Search NASA⌕ Search

SEARCH · Search NASA

Results for “Atomic measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The MIGDAL experiment: Measuring a rare atomic process to aid the search for dark matter

We present the Migdal In Galactic Dark mAtter expLoration (MIGDAL) experiment aiming at the unambiguous observation and study of the so-called Migdal effect induced by fast-neutron scattering. It is hoped that this elusive atomic process can be exploited to enhance the reach of direct dark matter search experiments to lower masses, but it is still lacking experimental confirmation. Our goal is to detect the predicted atomic electron emission which is thought to accompany nuclear scattering with low, but calculable, probability, by deploying an Optical Time Projection Chamber filled with a low-pressure gas based on CF 4 . Initially, pure CF 4 will be used, and then in mixtures containing other elements employed by leading dark matter search technologies — including noble species, plus Si and Ge. High resolution track images generated by a Gas Electron Multiplier stack, together with timing information from scintillation and ionisation readout, will be used for 3D reconstruction of the characteristic event topology expected for this process — an arrangement of two tracks sharing a common vertex, with one belonging to a Migdal electron and the other to a nuclear recoil. Different energy-loss rate distributions along both tracks will be used as a powerful discrimination tool against background events. In this article we present the design of the experiment, informed by extensive particle and track simulations and detailed estimations of signal and background rates. In pure CF 4 we expect to observe 8.9 (29.3) Migdal events per calendar day of exposure to an intense D–D (D–T) neutron generator beam at the NILE facility located at the Rutherford Appleton Laboratory (UK). With our nominal assumptions, 5σ median discovery significance can be achieved in under one day with either generator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evolution of the Heliotail Lobes over a Solar Cycle as Measured by IBEX

Energetic neutral atom (ENA) measurements by IBEX reveal that the heliotail comprises an energy-dependent multilobe structure. We examine the heliotail evolution over 11 yr of IBEX observations covering a full solar cycle (SC). We find the following: (1) The heliotail structure persists over the entire SC, comprising three ENA-enhanced and two ENA-suppressed lobes. (2) Lobe sizes and locations are generally stable but exhibit variations in ENA fluxes driven by the SC. (3) Lobe centers follow a cyclic behavior over multiple SC phases, indicating direct signatures of slow and fast solar wind (SW) interactions in the inner heliosheath (IHS). (4) The tilted plane passing through the port–starboard lobes' centers oscillates in latitude but maintains its tilt from the ecliptic plane, likely a consequence of the interstellar magnetic field draping around the heliosphere. (5) The transition of the central heliotail from a single lobe at ~1.1 keV to two lobes above ~2 keV is SC-dependent and directly reflects the IHS plasma properties, i.e., when ENA fluxes from fast SW from the polar coronal holes change over time. (6) The central lobe exhibits a substructure that is enhanced and offset from the downwind direction, possibly indicating an asymmetric ENA emission or an asymmetry in the parent plasma distribution. These results reveal the general stability of the heliotail structure over time and distinct variations in individual lobes' properties in relation to the SC phases. Furthermore, results show the effects of multiple SC phases in the tail, reflecting different ENA travel times and source histories.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of material isotopics and atom number ratio with α-particle spectroscopy for a NIFFTE fission Time Projection Chamber actinide target

In this work, we present the results of a measurement of isotopic concentrations and atomic number ratio of a double-sided actinide target using α-spectroscopy and mass spectrometry. The double-sided actinide target, with predominantly 239 Pu on one side and 235 U on the other, was used in the fission Time Projection Chamber (fissionTPC) for a measurement of the neutron-induced fission cross-section ratio between the two isotopes. The measured atomic number ratio is needed to extract an absolute measurement fission cross-section ratio. The 239 Pu/ 235 U atom number ratio was measured with a combination of mass spectrometry and α-spectroscopy with a planar silicon detector achieving uncertainties of less than 1%. Different strategies for estimating isotopic concentration from the α-spectrum are presented to demonstrate the potential of these methods for non-destructive target assay. We found that a combination of fitting spectra with constraints from mass spectrometry, and summing counts in a region of the spectrum provided the most consistent results with the lowest uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Guided cold atom inertial sensors with membrane integrated photonics on atom trap integrated platforms

A guided cold-atom inertial sensor system comprises an atom trap integrated platform, a laser system, a magnetic field system, a control system, and a computing system. The laser system and magnetic field system are adapted to form a magneto-optical trap (MOT) about a suspended waveguide of the atom trap integrated platform made of membrane integrated photonics. After loading cold atoms from a MOT, the photonic atom trap integrated platform generates one-dimensional guided atoms with an evanescent field optical dipole trap (EF-ODT) along the optical waveguide to create guided atomic accelerometers/gyroscopes. Motion of atomic wavepackets in a superposition state is created along the guided atom geometry by way of state-dependent momentum kicks. The light-pulse sequence of guided atom interferometry splits, redirects, and recombines atomic wavepackets, which allows measurement of atom interference fringes sensitive to inertial forces via a probe laser.

Lee, Jongmin↗

A diagnostic to measure time-resolved atom column density and Doppler temperature in atomic vapors produced by laser ablation

We report on the development of a diagnostic to measure the time-resolved column density and Doppler temperature of atomic vapors produced by laser ablation. The diagnostic is based on the strong frequency dependence of the atomic susceptibility near an electronic transition in the interrogated atomic species. Interference on the face of a fast photodetector between the several frequency components present in a sinusoidally phase-modulated probe beam will produce a time signature uniquely determined by the column density of atoms in the probed atomic state and the Doppler temperature of the atomic vapor. With the extensive, high precision atomic spectroscopy data available in the literature, it is possible to model the vapor and extract the desired parameters through comparison of the model result with the experimental data.

47 OTHER INSTRUMENTATION↗

Grain Boundary Plane Measurement Using Transmission Electron Microscopy Automated Crystallographic Orientation Mapping for Atom Probe Tomography Specimens

Abstract Grain boundaries are critical in determining the properties of materials, including mechanical stability, conductivity, and corrosion resistance. The specific properties of materials depend not only on the misorientation of the crystals, the three most commonly characterized parameters, but also on the angle of the grain boundary plane between the two crystals, the final two parameters in the five-parameter macroscopic description of the grain boundary. The method presented here allows for the direct measurement of all five parameters of the grain boundary in a transmission electron microscopy specimen of various morphologies. This is especially applicable to atom probe specimens, where only a single-tilt axis is generally available, allowing the crystallographic description to be matched to the detailed chemical data available in the atom probe tomography. This method provides a platform for efficient grain boundary analysis in unique samples, saving operator time and allowing for ease of acquisition and interpretation in comparison with traditional electron diffraction methods.

Materials Science↗

Measurement of neutral gadolinium oscillator strengths using dual-comb absorption spectroscopy in laser-produced plasmas

The oscillator strengths of 43 transitions of neutral gadolinium from 530 to 535 nm were determined based on high-resolution absorption spectra measured by probing a laser-produced plasma (LPP) using time-resolved dual-comb spectroscopy (DCS). Absorption spectra were measured at various time delays, ranging from 33 to 252 µs after the onset of the plasma formation, over which the temperature and number density varied as the ablation plume evolved. A Boltzmann analysis was used to determine the excitation temperature and column density of Gd in the ablation plume, based on measured absorption from 20 Gd I spectral lines with known oscillator strengths. Oscillator strengths were then determined for additional dipole-allowed Gd I transitions identified in the absorption spectra, 19 of which were previously unreported. Oscillator strengths of all measured transitions were compared with literature values when available and show good agreement in most cases. Time-resolved measurement of atomic absorption in the cooling plasma provides access to a range of excitation temperatures and optical densities for the atoms in the ablation plume, allowing repeated measurements under different conditions, thereby improving confidence in the results. The high spectral bandwidth and resolution capabilities of DCS make it well-suited to measuring the dense optical spectrum of Gd, and the technique is applicable to other elements, especially lanthanides and actinides.

(280.4788) Optical Sensing, (280.5395) Plasma Diag↗

Nuclear charge densities in spherical and deformed nuclei: Toward precise calculations of charge radii

Precise measurements of atomic transitions affected by electron-nucleus hyperfine interactions offer sensitivity to explore basic properties of the atomic nucleus and study fundamental symmetries, including the search for new physics beyond the standard model of particle physics. Specifically, such measurements, augmented by atomic and nuclear calculations, will enable extraction of the higher-order radial moments of the charge-density distribution in spherical and deformed nuclei. The new data impose higher precision requirements on a theoretical description. The nuclear charge density is composed of the proton point distribution folded with the nucleonic charge distributions. The latter induce subtle relativistic corrections due to the coupling of nucleon magnetic moments with the nuclear spin-orbit density. Additional corrections come from the effect of center-of-mass projection. We assess the precision of nuclear charge density calculations by studying the behavior of relativistic and center-of-mass motion corrections to the second and fourth charge radial moments. Special attention has been paid to the magnetic spin-orbit density associated with the local variations of the spin-orbit current. The calculations for semimagic and open-shell nuclei are performed in the framework of self-consistent mean-field theory using quantified energy density functionals and density-dependent pairing forces. We used the general expression for the spin-orbit form factor that is valid for spherical and deformed nuclei. We studied the impact of various correction terms on the charge radii, fourth radial moments, diffraction radii, and surface thickness of spherical and deformed nuclei. The spin-orbit corrections to charge radial moments and surface thickness show strong shell fluctuations which can make an appreciable effect when aiming at high-precision predictions of isotopic shifts. The inclusion of relativistic and center-of-mass corrections impacts the quality of energy density functionals optimized to charge radii data. To establish reliable constraints on the existence of new forces from isotope shift measurements, precise calculations of nuclear charge densities of deformed nuclei are needed. The proper inclusion of the spin-orbit charge density and other correction terms is essential when aiming at extraction of subtle effects which become particularly visible in isotopic trends. It is also important when developing high-quality nuclear energy density functionals optimized using heterogeneous datasets involving absolute charge radii, differential charge radii, and charge form factor properties deduced from electron-scattering data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determining the tilt of the Raman laser beam using an optical method for atom gravimeters

The tilt of a Raman laser beam is a major systematic error in precision gravity measurement using atom interferometry. The conventional approach to evaluating this tilt error involves modulating the direction of the Raman laser beam and conducting time-consuming gravity measurements to identify the error minimum. In this work, we demonstrate a method to expediently determine the tilt of the Raman laser beam by transforming the tilt angle measurement into characterization of parallelism, which integrates the optical method of aligning the laser direction, commonly used in freely falling corner-cube gravimeters, into an atom gravimeter. A position-sensing detector (PSD) is utilized to quantitatively characterize the parallelism between the test beam and the reference beam, thus measuring the tilt precisely and rapidly. After carefully positioning the PSD and calibrating the relationship between the distance measured by the PSD and the tilt angle measured by the tiltmeter, we achieved a statistical uncertainty of less than 30 µrad in the tilt measurement. Furthermore, we compared the results obtained through this optical method with those from the conventional tilt modulation method for gravity measurement. The comparison validates that our optical method can achieve tilt determination with an accuracy level of better than 200 µrad, corresponding to a systematic error of 20 µGal in g measurement. This work has practical implications for real-world applications of atom gravimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lifetime-Limited Interrogation of Two Independent 27 Al + Clocks Using Correlation Spectroscopy

Laser decoherence limits the stability of optical clocks by broadening the observable resonance linewidths and adding noise during the dead time between clock probes. Correlation spectroscopy avoids these limitations by measuring correlated atomic transitions between two ensembles, which provides a frequency difference measurement independent of laser noise. Here, we apply this technique to perform stability measurements between two independent clocks based on the 1 S 0 ↔ 3 P 0 transition in 27 Al + . By stabilizing the dominant sources of differential phase noise between the two clocks, we observe coherence between them during synchronous Ramsey interrogations as long as 8 s at a frequency of 1.12 × 10 15 Hz. Here, the observed contrast in the correlation spectroscopy signal is consistent with the 20.6 s 3 P 0 state lifetime and represents a measurement instability of (1.8 ± 0.5) × 10 –16 /√τ/s for averaging periods longer than the probe duration when dead time is negligible.

74 ATOMIC AND MOLECULAR PHYSICS↗

Mass measurement of 27 P to constrain type-I x-ray burst models and validate the isobaric multiplet mass equation for the $A = 27, T = \frac{3}{2}$ isospin quartet

Background: Light curves are the primary observable of type-I x-ray bursts. Computational x-ray burst models must match simulations to observed light curves. Most of the error in simulated curves comes from uncertainties in rp process reaction rates, which can be reduced via precision mass measurements of neutron-deficient isotopes in the rp process path. Purpose: Perform a precise atomic mass measurement of 27 P. Use this new measurement to calculate rp process reaction rates and input these rates into an x-ray burst model to reduce simulated light curve uncertainty. Use the mass measurement of 27 P to validate the isobaric multiplet mass equation (IMME) for the A = 27 T = 3/2 isospin quartet which 27 P belongs to. Method: High-precision Penning trap mass spectrometry utilizing the time-of-flight ion cyclotron resonance technique was used to determine the atomic mass of 27 P. The MESA code (Modules for Experiments in Stellar Astrophysics) was then used to simulate x-ray bursts using a one-dimensional multizone model to produce updated light curves. Results: The mass excess of 27 P was measured to be –670.7(6) keV, a 14-fold precision increase over the mass reported in the 2020 Atomic Mass Evaluation (AME2020). The 26 Si(p, $γ$) 27 P– 27 P($γ$, p) 26 Si rate equilibrium has been determined to a higher precision based on the precision mass measurement of 27 P. x-ray burst light curves were produced with the MESA code using the new reaction rates. Changes in the mass of 27 P seem to have minimal effect on light curves, even in burster systems tailored to maximize impact. Conclusion: The mass of 27 P does not play a significant role in x-ray burst light curves. It is important to understand that more advanced models do not just provide more precise results, but often qualitatively different ones. This result brings us a step closer to being able to extract stellar parameters from individual x-ray burst observations. In addition, the IMME has been validated for the A = 27, T = 3/2 quartet. The normal quadratic form of the IMME using the latest data yields a reduced $χ$ 2 of 2.9. Finally, the cubic term required to generate an exact fit to the latest data matches theoretical attempts to predict this term.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Atomic-scale 3D structural dynamics and functional degradation of Pt alloy nanocatalysts during the oxygen reduction reaction

Pt-based electrocatalysts are the primary choice for fuel cells due to their superior oxygen reduction reaction (ORR) activity. To enhance ORR performance and durability, extensive studies have investigated transition metal alloying, doping, and shape control to optimize the three key governing factors for ORR: geometry, local chemistry, and strain of their surface and subsurface. However, systematic optimization remains incomplete, as it requires an atomic-scale understanding of these factors and their dynamics over potential cycling, as well as their relationship to ORR activity. Here, we implement neural network-assisted atomic electron tomography to measure the 3D atomic structural dynamics and their effects on the functional degradation of PtNi alloy catalysts. Our results reveal that PtNi catalysts undergo shape changes, surface alloying, and strain relaxation during cycling, which can be effectively mitigated by Ga doping. By combining geometry, local chemistry, and strain analysis, we calculated the changes in ORR activity over thousands of cycles and observed that Ga doping leads to higher initial activity and greater stability. These findings offer a pathway to understanding 3D atomic structural dynamics and their relation to ORR activity during cycling, paving the way for the systematic design of durable, high-efficiency nanocatalysts.

Jeong, Chaehwa↗

Relevance of structural defects to the mechanism of mechanical deformation in metallic glasses

Abstract It is known that deformation in disordered materials such as metallic glasses and supercooled liquids occurs via the cooperative rearrangement of atoms or constituent particles at dynamical heterogeneities, commonly regarded as point-like defects. We show via molecular-dynamics simulations that there is no apparent relationship between atomic rearrangements and the local atomic environment as measured by the atomic-level stresses, kinetic and potential energies, and the per-atom Voronoi volume. In addition, there is only a weak correlation between atomic rearrangements and the largest and smallest eigenvalues of the dynamical matrix. Our results confirm the transient nature of dynamical heterogeneities and suggest that the notion of defects may be less relevant than that of a propensity for rearrangement.

36 MATERIALS SCIENCE↗

XPS analysis of molecular contamination and sp 2 amorphous carbon on oxidized (100) diamond

The efficacy of oxygen (O) surface terminations on diamond is an important factor for the performance and stability for diamond-based quantum sensors and electronics. Given the wide breadth of O-termination techniques, it can be difficult to discern which method would yield the highest and most consistent O coverage. Furthermore, the interpretation of surface characterization techniques is complicated by surface morphology and purity, which if not accounted for will yield inconsistent determination of the oxygen coverage. We present a comprehensive approach to consistently prepare and analyze oxygen termination of surfaces on (100) single-crystalline diamond. We report on x-ray photoelectron spectroscopy (XPS) characterization of diamond surfaces treated with six oxidation methods that include various wet chemical oxidation techniques, photochemical oxidation with UV illumination, and steam oxidation using atomic layer deposition (ALD). Our analysis entails a rigorous XPS peak-fitting procedure for measuring the functionalization of O-terminated diamond. The findings herein have provided molecular-level insights on oxidized surfaces in (100) diamond, including the demonstration of clear correlation between the measured oxygen atomic percentage and the presence of molecular contaminants containing nitrogen, silicon, and sulfur. We also provide a comparison of the sp 2 carbon content with the O1s atomic percentage and discern a correlation with the diamond samples treated with dry oxidation which eventually tapers off at a max O1s atomic percentage value of 7.09 ± 0.40%. Given these results, we conclude that the dry oxidation methods yield some of the highest oxygen amounts, with the ALD water vapor technique proving to be the cleanest technique out of all the oxidation methods explored in this work.

XPS↗