by comparing the distribution of reconstructed hadronic energy in data to that of the model prediction in different muon scattering angle bins after applying a conditional constraint from the muon momentum distribution in data. The success of this validation provides confidence that the energy transfer in the MicroBooNE detector is well-modeled within simulation uncertainties, enabling a reliable unfolding to a triple-differential cross section defined at the nominal neutrino flux over muon momentum, muon scattering angle, and visible neutrino energy. This validation not only supports accurate cross-section extraction, but also establishes a critical foundation for tuning interaction models used in future neutrino oscillation measurements. The unfolded measurement covers an extensive phase space, providing a wealth of information useful for future liquid argon time projection chamber experiments measuring neutrino oscillations. Comparisons against a number of commonly used model predictions are included and their performance in different parts of the available phase-space is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computing the Paschen curve for argon with speed-limited particle-in-cell simulation

Upon inclusion of collisions, the speed-limited particle-in-cell (SLPIC) simulation method successfully computed the Paschen curve for argon. The 1D3V simulations modeled an electron cascade across an argon-filled capacitor, including electron-neutral ionization, electron-neutral elastic collisions, electron-neutral excitation, and ion-induced secondary electron emission. In electrical breakdown, the timescale difference between ion and electron motion makes traditional PIC methods computationally slow. To decrease this timescale difference and speed up computation, here we used SLPIC, a time-domain algorithm that limits the speed of the fastest electrons in the simulation. The SLPIC algorithm facilitates a straightforward, fully kinetic treatment of dynamics and collisions. SLPIC was as accurate as PIC, but ran up to 200 times faster. SLPIC accurately computed the Paschen curve for argon over three orders of magnitude in pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗